← Product Code MGQ · K962439

# DERMAPLEX HYDROGEL WOUND DRESSING (2X2,4X4,4X8,6X10) (K962439)

_Richard Hamer Assoc., Inc. · MGQ · Sep 3, 1996 · SU · SESE_

**Canonical URL:** https://fda.innolitics.com/device/K962439

## Device Facts

- **Applicant:** Richard Hamer Assoc., Inc.
- **Product Code:** MGQ
- **Decision Date:** Sep 3, 1996
- **Decision:** SESE
- **Submission Type:** Traditional
- **Device Class:** Class U
- **Review Panel:** SU
- **Attributes:** Therapeutic

## Indications for Use

For the local management of pressure ulcers, stasis ulcers, 1st and 2nd degree burns, and full and partial thickness wounds.

## Device Story

Dermaplex Hydrogel Wound Dressing; 12-ply cotton gauze pad impregnated with clear, viscous hydrogel; supplied sterile in sealed aluminum/plastic laminate pouches. Used for local management of pressure ulcers, stasis ulcers, 1st and 2nd degree burns, and full/partial thickness wounds. Applied topically to wound site by clinician or patient to provide moist wound environment. Benefits include wound protection and management of exudate.

## Clinical Evidence

No clinical data. Biocompatibility established via bench testing: primary dermal irritation (rabbits), sensitization (guinea pigs), and USP Cytotoxicity (Agarose Diffusion).

## Technological Characteristics

12-ply cotton gauze pad impregnated with hydrogel. Available in four sizes: 2"x2", 4"x4", 4"x8", 6"x10". Supplied sterile in aluminum/plastic laminate pouches. Biocompatibility per USP Cytotoxicity (Agarose Diffusion).

## Predicate Devices

- MPM GelPad ([K933495](/device/K933495.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}

K962439

SEP 3 1996

510 (k) SUMMARY

I. ADMINISTRATIVE

Submitter: Maxxim Medical, Inc.
104 Industrial Boulevard
Sugar Land, Texas 77478
713-240-2442

Contact Person: Ernest J. Henley

Date of Preparation: July 3, 1996

II. DEVICE NAME

Proprietary Name: Dermaplex Hydrogel Wound Dressing

Common Name: Wound Dressing

Classification Name: Hydrogel wound and burn dressing

III. PREDICATE DEVICE

MPM GelPad (Hydrogel Saturated Sterile Gauze); MPM Medical, Inc.; K933495.

IV. DEVICE DESCRIPTION

The Dermaplex Hydrogel Wound Dressing consists of a 12-ply cotton gauze pad dressing impregnated with a clear, viscous hydrogel. The product is available in four sizes (2" x 2", 4" x 4", 4" x 8" and 6" x 10") and is supplied sterile in sealed aluminum/plastic laminate pouches.

Biocompatibility of the device has been established by a primary dermal irritation test in rabbits and a sensitization test in guinea pigs. The product meets the requirements of the USP Cytotoxicity Test (Agarose Diffusion).

V. INTENDED USE

For the local management of pressure ulcers, stasis ulcers, 1st and 2nd degree burns, and full and partial thickness wounds.

{1}

K962439

## VI. COMPARISON TO PREDICATE DEVICE

The Dermaplex Hydrogel Wound Dressing is similar in composition, function and intended use to the MPM GelPad (MPM Medical, Inc., K933495) and other wound dressing products consisting of a cotton pad saturated with hydrogel.

Accordingly, Maxxim Medical, Inc. concluded that the Dermaplex Hydrogel Wound Dressing is as safe and effective for its intended use and performs at least as well as legally marketed predicate devices, such as the MPM GelPad.

Premarket Notification K962439

---

**Source:** [https://fda.innolitics.com/device/K962439](https://fda.innolitics.com/device/K962439)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
