INSTRUMENT SET FOR ARTHROSCOPIC PERCUTANEOUS DISCECTOMY
K961713 · KARL STORZ Endoscopy-America, Inc. · HRX · May 31, 1996 · Orthopedic
Device Facts
Record ID
K961713
Device Name
INSTRUMENT SET FOR ARTHROSCOPIC PERCUTANEOUS DISCECTOMY
Applicant
KARL STORZ Endoscopy-America, Inc.
Product Code
HRX · Orthopedic
Decision Date
May 31, 1996
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 888.1100
Device Class
Class 2
Attributes
Therapeutic
Intended Use
The KSEA instrument set for arthroscopic percutaneous discectomy is designed to be used to visualize and treat vertebral disc herniations in the lumbar region of the spine using a posterolateral approach and fluoroscopic control.
Device Story
Manually operated, reusable surgical instrument set for arthroscopic percutaneous discectomy; includes arthroscopes, forceps, cannulae, sheaths, dilation rods, dilation sheaths, trephines, puncture needles, and curettes. Used by surgeons in clinical settings to access, visualize, and treat lumbar disc herniations. Instruments facilitate posterolateral access to the spine; used in conjunction with fluoroscopic imaging for guidance. Provides mechanical access and tissue manipulation capabilities to treat herniated discs; benefits patient through minimally invasive surgical approach.
Clinical Evidence
No clinical data provided; device relies on established design and material characteristics.
Technological Characteristics
Materials: surgical grade stainless steel or chrome-plated brass. Manual operation; reusable. Form factor: long instruments for surgical access. No energy source or software.
Indications for Use
Indicated for patients with lumbar vertebral disc herniations requiring surgical treatment via posterolateral approach under fluoroscopic control.
Regulatory Classification
Identification
An arthroscope is an electrically powered endoscope intended to make visible the interior of a joint. The arthroscope and accessories also is intended to perform surgery within a joint.
Related Devices
K964919 — EMERALD MEDICAL, INC. NUCLEUS PULPOSIS EVACUATOR SYSTEM · Emerald Medical, Inc. · Jan 28, 1997
K973405 — YEUNG ENDOSCOPIC SPINE SYSTEM · Richard Wolf Medical Instruments Corp. · Mar 13, 1998
K960222 — PERCUTANEOUS ENDOSCOPIC DISCECTOMY · Richard Wolf Medical Instruments Corp. · Mar 8, 1996
K121482 — INSTRUMENT SYSTEM FOR ENDOSCOPIC SPINAL SURGERY · Theken Spine, LLC · Aug 28, 2012
K090815 — PERCUTANEOUS DISCECTOMY SYSTEM · Laurimed, LLC · May 21, 2009
Submission Summary (Full Text)
{0}
S10R7
Karl Storz Endoscopy
Karl Storz
End
600 Corporate
Culver City, CA 90230
Phone 310 558-1500
Fax 310 421 0837
10 52
K961713
MAY 3 | 1996
# 510(k) SUMMARY OF SAFETY AND EFFECTIVENESS
The summary of 510(k) safety and effectiveness information is being submitted in accordance with the requirements of the Safe Medical Devices Act (SMDA) of 1990 and 21 CFR 807.92. All data included in this document are accurate and complete to the best of KSEA’s knowledge.
**Applicant:**
Karl Storz Endoscopy - America, Inc.
600 Corporate Pointe
Culver City, CA 90230
(310) 558-1500
**Contact:**
Betty M. Johnson
Manager, Regulatory Affairs
**Device Identification:**
**Common Name**
Arthroscope, Arthroscopic forceps, cannulae, sheaths, dilation rods, dilation sheaths, Trephine, Spinal Needles, Curettes
**Trade Name**
Karl Storz Arthroscopes, Karl Storz Arthroscopic forceps, Karl Storz cannulae and sheaths, Karl Storz dilation rods and dilation sheaths, Karl Storz puncture needles, Karl Storz trephines, Karl Storz curettes
**Indication:** The KSEA instrument set for arthroscopic percutaneous discectomy is designed to be used to visualize and treat vertebral disc herniations in the lumbar region of the spine using a posterolateral approach and fluoroscopic control.
**Device Description:** The KSEA instrument set for arthroscopic percutaneous discectomy are manually operated, reusable surgical devices consisting of arthroscopes, forceps, cannulae, sheaths, dilation rods, dilation sheaths, trephines, puncture needles and curettes. The instruments are long enough to gain access to the surgical area and are designed to be used as accessories to arthroscopes. The body contact materials are surgical grade stainless steel or chrome plated brass.
**Substantial Equivalence:** The KSEA instrument set for arthroscopic percutaneous discectomy procedures are substantially equivalent to the predicate devices since the basic features, design and intended uses are similar. The minor differences in design and dimensions between the KSEA instruments and the predicate devices raise no new issues of safety and effectiveness, as these design differences have no effect on the performance, function or intended use of these devices.
Signed: Betty M. Johnson
Manager, Regulatory Affairs
006
Panel 1
/
Sort by
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.