BALLOON CANNULA 15MM X 35MM,15MM X 55MM, 10/12MM X 55MM,10/12MM X 35MM,5MM X 35MM,2MM X 35MM
Device Facts
| Record ID | K960810 |
|---|---|
| Device Name | BALLOON CANNULA 15MM X 35MM,15MM X 55MM, 10/12MM X 55MM,10/12MM X 35MM,5MM X 35MM,2MM X 35MM |
| Applicant | Marlo Surgical Technology |
| Product Code | HET · Obstetrics/Gynecology |
| Decision Date | Oct 21, 1996 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 884.1720 |
| Device Class | Class 2 |
Intended Use
The Family of Balloon Cannula are a single use, disposable sterile trocar and sleeve device intended for use during minimally invasive surgery to provide access for operative and diagnostic instrumentation. Federal law (U.S.A.) restricts this device to sale by or on the order of a physician.
Device Story
Single-use, disposable trocar and sleeve system; provides access for surgical/diagnostic instruments during minimally invasive procedures. Device utilizes balloon and control disc for abdominal wall anchoring; incorporates tamponade effect, trap door, and seals to maintain pneumoperitoneum by minimizing CO2 loss. Operated by surgeons in clinical/OR settings. Output is physical access port for instrumentation. Benefits include stable instrument access and maintenance of insufflation.
Clinical Evidence
No clinical data; bench testing only.
Technological Characteristics
Materials: Silicone balloon, thermoplastic body, aluminum trocar. Sterilization: Gamma radiation (SAL 10^-6). Function: Balloon-based anchoring with control disc; gas-tight seals and trap door for CO2 retention. Dimensions: 2-15mm range.
Indications for Use
Indicated for patients undergoing minimally invasive surgery requiring access for operative and diagnostic instrumentation; provides anchor via balloon and control disc; minimizes CO2 gas loss via tamponade effect, trap door, and seals.
Regulatory Classification
Identification
A gynecologic laparoscope is a device used to permit direct viewing of the organs within the peritoneum by a telescopic system introduced through the abdominal wall. It is used to perform diagnostic and surgical procedures on the female genital organs. This generic type of device may include: Trocar and cannula, instruments used through an operating channel, scope preheater, light source and cables, and component parts.
Predicate Devices
- Hasson Stabilizing Access Cannula (SAC™)
Related Devices
- K202931 — Disposable Trocar · Wuxi Shukang Medical Appliance Co., Ltd. · Nov 17, 2020
- K071571 — SURGIQUEST AIRSEAL OPTICAL TROCAR & CANNULA SYSTEM · Surgiquest, Inc. · Jul 30, 2007
- K083218 — TC ENDO PORT · Transcardiac Therapeutics, Inc. · Mar 6, 2009
- K180208 — Disposable Endoscopic Trocar · Fengh Medical Co., Ltd. · Apr 9, 2018
- K981941 — MULTAPORT CANNULA REDUCER AND ACCESSORIES · Dexide, Inc. · Jul 29, 1998