Single use, camented or pressfit hip replacement component for use in patients requiring joint replacement due to trauma, disease or failed previous hip replacement surgery.
The Achantage MAPF Femoral Component is a cobalt alloy (Co-Cr-Mo) fernoral stam which is designed to articulate with any commercially available acetabular component. It has no linkage across the joint.
The MAPF devices are straight, as apposed to anatomic or curved in design. This eliminates the need for left and right configurations thus recucing the cost of inventory to the hospital. The Hosam distal goometry increases the strength and flexibility of the device. The lateral edge of the device is straight which anables the surgeon to rasp and asat the prosthesis, without creating a gap in the proximal lateral aspect of the femur. A lateral fin provides rotational stability. The duckbill type collar prevents subsidence.
Available in 6 sizes (diameters) for easier patient matching, all sizes are 160mm in length with a neck length of 32mm. Because this device is usually used in the older, low demand patient, it would most often be used in conjunction with a bipolar or endoprosthetic head.
This document is a Summary of Safety and Effectiveness for a medical device, specifically a hip femoral component. It does not describe an AI/ML-enabled device or a study to prove acceptance criteria for such a device.
The document focuses on the physical characteristics, indications for use, potential risks, and substantial equivalence of a traditional medical implant. Therefore, I cannot extract the requested information (acceptance criteria, device performance, sample sizes, expert qualifications, adjudication methods, MRMC studies, standalone performance, ground truth types, or training set details) as they pertain to the evaluation of an AI/ML system.
The provided text is a pre-market submission for a conventional medical device, not a study evaluating an algorithmic product.
{0}------------------------------------------------
DEC 1 6 1996
Corporate Headquarters
Mailing Address: P.O. Box 587 Warsaw, IN 46581-0587
Shipping Address: Airport Industrial Park Warsaw. IN 46580
(219) 267-6639 Office (219) 267 8137 FAX
960643
Soonson Biomet, Inc. Airport Industrial Park P.O. Box 587 Warsaw, IN 46581-0578
Device: Advantage MAPF Hip Femoral Component
Classification Name: Prosthesis, Hip, Herni-, Femoral, Metal/Polymer, Cemented or Uncemented (KWY)
Summary of Safety and Effectiveness
Indications for Use: Single use, camented or pressfit hip replacement component for use in patients requiring joint replacement due to trauma, disease or failed previous hip replacement surgery.
Device Description: The Achantage MAPF Femoral Component is a cobalt alloy (Co-Cr-Mo) fernoral stam which is designed to articulate with any commercially available acetabular component. It has no linkage across the joint.
The MAPF devices are straight, as apposed to anatomic or curved in design. This eliminates the need for left and right configurations thus recucing the cost of inventory to the hospital. The Hosam distal goometry increases the strength and flexibility of the device. The lateral edge of the device is straight which anables the surgeon to rasp and asat the prosthesis, without creating a gap in the proximal lateral aspect of the femur. A lateral fin provides rotational stability. The duckbill type collar prevents subsidence.
Available in 6 sizes (diameters) for easier patient matching, all sizes are 160mm in length with a neck length of 32mm. Because this device is usually used in the older, low demand patient, it would most often be used in conjunction with a bipolar or endoprosthetic head.
Potential Risks: The potential risks associated with this device are the same as with any joint replacement device. These include, but are not limited to:
Reaction to the bone cement Deformity of the joint Cardiovascular disorders Fracture of the coment Implant loosening/migration Breakdown of the porous surface
Blood vessel damage Soft tissue imbalance Delayed wound healing Metal sensitivity Fracture of the components Tissue growth failure
Bone fracture Infection Hematoma Dislocation Excessive wear Nerve damage
Substantial Equivalence: In function and overall design, the Advantage MAPF Femoral Components are equivalent to almost all hip components on the market. These stems include:
Moore Type Stern (Meditec) APF Moore-Type Femoral Stern (3M) Advantage MAPF Hip System (Kirschner) Ranawat/Burstein Hip System (Biomet, Inc)
N/A