PRESSUREGUARD: SELECTCARE

K960188 · Span-America Medical Systems, Inc. · FNM · Oct 2, 1996 · General Hospital

Device Facts

Record IDK960188
Device NamePRESSUREGUARD: SELECTCARE
ApplicantSpan-America Medical Systems, Inc.
Product CodeFNM · General Hospital
Decision DateOct 2, 1996
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 880.5550
Device ClassClass 2
AttributesTherapeutic

Intended Use

For the prevention and treatment of pressure ulcers.

Device Story

Powered air flotation mattress; provides pressure-reducing support; adjustable firmness for patient comfort; includes CPR mode for firm surface during resuscitation. Used in clinical settings; operated by healthcare staff. Output is physical support surface; affects patient positioning and pressure distribution; benefits include pressure ulcer prevention and treatment.

Clinical Evidence

No clinical data provided; bench testing only.

Technological Characteristics

Powered air flotation mattress system; adjustable firmness controls; integrated CPR mode for surface firming. No specific materials or software algorithms described.

Indications for Use

Indicated for patients requiring pressure ulcer prevention and treatment; suitable for individuals needing adjustable firmness support.

Regulatory Classification

Identification

An alternating pressure air flotation mattress is a device intended for medical purposes that consists of a mattress with multiple air cells that can be filled and emptied in an alternating pattern by an associated control unit to provide regular, frequent, and automatic changes in the distribution of body pressure. The device is used to prevent and treat decubitus ulcers (bed sores).

Special Controls

*Classification.* Class II (special controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 880.9.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0} SPAN-AMERICA MEDICAL SYSTEMS, INC. K960188 OCT - 2 1996 # PRESSUREGUARD: SELECT CARE ## 510K SUMMARY 1.0. Submitter: Span-America Medical Systems, Inc. Address: 70 Commerce Drive; Greenville, SC 29615 Telephone: (864) 288-8877 Contact Person: Charles B. Mitchell, President & CEO Wanda J. Totton, Director of Quality Date Prepared: January 8, 1995 2.0. Trade Name: PressureGuard: SelectCare Mattress System Common Name: Powered Air Flotation Mattress Classification Name: Unknown 3.0. Predicate Device: PressureGuard IV, 510K951112 4.0. Description: The PressureGuard SelectCare is a powered air flotation mattress which provides pressure-reducing support within a range of adjustable firmness to meet individual comfort needs. The system also includes a CPR mode, providing a firm surface for performing CPR. 5.0. Indications for Use: For the prevention and treatment of pressure ulcers. 6.0. Substantial Equivalence: The product is similar in function and intended use to the PressureGuard IV, 510K951112 for the Center and CPR Modes. P.O. Box 5231, Greenville, S.C. 29606 • 803-288-8877 • FAX 803-288-8692
Innolitics
510(k) Summary
Decision Summary
Classification Order
Enter a record ID and click Load to view the document.
100%