EUB-8000
Device Facts
| Record ID | K954220 |
|---|---|
| Device Name | EUB-8000 |
| Applicant | Hitachi Medical Corp. of America |
| Product Code | IYN · Radiology |
| Decision Date | May 7, 1997 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 892.1550 |
| Device Class | Class 2 |
| Attributes | Pediatric |
Intended Use
The Hitachi EUB-8000 Ultrasound Electronic Scanner is a Track 3 diagnostic ultrasound system capable of the following operating modes: B, M, Pulsed Doppler, Color Flow, and Continuous Wave Doppler. Probes available with the EUB-8000 are intended for the following general clinical uses: Abdominal, Cardiac, Intra-operative, Fetal, Pediatric, Small Organ, Peripheral Vascular, Biopsy, Transrectal, Transvaginal, and Neonatal Cephalic.
Device Story
Hitachi EUB-8000 is a Track 3 diagnostic ultrasound system; utilizes digital front-end electronics for echo signal detection; supports B, M, Pulsed Doppler, Color Flow, and Continuous Wave Doppler modes. Used by clinicians for imaging across various anatomical regions including abdominal, cardiac, and fetal. System provides real-time acoustic output indices (thermal/mechanical) per NEMA UD-3 standards. Output aids clinicians in diagnostic assessment and clinical decision-making.
Clinical Evidence
Bench testing only; compliance with NEMA UD-3 standard for real-time display of thermal and mechanical acoustic output indices and 1994 510(k) Diagnostic Ultrasound Guidance acoustic output limits.
Technological Characteristics
Track 3 diagnostic ultrasound system; digital front-end electronics for signal detection; supports B, M, Pulsed Doppler, Color Flow, and Continuous Wave Doppler modes; complies with IEC 601-1 (1988) safety standards.
Indications for Use
Indicated for diagnostic ultrasound imaging in abdominal, cardiac, intra-operative, fetal, pediatric, small organ, peripheral vascular, biopsy, transrectal, transvaginal, and neonatal cephalic applications.
Regulatory Classification
Identification
An ultrasonic pulsed doppler imaging system is a device that combines the features of continuous wave doppler-effect technology with pulsed-echo effect technology and is intended to determine stationary body tissue characteristics, such as depth or location of tissue interfaces or dynamic tissue characteristics such as velocity of blood or tissue motion. This generic type of device may include signal analysis and display equipment, patient and equipment supports, component parts, and accessories.
Related Devices
- K013723 — MODIFICATION TO: EUB-6500 DIAGNOSTIC ULTRASOUND SCANNER · Hitachi Medical Corp. · Feb 6, 2002
- K994026 — EUB-6000 ULTRASOUND DIAGNOSTIC SCANNER · Hitachi Medical Corp. of America · Mar 29, 2000
- K061608 — MODIFICATION TO EUB-5500 DIAGNOSTIC ULTRASOUND SCANNER · Hitachi Medical Corp. · Nov 22, 2006
- K013722 — MODIFICATION TO: EUB-8500 DIAGNOSTIC ULTRASOUND SCANNER · Hitachi Medical Corp. · Feb 11, 2002
- K032503 — EUB-5500 DIAGNOSTIC ULTRASOUND SCANNER · Hitachi Medical Systems America, Inc. · Aug 22, 2003