Velocity Alpha MR High Speed Surgical Drill System
K253772 · Adeor Medical AG · HBB · Mar 6, 2026 · Neurology
Device Facts
| Record ID | K253772 |
| Device Name | Velocity Alpha MR High Speed Surgical Drill System |
| Applicant | Adeor Medical AG |
| Product Code | HBB · Neurology |
| Decision Date | Mar 6, 2026 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 882.4370 |
| Device Class | Class 2 |
| Attributes | Therapeutic |
Intended Use
The Velocity Alpha MR High Speed Surgical Drill System is indicated for trephination, incision, cutting, removal, shaping, sawing of soft and hard tissue, bone and biomaterials in or near a magnetic field of 3.0 Tesla or less for use in Neurosurgery
Device Story
Pneumatic-powered surgical drill system; utilizes pressurized air to drive rotary surgical instruments; speed controlled via foot pedal. System comprises motor, hose, attachments, and cutting instruments. Used in neurosurgery; operates in or near magnetic fields up to 3.0 Tesla. Physician-operated in clinical/OR settings. Provides mechanical cutting/shaping of bone and tissue; facilitates surgical access and bone removal. Benefits include MR-conditional compatibility, allowing use within MRI suites without compromising safety or performance.
Clinical Evidence
No clinical data. Evidence based on non-clinical bench testing: functional validation, sterilization/cleaning validation, packaging validation, lifetime testing, MR-conditional testing (deflection tests per FDA guidance), and biocompatibility testing (ISO 10993-1). Cadaveric drill testing performed under simulated use conditions. All tests met acceptance criteria.
Technological Characteristics
Pneumatic-powered surgical motor; 80,000 rpm max speed; 6-8 bar operating pressure. Uses compressed nitrogen or medical grade air. MR-conditional up to 3.0 Tesla. Biocompatibility per ISO 10993-1 for external communicating devices in contact with neural tissue/bone <24 hours. Manual and automated sterilization/cleaning validated.
Indications for Use
Indicated for neurosurgical procedures requiring trephination, incision, cutting, removal, shaping, or sawing of soft/hard tissue, bone, and biomaterials in or near a magnetic field of 3.0 Tesla or less.
Regulatory Classification
Identification
A pneumatic cranial drill motor is a pneumatically operated power source used with removable rotating surgical cutting tools or drill bits on a patient's skull.
Predicate Devices
- Stryker Aria Pneumatic System (K061725)
Related Devices
- K061297 — ANSPACH IMRI SAFE SURGICAL DRILL SYSTEM · The Anspach Effort, Inc. · Jan 26, 2007
- K954717 — SODEM HIGH SPEED SYSTEM FOR NEUROSURGERY & MEDIAN STERNOTOMY · Sodem Diffusion SA · Jan 22, 1997
- K040186 — ANSPACH MRI SAFE SURGICAL DRILL SYSTEM · The Anspach Effort, Inc. · Apr 15, 2004
- K980686 — AESCULAP HILAN MOTOR SYSTEM · Aesculap, Inc. · Sep 2, 1998
- K013091 — ZMM 2000 ZEPPELIN MILLENNIUM MOTORDRILL SYSTEM · Von Zeppelin GmbH · Jan 25, 2002
Submission Summary (Full Text)
{0}
FDA U.S. FOOD & DRUG ADMINISTRATION
March 6, 2026
Adeor Medical AG
Silvia Laube
Official Correspondent
Martinshof 5
Valley, BY 83626
Germany
Re: K253772
Trade/Device Name: Velocity Alpha® MR High Speed Surgical Drill System
Regulation Number: 21 CFR 882.4370
Regulation Name: Pneumatic Cranial Drill Motor
Regulatory Class: Class II
Product Code: HBB, HBE
Dated: February 5, 2026
Received: February 5, 2026
Dear Silvia Laube:
We have reviewed your section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (the Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database available at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Additional information about changes that may require a new premarket notification are provided in the FDA guidance documents entitled "Deciding When to Submit a 510(k) for a Change to an Existing Device" (https://www.fda.gov/media/99812/download) and "Deciding When to Submit a 510(k) for a Software Change to an Existing Device" (https://www.fda.gov/media/99785/download).
U.S. Food & Drug Administration
10903 New Hampshire Avenue
Silver Spring, MD 20993
www.fda.gov
{1}
K253772 - Silvia Laube
Page 2
Your device is also subject to, among other requirements, the Quality Management System Regulation (QMSR) (21 CFR Part 820), which includes, but is not limited to, ISO 13485 clause 7.3 (Design controls), ISO 13484 clause 8.3 (Nonconforming product), and ISO 13485 clause 8.5 (Corrective and preventative action). Please note that regardless of whether a change requires premarket review, the QMSR requires device manufacturers to review and approve changes to device design and production (ISO 13485 clause 7.3 and 21 CFR 820.70) and document changes and approvals in the device master record (21 CFR 820.181).
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR Part 803) for devices or postmarketing safety reporting (21 CFR Part 4, Subpart B) for combination products (see https://www.fda.gov/combination-products/guidance-regulatory-information/postmarketing-safety-reporting-combination-products); good manufacturing practice requirements as set forth in the Quality Management System Regulation (QMSR) (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR Part 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR Parts 1000-1050.
All medical devices, including Class I and unclassified devices and combination product device constituent parts are required to be in compliance with the final Unique Device Identification System rule ("UDI Rule"). The UDI Rule requires, among other things, that a device bear a unique device identifier (UDI) on its label and package (21 CFR 801.20(a)) unless an exception or alternative applies (21 CFR 801.20(b)) and that the dates on the device label be formatted in accordance with 21 CFR 801.18. The UDI Rule (21 CFR 830.300(a) and 830.320(b)) also requires that certain information be submitted to the Global Unique Device Identification Database (GUDID) (21 CFR Part 830 Subpart E). For additional information on these requirements, please see the UDI System webpage at https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance/unique-device-identification-system-udi-system.
Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to https://www.fda.gov/medical-devices/medical-device-safety/medical-device-reporting-mdr-how-report-medical-device-problems.
For comprehensive regulatory information about medical devices and radiation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance) and CDRH Learn (https://www.fda.gov/training-and-continuing-education/cdrh-learn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance/contact-us-division-industry-and-consumer-education-dice) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100).
Sincerely,
JULIA E. SLOCOMB -S
Digitally signed by JULIA E. SLOCOMB -S
Date: 2026.03.06
08:28:51 -05'00'
{2}
K253772 - Silvia Laube
Page 3
for Jaime Raben, Ph.D.,
Division Director
DHT5A: Division of Neurosurgical,
Neurointerventional, and
Neurodiagnostic Devices
OHT5: Office of Neurological and
Physical Medicine Devices
Office of Product Evaluation and Quality
Center for Devices and Radiological Health
Enclosure
{3}
FORM FDA 3881 (8/23)
Page 1 of 1
PSC Publishing Services (301) 443-6740
EF
| DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration Indications for Use | Form Approved: OMB No. 0910-0120 Expiration Date: 07/31/2026 See PRA Statement below. |
| --- | --- |
| 510(k) Number (if known) K253772 | |
| Device Name Velocity Alpha MR High Speed Surgical Drill System | |
| Indications for Use (Describe) | |
| The Velocity Alpha MR High Speed Surgical Drill System is indicated for trephination, incision, cutting, removal, shaping, sawing of soft and hard tissue, bone and biomaterials in or near a magnetic field of 3.0 Tesla or less for use in Neurosurgery | |
| Type of Use (Select one or both, as applicable) ☑ Prescription Use (Part 21 CFR 801 Subpart D) ☐ Over-The-Counter Use (21 CFR 801 Subpart C) | |
| CONTINUE ON A SEPARATE PAGE IF NEEDED. | |
| This section applies only to requirements of the Paperwork Reduction Act of 1995. *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.* | |
| The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to: Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda.hhs.gov | |
| "An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number." | |
{4}
K253772 Page 1 of 3
# 510(k) Summary
I. Company: adeor medical AG
Martinshof 5
83626 Valley
Germany
II. Contact: Dr. Silvia Laube
Regulatory Affairs Manager
Phone: +49 8024 477 17 43
III. Preparation Date: March 6th, 2026
IV. Proprietary Trade Name: Velocity Alpha MR High Speed Surgical Drill System
V. Common Name: Velocity Alpha MR High Speed Surgical Drill System
VI. Classification Name: 21 CFR 882.4370 - Pneumatic cranial drill motor (Primary)
21 CFR 882.4310 - Powered simple cranial drills, burrs, trephines, and their accessories (Secondary)
VII. Classification: Class II
VIII. Product Code: HBB, HBE
IX. Primary Predicate Device: Stryker Aria Pneumatic System (K061725)
X. Device Description:
The Velocity Alpha MR High Speed Surgical Drill System is a pneumatic powered surgical motor drill system. The system supplies pressurized air to motor which powers rotary surgical instruments through the attachments. Rotational speed of the system is controlled by the foot pedal. The MR System consists of a motor, motor hose, two attachments, and 4 cutting instruments. Additionally, the system is compatible with the Velocity Alpha Pneumatic High Speed Surgical Drill System foot pedal and wall hoses. The Velocity Alpha MR High Speed Surgical Drill System, including both system-specific and system-compatible components, can be used in or near a magnetic field of 3.0 Tesla level or less.
XI. Indications for Use:
The Velocity Alpha MR High Speed Surgical Drill System is intended for trephination, incision, cutting, removal, shaping, and sawing of soft and hard tissue, bone and biomaterials in or near a magnetic field of 3.0 Tesla or less for use in Neurosurgery.
{5}
K253772 Page 2 of 3
XII. Comparison of the Technological Characteristics and Substantial Equivalence:
| Item | Predicate device | Subject device |
| --- | --- | --- |
| Trade Name | The Stryker Aria Pneumatic System | Velocity Alpha MR High Speed Surgical Drill System |
| Manufacturer | Stryker Corporation | adeor medical AG |
| K# | K061725 | K253772 |
| Regulation | 21 CFR 882.4370; Pneumatic cranial drill motor | 21 CFR 882.4370; Pneumatic cranial drill motor
21 CFR 882.4310; Powered simple cranial drills, burrs, trephines, and their accessories |
| Product code | HBB | HBB, HBE |
| Class | II | II |
| Indications for Use | Not Publicly Available | Velocity Alpha MR High Speed Surgical Drill System is indicated for trephination, incision, cutting, removal, shaping, sawing of soft and hard tissue, bone and biomaterials in or near a magnetic field of 3.0 Tesla or less for use in Neurosurgery. |
| MR conditional | Not Publicly Available | Yes – up to 3.0 Tesla |
| Max. air pressure | Not Publicly Available | Max. operating pressure: 8 bar Min. operating pressure: 6 bar |
| Gas Type | Not Publicly Available | Compressed nitrogen or medical grade compressed air |
| Maximum speed | Not Publicly Available | 80,000 rpm |
| Number of Cutting Instruments | Not Publicly Available | 4 |
XIII. Substantial Equivalence Discussion:
The subject device Velocity Alpha MR High Speed Surgical Drill System is substantially equivalent to the predicate device Stryker Aria Pneumatic System with respect to intended use, technological characteristics, user handling, and key performance and safety characteristics. The subject device has been validated according to applicable biocompatibility, usability, and performance standards, demonstrating fulfilment of all performance and safety requirements. The Velocity Alpha MR High Speed Surgical Drill System does not raise any new questions of safety or effectiveness compared to the Stryker Aria Pneumatic System.
{6}
K253772 Page 3 of 3
XIV. Performance Data Testing:
Validation & verification testing were conducted to support substantial equivalence to the predicate device.
| Test | Test Method Summary | Results |
| --- | --- | --- |
| Functional testing within MR suite | Cutting performance, motor speed, and system assembly, handling, and heating tested with 3.0 Tesla MRI | All tests fulfilled acceptance criteria. System functional performance is acceptable under simulated use conditions within intended use environment and therefore equivalent to predicate device. |
| Cadaveric drill testing | Drilling performance conducted under simulated use conditions using cadavers | Acceptance criteria were fulfilled. Drilling performance is acceptable for its intended use. |
| MR-conditional validation | Deflection tests of all system components and sub-components which may be disassembled conducted with 3.0 Telsa MRI. Testing conducted in accordance with the FDA guidance document “Testing and Labeling Medical Devices for Safety in the Magnetic Resonance (MR) Environment” | All acceptance criteria were met. Safety and efficacy equivalent to the predicate device. |
| Lifetime validation | Function and safety were assessed after expected lifetime duty cycles. | All tests fulfilled acceptance criteria. Function and safety were confirmed for the lifetime of the device and is therefore equivalent to predicate device. |
Non-clinical performance testing was conducted, including:
functional validation, sterilization validation, cleaning validation (manual and automated), packaging validation, lifetime testing, MR-conditional testing, and biocompatibility testing. All testing met acceptance criteria and confirmed that the device performs as intended.
XV. Biocompatibility:
Biocompatibility testing of the subject device was conducted in accordance with the FDA biocompatibility guidance "Use of International Standard ISO 10993-1, "Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process". All relevant acceptance criteria were met for the device components categorized as external communicating devices in contact with neural tissue, bone and dentin for <24 hours.
XVI. Conclusion:
The subject device and the predicate device are equivalent in terms of intended use and technological characteristics. Both devices are pneumatically operated surgical drill systems intended for neurosurgical procedures in MR-conditional environments up to 3.0 Tesla. Performance testing, including functional validation, sterilization validation, cleaning validation (manual and automated), MR-conditional testing and biocompatibility evaluation have demonstrated that the design differences between the subject and predicate devices do not raise different questions of safety or effectiveness. Therefore, the Velocity Alpha MR High Speed Surgical Drill System is substantially equivalent to the legally marketed predicate device, the Stryker Aria Pneumatic System (K061725).