EVOLUX CAD/CAM PMMA BLOCKS

K182065 · Blue Dent Dental · EBG · Dec 13, 2018 · Dental

Device Facts

Record IDK182065
Device NameEVOLUX CAD/CAM PMMA BLOCKS
ApplicantBlue Dent Dental
Product CodeEBG · Dental
Decision DateDec 13, 2018
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 872.3770
Device ClassClass 2
AttributesTherapeutic

Indications for Use

Evolux CAD/CAM PMMA Blocks are intended for making removable or temporary dental structures such as crowns and bridges using CAD/CAM milling technology.

Device Story

Evolux CAD/CAM PMMA Blocks are dental restorative materials supplied as pre-formed blocks. Used by dental professionals in clinical or laboratory settings; blocks are processed via CAD/CAM milling systems to fabricate temporary crowns, bridges, implant-supported restorations, denture bases, and occlusal splints. The device serves as the raw material substrate for milling; final restorations are placed in the patient's mouth to provide temporary functional and aesthetic dental support. Benefits include rapid fabrication of temporary prosthetics and therapeutic appliances.

Clinical Evidence

bench testing only

Technological Characteristics

Material: Polymethyl methacrylate (PMMA) resin. Form factor: CAD/CAM blocks. Processing: Milling technology. Intended for temporary dental restorations.

Indications for Use

Indicated for temporary anterior and posterior crowns, temporary anterior and posterior bridges (up to two adjacent pontics), implant-supported temporary restorations, removable dental base structures, and therapeutic restorations (bite or occlusal splints). Maximum usage period is 12 months.

Regulatory Classification

Identification

A temporary crown and bridge resin is a device composed of a material, such as polymethylmethacrylate, intended to make a temporary prosthesis, such as a crown or bridge, for use until a permanent restoration is fabricated.

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ Image /page/0/Picture/0 description: The image contains the logo of the U.S. Food and Drug Administration (FDA). On the left is the Department of Health & Human Services logo. To the right of that is the FDA logo, which is a blue square with the letters "FDA" in white. To the right of the blue square is the text "U.S. FOOD & DRUG ADMINISTRATION" in blue. December 13, 2018 Blue Dent Dental % Mauro Malzyner US Agent Passarini Regulatory Affairs of America, LLC Miami Center Building 201 South Biscayne Boulevard Suite 1200 Miami, Florida 33131 Re: K182065 Trade/Device Name: Evolux Cad/cam Pmma Blocks Regulation Number: 21 CFR 872.3770 Regulation Name: Temporary Crown And Bridge Resin Regulatory Class: Class II Product Code: EBG Dated: November 14, 2018 Received: November 15, 2018 Dear Mauro Malzyner: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database located at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmp/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal {1}------------------------------------------------ statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical device-related adverse events) (21 CFR 803) for devices or postmarketing safety reporting (21 CFR 4, Subpart B) for combination products (see https://www.fda.gov/CombinationProducts/GuidanceRegulatoryInformation/ucm597488.htm); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm. For comprehensive regulatory information about medical devices and radiation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/) and CDRH Learn (http://www.fda.gov/Training/CDRHLearn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (http://www.fda.gov/DICE) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100). > Sincerely. Digitally signed by Mary S Mary S. F 1Vrail y 3. Date: 2018.12.13 11:22:14 > Runner -S33 - Date: 2018.12.13 11:22:14 > ------------------------------------------------------------------------------------------------ For Tina Kiang, Ph.D. Acting Director Division of Anesthesiology, General Hospital, Respiratory, Infection Control, and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {2}------------------------------------------------ ## Indications for Use 510(k) Number (if known) K182065 Device Name Evolux CAD/CAM PMMA Blocks | Indications for Use (Describe) | | |--------------------------------|--| |--------------------------------|--| Evolux CAD/CAM PMMA Blocks are intended for making removable or temporary dental structures such as crowns and bridges using CAD/CAM milling technology. Indications: - Temporary anterior and posterior crowns - Temporary anterior and posterior bridges with up to two adjacent pontics - Implant supported temporary restorations - Maximum recommended usage period: 12 months - Removable structures for dentures (dental bases) - Removable structures for therapeutic restorations (bite splints or occlusal splints) Type of Use (Select one or both, as applicable) X Prescription Use (Part 21 CFR 801 Subpart D) | Over-The-Counter Use (21 CFR 801 Subpart C) ## CONTINUE ON A SEPARATE PAGE IF NEEDED. This section applies only to requirements of the Paperwork Reduction Act of 1995. ## *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW * The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to: > Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda.hhs.gov "An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...