STAYHEALTHY BODY COMPOSITION MONITOR-BCM

K101807 · Stayhealthy, Inc. · MNW · Jan 26, 2011 · Cardiovascular

Device Facts

Record IDK101807
Device NameSTAYHEALTHY BODY COMPOSITION MONITOR-BCM
ApplicantStayhealthy, Inc.
Product CodeMNW · Cardiovascular
Decision DateJan 26, 2011
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 870.2770
Device ClassClass 2
AttributesPediatric

Indications for Use

The BCM is used as body fat analyzer that estimate the percent body fat (%BF), percent lean body mass(%LBM) and percent total body water (TBW%) with the use of BIA (bioelectrical impedance analysis). The SAM or Stayhealthy Activity Monitor [ a triaxial accelerometer and 3axis, gyroscope equipped calorie tracker- (CT2)], is a device that is sold as companion device with the BCM and is used to track the number of calories used by the client. The device is intended for use by healthy subjects ages 8-92.

Device Story

Stayhealthy Body Composition Monitor (BCM) uses bioelectrical impedance analysis (BIA) to estimate body composition metrics; companion Stayhealthy Activity Monitor (SAM/CT2) uses triaxial accelerometer and 3-axis gyroscope to track calories burned. Intended for healthy subjects ages 8-92; used in home or clinic settings. Device provides quantitative outputs for body fat, lean body mass, total body water, and caloric expenditure. Healthcare providers or users review data to monitor body composition and activity levels; supports health and wellness tracking.

Clinical Evidence

No clinical data provided in the document; bench testing only.

Technological Characteristics

Impedance plethysmograph (21 CFR 870.2770); utilizes BIA for body composition; SAM companion device includes triaxial accelerometer and 3-axis gyroscope for activity tracking.

Indications for Use

Indicated for healthy subjects ages 8-92 to estimate percent body fat, percent lean body mass, and percent total body water using bioelectrical impedance analysis (BIA), and to track calories burned using a companion triaxial accelerometer/gyroscope activity monitor.

Regulatory Classification

Identification

An impedance plethysmograph is a device used to estimate peripheral blood flow by measuring electrical impedance changes in a region of the body such as the arms and legs.

Special Controls

*Classification.* Class II (special controls). The device, when it is a body composition analyzer which is not intended to diagnose or treat any medical condition, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 870.9.

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ Image /page/0/Picture/1 description: The image shows the logo for the U.S. Department of Health and Human Services. The logo consists of a stylized eagle with three lines representing its wings and a circular border. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES USA" is arranged around the border of the circle. Food and Drug Administration 10903 New Hampshire Avenue Document Mail Center - WO66-G609 Silver Spring, MD 20993-0002 Mr. Jesus T. Farinas Consultant Stayhealthy, Inc. 742 E. Huntington Drive. MONROVIA CA 91016 CAN. 2 6 201 Re: K101807 Trade/Device Name: Stayhealthy Body Composition Monitor-BCM Regulation Number: 21 CFR §870.2770 Regulation Name: Impedance plethysmograph Regulatory Class: II Product Code: MNW Dated: January 15, 2011 Received: January 20, 2011 Dear Mr. Farinas: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical device-related {1}------------------------------------------------ Page 2 adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fda.gov/AboutFDA/Centers0ffices/CDRH/CDRHOIffices/ucm115809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance. You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll the (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default:htm. Sincerely yours, Hubert Humphrey Herbert P. Lerner, M.D., Director (Acting) Division of Reproductive, Gastro-Renal and Urological Devices Office of Device Evaluation Center for Devices and Radiological Health ## Enclosure {2}------------------------------------------------ # Indications for Use # 510(K) NUMBER (IF KNOWN): #### DEVICE NAME: ## Stayhealthy Body Composition Monitor-BCM #### INDICATIONS FOR USE: The BCM is used as body fat analyzer that estimate the percent body fat (%BF), percent lean body mass(%LBM) and percent total body water (TBW%) with the use of BIA (bioelectrical impedance analysis). The SAM or Stayhealthy Activity Monitor [ a triaxial accelerometer and 3axis, gyroscope equipped calorie tracker- (CT2)], is a device that is sold as companion device with the BCM and is used to track the number of calories used by the client. The device is intended for use by healthy subjects ages 8-92. Prescription Use (Part 21 CFR 801 Subpart D) AND/OR Over-The-Counter Use (21 CFR 801 Subpart C) (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) losun Whang (Division Sign-Off) Division of Reproductive, Gastro-Renal, and Urological Devices 510(k) Number K101807 Page 1 of ల్లా
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...