MAS IMMUNOSUPPRESSANT CONTROLS

K051074 · Microgenics Corp. · LAS · Jun 6, 2005 · Clinical Toxicology

Device Facts

Record IDK051074
Device NameMAS IMMUNOSUPPRESSANT CONTROLS
ApplicantMicrogenics Corp.
Product CodeLAS · Clinical Toxicology
Decision DateJun 6, 2005
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 862.3280
Device ClassClass 1

Intended Use

The MAS Immunosuppressant Controls, consisting of levels 1 through 3, are in-vitro diagnostic medical devices intended for use as assayed quality control material to monitor the precision of laboratory testing procedures for cyclosporine, sirolimus, and tacrolimus.

Device Story

MAS Immunosuppressant Controls are in-vitro diagnostic quality control materials used in clinical laboratories to monitor the precision of testing procedures for cyclosporine, sirolimus, and tacrolimus. The device consists of three levels of processed human whole blood containing these immunosuppressive drugs, along with stabilizers. It is provided in a liquid form. Laboratory personnel use these controls to verify the accuracy and precision of their analytical assays. By comparing the measured values of the controls against established ranges, clinicians and laboratory staff can ensure the reliability of patient test results, thereby supporting appropriate therapeutic drug monitoring and clinical decision-making.

Clinical Evidence

No clinical data. Substantial equivalence is based on bench testing and comparison of physical properties and intended use to the predicate device.

Technological Characteristics

Processed human whole blood matrix; liquid form; contains cyclosporine, sirolimus, and tacrolimus; three levels; 14-day open-vial stability at 2°C to 8°C; stored at -20°C until expiration.

Indications for Use

Indicated for use as an assayed quality control material to monitor the precision of laboratory testing procedures for cyclosporine, sirolimus, and tacrolimus. Intended for prescription use in clinical laboratory settings.

Regulatory Classification

Identification

A clinical toxicology control material is a device intended to provide an estimation of the precision of a device test system and to detect and monitor systematic deviations from accuracy resulting from reagent or instrument defects. This generic type of device includes various single, and multi-analyte control materials.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ K051074 This summary of 510(k) safety and effectiveness information is submitted in accordance with the requirements of SMDA 1990 and 21 CFR 807.92. #### 510(k) Number: #### Submitter: Microgenics Corporation 46360 Fremont Blvd Fremont, CA 94538 Telephone: (510)-979-5000 #### Contact Person: Lisa Charter Research and Development 46360 Fremont Blvd. Telephone: (510)-979-5142 Facsimile: (510) 979-5455 ## Preparation Date: April 25, 2005 #### Device Information: | Device Classification Name: | Drug Specific Control Materials | |-----------------------------|--------------------------------------| | Common/Usual Name: | Immunosuppressive Drug Control | | Proprietary Name: | MAS® Immunosuppressant Controls | | Regulation Number: | 21 CFR§862.3280 | | Regulatory Name: | Clinical toxicology control material | | Product Code: | LAS | | Regulatory Class: | Class I | ## Predicate Devices: Lyphochek® Whole Blood Control (K022041) manufactured by Bio-Rad Laboratories. ## Device Description: MAS Immunosuppressant Controls is prepared from human whole blood, with pure chemicals and stabilizers. The control is provided in a liquid form containing Cyclosporine, Sirolimus, and Tacrolimus. #### Intended Use: The MAS Immunosuppressant Controls, consisting of levels 1 through 3, are in-vitro diagnostic medical devices intended for use as assayed quality control material to monitor the precision of laboratory testing procedures for cyclosporine, sirolimus, and tacrolimus. {1}------------------------------------------------ # Comparison to Predicate Device(s): The Microgenics Cyclosporine Controls are substantially equivalent to Lyphochek® Whole Blood States and Children of States Also Die Rodd Charatariae The Microgenios Oyeloopenhoed by Bio-Rad Laboratories. | Device | Subject Device | Predicated Device | |--------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | Characteristics | | (K022041) | | Intended Use | The MAS<br>Immunosuppressant<br>Controls, consisting<br>of levels 1 through<br>3, are in-vitro<br>diagnostic medical<br>devices intended for<br>use as assayed<br>quality control<br>material to monitor<br>the precision of<br>laboratory testing<br>procedures for<br>cyclosporine,<br>sirolimus, and<br>tacrolimus. | Lyphochek® Whole<br>Blood Control is<br>intended for use as<br>an assayed quality<br>control material to<br>monitor the<br>precision of<br>laboratory testing<br>procedures for<br>cyclosporine, lead,<br>red cell folate,<br>tacrolimus, and<br>sirolimus. | | Matrix | Processed Human<br>Whole Blood | Processed Human<br>Whole Blood | | Form | Liquid | Lyophilized | | Analytes | Cyclosporine,<br>Sirolimus,<br>Tacrolimus | Cyclosporine,<br>Lead, Red Cell<br>Folate, Tacrolimus,<br>Sirolimus | | Levels | Three (3) Levels | Three (3) Levels | | Open Vial<br>Claim | 14 days at 2°C to<br>8°C | 14 days at 2°C to<br>8°C. Exception:<br>Red cell folate is<br>stable for 3 days at<br>2°C to 8°C | | Storage | -20°C until<br>expiration date | 2°C to 8°C until<br>expiration date | | Stability | Until expiration date<br>noted on vial label. | Until expiration<br>date noted on vial<br>label. | {2}------------------------------------------------ #### Summary: The information provided in this pre-market notification demonstrates that the MAS Immunosuppressant Controls are substantially equivalent to the previously cleared predicate devices. Substantial equivalence was demonstrated through comparison of intended use and physical properties to commercially available devices. The information supplied in this premarket notification provides reasonable assurance the MAS Immunosuppressant Controls are safe and effective for the stated intended use. MAS® is a registered trademark of Medical Analysis Systems, Inc. {3}------------------------------------------------ DEPARTMENT OF HEALTH & HUMAN SERVICES Image /page/3/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a stylized eagle or bird-like figure with three curved lines representing its wings or body. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES USA" is arranged in a circular fashion around the bird-like figure. Food and Drug Administration 2098 Gaither Road Rockville MD 20850 JUN 6 - 2005 Ms. Lisa Charter Research and Development Microgenics Corporation 46360 Fremont Blvd Fremont, CA 94538 k051074 Re: Trade/Device Name: MAS Immunosuppressant Controls Regulation Number: 21 CFR 862.3280 Regulation Name: Clinical toxicology control material Regulatory Class: Class I Product Code: LAS Dated: April 25, 2005 Received: April 29, 2005 Dear Ms. Charter: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in Title 21, Code of Federal Regulations (CFR), Parts 800 to 895. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Parts 801 and 809); and good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820). {4}------------------------------------------------ #### Page 2 – This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific information about the application of labeling requirements to your device, or questions on the promotion and advertising of your device, please contact the Office of In Vitro Diagnostic Device Evaluation and Safety at (240) 276-0484. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html. Sincerely yours, Carol C. Benem Carol C. Benson, M.A. Acting Director Division of Chemistry and Toxicology Office of In Vitro Diagnostic Device Evaluation and Safety Center for Devices and Radiological Health Enclosure {5}------------------------------------------------ # Indications for Use 510(k) Number (if known): Kos S 10 7 4 Device Name: MAS Immunosuppressant Controls Indications For Use: The MAS Immunosuppressant Controls, consisting of levels 1 through 3, are in-vitro The MAG inimal our less intended for use as assayed quality control material to ulughoutio modifical us no folaboratory testing procedures for cyclosporine, sirolimus, and tacrolimus. X Prescription Use (Part 21 CFR 801 Subpart D) AND/OR Over-The-Counter Use _ (21 CFR 807 Subpart C) (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of In Vitro Diagnostic Devices (OIVD) Q. Chalu Division Sign-Off Office of In Vitro Diagnostic Device Evaluation and Safety 510(k) K051074 Page 1 of ____________________________________________________________________________________________________________________________________________________________________