BRAHMS DIAGNOSTICA LUMITEST TRAK HUMAN

K033454 · Brahms Diagnostica, LLC · JZO · Mar 22, 2004 · Immunology

Device Facts

Record IDK033454
Device NameBRAHMS DIAGNOSTICA LUMITEST TRAK HUMAN
ApplicantBrahms Diagnostica, LLC
Product CodeJZO · Immunology
Decision DateMar 22, 2004
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 866.5870
Device ClassClass 2

Intended Use

LUMItest TRAK human is a luminescence receptor assay (LRA) for the quantitative determination of antibodies against the human thyrotropin (TSH) receptor. The measurement of TSH receptor autoantibodies is used in the assessment of patients with suspect Graves' disease (autoimmune hyperthyroidism).

Device Story

LUMItest TRAK human is a luminescence receptor assay (LRA) used for the quantitative measurement of TSH receptor autoantibodies. The device is intended for use in clinical laboratory settings to assist in the assessment of patients suspected of having Graves' disease. By detecting these autoantibodies, the assay provides diagnostic information to healthcare providers, aiding in the clinical evaluation and management of autoimmune hyperthyroidism.

Clinical Evidence

No clinical data provided in the document; the submission relies on the determination of substantial equivalence to legally marketed predicate devices.

Technological Characteristics

Luminescence receptor assay (LRA) for quantitative determination of TSH receptor autoantibodies. Classified as a thyroid autoantibody immunological test system (21 CFR 866.5870), Class II, Product Code JZO.

Indications for Use

Indicated for the quantitative determination of TSH receptor autoantibodies in patients suspected of having Graves' disease (autoimmune hyperthyroidism).

Regulatory Classification

Identification

A thyroid autoantibody immunological test system is a device that consists of the reagents used to measure by immunochemical techniques the thyroid autoantibodies (antibodies produced against the body's own tissues). Measurement of thyroid autoantibodies may aid in the diagnosis of certain thyroid disorders, such as Hashimoto's disease (chronic lymphocytic thyroiditis), nontoxic goiter (enlargement of thyroid gland), Grave's disease (enlargement of the thyroid gland with protrusion of the eyeballs), and cancer of the thyroid.

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ Image /page/0/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular seal with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. Inside the circle is an abstract symbol resembling an eagle or bird in flight, composed of three curved lines. Food and Drug Administration 2098 Gaither Road Rockville MD 20850 Mr. William G. Frank BRAHMS Diagnostica, LLC. 35-B South Peachtree Street Norcross, GA 30071 Re: k033454 Trade/Device Name: LUMItest TRAK human Regulation Number: 21 CFR 866.5870 Regulation Name: Thyroid autoantibody immunological test system Regulatory Class: Class II Product Code: JZO Dated: January 19, 2004 Received: January 21, 2004 Dear Mr. Frank: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. MAR 2 2 2004 If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in Title 21, Code of Federal Regulations (CFR), Parts 800 to 895. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Parts 801 and 809); and good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820). {1}------------------------------------------------ Page 2 This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific information about the application of labeling requirements to your device, or questions on the promotion and advertising of your device, please contact the Office of In Vitro Diagnostic Device Evaluation and Safety at (301) 594-3084. Also, please note the regulation entitled. "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html. Sincerely yours. Joseph L. Hackett Joseph L. Hackett, Ph.D. Acting Director Division of Immunology and Hematology Office of In Vitro Diagnostic Device Evaluation and Safety Center for Devices and Radiological Health Enclosure {2}------------------------------------------------ - 1. Indications for Use Statement ## 510(k) Number (if known): Northown Ko3 3454 Device Name: LUMItest TRAK human Indications For Use LUMItest TRAK human is a luminescence receptor assay (LRA) for the quantitative determination of antibodies against the human thyrotropin (TSH) receptor. The measurement of TSH receptor autoantibodies is used in the assessment of patients with suspect Graves' disease (autoimmune hyperthyroidism). (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED) ______________________________________________________________________________________________________________________________________________________________________________ Concurrence of CDRH, Office of Device Evaluation (ODE) ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ Prescription Use ______________________________________________________________________________________________________________________________________________________________________________ OR Over-The-Counter Use P. Reeves for M. Chan Division Sign-Off Office of In Vitro Diagnostic Device Evaluation and Safety 510(k)K033454
Innolitics
510(k) Summary
Decision Summary
Classification Order
Enter a record ID and click Load to view the document.