PROSONIC ULTRAVIOLET TOOTHBRUSH SANITIZER
K023662 · Hwadong International Company , Ltd. · MCF · May 28, 2003 · Dental
Device Facts
| Record ID | K023662 |
| Device Name | PROSONIC ULTRAVIOLET TOOTHBRUSH SANITIZER |
| Applicant | Hwadong International Company , Ltd. |
| Product Code | MCF · Dental |
| Decision Date | May 28, 2003 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 872.6855 |
| Device Class | Class 1 |
| Attributes | Therapeutic |
Intended Use
The proSonic Ultraviolet Toothbrush Sanitizer is intended for use in reducing bacterial contamination that naturally accrues on toothbrushes under normal conditions of use.
Device Story
Device sanitizes toothbrushes via ultraviolet (UV) radiation; unit houses UV lamp; toothbrushes hung inside. Operation: initial 1-hour cycle; built-in timer cycles lamp (5 minutes ON, 60 minutes OFF) between brushing cycles; total daily activation ~165 minutes. Safety features: UV lamp activates only when door is fully closed; ozone emissions within FDA limits. Sold with four toothbrushes and power handgrip. Used in home environment by consumers. Reduces bacterial load on toothbrush bristles; benefits patient by maintaining cleaner oral hygiene tools.
Clinical Evidence
Bench testing only. Laboratory and actual use tests conducted to evaluate bacterial reduction efficacy and ozone emission levels. Results demonstrated significant reduction in bacterial contamination and ozone emissions within limits specified at 21 C.F.R. § 801.415.
Technological Characteristics
Ultraviolet (UV) radiation sanitization; UV lamp with 10,000-hour effective life. Safety interlock prevents activation when door is open. Ozone emission control compliant with 21 C.F.R. § 801.415. Standalone unit powered by electrical source.
Indications for Use
Indicated for reducing bacterial contamination on toothbrushes under in-use conditions for general population users.
Regulatory Classification
Identification
A manual toothbrush is a device composed of a shaft with either natural or synthetic bristles at one end intended to remove adherent plaque and food debris from the teeth to reduce tooth decay.
Predicate Devices
- Purebrush Ultraviolet Toothbrush Sanitizer (Purebrush Associates)
Related Devices
- K992435 — BACTI-STOP TOOTHBRUSH CLEANER AND SANITIZER · Azo Enterprises · Oct 15, 1999
- K021258 — GERM TERMINATOR GT 100 TOOTHBRUSH SANITIZER · Germ Terminator Corporation · May 10, 2002
- K012914 — SONICWAVE SONIC PLAQUE REMOVER · Homedics, Inc. · Oct 1, 2001
- DEN190039 — ToothWave · Home Skinovations , Ltd. · Sep 17, 2020
- K022900 — BUTLER GUM VARI-CLEAN POWER TOOTHBRUSHES · John O. Butler Co. · Nov 14, 2002
Submission Summary (Full Text)
{0}------------------------------------------------
Image /page/0/Picture/1 description: The image shows the seal of the Department of Health and Human Services (HHS). The seal features a stylized eagle with three human profiles incorporated into its design. The words "DEPARTMENT OF HEALTH AND HUMAN SERVICES. USA" are arranged in a circular pattern around the eagle.
Public Health Service
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
OCT 1 8 2005
Hwadong International Company Limited C/O Ms. Marian Cochran Atico International USA, Incorporated 501 South Andrews Avenue Ft. Lauderdale, Florida 33301
Re: K023662
Trade/Device Name: Prosonic™ Ultraviolet Toothbrush Sanitizer Regulation Number: 21 CFR 872.6855 Regulation Name: Manual Toothbrush Regulatory Class: I Product Code: MCF Dated: February 25, 2003 Received: March 5. 2003
Dear Ms. Cochran:
This letter corrects our substantially equivalent letter of May 28, 2003.
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
{1}------------------------------------------------
Page 2 - Ms. Cochran
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (sections 531-542 of the Act); 21 CFR 1000-1050.
This letter will allow you to continue marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (240) 276-0115. Also, please note the regulation entitled. "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html
Sincerely yours.
Suser Junar
Chiu Lin, Ph.D.
Director Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health
ళాని విద్యా
Enclosure
{2}------------------------------------------------
K 023662
#### Safety and Effectiveness Summary VIII.
| Submitter: | Hwadong International Company, Ltd.<br>#298-12, Kongse-Ri<br>Kieheung-Eup, Yongin-City<br>Kyungki-Do<br>Korea |
|-------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Official Correspondent: | Marian Harding Cochran, Esq.<br>Atico International USA, Inc.<br>501 S. Andrews Avenue<br>Ft. Lauderdale, FL 33301<br>Phone: (954) 779-2500, Ext. 540<br>Fax: (954) 779-3901 |
| Date Summary Prepared: | October 10, 2002 |
| Device Trade Name: | proSonic™ Ultraviolet Toothbrush Sanitizer |
| Device Common Name: | Ultraviolet Toothbrush Sanitizer |
| Predicate Device: | Purebrush Ultraviolet Toothbrush Sanitizer (Purebrush<br>Associates) |
#### Summary of Device Description:
The proSonic Ultraviolet Toothbrush Sanitizer unit sanitizes toothbrushes hung inside the unit by reducing the amount of bacteria that accrues on them under normal conditions of use. Sanitization is accomplished via ultraviolet (UV) radiation produced by a UV lamp housed within the unit. When activated, the proSonic Ultraviolet Toothbrush Sanitizer completes an initial sanitization cycle in one (1) hour. Afterwards, a built-in timer in the unit alternately causes the UV lamp to be turned off for sixty (60) minutes and turned on for five (5) minutes in between brushing cycles. Depending on usage, the UV lamp will typically be activated for approximately one hundred-sixty five (165) minutes per day. The bulb has an effective Iife of ten thousand (10,000) hours. The sanitizer is designed so that the UV lamp can be activated only when the unit door is fully closed, and the level of ozone emitted by the sanitizer is within FDA regulatory limits. The proSonic Ultraviolet Toothbrush Sanitizer is sold with four (4) accompanying toothbrushes and a power handgrip (which converts the toothbrushes into powered toothbrushes).
#### Intended Use:
The proSonic Ultraviolet Toothbrush Sanitizer is intended for use in reducing bacterial contamination that naturally accrues on toothbrushes under normal conditions of use.
{3}------------------------------------------------
## Substantial Equivalence Comparison:
The proSonic Ultraviolet Toothbrush Sanitizer is substantially equivalent to the Purebrush Ultraviolet Toothbrush Sanitizer. The intended use of both devices is identical - to reduce bacterial contamination that accrues on toothbrushes under normal conditions of use. [Both devices are substantially equivalent in terms of materials and design.] Additionally, the technological characteristics of both devices are substantially equivalent. Both the proSonic and the Purebrush sanitizers use ultraviolet light to reduce bacterial contamination. Both devices house a UV lamp that effectively eliminates most bacteria on toothbrushes stored therein. Ozone emissions for the two devices are similar and comply with acceptable FDA regulatory limits. The UV lamps in both devices cannot be activated unless the units are fully closed. The wavelengths emitted by the UV bulbs in the two devices are also substantially equivalent. Additionally, although their sanitization cycle lengths and the lifetimes of their respective UV bulbs are different, these differences are not significant to the safety or effectiveness of the proSonic device. Like the Purebrush, the proSonic UV toothbrush sanitizer is safe and effective for toothbrush sanitization.
# Summary of Performance Testing:
Laboratory and actual use tests were conducted to demonstrate the effectiveness of the proSonic Ultraviolet Toothbrush Sanitizer in reducing bacterial contamination on toothbrushes, as well as the extent to which the device emits ozone. These tests demonstrate that bacterial contamination on toothbrushes is significantly reduced by the device and that the ozone emitted by this product is minimal and within limits specified at 21 C.F.R. § 801.415 (2002).
### Conclusion:
Based on the comparison of features of the proSonic and Purebrush UV sanitizers and the performance testing discussed above, it is concluded that the proSonic Ultraviolet Toothbrush Sanitizer is as safe, as effective, and performs as well as or better than the Purebrush Predicate Device for the intended use of reducing bacterial contamination on toothbrushes, and is thus substantially equivalent thereto.
{4}------------------------------------------------
# Indications for Use Statement
Page 1 of 1
510(k) Number (if known): K023662
Device Name: Prosonic™ Ultraviolet Toothbrush Sanitizer
Indications for Use:
The Prosonic™ Ultraviolet Toothbrush Sanitizer is intended for use in reducing bacterial contamination that naturally accrues on toothbrushes under in-use conditions.
TMTrademark of Hwadong International Company Ltd.
PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED
Concurrence of CDRH, Office of Device Evaluation (ODE)
Prescription Use (Per 21 CFR 801.109 OR
Over-the-Counter Use _XX_ (Optional Format 1)
Dr. Robt. Betz DDS for Dr. K. Mulvey
v. General Hospital. Division of Anesthesiolog Infection Control, Den
510(k) Number: K023662