510(k) Data Aggregation

    K Number
    K201222

    Validate with FDA (Live)

    Date Cleared
    2021-02-11

    (281 days)

    Product Code
    Regulation Number
    872.3820
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    • · Furcation or root perforation treatment via canal;
    • · Furcation or root perforation treatment via surgical;
    • · Internal reabsorption treatment via canal or surgical;
    • · External reabsorption treatment;
    • · Retrofilling in parendodontic surgery;
    • · Direct and indirect pulp capping;
      · Apexification;
    • · Apexogenesis and Pulpotomy.
    Device Description

    BIO-C REPAIR ION+ is a bioceramic reparative material ready-to-use suitable for furcation or root perforation treatment via canal, furcation treatment via surgical, internal reabsorption treatment via canal or surgical, external reatment, retrofilling in parendodontic surgery, direct and indirect pulp capping, apexification, apexogenesis and pulpotomy.
    The product is a single paste provided in a syringe with blunt tips to be applied into the root canal system. BIO-C REPAIR ION* is an insoluble and alkaline material, which requires the presence of water to set and harden. The product presents suitable radiopacity, demonstrating adequate physical properties inherent to root repair materials.

    AI/ML Overview

    This document describes the marketing authorization for the Bio-C Repair Ion+ dental device. It does not contain information about the acceptance criteria or study details as typically associated with AI/ML-based medical devices. The device is a traditional dental material, not an AI or ML product. Therefore, I cannot provide an answer that includes details such as sample sizes for test and training sets, expert qualifications, adjudication methods, MRMC studies, or standalone algorithm performance.

    However, I can extract the information relevant to the non-clinical performance testing conducted for this device.

    1. Table of Acceptance Criteria and Reported Device Performance

    TestAcceptance Criteria (Internal/ISO Standard)Reported Device Performance for BIO-C REPAIR ION+
    Physical/Chemical Properties
    Setting Time (ISO 6876:2012)90-120 minutes90-120 minutes
    Solubility (ISO 6876:2012)Not explicitly stated in the document as a numerical acceptance criterion, but implied as meeting the standard's requirements for "insoluble".Meets the standard's requirements for being insoluble
    Radiopacity (ISO 6876:2012)Not explicitly stated as a numerical acceptance criterion in the text, but the reported performance for the predicate deviceBIO-C SEALER ION+ is "≥ 7 mm Al," and for BIO-C REPAIR and BIO-C REPAIR ION+ it's "~ 7 mm Al". It is implied that BIO-C REPAIR ION+ meets comparable radiopacity.~ 7 mm Al
    InjectabilityIncorporated into product acceptance criteria (no specific value provided).Test performed and reported to meet criteria.
    X-ray diffractionIncorporated into product acceptance criteria (no specific details provided).Test performed and reported to meet criteria.
    Particle size distributionIncorporated into product acceptance criteria (no specific details provided).Test performed and reported to meet criteria.
    Color determination analysesIncorporated into product acceptance criteria (no specific details provided).Test performed and reported to meet criteria.
    pH> 10> 10
    Biocompatibility (ISO 10993-1:2009)
    SensitizationNon-sensitizingNon-sensitizing
    IrritationNon-irritantNon-irritant to oral mucosa of hamsters
    Mutagenicity (Genotoxicity)Non-mutagenic and did not induce genotoxic effects to bone marrow cells of mice. (This refers to data from predicate devices, which is deemed sufficient due to compositional similarity.)Met requirements, based on predicate device data.
    Acute Systemic ToxicityAbsence of acute systemic toxicity after single oral administration. (This refers to data from predicate devices, which is deemed sufficient due to compositional similarity.)Met requirements, based on predicate device data.
    Local and Systemic Toxic Effects upon ImplantationDid not demonstrate local and systemic toxic effects when implanted. (This refers to data from predicate devices, which is deemed sufficient due to compositional similarity.)Met requirements, based on predicate device data.
    Overall BiocompatibilityBiocompatible according to ISO 10993-1:2009Biocompatible according to ISO 10993-1:2009

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    This information is not provided in the document as it pertains to a traditional material device, not software, AI, or ML. The document refers to "extensive bench testing" and biological evaluations according to ISO standards, which typically involve specific numbers of samples or animals as defined by those standards. The data provenance (country of origin or retrospective/prospective nature) is not specified.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    This is not applicable as the document describes a material device and evaluates its physical, chemical, and biological properties, not diagnostic or predictive performance requiring expert ground truth setting like an AI/ML device.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    Not applicable for a physical material device.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This device is a dental material, not an AI or ML system intended to assist human readers.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Not applicable. This device is a dental material.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    For the non-clinical tests, the "ground truth" is defined by the objective measurements and methodologies outlined in the ISO standards (ISO 6876:2012 for physical properties and ISO 10993-1:2009 for biocompatibility). For example, setting time is measured by a specific physical method, and cytotoxicity is assessed via laboratory assays, not expert consensus or pathology in a clinical setting.

    8. The sample size for the training set

    Not applicable for a physical material device.

    9. How the ground truth for the training set was established

    Not applicable for a physical material device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K190537

    Validate with FDA (Live)

    Date Cleared
    2019-12-12

    (283 days)

    Product Code
    Regulation Number
    872.3820
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    1. Sealing the root canal of permanent teeth;

    2. Internal reabsorption treatment;

    Device Description

    BIO-C SEALER ION* is a ready-to-use injectable bioceramic root canal sealer, developed for sealing the root canals and for the treatment of internal reabsorption. The product is a single paste provided in a syringe with disposable intracanal tips to be applied directly into the root canal system. BIO-C SEALER ION* is an insoluble and alkaline material, which requires the presence of water to set and harden. The product presents suitable radiopacity, demonstrating adequate physical properties inherent to root canal sealer materials.

    AI/ML Overview

    The document describes the non-clinical performance testing for the BIO-C SEALER ION+ device. Here is the requested information:

    1. Table of Acceptance Criteria and Reported Device Performance:

    The document doesn't provide a direct table of acceptance criteria versus reported performance for each specific test. Instead, it states that tests were performed "according to ISO 6876:2012 Dental root canal sealing materials" and that "additional tests are also performed and incorporated into the product acceptance criteria." For biocompatibility, it states the device "has met the requirements." Based on the comparison table and the text, we can infer some details.

    Acceptance Criteria (Implied / Stated)Reported Device Performance (BIO-C Sealed ION+)
    Physical/Chemical Properties (ISO 6876:2012)
    Setting time (range)120-240 minutes (Equivalent to predicate K172701)
    SolubilityTested according to ISO 6876:2012 (Insoluble, similar to predicates)
    FlowTested according to ISO 6876:2012 (Comparable to predicate K172701)
    Film thicknessTested according to ISO 6876:2012 (Comparable to predicate K172701)
    Radiopacity$\ge 7$ mm Al (Equivalent to predicate K172701)
    Additional Tests (Incorporated into acceptance criteria)
    X-ray diffraction analysisPerformed
    Particle size analysisPerformed
    Viscosity and thixotropy testsPerformed
    Color determination analysisPerformed
    Biocompatibility (ISO 10993-1:2009)
    Non-mutagenicMet requirements (demonstrated to be non-mutagenic)
    Non-irritant to oral mucosa of hamstersMet requirements (demonstrated to be non-irritant)
    Non-sensitizingMet requirements (demonstrated no sensitizing effects)
    Absence of acute systemic toxicity after single oral administrationMet requirements (demonstrated absence of acute systemic toxicity)
    pH10.5 (Equivalent to predicate K172701, for which pH is 12.5; within acceptable range for bioceramic sealers, inferred as acceptable although a specific range isn't stated). The document states "Equivalent to BIO-C SEALER" for pH, even though the values are different. This implies the difference is considered acceptable.
    InsolubleStated in Principle of Operation, implying it meets the expectation for root canal sealers.

    2. Sample Size Used for the Test Set and Data Provenance:

    The document explicitly states: "NON-CLINICAL PERFORMANCE TESTING: BIO-C SEALER ION* has undergone extensive bench testing." It lists various tests. However, the exact sample size for each specific test (e.g., how many units were tested for setting time, or how many animals for each biocompatibility test) is not specified in the provided text.

    The data provenance is non-clinical/bench testing and animal testing for biocompatibility. No human data is mentioned. The manufacturer is Angelus Indústria de Produtos Odontológicos S/A, based in Brazil. Therefore, the data provenance for non-clinical testing would be from their labs or contracted facilities. The study is prospective in the sense that the device was specifically tested to meet the standards.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts:

    This section is not applicable to the provided text. The performance assessment relied on established international standards (ISO 6876:2012 for physical/chemical properties and ISO 10993-1:2009 for biocompatibility). These standards define test methodologies and criteria, rather than requiring expert consensus on a test set's ground truth in the way a diagnostic AI tool would. The experts involved would be those performing and interpreting the ISO standard tests, but their specific number or qualifications are not detailed.

    4. Adjudication Method for the Test Set:

    This section is not applicable. Adjudication methods like 2+1 or 3+1 are used for establishing ground truth in clinical studies, particularly for diagnostic devices where multiple human readers assess cases. This document describes non-clinical performance and biocompatibility testing against international standards, not a clinical trial requiring human adjudication of results.

    5. If a Multi Reader Multi Case (MRMC) Comparative Effectiveness Study Was Done, If So, What Was the Effect Size of How Much Human Readers Improve with AI vs Without AI Assistance:

    A Multi Reader Multi Case (MRMC) comparative effectiveness study was not done. The device is a root canal filling material, and the evaluation is non-clinical, focusing on its physical, chemical, and biological properties, not its impact on human reader performance.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done:

    This section is not applicable. The device is a physical dental material, not an algorithm or AI system. Therefore, standalone algorithm performance is not a relevant concept here.

    7. The Type of Ground Truth Used:

    The "ground truth" for the device's performance is established by conformance to international standards (ISO 6876:2012 for dental root canal sealing materials and ISO 10993-1:2009 for biological evaluation of medical devices). For biocompatibility, this means the device did not elicit mutagenic, irritant, sensitizing, or acute systemic toxic effects as defined by the standard's methodologies. For physical properties, it means the device's setting time, solubility, flow, film thickness, and radiopacity fell within the acceptable parameters or demonstrated comparability to predicates as assessed by the standard's tests.

    8. The Sample Size for the Training Set:

    This section is not applicable. The device is a physical medical device, not an AI/ML algorithm that requires a training set.

    9. How the Ground Truth for the Training Set Was Established:

    This section is not applicable as there is no training set for a physical medical device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K180199

    Validate with FDA (Live)

    Device Name
    BIO-C TEMP
    Date Cleared
    2019-01-04

    (345 days)

    Product Code
    Regulation Number
    872.3820
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    • Intracanal dressing for endodontic treatment of pulp necrosis and retreatments.
    • Intracanal dressing in cases of perforations, external and internal resorptions, prior to the use of MTA ANGELUS OR MTA REPAIR HP.
    • For the treatment of incomplete root formation (rizogenesis):
      Apexification - the formation of the apex in cases of pulp necrosis;
      Apexigenesis - the formation of the apex in cases of vital pulp.
    Device Description

    Not Found

    AI/ML Overview

    The provided text does not contain any information about acceptance criteria or a study proving that a device meets acceptance criteria. The document is an FDA clearance letter for a dental device called "BIO-C TEMP," which is a root canal filling resin.

    The letter primarily covers:

    • The FDA's review and determination of substantial equivalence for the device.
    • Regulatory information, including general controls, classification, and applicable regulations.
    • Contact information for FDA resources.
    • The indications for use for the BIO-C TEMP device.

    Therefore, I cannot provide the requested information, including:

    1. A table of acceptance criteria and reported device performance.
    2. Sample size and data provenance for a test set.
    3. Number and qualifications of experts for ground truth establishment.
    4. Adjudication method for a test set.
    5. Results of a multi-reader multi-case (MRMC) comparative effectiveness study.
    6. Results of a standalone algorithm performance study.
    7. Type of ground truth used.
    8. Sample size for the training set.
    9. How ground truth for the training set was established.
    Ask a Question

    Ask a specific question about this device

    K Number
    K180185

    Validate with FDA (Live)

    Device Name
    BIO-C REPAIR
    Date Cleared
    2018-08-31

    (220 days)

    Product Code
    Regulation Number
    872.3820
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Reparative cement for endodontic complications.

    1. Furcation or root perforation treatment via canal;
    2. Furcation or root perforation treatment via surgical;
    3. Internal reabsorption treatment via canal or surgical;
    4. External reabsorption treatment;
    5. Retrofilling in parendodontic surgery;
    6. Direct and indirect pulp capping;
    7. Apexification;
    8. Apexogenesis and Pulpotomy.
    Device Description

    BIO-C REPAIR is a ready-to-use bioceramic MTA-based paste developed for permanent root canal repair and surgical applications. The product is a single paste provided in a syringe with disposable tips to be applied to the affected area of the root canal system. BIO-C REPAIR is an insoluble and radiopaque material which requires the presence of water to set and harden.

    AI/ML Overview

    The provided document is a 510(k) summary for the dental device BIO-C REPAIR. This document primarily focuses on establishing substantial equivalence to predicate devices based on comparisons of indications for use, technological characteristics, and performance data from bench testing. It does not describe a clinical study directly proving the device meets specific acceptance criteria in a clinical setting in the way an AI/ML device would.

    However, based on the provided text, we can infer the acceptance criteria for various physical-chemical properties and present the reported device performance. No information is available regarding AI/ML specific criteria such as sensitivity, specificity, or accuracy, as this is a dental material, not an AI/ML diagnostic tool.

    Here's the information extracted and formatted as requested:

    1. Table of Acceptance Criteria and Reported Device Performance

    The acceptance criteria are implicitly derived from the ISO 6876:2012 standard for dental root canal sealing materials and the properties of the predicate devices. The "reported device performance" refers to BIO-C REPAIR's measured characteristics.

    Acceptance Criteria (Implicit from ISO 6876:2012 and Predicates)Reported Device Performance (BIO-C REPAIR)
    Non-sterileNon-sterile
    pH > 12pH 12.5
    Setting time ~ 2 hours (predicate reference)Setting time 90 - 120 minutes
    Radiopacity ≥ 7 mm AlRadiopacity ≥ 7 mm Al
    BiocompatibleBiocompatible
    Shelf life 2 yearsShelf life 2 years
    Solubility (in accordance with ISO 6876:2012 established values)Values in accordance with ISO 6876:2012

    2. Sample Size Used for the Test Set and the Data Provenance

    The document does not specify a "test set" in the context of human data or AI/ML model evaluation. The performance data is derived from bench testing of the material itself. Therefore, sample sizes for the bench tests would refer to the number of material samples tested for properties like setting time, pH, radiopacity, and solubility. This information is not provided in the document.

    Data provenance: The testing was performed by the manufacturer, Angelus Indústria de Produtos Odontológicos S/A, based in Londrina, Brazil. The data is from laboratory (bench) testing, not clinical. It is retrospective in the sense that the tests were completed before the 510(k) submission.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and the Qualifications of Those Experts

    This is not applicable as the device is a dental material, not an AI/ML diagnostic device requiring expert interpretation for ground truth establishment. The "ground truth" for the material's properties is established through adherence to international standards (ISO 6876:2012) and comparison to predicate devices, not expert consensus on medical images or clinical outcomes.

    4. Adjudication Method for the Test Set

    This is not applicable as there is no "test set" requiring adjudication in the context of human expert review for a dental material. The performance measurements are objective laboratory tests.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done, If So, What Was the Effect Size of How Much Human Readers Improve with AI vs Without AI Assistance

    This is not applicable. The device is a dental filling material, not an AI-assisted diagnostic tool.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done

    This is not applicable. The device does not involve an algorithm or AI.

    7. The Type of Ground Truth Used

    The "ground truth" for the properties of BIO-C REPAIR is established by objective laboratory measurements according to an international standard (ISO 6876:2012) and comparison to the characteristics reported for legally marketed predicate devices. This is analogous to "physical and chemical properties" ground truth.

    8. The Sample Size for the Training Set

    This is not applicable as the device is not an AI/ML model and therefore does not have a "training set."

    9. How the Ground Truth for the Training Set Was Established

    This is not applicable. There is no training set for this type of device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K172701

    Validate with FDA (Live)

    Device Name
    BIO-C SEALER
    Date Cleared
    2018-01-04

    (119 days)

    Product Code
    Regulation Number
    872.3820
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
      1. Sealing the root canal of permanent teeth;
      1. Internal reabsorption treatment.
    Device Description

    BIO-C SEALER is a ready-to-use injectable endodontic bioceramic sealer, suitable for obturation of root canals.

    AI/ML Overview

    The provided text describes a 510(k) premarket notification for a dental device called BIO-C SEALER. This type of submission focuses on demonstrating substantial equivalence to a legally marketed predicate device rather than providing clinical efficacy studies with specific acceptance criteria as might be found for a novel device or drug.

    Therefore, the supplied text does not contain the information requested regarding:

    • A table of acceptance criteria and reported device performance in a clinical context. The performance data is for physical-chemical properties to show equivalence to the predicate.
    • Sample size used for a test set (clinical data).
    • Data provenance for a test set (clinical data).
    • Number of experts used to establish ground truth or their qualifications.
    • Adjudication method for a test set.
    • Multi-reader multi-case (MRMC) comparative effectiveness study.
    • Standalone performance (algorithm only without human-in-the-loop performance).
    • Type of ground truth used (expert consensus, pathology, outcomes data, etc.) for clinical efficacy.
    • Sample size for a training set (clinical data).
    • How ground truth for the training set was established (clinical data).

    Instead, the document highlights non-clinical (bench) testing to support substantial equivalence.

    Here's what can be extracted from the document regarding "performance criteria" in the context of a 510(k) and the "study" (bench tests) that proves them:

    1. A table of acceptance criteria and the reported device performance

    The document states: "BIO-C SEALER has undergone extensive bench testing to provide evidence that its physical-chemical properties are substantially equivalent to iRoot SP. Bench tests performed are: flow, setting time, film thickness, solubility and radiopacity. Both devices have comparable flowability, setting time, film thickness, solubility and radiopacity."

    This implies that the acceptance criteria for BIO-C SEALER's physical-chemical properties were to demonstrate comparability or substantial equivalence to the predicate device (iRoot SP) for these specific metrics. The reported performance is that they are comparable.

    Acceptance Criteria (Implicit)Reported Device Performance (BIO-C SEALER)
    Flow: Comparable to iRoot SPAchieved comparability
    Setting Time: Comparable to iRoot SPAchieved comparability
    Film Thickness: Comparable to iRoot SPAchieved comparability
    Solubility: Comparable to iRoot SPAchieved comparability
    Radiopacity: Comparable to iRoot SPAchieved comparability
    Biocompatibility: Non-mutagenic, does not cause allergenic potential, good tolerance.Achieved (product is non-mutagenic, does not cause an allergenic potential after multiple uses and has a good tolerance)

    2. Sample sized used for the test set and the data provenance

    • Sample size: Not specified. The document only mentions "extensive bench testing." The sample size would refer to the number of samples of the material tested for each physical-chemical property.
    • Data provenance: Bench test results; conducted by Angelus Indústria de Produtos Odontológicos S/A. It's non-clinical, so country of origin for patients/data is not relevant.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    Not applicable. This was bench testing of physical properties, not a clinical study requiring expert ground truth.

    4. Adjudication method for the test set

    Not applicable. This was bench testing.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This is a dental material, not an AI diagnostic device.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Not applicable. This is a dental material, not an AI algorithm.

    7. The type of ground truth used

    For physical-chemical properties, the "ground truth" is measured by standard laboratory methods according to relevant ISO or ASTM standards, against which the test device's performance is compared to the predicate device's established performance or regulatory requirements. For biocompatibility, the ground truth would be established by validated tests for mutagenicity, allergenicity, and general tolerance.

    8. The sample size for the training set

    Not applicable. This device does not use machine learning or require a training set.

    9. How the ground truth for the training set was established

    Not applicable. This device does not use machine learning or require a training set.

    Ask a Question