Search Filters

Search Results

Found 50 results

510(k) Data Aggregation

    K Number
    K241626

    Validate with FDA (Live)

    Date Cleared
    2025-02-20

    (259 days)

    Product Code
    Regulation Number
    884.6160
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    TAIWAN

    Re: K241626

    Trade/Device Name: SperSort™ Sperm Sorting Chip (IPG02) Regulation Number: 21 CFR 884.6160
    |
    | Regulation Number: | 21 CFR 884.6160

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The SperSort™ Sperm Sorting Chip is intended for preparing motile sperm from semen for use in the treatment of infertile couples by intracytoplasmic sperm injection (ICSI), in vitro fertilization (IVF) and intrauterine insemination (IUI) procedures.

    Device Description

    The SperSort™ Sperm Sorting Chip is used to prepare motile sperm for assisted reproductive technology (ART) procedures. The device separates motile sperm from the semen based on the mobility (i.e., swim-up nature) of motile sperm. The SperSort™ Sperm Sorting Chip consists of an upper collection chamber and a lower semen sample chamber. The chambers are separated by porous filter which allow motile sperm to pass from the lower chamber to the upper chamber. Both the semen sample injection port and sperm collection port are located on the upper cover. The semen sample injection port directly connects to the lower chamber, while the sperm collection port is connected to the upper chamber. The SperSort™ Sperm Sorting Chip accommodates a 1.9 mL semen sample. Liquefied semen is added to the lower chamber and cleared sperm washing medium (1.5 mL) is added to the upper chamber. Following incubation for 30 minutes at 37°C, the isolated sperm are gathered from the collection port. The SperSort™ Sperm Sorting Chip is a radiation-sterilized device with a sterility assurance level (SAL) of 10-9. They are individually packaged and for single use only.

    AI/ML Overview

    The FDA 510(k) summary for the SperSort™ Sperm Sorting Chip (IPG02) provides information on its acceptance criteria and non-clinical performance testing.

    1. Table of Acceptance Criteria and Reported Device Performance

    The acceptance criteria are not explicitly stated in a single table, but can be inferred from the performance testing section and comparison with the predicate device.

    Performance MetricAcceptance Criteria (Implied)Reported Device Performance (SperSort™ Sperm Sorting Chip)
    Sterility Assurance Level (SAL)10⁻⁶ (as per predicate device and FDA guidance)10⁻⁶
    Package IntegrityMaintain sterile barrier after simulated transport and agingPassed (Can withstand shipping, sterile barrier maintained)
    Shelf-Life Performance (HSSA)≥ 80% of the control motility at 24 hours after exposure for 30 minutesMaintained performance after two years accelerated aging and passed HSSA (≥ 80% control motility)
    Endotoxin≤ 20 EU/device (device specific)< 20 EU/device
    % Motile Sperm (after separation)Significantly increased compared to input (demonstrating efficacy)95.89% (from 57.50% before separation)
    % Progressive Motile Sperm Cells (PMSC) (after separation)Significantly increased compared to input (demonstrating efficacy)92.97% (from 47.07% before separation)

    2. Sample Size Used for the Test Set and Data Provenance

    The document does not explicitly state the sample size for the test set used in the performance testing.
    The data provenance is not specified. It is unclear if the data is from a particular country or if it's retrospective or prospective. The study is described as "Performance Testing" using "donor semen samples," implying a prospective study, but details are lacking.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts

    This information is not provided in the document. The performance testing primarily focuses on device output measurements (% motile sperm, % progressive motile sperm) rather than expert-adjudicated ground truth for a diagnostic interpretation.

    4. Adjudication Method for the Test Set

    This information is not provided as the testing described focuses on quantitative measurements of sperm characteristics rather than qualitative assessments requiring adjudication.

    5. If a Multi Reader Multi Case (MRMC) Comparative Effectiveness Study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    The SperSort™ Sperm Sorting Chip is a physical device for processing semen samples, not an AI software/algorithm for interpretation. Therefore, a Multi-Reader Multi-Case (MRMC) comparative effectiveness study with human readers assisting AI or vice-versa is not applicable and was not performed.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    The SperSort™ Sperm Sorting Chip is a physical device, not an algorithm or AI. Therefore, a standalone algorithm performance study is not applicable and was not performed. The "standalone" performance in this context refers to the device's ability to separate sperm effectively on its own, which is what the performance testing describes.

    7. The Type of Ground Truth Used

    For the performance testing, the "ground truth" for the effectiveness of sperm separation was established through quantitative measurement of sperm parameters (percentage of total motile sperm and progressively motile sperm cells) in both the input (before separation) and output (after separation) samples. These measurements serve as an objective ground truth for the device's performance in improving sperm quality.

    8. The Sample Size for the Training Set

    The document describes a physical medical device, not an AI or machine learning algorithm that requires a "training set." Therefore, information about a training set size is not applicable and not provided.

    9. How the Ground Truth for the Training Set was Established

    As this is a physical device and not an AI/ML algorithm, the concept of a "training set" and establishing ground truth for it is not applicable.

    Ask a Question

    Ask a specific question about this device

    K Number
    K241454

    Validate with FDA (Live)

    Date Cleared
    2025-02-03

    (257 days)

    Product Code
    Regulation Number
    884.6160
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Straw (MVT-VSN series: MVT-VSNR, MVT-VSNY, MVT-VSNB, MVT-VSNG, MVT-VSNP) Regulation Number: 21 CFR 884.6160
    |

    Regulation Number:21 CFR 884.6160
    Regulation Number21 CFR 884.6160
    21 CFR 884.6160
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Minvitro® Vitrification Straw (MVT-VSN series: MVT-VSNY, MVT-VSNB, MVT-VSNG, MVT-VSNP) is a cryopreservation storage device intended for use in vitrification procedures to contain and maintain human oocytes (MII), 4-8 cell embryos, and blastocyst stage embryos.

    Device Description

    The Minvitro® Vitrification Straw (MVT-VSN series: MVT-VSNR, MVT-VSNY, MVT-VSNB, MVT-VSNG, MVT-VSNP) are intended for use in closed vitrification procedures to contain and maintain human oocytes (MI), 4-8 cell embryos, and blastocyst stage embryos, and they are intended for use in professional healthcare facilities. The subject devices are for single use, disposable and supplied sterile.

    The Minvitro® Vitrification Straws (MVT-VSN series: MVT-VSNR, MVT-VSNY, MVT-VSNB, MVT-VSNG, MVT-VSNP) are all composed of a cap with a balancing head, a handle, a carrier sheet with a fine tip at the end. The oocytes or embryos are loaded on the carrier sheet, and in which, the fine tip of carrier sheet is flat with a triangular-shaped area for oocyte/embryo loading. The subject devices are sterilized using ethylene oxide (EO) to a sterilization assurance level of 106, are singleuse, and have a 2-year shelf-life.

    The subject devices are available in five colors: MVT-VSNR. MVT-VSNY. MVT-VSNB. MVT-VSNG, and MVT-VSNP corresponding to Red, Yellow, Blue, Green, and Purple, respectively, all identical in size.

    AI/ML Overview

    The Minvitro® Vitrification Straw (K241454) is a cryopreservation storage device. It underwent non-clinical performance testing to demonstrate its substantial equivalence to the predicate device, Cryotop® US-flash (K181469).

    Here's an overview of the acceptance criteria and the study that proves the device meets them:

    1. Table of Acceptance Criteria and Reported Device Performance

    Test/CharacteristicAcceptance CriterionReported Device Performance (Minvitro® Vitrification Straw)
    SterilizationSAL of 10⁻⁶ (EO process)Validated in accordance with ISO 11135:2014, ISO 11607-1-2006/Amd 1-2014, ISO 11607-2-2006/Amd 1-2014, ISO 11737-1:2018, ISO 11737-2:2009, ISO 11138-2:2017, ISO 10993-7:2008/Cor 1-2009.
    Endotoxin≤ 0.5 EU/device< 0.5 EU/device (using Gel-Clot Limulus Amoebocyte Lysate (LAL) method)
    Cooling Rate (closed cap)-3000 °C/min (similar to predicate)Performed within specifications (comparative analysis against predicate K181469)
    Warming Rate (closed cap)40000 °C/min (subject's specific)Performed within specifications (comparative analysis against predicate K181469)
    Mouse Embryo Assay (MEA)≥ 80% embryos developed to expanded blastocyst at 96 hours (1-Cell System)Met acceptance criterion (testing conducted in accordance with 2021 FDA guidance)
    Package IntegrityMaintain integrity after testingPassed tests as per O F1886/F1886M-16, ASTM F88/F88M-15, ASTM F1929-15.
    Mechanical PerformanceMaintain performancePassed dimensional testing, examination following cryostorage, seal integrity and leakage assessment following cryostorage, capping force and torque testing, uncapping force and torque testing.
    Simulated Transportation & ConditioningMaintain performance after simulationPerformed after accelerated aging per ASTM D4169-22 and environmental conditioning per ASTM D4332-22. Device maintained performance.
    Shelf Life2 yearsDemonstrated after 2-years of accelerated aging per ASTM F1980-21 and simulated transportation/conditioning.

    2. Sample size used for the test set and the data provenance

    The document does not explicitly state the specific numerical sample sizes for each test in the test set. However, it implicitly indicates that sufficient samples were used to perform each test (e.g., "devices" for endotoxin, "embryos" for MEA).

    The information provided suggests the data provenance is from non-clinical laboratory testing. No specific country of origin for the data is mentioned, but the manufacturer is based in Guangzhou, China. The nature of these tests is prospective as they are conducted as part of the submission process to demonstrate device performance.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    The document does not specify the number or qualifications of experts used to establish ground truth for the non-clinical tests. These tests are typically conducted according to established international standards (e.g., ISO, ASTM, USP) and FDA guidance documents, which inherently define the "ground truth" through their methodologies and acceptance criteria. For the Mouse Embryo Assay (MEA), the "ground truth" (i.e., ≥80% blastocyst development) is a predefined industry standard for device suitability in assisted reproduction technology.

    4. Adjudication method for the test set

    Not applicable. The tests described are objective, quantitative laboratory tests with predefined acceptance criteria based on standards. There is no mention of human adjudication for these non-clinical performance studies.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. The device described is a cryopreservation storage device, not an AI-powered diagnostic or imaging device. Therefore, an MRMC study or evaluation of human reader improvement with AI assistance is not relevant.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Not applicable. The device is a physical medical device (vitrification straw), not an algorithm or software. Therefore, standalone algorithm performance is not relevant.

    7. The type of ground truth used

    For the non-clinical performance tests, the "ground truth" is primarily based on:

    • Industry and regulatory standards/guidance: Standards like ISO 11135, ASTM D4169, USP <85>, and FDA guidance for MEA define the acceptable parameters and outcomes for device performance.
    • Predicate device's specifications: For tests like cooling/warming rates, the predicate device's performance characteristics served as a benchmark for comparison.
    • Pre-defined biological endpoints: In the case of the Mouse Embryo Assay, the development of embryos to the blastocyst stage at a certain percentage defines the biological "ground truth" for toxicity and suitability.

    8. The sample size for the training set

    Not applicable. This is not an AI/machine learning device; therefore, there is no "training set" in the context of algorithm development. The tests described are for a physical medical device.

    9. How the ground truth for the training set was established

    Not applicable for the same reason as above.

    Ask a Question

    Ask a specific question about this device

    K Number
    K241348

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-01-31

    (263 days)

    Product Code
    Regulation Number
    884.6160
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Trade/Device Name: SwimCount® Harvester (1 mL); SwimCount® Harvester (3 mL) Regulation Number: 21 CFR 884.6160
    Name: | Assisted Reproduction Labware |
    | Regulation Number: | 24 CFR 884.6160

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The SwimCount® Harvester is intended for preparing motile sperm cells from semen for use in the treatment of infertile couples by Intracytoplasmic Sperm Injection (ICSI), In Vitro Fertilization (IVF) and Intrauterine Insemination (IUI) procedures.

    Device Description

    The SwimCount® Harvester (1 mL and 3 mL) is a sperm separation device used to prepare sperm samples for Assisted Reproductive Technology (ART) procedures. The SwimCount® Harvester separates the sperm sample by allowing motile sperm cells to pass the SwimCount® Harvester's membrane system. The SwimCount® Harvester has a design/technology that utilizes the motility of the sperm cells (i.e. swim-up nature) to separate the motile sperm cells from the rest of the sperm population.

    The SwimCount® Harvester has two processing volumes, 1 mL and 3 mL. The device consists of 3 compartments: 1) Sample compartment (1 mL or 3 mL), 2) Medium/Harvest compartment (0.8 mL for both device versions), and 3) Microporous polycarbonate (PC) filter membrane (10 um pore size).

    Each device version has a Semen Inlet port that communicates with the lower sample compartment. The sample compartment is separated from the upper collection compartment by the microporous filter membrane. Semen is added to the lower compartment through the sample inlet port and cleared sperm separation medium (not provided) is added to the upper collection compartment through the Medium Inlet port. After incubation, the separated motile sperm cells are collected from the upper collection compartment through the Harvest Outlet port and used for subsequent assisted reproduction fertilization procedures.

    The SwimCount® Harvester is supplied to the user as sterile (radiation), with a sterility assurance level of (SAL) of 10 6. The devices are individually packed and for single use only.

    AI/ML Overview

    The provided text describes the 510(k) summary for the SwimCount® Harvester, a device for preparing motile sperm cells. Here's a breakdown of the acceptance criteria and the study proving the device meets them, based on the provided information:

    1. Table of acceptance criteria and the reported device performance

    Acceptance Criteria (from predicate comparison or performance testing)Reported Device Performance
    Endotoxin: < 20 EU/Device (subject device specification)Meets < 20 EU/device (from Endotoxin testing)
    Human Sperm Survival Assay (HSSA): ≥80% of control motility at 24h (subject device specification)Meets ≥80% of control motility at 24h (from HSSA testing)
    Percentage Motile Sperm (1 mL device): Not explicitly stated as criterion, but demonstrated effectivenessBefore separation: 65.4% After separation: 95.1% % change: 45.4%
    Percentage Progressive Motile Sperm Cells (PMSC) (1 mL device): Not explicitly stated as criterion, but demonstrated effectivenessBefore separation: 56.8% After separation: 89.6% % change: 57.8%
    Percentage Motile Sperm (3 mL device): Not explicitly stated as criterion, but demonstrated effectivenessBefore separation: 64.4% After separation: 94.9% % change: 47.4%
    Percentage Progressive Motile Sperm Cells (PMSC) (3 mL device): Not explicitly stated as criterion, but demonstrated effectivenessBefore separation: 54.2% After separation: 89.6% % change: 65.3%
    Sterility: Meets SAL of 10-6Achieved through radiation sterilization validated per ISO 11137-2:2015
    Package Integrity & Transportation following accelerated aging: Meets specified ASTM standardsMeets ASTM standards (referencing F1886/F1886M-16, F1929-15, F88/F88M-21, D4169-22)

    2. Sample size used for the test set and the data provenance

    • Performance testing: n=10 for each device variant (1 mL and 3 mL). This means 10 raw semen samples were processed through the 1mL device, and another 10 raw semen samples through the 3mL device.
    • Data Provenance: The document does not specify the country of origin for the data or whether it was retrospective or prospective.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    • The document does not provide information on the number of experts, their qualifications, or their involvement in establishing ground truth for the performance testing. Quality control or lab personnel would typically perform such assessments.

    4. Adjudication method for the test set

    • The document does not mention any adjudication method for the test set results.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • No, a multi-reader multi-case (MRMC) comparative effectiveness study was not done. This device is a sperm separation device, not an AI-assisted diagnostic tool, so such a study would not be applicable.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    • This device is a physical sperm separation device. Performance testing was done on the device itself, which is inherently a "standalone" or "algorithm-only" in the sense that it performs its function without a human actively making real-time processing decisions or interpretations during its operation. The human element is in its proper use according to the Instructions for Use.

    7. The type of ground truth used

    • For the performance testing, the "ground truth" implicitly refers to the initial assessment of % motile sperm and % progressive motile sperm cells (PMSC) in the raw semen samples before separation, compared to the same metrics in the harvested (processed) output samples. This is a direct measure of the device's functional performance in enriching motile sperm. The specific methodology for these measurements (e.g., manual count, CASA system) is not detailed.
    • For the other tests (Endotoxin, HSSA, Sterilization, Package Integrity), the ground truths are defined by recognized standards and laboratory testing protocols.

    8. The sample size for the training set

    • This information is not applicable as the SwimCount® Harvester is a physical medical device, not a software algorithm that requires a training set.

    9. How the ground truth for the training set was established

    • This information is not applicable as the SwimCount® Harvester is a physical medical device.
    Ask a Question

    Ask a specific question about this device

    K Number
    K241341

    Validate with FDA (Live)

    Date Cleared
    2024-09-26

    (136 days)

    Product Code
    Regulation Number
    884.6160
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    California 92705

    Re: K241341

    Trade/Device Name: cryo-GO Vitrification Device Regulation Number: 21 CFR 884.6160
    |
    | Regulation Number: | 21 CFR 884.6160

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    cryo-GO Vitrification Device is a cryopreservation device intended for use in vitrification procedures to contain and maintain human oocytes (MII), pronuclear (PN) zygotes through day 3 cleavage stage embryos and blastocyst stage embryos.

    Device Description

    The cryo-GO Vitrification Device is a sterile, single-use, closed assisted reproduction storage device for use in vitrification procedures to contain and maintain oocytes (MII), pronuclear (PN) zygotes through day 3 cleavage stage embryos and blastocyst stage embryos.

    The cryo-GO Vitrification Device is composed of an injection molded body with an extended loading tip (4.45 inches long with a 0.65 inch loading tip), an injection molded cap (1.76 inches), and a total device combined length of 5.05 inches. Visible marks are on the distal loading tip, body, and at the opening of the cap, to indicate the location of the tip, the upright orientation of the device and the opening of the cap, respectively. The body and cap include a taper design that create a seal when assembled prior to plunging the device in liquid nitrogen for vitrification and for subsequent storage. The device is provided in five different colors: red, yellow, green, blue, and purple. The subject devices are radiation sterilized to a sterilization assurance level of 10-6 and have a one-year shelflife.

    AI/ML Overview

    A detailed response outlining acceptance criteria and device performance based on the provided text for the cryo-GO Vitrification Device (K241341):

    Acceptance Criteria and Device Performance for cryo-GO Vitrification Device (K241341)

    The provided documentation, a 510(k) Summary, focuses on demonstrating substantial equivalence to a predicate device (VitriGuard, K200815) rather than explicitly stating pre-defined, quantitative acceptance criteria for all aspects of performance with a dedicated clinical study. However, some functional performance criteria are implicitly accepted through comparison with the predicate device or established standards. The non-clinical performance data section presents the studies undertaken to support the device's safety and effectiveness.

    Here’s a breakdown based on the categories requested:

    1. Table of Acceptance Criteria and Reported Device Performance

    Performance Metric/TestAcceptance Criteria (Implicitly Accepted)Reported Device Performance
    SterilitySterility Assurance Level (SAL) of 10⁻⁶ (in accordance with ISO 11137-1:2018, 11137-2:2015, and 2024 FDA guidance)Achieved SAL of 10⁻⁶
    Package Integrity (Shipping)Withstand rigors of shipping and maintain sterile barrier over one-year shelf-life (demonstrated by ASTM D4169-22, visual inspection, ASTM F1929-23, ASTM F88/F88M-21)Devices withstood simulated transportation and maintained sterile barrier, demonstrating the ability to function within the stated shelf-life.
    Shelf Life (General)Maintained performance for newly manufactured and after one year accelerated aging per ASTM F1980-21Devices maintained performance after one year of accelerated aging.
    Cooling Rate(Comparison to predicate: -2,271°C/min; subject device found to have a lower rate but deemed not to raise different S&E questions)-1,650°C/min
    Warming Rate(Comparison to predicate: +36,377°C/min; subject device found to have a lower rate but deemed not to raise different S&E questions)+16,500°C/min
    Dimensional StabilityMaintained dimensions after one year of accelerated aging.Testing confirmed dimensional stability.
    Durability (LN₂ Exposure)No cracks, deformation, discoloration, or other damage after exposure to liquid nitrogen.Testing demonstrated device integrity after LN₂ exposure.
    Seal Integrity/Leakage (LN₂ )No leakage after exposure to liquid nitrogen.Testing confirmed seal integrity and no leakage.
    Capping and De-capping ForceMaintained appropriate force for capping and de-capping after one year of accelerated aging.Testing confirmed acceptable capping and de-capping force.
    Ink Marker ResistanceInk markers remained resistant after one year of accelerated aging.Testing confirmed ink marker resistance.
    Endotoxin Test≤ 2 EU/device (according to USP<85>, <161>)≤ 2 EU/device
    Mouse Embryo Assay (MEA)≥ 80% expanded blastocyst within 96 hours (in accordance with 2021 FDA guidance)≥ 80% expanded blastocyst within 96 hours

    Summary of the Study Proving Device Meets Acceptance Criteria:

    The "cryo-GO Vitrification Device" underwent non-clinical performance testing to demonstrate its safety and effectiveness, supporting its substantial equivalence to the predicate device. The studies were primarily bench testing and in-vitro biological assays.

    2. Sample Size and Data Provenance for Test Set:

    The provided document describes non-clinical performance testing rather than a "test set" in the context of AI/machine learning or a clinical trial with patient data. Therefore, the concept of sample size and data provenance as typically applied to such studies does not directly align.

    • Sample Size: Not explicitly stated as a single "test set" sample size. The testing involved multiple units of the device for various engineering and biological tests (e.g., numerous devices for sterility validation, package integrity, shelf-life testing, and a sufficient number of mouse embryos for the MEA).
    • Data Provenance: The data comes from laboratory testing performed by the manufacturer, FUJIFILM Irvine Scientific, Inc. The nature of the studies implies that they were prospective bench and in-vitro experiments designed to evaluate the device's physical, chemical, and biological performance. There is no indication of country of origin of "data" in the sense of patient data, as this was a non-clinical submission.

    3. Number of Experts and Qualifications for Ground Truth:

    Not applicable. This was a submission for a physical medical device (cryopreservation device), not an AI/software device requiring expert human readers to establish ground truth for image interpretation or diagnosis. The "ground truth" for performance was established through standardized laboratory testing methods (e.g., ISO, ASTM, USP, FDA guidance documents).

    4. Adjudication Method for Test Set:

    Not applicable. As noted above, this was non-clinical bench and in-vitro testing. Adjudication methods like 2+1 or 3+1 are typically used in clinical studies or AI performance evaluations to reconcile discrepancies among human readers or expert panels.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study:

    Not applicable. This device is not an AI algorithm or a diagnostic imaging tool that would involve human readers interpreting cases. Therefore, an MRMC study and analysis of AI assistance improving human readers were not performed.

    6. Standalone (Algorithm Only) Performance:

    Not applicable. The "cryo-GO Vitrification Device" is a physical medical device for cryopreservation, not a software algorithm.

    7. Type of Ground Truth Used:

    The ground truth for evaluating the device's performance was based on:

    • Standardized Laboratory Test Results: Measurements and observations against established industry standards (e.g., ISO 11137 for sterility, ASTM standards for package integrity and accelerated aging, USP<85> for endotoxin).
    • Biological Activity/Functionality: The Mouse Embryo Assay (MEA) provides a biological "ground truth" for the device's non-toxicity and suitability for embryo culture, as defined by the "≥ 80% expanded blastocyst within 96 hours" criterion endorsed by the FDA guidance.

    8. Sample Size for Training Set:

    Not applicable. This is a physical device, not an AI/machine learning model, so there is no concept of a "training set."

    9. How Ground Truth for Training Set Was Established:

    Not applicable, for the same reason as point 8.

    Ask a Question

    Ask a specific question about this device

    K Number
    K240002

    Validate with FDA (Live)

    Date Cleared
    2024-06-14

    (164 days)

    Product Code
    Regulation Number
    884.6160
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    518107 CHINA

    Re: K240002

    Trade/Device Name: G-Vitri™ Vitrification Straw Regulation Number: 21 CFR 884.6160

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The G-Vitri™ Vitrification Straw is a cryopreservation storage device intended for use in vitrification procedures to contain and maintain human oocytes (MII), 4-8 cell embryos, and blastocyst stage embryos.

    Device Description

    Not Found

    AI/ML Overview

    The provided document is an FDA 510(k) clearance letter for the G-Vitri™ Vitrification Straw, a medical device used in assisted reproduction. It does not contain information about acceptance criteria, device performance studies, sample sizes, expert qualifications, or ground truth establishment typically found in a clinical study report or a detailed validation study.

    The letter primarily focuses on:

    • Stating that the device is substantially equivalent to legally marketed predicate devices.
    • Outlining regulatory requirements and general controls for the device.
    • Defining the Indications for Use for the G-Vitri™ Vitrification Straw.

    Therefore, I cannot provide the requested information from the given text. To answer your questions, I would need a different type of document, such as a summary of safety and effectiveness data, a design validation report, or a clinical study report submitted as part of the 510(k) application.

    Ask a Question

    Ask a specific question about this device

    K Number
    K232980

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2024-03-14

    (175 days)

    Product Code
    Regulation Number
    884.6160
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Kingdom

    Re: K232980

    Trade/Device Name: SpermAlign Sperm Separation Device Regulation Number: 21 CFR$ 884.6160
    |
    | Regulation Name: | Assisted reproduction labware |
    | Regulation Number | 21 CFR 884.6160

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The SpermAlign Sperm Separation Device is intended for preparing motile sperm from semen for use in the treatment of infertile couples by intracytoplasmic sperm injection (ICSI) and in vitro fertilization (IVF) procedures.

    Device Description

    SpermAlign is a sperm separation device used to prepare motile sperm for assisted reproductive technology (ART) procedures. Separation is achieved through a fluid filled microstructure which guides the motile sperm to the central collection outlet isolating it from the remaining sample. The device utilizes a total processing volume of 180ul of liquefied semen added in 30ul aliquots to each of the six outer wells and sperm washing media added to the central well. Following incubation for 30 minutes, the concentrated motile sperm is withdrawn from the central well and may be used directly in intracytoplasmic sperm injection (ICSI) or in vitro fertilization (IVF) procedures.

    SpermAlign is sterilized using X-Ray irradiation and has a sterility assurance level (SAL) of 10-6. The devices are individually packaged and for single use only.

    AI/ML Overview

    The provided document is a 510(k) summary for the SpermAlign Sperm Separation Device, indicating substantial equivalence to a predicate device. While it details several non-clinical performance tests, it does NOT contain the specific information requested about the acceptance criteria and study proving device meets acceptance criteria for an AI/ML medical device, particularly regarding test sets, expert adjudication, MRMC studies, or standalone algorithm performance. The device described appears to be a physical labware device, not an AI/ML software device.

    Therefore, I cannot extract the requested information (acceptance criteria, study details for AI/ML performance, sample sizes for AI/ML test/training data, expert qualifications, adjudication methods, MRMC studies, standalone performance, or ground truth establishment relevant to AI/ML) directly from this document.

    However, I can extract information regarding the non-clinical performance studies conducted for this physical device:

    A table of acceptance criteria and the reported device performance (for physical device tests):

    TestAcceptance CriterionReported Performance
    Sterilization ValidationSterility Assurance Level (SAL) of 10⁻⁶Met SAL of 10⁻⁶
    Endotoxin Testing< 20 EU/device< 20 EU/device
    Human Sperm Survival Assay (HSSA)≥80% of the control motility at 24 hours after 30 minutes exposure to SpermAlignMet (before and after accelerated aging to support 12-month shelf life)
    Sperm Separation Performance (Motility)Not explicitly stated as an "acceptance criterion" but reported as performance metricAverage percent of progressively motile sperm: Input 57.4% / Output 91.9%
    Transportation SimulationNot explicitly stated (implied to meet a standard)Performed per ASTM D4169-22
    Package Integrity (after accelerated aging to support 12-month shelf-life)Visual inspection, Bubble leak, Seal strength (implied to meet standards)Performed per ASTM F1886/F1886M, ASTM F2096-11 (2019), ASTM F88/F88M-16. (Results implied to be successful as device was cleared.)

    The document does NOT provide information for the following AI/ML specific questions:

    • Sample sizes used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)
    • Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)
    • Adjudication method (e.g. 2+1, 3+1, none) for the test set
    • If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance
    • If a standalone (i.e. algorithm only without human-in-the-loop performance) was done
    • The type of ground truth used (expert consensus, pathology, outcomes data, etc)
    • The sample size for the training set
    • How the ground truth for the training set was established
    Ask a Question

    Ask a specific question about this device

    K Number
    K233177

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2024-03-08

    (162 days)

    Product Code
    Regulation Number
    884.6160
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Indiana 47404

    Re: K233177 Trade/Device Name: Nest VT Vitrification Device Regulation Number: 21 CFR 884.6160
    Common Name:
    Regulation Number:
    -------------------------------------------
    Regulation Number
    21 CFR 884.6160
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Nest VT Vitrification Device is a cryopreservation storage device intended for use in vitrification procedures to contain and maintain human oocytes (MII), 4-8 cell embryos and blastocyst stage embryos.

    Device Description

    The subject devices, Cook Nest VT Vitrification Devices, are sterile, single-use assisted reproduction storage devices for use in vitrification procedures to contain and maintain oocytes (MII), 4-8 cell embryos, and blastocyst stage embryos. The Cook Nest VT Vitrification Devices are composed of a stick (124.5 mm) and cap (38.5 mm) design with a combined length of 136.5 mm, a 35 mm space for notations, and a 6 mm long loading well. Visible marks are on the distal tip end, on the body of the stick and at the opening of the cap, which are created through laser etching to indicate the location of the tip, the upright orientation of the device and the opening of the cap, respectively. The stick and cap include a taper design that create a seal when assembled. All the subject devices included in this submission are identical except for their color. There are 5 different colors: blue, purple, red, yellow, and green. The subject devices are sterilized using gamma radiation to a sterilization assurance level of 10-9, are one-time use, and have a 2 year shelf-life. During the vitrification procedure, the oocytes or embryos are loaded on the tip of the stick and the stick is capped prior to plunging the device in liquid nitrogen and for subsequent storage.

    AI/ML Overview

    The provided document is a 510(k) summary for the "Nest VT Vitrification Device". It outlines the device's indications for use, comparison to a predicate device, and a summary of non-clinical performance testing. However, it does not contain information on a study proving the device meets acceptance criteria related to AI/algorithm performance, human reader improvement with AI assistance, or the establishment of ground truth by multiple experts.

    The document describes the device as a "cryopreservation storage device intended for use in vitrification procedures to contain and maintain human oocytes (MII), 4-8 cell embryos and blastocyst stage embryos." The performance testing discussed (sterilization, endotoxin, cooling/warming rates, MEA testing, package integrity, mechanical performance) are related to the physical and biological compatibility of the device itself, not to an AI or diagnostic algorithm's performance.

    Therefore, I cannot fulfill your request as the provided text does not describe a study involving an AI or algorithm, nor does it detail acceptance criteria and performance data for such a system. The questions you posed (e.g., sample size for test set, number of experts for ground truth, MRMC study, standalone performance) are relevant to the evaluation of AI/ML-based medical devices, which this document does not concern.

    Ask a Question

    Ask a specific question about this device

    K Number
    K221810

    Validate with FDA (Live)

    Date Cleared
    2022-10-31

    (131 days)

    Product Code
    Regulation Number
    884.6160
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    LensHooke CA0 Sperm Separation Device LensHooke CA1 Sperm Separation Device Regulation Number: 21 CFR§ 884.6160
    Assisted Reproduction Labware |
    | Regulation Number: | 884.6160

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The LensHooke CA0 Sperm Separation Device and the LensHooke CA1 Sperm Separation Device are intended for preparing motile sperm from semen for use in the treatment of infertile couples by intracytoplasmic sperm injection (ICSI), in vitro fertilization (IVF) and intrauterine insemination (IUI) procedures.

    Device Description

    The LensHooke CA0 Sperm Separation Device and LensHooke CA1 Sperm Separation Device are used to prepare motile sperm from semen based on the mobility of motile sperm. The LensHooke Sperm Separation Device has a base and filter layers to separate and process the semen sample. The LensHooke Sperm Separation Device has two models, CA0 with one filter layer and CA1 with two filter layers. Liquefied semen (1 mL) is added to the base and sperm washing medium is added to the filter via a filter port. After incubation, the separated sperm are collected from the filter layer via the filter port. The subject devices are radiation-sterilized with a sterility assurance level (SAL) of 10 °. The LensHooke Sperm Separation Devices are individually packaged and for single-use only.

    AI/ML Overview

    The device in question is the LensHooke CA0 Sperm Separation Device and the LensHooke CA1 Sperm Separation Device.

    Here's a breakdown of the acceptance criteria and supporting study details:

    1. Table of Acceptance Criteria and Reported Device Performance:

    Acceptance CriteriaReported Device Performance
    Human Sperm Survival Assay (HSSA): ≥80% of the control motility at 24 hours after exposure for 30 minutes.The HSSA was performed before and after accelerated aging to support a 2-year shelf life. The rate of motile sperm after incubation was compared to that of a control (no exposure to the subject device). The device met this criterion.
    Endotoxin: ≤20 EU/deviceThe device demonstrated levels of endotoxin below or equal to 20 EU/device, as confirmed by USP<85> and ANSI/AAMI ST72:2019 testing.
    Sterility: 10⁻⁶ SAL (Sterility Assurance Level)The device underwent Sterilization Validation Study per ISO 11137-1:2006, confirming a sterility assurance level of 10⁻⁶.
    Package Integrity (Seal Strength): Met requirements of ASTM F88/F88M-15Package integrity testing following accelerated aging per ASTM F1980-21 included Seal strength testing Per ASTM F88/F88M-15. The device met this criterion.
    Package Integrity (Dye Penetration): Met requirements of ASTM F1929-15Package integrity testing following accelerated aging per ASTM F1980-21 included Dye penetration testing per ASTM F1929-15. The device met this criterion.
    Transportation Simulation: Met requirements of ISTA 3A (2018)A Transportation Simulation Study per ISTA 3A (2018) was conducted to ensure the device's integrity during transport. The device met this criterion.
    Sperm Separation Performance (Motility Improvement): Improvement in percentage of motile sperm and progressively motile sperm in output samples compared to input samples.CA0 device: Average improvement in total motility of 24.4% and an average improvement in progressive motility of 26.6%. CA1 device: Average improvement in total motility of 25.9% and an average improvement in progressive motility of 27.1%. Note: Specific quantitative acceptance criteria for motility improvement were not explicitly stated in the provided text, but the reported improvements demonstrate effective performance.
    Shelf-Life: 24 monthsSupported by package integrity and HSSA testing after accelerated aging.

    2. Sample Size Used for the Test Set and Data Provenance:

    The document does not explicitly state the numerical sample size for the "test set" in terms of number of donor semen samples used for the Human Sperm Survival Assay (HSSA) or the Sperm Separation Performance study. It mentions using "donor sperm" and "donor semen samples" without specifying the quantity.

    • Data Provenance: The document does not specify the country of origin of the data or whether the studies were retrospective or prospective.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts:

    This information is not provided in the document. The studies described are primarily benchtop or laboratory performance tests, not clinical studies involving expert interpretation of results to establish ground truth in the context of diagnostic accuracy.

    4. Adjudication Method for the Test Set:

    This information is not applicable as the studies are technical performance tests and not clinical studies requiring expert adjudication of case interpretations.

    5. If a Multi Reader Multi Case (MRMC) Comparative Effectiveness Study was done:

    No, an MRMC comparative effectiveness study was not done. The studies described are focused on the device's technical performance in isolating motile sperm and maintaining sperm viability, not on comparing reader effectiveness with and without AI assistance.

    6. If a Standalone (i.e. algorithm only without human-in-the-loop performance) was done:

    Yes, the studies described are standalone performance evaluations of the device (LensHooke CA0/CA1 Sperm Separation Device) without human-in-the-loop performance considerations. The device is a physical product designed for sperm separation, not an AI algorithm.

    7. The Type of Ground Truth Used:

    The ground truth for the performance studies was established through:

    • Laboratory measurements and assays: For HSSA, this involves measuring sperm motility percentage using established laboratory methods. For endotoxin, it's quantitative measurement against a standard. For sterility, it's confirmation of a specific SAL.
    • Comparison to control samples: In the HSSA, the motility of sperm exposed to the device was compared to that of a control group (sperm not exposed to the device).
    • Direct measurement of output characteristics: For sperm separation performance, the percentage of motile and progressively motile sperm in the output samples was directly measured and compared to the input samples.
    • Industry standards and specifications: For physical tests like package integrity and transportation simulation, the ground truth is adherence to the specified ASTM and ISTA standards.

    8. The Sample Size for the Training Set:

    This information is not applicable. The LensHooke CA0/CA1 Sperm Separation Device is a physical medical device, not an AI/machine learning algorithm that requires a "training set" of data.

    9. How the Ground Truth for the Training Set Was Established:

    This information is not applicable as the device is not an AI/machine learning algorithm requiring a training set.

    Ask a Question

    Ask a specific question about this device

    K Number
    K213869

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2022-03-11

    (88 days)

    Product Code
    Regulation Number
    884.6160
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Viby J, 8260 Denmark

    K213869 Re: Trade/Device Name: EmbryoSlide+ ic8 dish Regulation Number: 21 CFR§ 884.6160
    Common Name
    Regulation Number
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The EmbryoSlide+ ic8 dish is intended for culturing, handling and preparation for transfer of human embryos. The EmbryoSlide+ ic8 dish must be used together with the EmbryoScope+ incubator.

    Device Description

    The EmbryoSlide+ ic8 dish is single use, sterile for embryo culture, handling, and preparation for transfer during assisted reproduction technology procedures. The EmbryoSlide+ ic8 dish is equipped with barcode label area for unique identification of the culture dish, and a small area which can be used for manual writing. The EmbryoSlide+ ic8 dish has eight culture wells. Each well holds a single embryo in 20µL of culture medium. In addition, four rinsing wells are available, each rinsing well holding 25-30μL medium. The culture area of the dish, comprising both the culture wells, must be covered with 1.6mL culture oil overlay to minimize osmolarity changes during culture in a dry environment.

    AI/ML Overview

    I am sorry but this document does not contain information about the acceptance criteria and the study that proves the device meets the acceptance criteria. This document is an FDA 510(k) premarket notification for a medical device (EmbryoSlide+ ic8 dish) and primarily focuses on demonstrating substantial equivalence to a legally marketed predicate device.

    While it mentions some specifications and testing performed (e.g., sterility, endotoxin testing, mouse embryo assay), it does not detail a formal study designed to prove the device meets specific acceptance criteria in the way you've outlined. The information provided is for regulatory clearance based on substantial equivalence, not a detailed clinical or comparative effectiveness study report.

    Therefore, I cannot provide the requested table and detailed study information based on this document.

    Ask a Question

    Ask a specific question about this device

    K Number
    K203626

    Validate with FDA (Live)

    Date Cleared
    2021-06-04

    (175 days)

    Product Code
    Regulation Number
    884.6160
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Device Name: SureStrip Vitrification Straw, SureLock Vitrification Straw Regulation Number: 21 CFR§ 884.6160

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The SureStrip Virification Straw is cryopreservation storage device. It is intended for use in vitrification procedures to contain and maintain human oocytes (MII), 4-8 cell stage embryos, or blastocyst stage embryos.

    The SureLock Vitrification Straw is a cryopreservation storage device. It is intended for use in vitrification procedures to contain and maintain human oocytes (MII) or 1-cell stage embryos.

    Device Description

    Not Found

    AI/ML Overview

    The provided text includes a 510(k) clearance letter for the SureStrip Vitrification Straw and SureLock Vitrification Straw. However, this document does not contain information regarding acceptance criteria or a study proving the device meets said criteria.

    The document states that the devices are substantially equivalent to legally marketed predicate devices, which means they do not require new performance studies to demonstrate safety and effectiveness for a 510(k) clearance.

    Therefore, I cannot provide the requested information from the given text.

    The information I would have looked for, but is absent, includes:

    1. A table of acceptance criteria and reported device performance.
    2. Sample size and data provenance for a test set.
    3. Details on experts used for ground truth.
    4. Adjudication method.
    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done.
    6. If standalone performance was evaluated.
    7. Type of ground truth used.
    8. Sample size and ground truth establishment for a training set.
    Ask a Question

    Ask a specific question about this device

    Page 1 of 5