Search Filters

Search Results

Found 192 results

510(k) Data Aggregation

    K Number
    K252583

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2026-03-12

    (209 days)

    Product Code
    Regulation Number
    884.5160
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    electric breast pump (PA221); Moon Wave electric breast pump (PA220)
    Regulation Number: 21 CFR 884.5160
    Model Number:** PA220, PA221
    Common Name: Powered Breast Pump
    Regulation Number: 21 CFR 884.5160
    | A Cute Baby, Inc. | Acute Ideas Co., Ltd. | Acute Ideas Co., Ltd. |
    | Regulation Number | 21 CFR 884.5160
    | 21 CFR 884.5160 | 21 CFR 884.5160 |
    | Regulation Name | Powered Breast Pump | Powered Breast Pump

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Moon Wave (PA220) and Mini Moon (PA221) Electric Breast Pump is a personal use, electrically powered device used to express milk from the breasts of lactating women. This device is not intended for hospital use.

    Device Description

    PA220 – Moon Wave Electric Breast Pump: The PA220 is a countertop-style, electrically powered breast pump intended for single-user home use. The device incorporates dual-phase pumping (Stimulation and Expression modes), adjustable suction levels, and adjustable cycle speeds. It features a numeric LED display, programmable timer, night light, and an integrated silicone diaphragm backflow protection system. The PA220 is powered by a 12 V DC adapter or an integrated 7.4 V lithium-ion rechargeable battery pack (2S1P configuration).

    PA221 – Mini Moon Electric Breast Pump: The PA221 is a compact, wearable, electrically powered breast pump with a Slim-Cup hands-free collection system. The device incorporates dual-phase pumping (Stimulation and Expression modes) with adjustable suction levels and preset cycle speeds. It features LED suction level indicators and an integrated silicone diaphragm backflow protection system. The PA221 is powered by a USB-C 5 V adapter or an integrated 3.7 V lithium-ion rechargeable battery pack (1S1P configuration).

    Materials: The breast- and milk-contacting components of the device (e.g., flange, breast shield body, funnel base, collection bottle, cup, and diaphragm) are manufactured from polypropylene and silicone materials.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K253934

    Validate with FDA (Live)

    Date Cleared
    2026-03-09

    (90 days)

    Product Code
    Regulation Number
    884.5160
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Breast Pump (BP380, BP380-A, BP380-B, BP380-C, M5, M5-A, M5-B, M5-C)
    Regulation Number: 21 CFR 884.5160
    Breast Pump (BP380, BP380-A, BP380-B, BP380-C, M5, M5-A, M5-B, M5-C)
    Regulation Number: 21 CFR 884.5160
    Powered breast pump |
    | Regulation Name | Powered Breast Pump |
    | Regulation Number | 21 CFR 884.5160
    Subject Device** | Predicate Device | Conclusion |
    |---|---|---|---|
    | Regulation No. | 884.5160
    | 884.5160 | Same |
    | Product Code | HGX | HGX | Same |
    | Classification | Class II | Class

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Momcozy Wearable Breast Pump (Model: BP380,BP380-A,BP380-B,BP380-C,M5,M5-A,M5-B,M5-C) is a powered breast pump intended to express milk from lactating women in order to collect milk from their breasts. The device is intended for a single user.

    Device Description

    The Momcozy Wearable Breast Pump is an electrically powered wearable breast pump. There are two product series: Momcozy Wearable Breast Pump M5 series (M5,M5-A,M5-B,M5-C) and Momcozy Wearable Breast Pump BP380 series (BP380,BP380-A,BP380-B,BP380-C).

    The differences between M5 series and BP380 series are as follows:

    1. BP380 series is equipped with Bluetooth functionality, and can be wirelessly operated via Bluetooth connection to a mobile device
    2. M5 series disables the Bluetooth functionality.

    The differences between each model in a series is the color of the main unit.

    The device is intended to be used by lactating women to express and collect milk from their breast. The device is not sterile. The breast pump stimulates lactation and extracts milk from the breasts by creating a seal around the nipple and applying and releasing suction to the breast. The milk is collected in a milk collector. The device includes stimulation mode, expression mode, and mixed mode. In stimulation mode, the breast pump begins with a quick and short sucking pattern to get your milk to start flowing. In expression mode, the breast pump begins with a slow and long sucking pattern for milk expression, sucking more deeply and more slowly. In mixed mode, the breast pump begins with a quick and short sucking pattern, followed by a slow and long sucking pattern. The device uses a diaphragm-type vacuum pump driven by a microprocessor. The microprocessor provides control over vacuum pressure and cycle speed. The pump remembers the mode and suction level settings. When restarted, it will resume with the same mode and suction level as when it was last turned off. Each mode's suction level setting is also remembered individually and remains consistent during future use.

    The device can be operated in single/double pumping modes. To prevent milk from flowing into the vacuum system, the milk collection set includes a diaphragm that physically separates the milk-contacting pathway from the vacuum system. The motor unit operates on a rechargeable battery. The rechargeable battery can be charged from the external power adapter (not included in this device) through the provided charging cable. The user interface consists of buttons and LED display in which the user switches between modes and controls the vacuum pressure. The BP380 series(BP380,BP380-A,BP380-B,BP380-C) can be wirelessly operated via Bluetooth connection to a mobile device. By using app , users can either select one of three preset operating modes. Available modes include Stimulation, Expression and Mixed.

    The devices includes a milk collection set that consists of the following: double-sealed flange, flange insert, diaphragm assembly, duckbill valve assembly, milk collector and main unit pump motor. Each component can be purchased separately by the user if needed. The materials of the milk collection set comply with U.S. food-contact safety testing requirements.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K252422

    Validate with FDA (Live)

    Date Cleared
    2026-02-13

    (196 days)

    Product Code
    Regulation Number
    884.5160
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    CHINA

    Re: K252422
    Trade/Device Name: Wearable Breast Pump (Model W2)
    Regulation Number: 21 CFR 884.5160
    Wearable Breast Pump (Model W2)
    Common Name: Powered Breast Pump
    Regulation Number: 21 CFR 884.5160
    Wearable Breast Pump (Model W8) | N/A |
    | Product Code | HGX | HGX | Same |
    | Regulation Number | 21 CFR 884.5160
    | 21 CFR 884.5160 | Same |
    | Regulatory Class | Class II | Class II | Same |
    | Patient Population |

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Wearable Breast Pump (Model W2) is a powered breast pump intended to be used by lactating women to express and collect milk from their breasts. It is intended for a single user.

    Device Description

    The Wearable Breast Pump (Model W2) is a powered breast pump intended to be used by lactating women to express and collect milk from their breasts; it is intended for a single user. The Wearable Breast Pump (Model W2) is a breast pump powered by lithium battery, utilizing an embedded control program to manage all device functions. The main components of these pumps include: pump, valve, control board, and milk collector. The user interface allows the user to switch from expression and massage modes and control the vacuum levels within those modes. The Wearable Breast Pump (Model W2) also includes a 'Hot Compress' mode not associated with any vacuum pressure or cycle speed. When enabled, the flange is heated, the symbol indicating heating will light up, and the maximum temperature is ≤ 42°C.

    All available modes consist of 9 vacuum levels. The Wearable Breast Pump (Model W2) is capable of providing vacuum levels from 40-120 mmHg with cycling rates from 107-143 cycles per minute in massage mode and vacuum levels from 120-245 mmHg with cycling rates from 34-111 cycles per minute in expression mode. The Wearable Breast Pump (Model W2) is charged with a 5 V DC adaptor and powered by an internal rechargeable lithium-ion polymer battery. The motor unit operates on embedded software. Software updates by end-users are not supported. The subject device is for repeated use by a single user in a home environment. The device is provided non-sterile.

    The motor unit operates on a rechargeable battery and does not function when charging. The rechargeable battery can be charged from the external USB adapter if the motor unit is not in operation.

    The breast pump expresses milk by creating a seal around the nipple using the flange and applying and releasing suction to the nipple. The milk is collected in a milk collection container, which can be used for storage. To prevent milk from flowing into the vacuum system, a backflow protection membrane physically separates the milk-contacting pathway from the vacuum system.

    All other components (i.e., motor unit/housing) of the subject device is not in contact with the breast. All milk contacting components are compliant with 21 CFR 177.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K252420

    Validate with FDA (Live)

    Date Cleared
    2026-02-13

    (196 days)

    Product Code
    Regulation Number
    884.5160
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Re: K252420
    Trade/Device Name: Wearable Breast Pump (Model W12)
    Regulation Number: 21 CFR 884.5160
    Wearable Breast Pump (Model W12)
    Common Name: Powered Breast Pump
    Regulation Number: 21 CFR 884.5160
    Wearable Breast Pump (Model W8) | N/A |
    | Product Code | HGX | HGX | Same |
    | Regulation Number | 21 CFR 884.5160
    | 21 CFR 884.5160 | Same |
    | Regulatory Class | Class II | Class II | Same |
    | Patient Population |

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Wearable Breast Pump (Model W12) is a powered breast pump intended to be used by lactating women to express and collect milk from their breasts. It is intended for a single user.

    Device Description

    The Wearable Breast Pump (Model W12) is a powered breast pump intended to be used by lactating women to express and collect milk from their breasts; it is intended for a single user. The Wearable Breast Pump (Model W12) is a breast pump powered by lithium battery, utilizing an embedded control program to manage all device functions. The main components of these pumps include: pump, valve, control board, and milk collector. The user interface allows the user to switch from stimulation, expression, auto, and massage modes and control the vacuum levels within those modes. The Wearable Breast Pump (Model W12) also includes a 'Hot Compress' mode not associated with any vacuum pressure or cycle speed. When enabled, the flange is heated, the symbol indicating heating will light up, and the maximum temperature is <= 42 degrees C.

    All available modes consist of 12 vacuum levels. The Wearable Breast Pump (Model W12) is capable of providing vacuum levels from 40-150 mmHg with cycling rates from 86-127 cycles per minute in stimulation mode, vacuum levels from 120-245 mmHg with cycling rates from 34-109 cycles per minute in expression mode, vacuum levels from 40-245 mmHg with cycling rates from 34-130 cycles per minute in auto mode, and vacuum levels from 40-120 mmHg with cycling rates from 90-143 cycles per minute in massage mode. The Wearable Breast Pump (Model W12) is charged with a 5 V DC adaptor and powered by an internal rechargeable lithium-ion polymer battery. The motor unit operates on embedded software. Software updates by end-users are not supported. The subject device is for repeated use by a single user in a home environment. The device is provided non-sterile.

    The motor unit operates on a rechargeable battery and does not function when charging. The rechargeable battery can be charged from the external USB adapter if the motor unit is not in operation.

    The breast pump expresses milk by creating a seal around the nipple using the flange and applying and releasing suction to the nipple. The milk is collected in a milk collection container, which can be used for storage. To prevent milk from flowing into the vacuum system, a backflow protection membrane physically separates the milk-contacting pathway from the vacuum system.

    All other components (i.e., motor unit/housing) of the subject device is not in contact with the breast. All milk contacting components are compliant with 21 CFR 177.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K253149

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2026-02-13

    (141 days)

    Product Code
    Regulation Number
    884.5160
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    K253149**
    Trade/Device Name: Motion InBra (YM-8801) wearable breast pump
    Regulation Number: 21 CFR 884.5160
    YM-8801) wearable breast pump
    Common Name: Powered breast pump
    Regulation Number: 21 CFR 884.5160
    Device | Comparison |
    |---|---|---|---|
    | Product Code | HGX | HGX | Same |
    | Regulation Number | 21 CFR 884.5160
    | 21 CFR 884.5160 | Same |
    | Regulatory Class | Class II | Class II | Same |
    | Patient Population |

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Motion InBra (YM-8801) wearable breast pump is a powered breast pump to be used by lactating women to express and collect milk from their breasts. The Motion InBra (YM-8801) powered breast pump is intended for a single user. This breast pump is intended to be used in a home environment.

    Device Description

    The Motion InBra (YM-8801) wearable breast pump is a powered breast pump intended to be used by lactating women to express and collect milk from their breasts; it is intended for a single user. The Motion InBra (YM-8801) is a breast pump powered by lithium-ion battery, utilizing an embedded control program to manage all device functions. The user interface allows the user to switch from stimulation and expression modes and control the vacuum levels within those modes.

    All available modes consist of 9 vacuum levels. The Motion InBra (YM-8801) is capable of providing vacuum levels from 80-160 mmHg with cycling rates from 100-120 cycles per minute in stimulation mode and vacuum levels from 80-280 mmHg with cycling rates from 35-75 cycles per minute in expression mode. The device is charged with a 5 V DC adaptor and powered by an internal rechargeable lithium-ion polymer battery. The motor unit operates on embedded software. Software updates by end-users are not supported. The subject device is for repeated use by a single user in a home environment. The device is provided non-sterile.

    The motor unit operates on a rechargeable battery and does not function when charging. The rechargeable battery can be charged from the external USB adaptor if the motor unit is not in operation.

    The Motion InBra Wearable Breast Pump includes 2-Phase Expression Technology: Stimulation and Expression Phases. The Stimulation Phase initiates with a rapid suction pattern designed to trigger the milk ejection reflex and promote milk flow. In contrast, the Expression Phase begins with a slower and deeper suction rhythm, optimized for effective milk extraction once let-down has occurred. The milk is collected in a milk collection container, which can be used for storage. To prevent milk from flowing into the vacuum system, a backflow protection membrane physically separates the milk-contacting pathway from the vacuum system.

    The operating life of the Motion InBra Wearable Breast Pump is 150 hours. The expected operating life of the washable parts (milk container, breast shield, insert and membrane) is 3 months.

    All other components (i.e., motor unit/housing) of the subject device are not in contact with the breast. All milk contacting components are compliant with 21 CFR 175 and 21 CFR 177.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K251423

    Validate with FDA (Live)

    Date Cleared
    2026-02-06

    (274 days)

    Product Code
    Regulation Number
    884.5160
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    SOUTH

    Re: K251423
    Trade/Device Name: Spectra S1 Pro; Spectra S2 Pro
    Regulation Number: 21 CFR 884.5160
    Spectra S1 Pro; Spectra S2 Pro
    Common Name: Powered Breast Pump
    Regulation Number: 21 CFR 884.5160

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Spectra S1 Pro and Spectra S2 Pro are single-user, powered breast pumps intended to express and collect milk from the breasts of lactating women.

    Device Description

    The Spectra S1 Pro and Spectra S2 Pro are single-user, powered breast pumps intended to express and collect milk from the breasts of lactating women. Pumping can be performed on one breast (single pumping) or both breasts (double pumping) at the same time. The Spectra S1 Pro and Spectra S2 Pro are comprised of the following components: pump unit, adapter, wide breast shield, back-flow protector, tubing, silicone valve, bottle cap, bottle screw, nipple, airtight cap, and PP bottle. The device is provided non-sterile.

    The Spectra S1 Pro and Spectra S2 Pro support a single pumping mode in which only one breast is expressed and a dual pumping mode in which both breasts are expressed. The user can switch between Massage Mode and Expression Mode using designated buttons and adjust the vacuum level and cycle speed within each mode.

    Spectra S1 Pro and Spectra S2 Pro includes the following features:

    • Expression can be performed on one breast only (single mode), on both sides simultaneously (dual mode).
    • Expression mode: 1-15 level (50-270 mmHg), cycle speeds (38, 42, 46, 50, 52, 58)
    • Massage mode: 1-5 level (50-180 mmHg), cycle speeds (70, 80, 90, 100, 105)

    The Spectra S1 Pro operates using an AC adapter (100-240V AC, 50/60Hz, DC 12V) or a rechargeable Li-Polymer battery (11.1V, 2000mAh). The Spectra S2 Pro operates using an AC adapter (100-240V AC, 50/60Hz, DC 12V) only.

    When the backflow protector is assembled between the pump unit and the breast shield, the silicone membrane inside the backflow protector creates a physical barrier by preventing air and milk from flowing back into the pump unit.

    All milk contacting components are compliant with 21 CFR 177.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K253498

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2026-01-22

    (85 days)

    Product Code
    Regulation Number
    884.5160
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Illinois 60050

    Re: K253498
    Trade/Device Name: Pump In Style® Pro+
    Regulation Number: 21 CFR 884.5160
    name:** Powered breast pump
    Regulation name: Powered Breast Pump
    Regulation number: 21 CFR 884.5160

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Pump In Style® Pro+ breast pump is a powered breast pump to be used by lactating women to express and collect milk from their breasts. The powered breast pump is intended for a single user. This breast pump is intended to be used in a home environment.

    Device Description

    Pump In Style Pro+ is a powered breast pump intended to be used in a home environment (or similar such as an office). It features 2-Phase Expression technology, which runs pumping in two phases (Stimulation and Expression) by applying a cyclic negative pressure to mimic a baby's natural nursing rhythm.
    Pump In Style Pro+ comprises a pump unit, which includes:

    • User-adjustable controls: "On/Off" for powering on/off the device, "Let-down" for switching between pumping phases, and "Increase vacuum"/ "Decrease vacuum" for controlling vacuum intensity levels;
    • a port for connection of the tubing that channels the vacuum;
    • a port for connection of the power supply;
    • an internal, non-replaceable, rechargeable lithium-ion battery providing users the option to power the breast pump without reliance on a wall-connection or external power source;
    • a LED battery status indicator which informs users of available charge;
    • a pump phase LED status indicator which informs users of the active pump phase;
    • vacuum level LED indicators (total of 16, one for each vacuum level).
      Pump In Style Pro+ is a double electric breast pump that can be used to extract breast milk from one breast at a time (i.e., single pumping) or from both breasts simultaneously (i.e., double pumping). A DC (direct current) motor is used to drive a membrane aggregate. This membrane aggregate creates the negative pressure (suction) required to extract the breast milk.
      The materials of the milk-contacting components are compliant with 21 CFR 177 and 21 CFR 178.
    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K253072

    Validate with FDA (Live)

    Date Cleared
    2025-12-23

    (91 days)

    Product Code
    Regulation Number
    884.5160
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    P23, P24, P25, P26, P27, P28, P29, P30, P20-A, P20-B, P20-C, P20-D)
    Regulation Number: 21 CFR 884.5160
    P20-C, P20-D) |
    |---|---|
    | Common Name | Powered Breast Pump |
    | Regulation Number | 21 CFR 884.5160
    P20-C, P20-D | LD-208L | |
    | Product Code | HGX | HGX | Same |
    | Regulation Number | 21 CFR 884.5160
    | 21 CFR 884.5160 | Same |
    | Regulatory Class | Class II | Class II | Same |
    | **Patient Population

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Paruu Wearable Breast Pump is a powered breast pump intended to express milk from lactating women in order to collect milk from their breasts. The device is intended for a single user.

    Device Description

    The Paruu Wearable Breast Pump is a powered breast pump intended to be used by lactating women to express and collect milk from their breast in home healthcare environment. The breast pump stimulates lactation and extracts milk from the breasts by creating a seal around the nipple and applying and releasing suction to the breast. The breast milk is collected in a milk collector. The device consists of a pump motor (main unit), milk collection set (flange, diaphragm, duckbill valve, milk collector, flange cover) and accessories (flange insert, charging cable). The milk collection set and flange insert can be purchased separately.

    The device uses a diaphragm-type vacuum pump driven by a microprocessor. The microprocessor provides control over vacuum pressure and cycle speed. The user interface consists of buttons allowing the user to switch between modes and control the vacuum pressure levels, and LED display that providing information on current mode, level, timer and battery status.

    The device includes 23 different models, and based on their technological characteristics, are divided into two broad categories – P16 series consisting of models P16, P16-A, P16-B, P16-C, P16-D, and P20 series consisting of models P20, P9, P10, P10 PRO, P21, P22, P23, P24, P25, P26, P27, P28, P29, P30, P20-A, P20-B, P20-C, P20-D. The models within each series vary in terms of their external color. All device models include 4 working modes (Stimulation, Expression, Two-in-one and Dual frequency for P16 Series and Stimulation, Expression, Lactation, and Traction for P20 Series) and 12 suction levels for each mode.

    To prevent milk from flowing into the vacuum system, the milk collection set includes a diaphragm that physically separates the milk-contacting pathway from the vacuum system. The motor unit operates on 3.7V rechargeable lithium battery. The rechargeable battery can be charged from the external power adapter (not included with the device) through the provided charging cable. All milk contacting components of the device are compliant with 21 CFR 177.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K252754

    Validate with FDA (Live)

    Date Cleared
    2025-12-19

    (112 days)

    Product Code
    Regulation Number
    884.5160
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    K252754**
    Trade/Device Name: Wearable Electric Breast Pump (YM-8803)
    Regulation Number: 21 CFR 884.5160
    Pump (Models: S9 Pro, S12 Pro) | Electric Breast Pump (Models 918, HF918) |
    | Regulation No. | CFR 884.5160
    | CFR 884.5160 | CFR 884.5160 |
    | Product Code | HGX | HGX | HGX |
    | Classification | Class ll | Class
    Pump (Models: S9 Pro, S12 Pro) | Electric Breast Pump (Models 918, HF918) |
    | Regulation No. | CFR 884.5160
    | CFR 884.5160 | CFR 884.5160 |
    | Product Code | HGX | HGX | HGX |
    | Classification | Class ll | Class

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Wearable electric breast pump (Model: YM-8803) is a powered breast pump intended to express milk from lactating women in order to collect milk from their breasts. The device is intended for a single user.

    Device Description

    The Wearable electric breast pump (Model YM-8803) is a powered breast pump intended to express milk from lactating women in order to collect milk from their breasts. The device is intended for a single user. The device is provided not sterile and should be cleaned and disinfected according to the instructions for use.

    The breast pump stimulates lactation and extracts milk from the breasts by creating a seal around the nipple and applying and releasing suction to the breast. The milk is collected in a milk container.

    The device uses a diaphragm-type vacuum pump driven by a microprocessor. The microprocessor provides control over vacuum pressure and cycle speed.

    To prevent milk from flowing into the vacuum system, the milk collection set includes a diaphragm that physically separates the milk-contacting pathway from the vacuum system. The motor unit operates on a rechargeable battery. The rechargeable battery can be charged from the external power adaptor specified in IFU (not included) through the provided USB charging cable. The user interface features four buttons and an LED display, allowing the user to navigate between modes and adjust the vacuum pressure.

    The subject device has two modes: Stimulation and Expression.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K252342

    Validate with FDA (Live)

    Date Cleared
    2025-12-19

    (144 days)

    Product Code
    Regulation Number
    884.5160
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    /Device Name: Electric Breast Pump (YM-8807, YM-8805, YM-8806, YM-8810)
    Regulation Number: 21 CFR 884.5160
    , YM-8805, YM-8806, YM-8810)
    Common name: Powered Breast Pump
    Regulation Number: 21 CFR 884.5160
    Pump (Models 918, HF918) | Comparison |
    |------|------|------|------|
    | Regulation | Class II, 21 CFR 884.5160
    | Class II, 21 CFR 884.5160 | Same |
    | Product Code | HGX | HGX | Same |
    | Indications for Use | The

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Electric Breast Pump (Model YM-8807, YM-8805, YM-8806 and YM-8810) is a powered breast pump intended to express milk from lactating women in order to collect milk from their breasts. The device is intended for a single user.

    Device Description

    The Electric Breast Pump (Models YM-8807, YM-8805, YM-8806 and YM-8810) is a powered breast pump intended to express milk from lactating women in order to collect milk from their breasts. The device is provided non-sterile and is reusable device intended for a single user in home healthcare environment.

    The breast pump stimulates lactation and extracts milk from the breasts by creating a seal around the nipple and applying and releasing suction to the breast. The milk is collected in a milk collector. The device uses a diaphragm-type vacuum pump driven by a microprocessor. The microprocessor provides control over vacuum pressure and cycle speed. The motor unit operates on a rechargeable Lithium battery (3.7V/1400mAh). The rechargeable battery can be charged from the external power adaptor specified in the User Manual (not included) through the provided USB charging cable. The user interface features four buttons (power, mode selection, vacuum level increase and decrease) and an LED display (current mode, level, timer and battery status), allowing the user to navigate between modes and adjust the vacuum pressure.

    The subject device includes four models that have same working principle and technology but differ in terms of their appearance, components, and materials. All device models have three modes of operation: Stimulation phase, Expression phase, Simulated sucking Phase, with nine levels in each mode. The Stimulation phase provides high cycle frequency and gentle suction, while the Expression phase provided slower cycles with higher vacuum pressures. The Simulated sucking phase provides a combination of the other two phases - two cycles in Expression phase followed by one Stimulation phase cycle, then three Expressions phase cycles followed by two in Stimulation phase to form one cycle.

    To prevent milk from flowing into the vacuum system, the milk collection set includes a diaphragm that physically separates the milk-contacting pathway from the vacuum system. All milk contacting components of the device are compliant with 21 CFR 177.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    Page 1 of 20