Search Results
Found 40 results
510(k) Data Aggregation
(109 days)
**
Trade/Device Name: Permatage Flowable, Settable Bone Paste
Regulation Number: 21 CFR 882.5300
Methacrylate for Cranioplasty
Classification: Class II
Product codes: GXP
Regulation: 21 CFR 882.5300
Orthocon Permatage Flowable, Settable Bone Paste is a self-setting cement indicated for use in the repair of neurosurgical burr holes, contiguous craniotomy cuts and other cranial defects. Permatage Flowable, Settable Bone Paste should be used only in skeletally mature individuals.
Permatage Flowable, Settable Bone Paste is a sterile, biocompatible, nonabsorbable material of Paste-like consistency for use in repair of cranial defects. The single use Permatage device contains two separate components of paste-like consistency comprised of granular calcium phosphate, paraffin oil, vitamin E acetate, a triglyceride, and a mixture of nonabsorbable, polyether-based polymers. When mixed together, the components of the Permatage device form a nonabsorbable cohesive, paste-like material that adheres to the bone surface and remains in place following application. The resulting hardening material is primarily calcium phosphate and nonabsorbable polymer materials. Permatage components must be mixed immediately prior to use.
N/A
Ask a specific question about this device
(30 days)
Connecticut 06902
Re: K253854
Trade/Device Name: MONTAGE XT Cranial Cement
Regulation Number: 21 CFR 882.5300
Phosphate Cranial Cement
Classification: Class II
Product codes: GXP
Regulation: 21 CFR 882.5300
MONTAGE XT Cranial Cement is a self-setting calcium phosphate cement indicated for use in the repair of neurosurgical burr holes, contiguous craniotomy cuts, and other cranial defects with a surface area no larger than 25 cm². MONTAGE XT Cranial Cement should be used only in skeletally mature individuals.
MONTAGE XT Cranial Cement is a sterile, biocompatible, resorbable material for use in repair of cranial defects. The MONTAGE XT Cranial Cement comprises of two separate components of putty consistency containing granular calcium phosphate, calcium stearate, vitamin E acetate, a triglyceride, a polyalcohol and a mixture of lactide-diester and polyester-based polymers. When mixed together, the components of the MONTAGE XT Cranial Cement form a putty-like material. The resulting hardened, resorbable material is primarily calcium phosphate and is slowly resorbed during the remodeling process. Montage XT components must be mixed immediately prior to use.
N/A
Ask a specific question about this device
(164 days)
Connecticut 06902
Re: K241027
Trade/Device Name: Permatage Settable Bone Putty Regulation Number: 21 CFR 882.5300
|
| Product codes: | GXP |
| Regulation: | 21 CFR 882.5300
Orthocon Permatage Settable Bone Putty is a self-setting cement indicated for use in the repair of neurosurgical burr holes, contiguous craniotomy cuts and other cranial defects. Permatage Settable Bone Putty should be used only in skeletally mature individuals.
Permatage Settable Bone Putty is a sterile, biocompatible, nonabsorbable material of putty-like consistency for use in repair of cranial defects. The single use Permatage device contains two separate components of putty-like consistency comprised of granular calcium phosphate, paraffin oil, vitamin E acetate, a triglyceride, and a mixture of nonabsorbable, polyether-based polymers. When mixed together, the components of the Permatage device form a nonabsorbable cohesive, putty-like material that adheres to the bone surface and remains in place following application. The resulting hardening material is primarily calcium phosphate and nonabsorbable polymer materials. Permatage components must be mixed immediately prior to use.
The provided text is a 510(k) summary for the Orthocon Permatage Settable Bone Putty, a medical device. This type of submission focuses on demonstrating substantial equivalence to a legally marketed predicate device, rather than proving that the device meets specific acceptance criteria through a traditional clinical study with performance metrics like sensitivity or specificity.
Therefore, the requested information regarding acceptance criteria, device performance, sample sizes for test/training sets, expert involvement, and ground truth establishment for an AI/algorithm-based device is not applicable to this document. The document describes a traditional medical device (bone putty) and its regulatory clearance process, which relies on biocompatibility testing, bench testing, and in-vivo animal testing to demonstrate substantial equivalence to an existing device, not an AI or software algorithm.
Here's a breakdown of why each section of your request cannot be fulfilled from the provided text:
- Table of acceptance criteria and reported device performance: Not present. The "Performance Data" section lists various tests (e.g., Visual Inspection, Paste Stiffness, Package Leak Test) and states that they "met specification" or "passed," but it does not provide specific numerical acceptance criteria or quantitative performance results.
- Sample sized used for the test set and the data provenance: Not present for a "test set" in the context of an algorithm. The in-vivo animal testing mentions demonstrating substantial equivalence in "an animal model," but does not specify the sample size of animals or their provenance.
- Number of experts used to establish the ground truth for the test set and the qualifications of those experts: Not applicable. Ground truth for an AI algorithm is not relevant here. The in-vivo animal testing involved "histopathologic evaluation," which would have been performed by experts, but their number and qualifications are not specified.
- Adjudication method: Not applicable.
- MRMC comparative effectiveness study: Not applicable, as this is not an AI-assisted device.
- Standalone performance (algorithm only without human-in-the-loop): Not applicable, as this is not an AI/algorithm device.
- Type of ground truth used: For the in-vivo animal testing, "histopathologic evaluation" served as a form of ground truth for assessing the bone defect repair.
- Sample size for the training set: Not applicable, as there is no training set for an AI algorithm.
- How the ground truth for the training set was established: Not applicable.
Summary based on available information:
The document describes the regulatory clearance of a bone putty device (Permatage Settable Bone Putty) based on its substantial equivalence to another marketed device (Stryker HydroSet Injectable Cement). The evaluation involved:
- Biocompatibility Testing: Conducted in accordance with ISO 10993, including tests for cytotoxicity, irritation, sensitization, systemic toxicity, genotoxicity, local tissue toxicity, hemolysis, pyrogenicity, and neurotoxicity. All tests were conducted on the final, finished, gamma-irradiation sterilized device and in accordance with GLP requirements.
- Bench Testing:
- Visual Inspection: Evaluated paste color using a reference scale. Conclusion: Paste color met specification.
- Paste Stiffness: Evaluated paste stiffness using a reference scale. Conclusion: Paste stiffness met specification.
- Package Leak Test: Bubble emission leak test. Conclusion: All test articles passed.
- Temperature Sensitivity: Acceptable maximum temperature increase observed. Conclusion: Acceptable maximum temperature increase observed.
- Water Uptake, Swelling, and Dissolution: Measured volume and mass changes over time. Conclusion: Acceptable water uptake, swelling, and dissolution.
- In-Vivo Testing:
- Study Design: Used to demonstrate substantial equivalence in the repair of a critical-sized cranial bone defect in an animal model compared to the comparator device.
- Ground Truth: Substantial equivalence was assessed based on histopathologic evaluation.
- Sample Size/Provenance: Not specified beyond "an animal model."
- Clinical Testing: No clinical studies were conducted in support of this 510(k).
The document concludes that the device is substantially equivalent to the predicate device, and the conducted tests passed stated requirements and recognized standards.
Ask a specific question about this device
(158 days)
Trade/Device Name: Montage Flowable Settable, Resorbable Bone Paste Regulation Number: 21 CFR 882.5300
| Class IIGXP21 CFR 882.5300
Orthocon Montage Flowable Settable Bone Paste is a self-setting calcium phosphate cement indicated for use in the repair of neurosurgical burr holes, contiguous cranial defects with a surface area no larger than 25cm2. Montage Flowable Settable, Resorbable Bone Paste should be used only in skeletally mature individuals.
Montage Flowable Settable, Resorbable Bone Paste is a sterile, biocompatible, resorbable material for use in repair of cranial defects. The Montage Flowable device comprises two separate components of putty consistency containing granular calcium phosphate, calcium stearate, vitamin E acetate, a triglyceride, polyalcohols and a mixture of a lactide-diester and polyester-based polymers. When mixed together, the components of the Montage Flowable device form a cohesive putty-like material that adheres to the bone surface and remains in place following application. The resulting hardened, resorbable material is primarily calcium phosphate. Montage Flowable components must be mixed immediately prior to use.
The provided document is a 510(k) summary for the Orthocon Montage Flowable Settable, Resorbable Bone Paste. This document is a premarket notification for a medical device and is not a study proving the device meets acceptance criteria for an AI/ML-based medical device.
The document discusses:
- The device's name, regulation, and product code.
- Its intended use (repair of neurosurgical burr holes, cranial defects).
- Comparisons of technological characteristics with a predicate device (Stryker HydroSet Injectable Cement).
- Biocompatibility and performance testing (bench testing and in-vivo animal testing).
- A clear statement that no clinical studies have been conducted in support of this 510(k).
Therefore, the requested information about acceptance criteria and a study proving device performance for an AI/ML-based medical device cannot be extracted from this document, as it pertains to a different type of medical device (a bone paste) and the regulatory submission is not based on AI/ML performance.
To answer your prompt, I would need a document describing the regulatory submission for an AI/ML-based medical device, which would typically include detailed information on clinical performance studies, ground truth establishment, expert adjudication, and sample sizes for training and test sets.
Ask a specific question about this device
(143 days)
Re: K231475
Trade/Device Name: MONTAGE-QS Settable, Resorbable Bone Putty Regulation Number: 21 CFR 882.5300
|
| Regulation: | 21 CFR 882.5300
Orthocon MONTAGE-OS Settable Bone Putty is a self-setting calcium phosphate cement indicated for use in the repair of neurosurgical burr holes, contiguous cranial defects with a surface area no larger than 25cm². MONTAGE-QS Settable, Resorbable Bone Putty should be used only in skeletally mature individuals.
MONTAGE-QS Settable, Resorbable Bone Putty is a sterile, biocompatible, resorbable material for use in repair of cranial defects. The MONTAGE-QS device comprises two separate components of putty consistency containing granular calcium phosphate, calcium stearate, vitamin E acetate, a triglyceride, polyalcohols and a mixture of a lactide-diester and polyesterbased polymers. When mixed together, the components of the MONTAGE-QS device form a putty-like material. The resulting hardened, resorbable material is primarily calcium phosphate. MONTAGE-QS components must be mixed immediately prior to use.
The provided text describes a medical device, MONTAGE-QS Settable, Resorbable Bone Putty, and its substantial equivalence to a predicate device. However, it does not explicitly detail acceptance criteria and a study proving the device meets those criteria in the context of typical AI/software device evaluation.
Based on the provided information, here's an attempt to answer your request, focusing on the information that is present and noting where information is absent for an AI device.
1. A table of acceptance criteria and the reported device performance
The document does not explicitly state "acceptance criteria" in the way one would for an AI model's performance metrics (e.g., AUC, sensitivity, specificity thresholds). Instead, the performance evaluation is based on demonstrating equivalence to a predicate device through various tests. The "performance" for MONTAGE-QS is a qualitative assessment of its material properties and biological response compared to the predicate.
| Test Category | Specific Test | Acceptance Criteria (Implied/Compared) | Reported Device Performance (MONTAGE-QS) |
|---|---|---|---|
| Efficacy | Cranioplasty in rabbit critical-sized defect | Equivalence to HydroSet in filling bone defects (histology-based) | MONTAGE-QS performance for cranioplasty was judged to be equivalent to HydroSet. |
| Bench Testing | Visual Inspection (Putty component color) | Met specification | Putty color met specification. |
| Putty Stiffness | Met specification | Putty stiffness met specification. | |
| Putty Vitamin E Acetate Concentration | Met specification | Putty vitamin E acetate concentration met specification. | |
| Hand Mixing Time | Met specification (related to mixing time, stickiness, mixability) | Mixing time, stickiness, and mixability met specification. | |
| Hand Mixing Stickiness | Met specification (related to mixing time, stickiness, mixability) | Mixing time, stickiness, and mixability met specification. | |
| Mixability | Met specification (related to mixing time, stickiness, mixability) | Mixing time, stickiness, and mixability met specification. | |
| Package Leak Test | All test articles passed | All test articles passed. | |
| Temperature Sensitivity | Acceptable maximum temperature increase following hand-mixing | Acceptable maximum temperature increase following hand-mixing. | |
| Water Uptake, Swelling, and Dissolution | Acceptable water uptake, swelling and dissolution | Acceptable water uptake, swelling and dissolution. | |
| In-Vivo Testing | Histopathologic evaluation (critical sized cranial bone defect) | Substantial equivalence to predicate device (HydroSet) through histopathologic evaluation | Substantial equivalence was assessed from histopathologic evaluation (compared to predicate). |
| Biocompatibility | ISO 10993 (Cytotoxicity, irritation, systemic toxicity, genotoxicity, local tissue toxicity, hemolysis, pyrogenicity, neurotoxicity) | Compliance with ISO 10993 recommendations | Conducted in accordance with ISO 10993 recommendations and GLP requirements. |
2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)
- Test Set Sample Size:
- Efficacy Evaluation (Cranioplasty): The study was conducted in a "rabbit cranial critical-sized defect model." The specific number of rabbits or defects studied is not provided.
- Bench Testing: The sample sizes for each bench test are not specified.
- In-Vivo Testing: Similar to the efficacy evaluation, it refers to an "animal model" without giving specific numbers.
- Data Provenance: The document states "rabbit cranial critical-sized defect model" and "in-vivo animal testing," indicating the data is from preclinical animal studies. The country of origin and whether it was retrospective or prospective data are not specified.
3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)
- The "ground truth" for this device's evaluation (e.g., whether bone defects were filled, or histopathological assessments) would have been established by experts in veterinary pathology or relevant scientific fields. However, the document does not state the number of experts or their qualifications. The assessments are described as "histology-based assessments" and "histopathologic evaluation."
4. Adjudication method (e.g. 2+1, 3+1, none) for the test set
- The document does not describe any adjudication method for establishing ground truth or evaluating the test results.
5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance
- This is a submission for a bone putty, not an AI or software device. Therefore, an MRMC comparative effectiveness study involving human readers and AI assistance is not applicable and was not performed.
6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done
- This is a submission for a bone putty, not an AI or software device. Therefore, a standalone algorithm performance study is not applicable and was not performed.
7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)
- For the efficacy and in-vivo testing, the ground truth was based on histopathologic evaluation in an animal model. For bench testing, it was based on measurable physical and chemical properties against predetermined specifications.
8. The sample size for the training set
- This is a submission for a physical medical device (bone putty), not an AI or software device. Therefore, the concept of a "training set" in the context of machine learning is not applicable. The device's performance is demonstrated through testing against specifications and comparison to a predicate, not by training an algorithm.
9. How the ground truth for the training set was established
- As a training set is not applicable for this type of device, the method for establishing its "ground truth" is not applicable.
Ask a specific question about this device
(196 days)
Re: K221933
Trade/Device Name: MONTAGE Settable, Resorbable Bone Putty Regulation Number: 21 CFR 882.5300
|
| Product codes: | GXP |
| Regulation: | 21 CFR 882.5300
Orthocon MONTAGE Settable, Resorbable Bone Putty is a self-setting calcium phosphate cement indicated for use in the repair of neurosurgical burr holes, contiguous cranial defects with a surface area no larger than 25cm². MONTAGE Settable, Resorbable Bone Putty should be used only in skeletally mature individuals.
MONTAGE Settable, Resorbable Bone Putty is a sterile, biocompatible, resorbable material for use in repair of cranial defects. The MONTAGE device comprises two separate components of putty consistency containing granular calcium phosphate, calcium stearate, a triglyceride, a polyalcohol and a mixture of a lactide-diester and polyester-based polymers. When mixed together, the components of the MONTAGE device form a putty-like material. The resulting hardened, resorbable material is primarily calcium phosphate. MONTAGE components must be mixed immediately prior to use.
The provided document does not describe the acceptance criteria and a study proving a digital health device meets acceptance criteria. Instead, it is a 510(k) premarket notification for a medical device called "MONTAGE Settable, Resorbable Bone Putty."
Therefore, I cannot provide the information requested in points 1-9 as they pertain to the evaluation of a digital health device, specifically looking for metrics like human reader improvement with AI assistance, standalone algorithm performance, and details about training/test sets for AI models.
Instead, the document details the substantial equivalence of the MONTAGE Settable, Resorbable Bone Putty to a predicate device (Stryker Injectable Cement) based on technological characteristics and performance data.
Here's a summary of what the document does provide regarding the MONTAGE device's performance evaluation:
-
Acceptance Criteria and Reported Device Performance (Bench Testing):
The document lists several bench tests with their conclusions, implying that the "met specification" or "acceptable" status indicates the device met its acceptance criteria for these specific properties.Test Acceptance Criteria (implied by "met specification" or "acceptable") Reported Device Performance Visual Inspection Putty color and handling met specification Putty color and handling met specification Putty Handling Putty stickiness met specification Putty stickiness met specification Putty Stiffness Putty stiffness met specification Putty stiffness met specification Putty Vitamin E Acetate Concentration Putty vitamin E acetate concentration met specification Putty vitamin E acetate concentration met specification Hand Mixing Time Mixing time met specification Mixing time met specification Hand Mixing Stickiness Stickiness met specification Stickiness met specification Mixability Mixability met specification Mixability met specification Device Stiffness Device stiffness met specification Device stiffness met specification Package Gross Leak All test articles passed leak test All test articles passed Temperature Sensitivity Acceptable maximum temperature increase following hand-mixing Acceptable maximum temperature increase following hand-mixing Water Uptake, Swelling, and Dissolution Acceptable water uptake, swelling and dissolution Acceptable water uptake, swelling and dissolution -
Sample size used for the test set and the data provenance: Not applicable for a medical device without AI components. However, biocompatibility testing was conducted on the "final, finished, gamma-irradiation sterilized device," and in-vivo animal testing was performed using "New Zealand White rabbits."
-
Number of experts used to establish the ground truth for the test set and the qualifications of those experts: Not applicable.
-
Adjudication method for the test set: Not applicable.
-
If a multi reader multi case (MRMC) comparative effectiveness study was done: No, this is not an AI-assisted device.
-
If a standalone (i.e. algorithm only without human-in-the-loop performance) was done: Not applicable, as it's a physical medical device.
-
The type of ground truth used:
- Biocompatibility: In accordance with ISO 10993 recommendations and GLP requirements.
- Bench Testing: Internal specifications derived from engineering and material science principles.
- In-Vivo Testing: Histopathologic evaluation and histomorphometric measurements of implant absorption over time from animal study, compared to the predicate device.
-
The sample size for the training set: Not applicable for this type of medical device.
-
How the ground truth for the training set was established: Not applicable.
Ask a specific question about this device
(265 days)
#509 Chevy Chase, Maryland 20815
Re: K182742
Trade/Device Name: DB-Cranial Regulation Number: 21 CFR 882.5300
|
| Classification #: | 21 CFR 882.5300
DB-Cranial is a calcium phosphate bone void filler indicated for the repair or filling of neurosurgical burr holes or other cranial bone defects and craniotomy cuts with a surface area no larger than 25 cm2. DB-Cranial may be used in the restoration or augmentation of bony contours of the cranial bone skeleton.
DB-Cranial Bone Void Filler is a moldable and biocompatible calcium phosphate bone void filler. DB-Cranial kit is comprised of two components: a calcium-phosphate powder and a mixing solution in premeasured quantities, which will be mixed together prior to implantation. The 3 cc, 5 cc, and 10 cc DB-Cranial Bone Void Filler kits are provided sterile to SAL of 10-6 and are for single use only. The sterilization method is gamma radiation. Sterilization validation is based on ISO 11137-2:2013 (VDMax25). DB-Cranial Bone Void Filler will be labeled with a shelf life of 30 months.
The document provided is a 510(k) summary for the DB-Cranial device. It describes various performance tests conducted to demonstrate substantial equivalence to a predicate device, OsteoVation® Impact (K162864).
Here's an analysis of the acceptance criteria and study information, based on the provided text:
Important Note: This document does not describe a study that uses AI or machine learning. It is a submission for a medical device (a calcium phosphate bone void filler) that undergoes physical and chemical performance testing to demonstrate substantial equivalence. Therefore, many of the requested bullet points regarding AI/ML studies (e.g., sample size for test set, data provenance, ground truth, experts, MRMC, standalone performance, training set) are not applicable to this type of device submission.
1. Table of Acceptance Criteria and Reported Device Performance
The acceptance criteria for DB-Cranial were established by comparing its performance to that of the predicate device, OsteoVation® Impact (K162864). The "Results" column essentially serves as the reported device performance and also confirms that the device meets the implied acceptance criteria of being substantially equivalent to the predicate.
| Test | Test Method Summary | Acceptance Criteria (Implied) | Reported Device Performance and Substantial Equivalence |
|---|---|---|---|
| Working Time In-Vitro | Ensures sufficient manipulation time and setting strengths. Mixing, mold-ability, and setting strengths were measured. | Sufficient indentation loads to ensure targeted working time and setting strength. | Both subject and predicate device reached sufficient indentation loads to ensure targeted working time and setting strength. |
| Setting Time | Setting tests determined strength (Mean $\geq$ 450N and $\geq$ 700N) at specified time points post sterilization and post mixing. | Similar setting strengths to predicate at all time points. Strength values substantially equivalent. | Subject and predicate devices achieved similar setting strengths at all time points. Strength values of these two setting cements are substantially equivalent. |
| Ca to P Ratio | This test determines CA/P ratios via ICP-MS. | Ca/P ratio of 1.5, identical to the predicate device. | Both samples have a Ca/P ratio of 1.5. This test confirms both subject and predicate are composed of identical amounts of calcium and phosphate salts. |
| Kit Components | Kit ingredients are compared to determine substantial equivalence. | Consist of alpha-tricalcium phosphate (Powder) and sodium silicate-sodium phosphate solution (Liquid), identical to the predicate. | Both subject and predicate device consist of alpha-tricalcium phosphate (Powder) and sodium silicate-sodium phosphate solution (Liquid). |
| Heavy Metal Analysis | Samples are analyzed for trace heavy metal content using ICP-MS. | Trace metal limits below allowable limits. | Trace metal limits were below allowable limits in both subject and predicate. |
| pH Profile | Examines effects of the device on pH surrounding the implanted device. pH is measured in physiologic buffer solutions surrounding curing cements. | All pH readings remained within normal physiological range. | All pH readings remained within normal physiological range for both predicate and subject devices. |
| FTIR Analysis | Identifies the chemical composition following curing in simulated physiologic conditions. | Both subject and predicate device show the formation of hydroxyapatite. Substantially equivalent. | Both subject and predicate device both show the formation of hydroxyapatite. Subject and predicate device are substantially equivalent with regards to FTIR chemical analysis. |
| Crystallographic Analysis | XRD analysis with samples set in simulated physiologic conditions for 2 hours, 1 day, 3 days, and 7 days. Compared against known mineralogic standards. | Confirmed identical crystallographic analysis to predicate over several clinically relevant time points. | Both subject and predicate device are confirmed identical via crystallographic analysis. The same crystalline structure over several different clinically relevant time points is formed in both materials. |
| Temperature Profile | Device samples tested in simulated physiologic solutions to measure temperature of curing cement at 2-minute intervals over 20 minutes. | Set in an isothermic manner with minimal risk of thermal necrosis. Substantially equivalent. | Both subject and predicate device set in an isothermic manner as designed. This demonstrates a minimal risk of thermal necrosis of tissue surrounding the implantation site. In this respect, both subject and predicate device are substantially equivalent. |
| Solubility and Dissolution | Test samples cured and incubated at simulated physiological conditions for 4 days; fluid extracted and tested for Ca2+ concentration via ICP-AES. | Substantially equivalent solubility and dissolution to predicate. | Both subject and predicate device have substantially equivalent solubility and dissolution. |
| Tensile Testing | Test samples mixed and cured for 24 hours at simulated temperature and pH. Tensile testing performed using a mechanical tester. | Identical tensile strength at 24 hours to predicate. Substantially equivalent. | Subject and predicate device demonstrated identical tensile strength at 24 hours and are substantially equivalent in terms of tensile strength. |
| Dimensional Stability | Dimensional stability measured to establish that the bone void fillers maintain shape and do not dissolve in an untimely manner. | Dimensionally stable with no discernable differences from predicate. | Subject and predicate are dimensionally stable materials with no discernable differences in form. |
| Physical Form | Test samples imaged by SEM to determine microstructural similarities and differences. | Demonstrated hydroxyapatite crystal formation identical to predicate. | Both subject and predicate device demonstrated hydroxyapatite crystal formation. Subject and predicate device set to form hydroxyapatite in an identical manner. |
2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)
- Test Set Sample Size: The document does not specify the exact number of samples used for each test (e.g., number of specimens for tensile testing, number of batches for chemical analysis). The tests are typically conducted on a sufficient number of samples to ensure statistically sound results for material characterization.
- Data Provenance: The data provenance is generally from laboratory bench testing (in vitro simulations). The country of origin of the data is not explicitly stated, but it would typically be where the manufacturer (Dimensional Bioceramics, LLC, Santa Cruz, CA) or their contracted laboratories are located. The testing is prospective for the device being submitted, although it involves comparison to an already marketed predicate.
3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)
This is not applicable as the study involves physical and chemical property testing of a biomaterial, not subjective interpretation by medical experts. The "ground truth" for these tests comes from established scientific and engineering principles (e.g., ASTM/ISO standards for material testing, analytical chemistry techniques).
4. Adjudication method (e.g. 2+1, 3+1, none) for the test set
Not applicable, as there is no subjective adjudication required for quantitative and qualitative material property tests.
5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance
Not applicable. This is not an AI/ML-driven diagnostic or assistive device.
6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done
Not applicable. This is not an AI/ML device.
7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)
The "ground truth" for the performance tests is derived from:
- Established material science and engineering principles.
- Quantitative measurements made by validated analytical equipment (e.g., ICP-MS, XRD, mechanical testers).
- Qualitative observations based on scientific methodologies (e.g., FTIR, SEM).
- The performance of the legally marketed predicate device, used as a benchmark for "substantial equivalence."
8. The sample size for the training set
Not applicable. This is not an AI/ML device.
9. How the ground truth for the training set was established
Not applicable. This is not an AI/ML device.
Ask a specific question about this device
(92 days)
Cupertino, California 95014
Re: K162864
Trade/Device Name: OsteoVation Impact Regulation Number: 21 CFR 882.5300
Osteo Vation Impact is a calcium phosphate bone void filler indicated for the repair or filling of neurosurgical burr holes, other cranialbone defects and craniotomy cuts with a surface area no larger than 25cm2. OsteoVation Impact may be used in the restoration or augmentation of bony contours of the cranialbone skeleton.
OsteoVation Impact is a self-setting, calcium phosphate bone void filler designed for single use and biocompatible. Osteo Vation Impact is an impactable (moldable) calcium phosphate.
OsteoVation Impact is comprised of two working components: a calcium phosphate, a sodium phosphate (SPMA), carboxymethylcellulose powder, a sodium silicate, sodium phosphate (SPMA) solution, and a mixing system (mixing bowl, pestle and spatula). The two working components are packaged separately and are to be mixed together by the end user prior to implantation.
OsteoVation Impact is offered in 3cc, 5cc, and 10cc sterile convenience kits. Each kit includes the two working components in combination with a mixing bowl, pestle, and spatula. It is sterilized using gamma radiation with a minimum dose of 25 kGy and a maximum dose of 50 kGy with a Sterility Assurance Level of 10-9.
The provided text describes the OsteoVation Impact, a calcium phosphate bone void filler. The submission focuses on demonstrating substantial equivalence to a predicate device (OsteoVation® CMF Bone Void Filler, K051784) rather than establishing novel acceptance criteria for a new type of device. Therefore, the "acceptance criteria" discussed here relate to ensuring the modified device maintains performance comparable to the predicate.
Here's an analysis based on your requested information:
1. Table of Acceptance Criteria and Reported Device Performance:
The document doesn't explicitly state "acceptance criteria" in a quantitative, pass/fail table format with specific numerical targets for each test, but it describes how results were evaluated against the predicate device. The performance is consistently stated as "comparable to the predicate device" or "PASS," implying that the results fell within acceptable ranges established by the predicate's performance.
| Test | Test Method Summary | Acceptance Criteria (Implicit) | Reported Device Performance |
|---|---|---|---|
| Working time | Tests performed to determine the workability time of the cement, including mixing and molding of the paste. | Comparable to the predicate device. | All samples passed the targeted working time and setting strength. The test results demonstrated working time comparable to the predicate device. |
| Setting Time | Testing conducted to determine the Setting strength (Mean ≥ 450N and ≥ 700N) at various time points in a target temperature solution, post-sterilization after a target working time. | Mean ≥ 450N and ≥ 700N; Comparable to the predicate device. | All samples passed the targeted setting time. The test results demonstrated setting time comparable to the predicate device. |
| Tensile Strength | Evaluated subject device minimum tensile strength at 24 hours. Samples prepared through mortal/pestle combination into molds in varying diameters and thickness, placed in a prepared solution at 37°C for 24 hours. Tested using a mechanical testing system. | Comparable to the predicate device. | PASS. The test results demonstrated tensile strength comparable to the predicate device. |
| Temperature Profile | Subject device mixed and placed into a centrifuge tube and into a 37°C water bath. Temperature profile recorded at specified intervals using a computer controlled thermocouple for 24 hours. | Comparable to the predicate device. | PASS. The test results demonstrated temperature profile comparable to the predicate device. |
| pH Profile | Subject device mixed and placed into a centrifuge tube and into a 37°C water bath. pH recorded at specified intervals using a calibrated probe with a TC temperature compensator. Evaluates physiological characteristics. | Comparable to the predicate device. | PASS. The test results demonstrated pH profile comparable to the predicate device. |
| FTIR Analysis | Mix and incubate subject device for 24 hours. Dry cured sample at 37°C for 72 hours. Perform 64 scans at typical resolution of 4cm-1. Determines the formation of hydroxyapatite. | Nearly identical hydroxyapatite structure as the predicate device. | PASS. FTIR analysis show nearly identical hydroxyapatite structure as the predicate device. |
| Crystallographic Analysis | Analyze prepared sample using x-ray diffractometer (XRD). Perform Rietveld analysis to determine ratios of each compound in cured cement. | Comparable results as the predicate device. | PASS. XRD analysis show comparable results as the predicate device. |
2. Sample Size Used for the Test Set and the Data Provenance:
The document does not explicitly state the sample sizes (number of devices, batches, or specimens) used for each bench test. It mentions "All samples" passed for working and setting time but doesn't quantify "all."
The data provenance is bench testing conducted by Skeletal Kinetics, LLC. There's no mention of country of origin for data as it's mechanical/chemical testing. The tests are prospective for the modified device to demonstrate its performance.
3. Number of Experts Used to Establish the Ground Truth for the Test Set and the Qualifications of Those Experts:
N/A. This being a bench test study for a material, there isn't a "ground truth" established by experts in the typical sense (e.g., radiologist consensus for image analysis). The "ground truth" is derived from the objective physical and chemical properties and performance of the device and its comparison to a well-characterized predicate.
4. Adjudication Method for the Test Set:
N/A. This is not applicable to bench testing of material properties. The results are physical measurements and chemical analyses, not subjective assessments requiring adjudication.
5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:
N/A. This study is for a medical device (bone void filler material), not an AI diagnostic or assistance tool. Therefore, MRMC studies and AI effect sizes are not relevant.
6. If a Standalone (i.e. algorithm only without human-in-the-loop performance) was done:
N/A. As above, this is about a physical medical device, not an algorithm.
7. The type of ground truth used:
The "ground truth" for this submission is the established performance characteristics and material composition of the predicate device (OsteoVation® CMF Bone Void Filler, K051784). The goal of the study was to demonstrate that the modified OsteoVation Impact has comparable physical, chemical, and performance characteristics to this predicate, ensuring that the formulation change did not adversely affect its safety and efficacy.
8. The sample size for the training set:
N/A. This is not a machine learning or AI study, so there is no concept of a "training set."
9. How the ground truth for the training set was established:
N/A. There is no training set in this context.
Ask a specific question about this device
(253 days)
200 Portage, Michigan 49002
Re: K143661 Trade/Device Name: DirectInject® Regulation Number: 21 CFR 882.5300
|
| Classificationname: | Methyl methacrylate for cranioplasty (882.5300
DirectInject is a self-setting, calcium phosphate cement intended to repair neurosurgical burr holes, contiguous craniotomy cuts and other cranial defects not intrinsic to the stability of the bony structure. It is also intended for augmentation or restoration of bony contour in the craniofacial skeleton to include the cranial and zygomatic bones. DirectInject is intended to repair cranial defects with a surface area of 4 cm2 or less.
DirectInject is indicated for patients in whom skeletal growth is complete. It can be used in patients with surgically created bone defects.
Stryker DirectInject consists of a sterile dual paste system, provided pre-filled in a double barrel delivery syringe system, which is calcium phosphate based. Upon injection through the Mixer-Cannula, the two pastes form a cement paste which is injectable, moldable and biocompatible. The injected cement paste will harden under normal body conditions to form hydroxyapatite, which is the principle mineral constituent of bone. The contents are supplied sterile for single patient use in sizes of 3 cc, 5 cc, and 10 cc.
The provided text is a 510(k) summary for the Stryker DirectInject device, which is a calcium phosphate cement for cranioplasty. It focuses on demonstrating substantial equivalence to predicate devices rather than providing a performance study with acceptance criteria in the typical sense of a clinical trial for diagnostic devices. Therefore, much of the requested information regarding diagnostic performance, ground truth, experts, and sample sizes for training/test sets is not applicable to this type of submission.
However, I can extract information related to the performance data provided to support the safety and effectiveness of the device, primarily through biocompatibility and bench testing.
Here's a breakdown of the information that can be extracted from the provided text, addressing the points where applicable:
1. Table of Acceptance Criteria and Reported Device Performance
The document doesn't present acceptance criteria in a table format with corresponding numerical performance metrics for a diagnostic device. Instead, it describes performance testing conducted to demonstrate safety and effectiveness for a medical device (cranioplasty cement).
The acceptance criteria are implied by the standards the device was tested against. The "reported device performance" is generally stated as the device having passed these tests and performing as intended.
| Characteristic | Test | Standard/Guidance | Implied Acceptance Criteria | Reported Device Performance |
|---|---|---|---|---|
| Biocompatibility | Cytotoxicity | ISO-10993-5 | Material is non-cytotoxic. | Device passed. |
| Irritation | ISO-10993-10 & ISO-10993-2 | Material is non-irritating. | Device passed. | |
| Sensitization | ISO-10993-10 & ISO-10993-2 | Material is non-sensitizing. | Device passed. | |
| Acute systemic toxicity | ISO-10993-11 & ISO-10993-2 | Material does not cause acute systemic toxicity. | Device passed. | |
| Genotoxicity (various) | ISO-10993-3 & ISO-10993-2 | Material is not genotoxic. | Device passed. | |
| Haemocompatibility | ISO-10993-4 & ASTM F756 | Material is haemocompatible. | Device passed. | |
| Sub-Chronic Toxicity | ISO-10993-11 & ISO-10993-2 | Material does not cause sub-chronic toxicity. | Device passed. | |
| Chronic toxicity | ISO-10993-11 & ISO-10993-2 | Material does not cause chronic toxicity. | Device passed. | |
| Neurotoxicity (8 weeks) | ISO-10993-6 & ISO-10993-2 | Material is not neurotoxic. | Device passed. | |
| Physical Properties | X-ray diffraction | International Centre for Diffraction Data (ICDD) | Chemical composition matches expected for hydroxyapatite. | Device passed (implies intended chemical characterization was met). |
| Fourier Transform Infrared | N/A | Spectroscopic profile matches expected for hydroxyapatite. | Device passed (implies intended chemical characterization was met). | |
| X-ray Fluorescence | N/A | Elemental composition matches expected. | Device passed (implies intended chemical characterization was met). | |
| Porosity | ASTM D4404-10, ASTM D4284-12 | Porosity within acceptable limits for a bone void filler intended for osteointegration. | Device passed (implies porosity was within specified ranges). | |
| pH testing | USP <791> | pH is within physiologically acceptable range. | Device passed (implies pH was within specified ranges). | |
| Setting time | N/A | Setting time is appropriate for surgical use. | Device passed (implies setting time was within specified ranges for clinical utility). | |
| Dimensional stability | N/A | Maintains shape and volume over time, without significant degradation or expansion. | Device passed (implies dimensional stability was within acceptable limits). | |
| Setting reaction temperature | N/A | Reaction temperature does not cause tissue damage. | Device passed (implies exotherm was within acceptable limits for safety). | |
| Injectability force | N/A | Injectability force is within ergonomic limits for surgeons. | Device passed (implies injectability force was within specified ranges). | |
| Performance | Compressive Strength | N/A | Compressive strength is sufficient for indicated use (non-load-bearing, temporary support). | Device passed (implies compressive strength was within specified ranges for functional integrity). |
| Max supported defect strength | N/A | Ability to repair defects of specified size (4 cm²) and provide adequate temporary support without structural failure. | Device passed (implies it can support the indicated defect size). | |
| Shelf life Assessment | ICH Q1A(R2) | Device maintains characteristics and sterility over specified shelf life. | Device passed (implies shelf life was adequately determined and justified). | |
| In-Vivo Testing | Local effects in sheep & rabbit model | ISO-10993-2 and ISO-10993-6 and "Class II Special Controls Guidance Document: Resorbable Calcium Salt Bone Void Filler Device; Guidance for Industry and FDA" | Material is stable, osteoconductive, and integrates with bone without adverse local effects. | "These studies demonstrated that Stryker DirectInject is stable, osteoconductive, and integrates with the bone tissue surrounding the defect site." (This implies all aspects of local effects, stability, and osteoconductivity were met). |
2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)
- Test Set Sample Size: For the in-vivo animal studies, the document mentions "a sheep and rabbit model." It does not specify the exact number of animals used in these models.
- Data Provenance: The biocompatibility and bench testing are laboratory-based. The in-vivo animal studies are conducted in animal models, likely in a research facility accredited with animal welfare standards. Country of origin for the data is not specified, but the submitter is Stryker Leibinger GmbH & Co. KG (Germany) with regulatory contact in Michigan (USA).
3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)
- This information is not applicable. The device is a bone cement, not a diagnostic AI device requiring expert consensus for ground truth. The "ground truth" for biocompatibility and material properties is established by adherence to recognized international standards and scientific testing methodologies. For the animal study, macroscopic and histological evaluations would typically be performed by trained veterinary pathologists, but the number and qualifications are not specified.
4. Adjudication method (e.g. 2+1, 3+1, none) for the test set
- This is not applicable as it relates to expert review for diagnostic ground truth, which is not part of this submission type.
5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance
- This is not applicable. This is a medical device (bone cement), not a diagnostic AI system.
6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done
- This is not applicable. This is a medical device (bone cement), not a diagnostic algorithm.
7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)
- For biocompatibility: Ground truth is defined by the passing criteria of the specified ISO and ASTM standards.
- For physical properties: Ground truth is defined by the expected material characteristics (e.g., hydroxyapatite composition, mechanical strength, setting time) as measured against the respective standards and internal specifications.
- For in-vivo testing: Ground truth is established by macroscopic and histological evaluation demonstrating stability, osteoconductivity, and integration with bone tissue, as interpreted by qualified personnel (e.g., veterinary pathologists).
8. The sample size for the training set
- This is not applicable for a non-AI medical device submission.
9. How the ground truth for the training set was established
- This is not applicable for a non-AI medical device submission.
Ask a specific question about this device
(266 days)
Regulation Number | 882.55250 | 888.3045 | 882.5300
| 882.5300 | 882.5250
TRS Cranial Bone Void Filler is intended for use in the repair of 13mm neurosurgical cranial burr holes. It should be gently packed into bony voids or gaps of the skeletal system that are not intrinsic to the stability of the bony structure.
TRS Cranial Bone Void Filler (TRS C-BVF) is a synthetic, porous, osteoconductive, bone void filler made from PCL polycaprolactone (CaH100-)X which will degrade and resorb fully in vivo by hydrolysis and is subsequently metabolized by the body, and hydroxylapatite (Ca10(PO4)6.(OH)2) with a calcium phosphate bone mineral coating (Hydroxylapatite and Octacalcium phosphate). TRS BVF has an interconnected porous structure that acts as an osteoconductive matrix for the ingrowth of bone.
TRS C-BVF is available in single size, which is a 13mm diameter x 5mm "plug" with a 20mm diameter x .90mm thick flange.
TRS C-BVF is manufactured using a laser sintering process and is then coated with the calcium phosphate bone mineral coating. The product is shipped to a contract manufacturer who packages, labels and sterilizes the C-BVF devices. They are then returned to TRS and inventoried as Finished Goods.
Acceptance Criteria and Study for TRS Cranial Bone Void Filler (TRS C-BVF)
This document describes the acceptance criteria and the study performed to demonstrate the substantial equivalence of the Tissue Regeneration Systems Cranial Bone Void Filler (TRS C-BVF) to its predicate devices, as presented in 510(k) Premarket Notification K123633.
1. Acceptance Criteria and Reported Device Performance
The acceptance criteria for TRS C-BVF were not explicitly stated as numerical thresholds for specific performance metrics in the provided document. Instead, the study aimed to demonstrate "comparable performance" or "similar performance" to predicate devices across various tests. Therefore, the "acceptance criteria" are implied by the demonstration of substantial equivalence to already cleared devices.
The reported device performance is summarized in the table below, based on the non-clinical testing performed.
| Performance Characteristic | Acceptance Criteria (Implied) | Reported Device Performance (TRS C-BVF) |
|---|---|---|
| Biocompatibility | Non-cytotoxic, non-sensitizer, non-irritant, no acute systemic toxicity, non-mutagenic, non-clastogenic, non-pyrogenic, no evidence of systemic toxicity, non-hemolytic, minimal activator of intrinsic coagulation pathway. (Demonstrate compliance with ISO 10993 standards akin to predicate devices). | Cytotoxicity (ISO 10993-5): No cytotoxicity or cell lysis, reactivity grade 0. Sensitization (ISO 10993-10): No evidence of causing delayed dermal contact sensitization. Intracutaneous Reactivity (ISO 10993-10): No erythema/edema or very slight with difference from control ≤ 1.0. Systemic Toxicity (Acute) (ISO 10993-11): No mortality or evidence of systemic toxicity. Genotoxicity (Gene mutation) (ISO 10993-3): Non-mutagenic. Genotoxicity (in-vivo) (ISO 10993-3): Non-clastogenic. Genotoxicity (Mouse Lymphoma) (ISO 10993-3): Non-mutagenic. Local effects (2wks) (ISO 10993-6): Non-irritant compared to negative control (HDPE) and ChronOS. Local effects (6wks) (ISO 10993-6): Non-irritant compared to ChronOS, slight irritant compared to HDPE. Pyrogen study (USP) (ISO 10993-11): Non-pyrogenic after retest. Sub-chronic toxicity (13wks) (ISO 10993-11): No evidence of systemic toxicity, local reaction not significant compared to HDPE. Chronic toxicity (26wks) (ISO 10993-11): No evidence of systemic toxicity, local reaction not significant compared to HDPE, moderate irritant compared to HDPE (expected mild macrophage/giant cell response). Hemolysis (ASTM F756): Non-hemolytic. PTT (ASTM F2382): Averaged 77% of negative control (passed as minimal activator). C3a/SC5b-9 Complement Activation (ISO 10993-4): Statistically significantly higher than controls (attributed to surface-related phenomenon, not a direct blood-contacting device). |
| Material Degradation | Comparable degradation mechanism and profile to ChronOS predicate; qualitatively similar polymeric material components to Osteopore PCL Scaffold predicate. | Polymer degradation (ISO 10993-13): Similar PCL degradation mechanism (hydrolysis). TRS C-BVF lost 10-23% molecular weight and 0.26-0.47% mass at 365-730 days. ChronOS showed faster degradation (57% reduction at 30 days, 90% at 90 days, completely degraded by 540 days). TRS device is in the first stage of degradation. Ceramic degradation (ISO 10993-14): Both extreme and simulation tests demonstrated ceramic component is calcium and phosphate. Heavy metal elements within acceptable limits. FTIR Analysis: FTIR results showed strong peaks consistent with PCL for both TRS C-BVF and Osteopore PCL Scaffold, indicating PCL as a major component. Degradation for Osteopore material (and thus TRS C-BVF) presumed similar to TRS C-BVF. |
| Mechanical Properties | Comparable compressive mechanical properties and push-out force to predicate devices (chronOS and Osteopore PCL). | Bench testing showed comparable performance in compressive mechanical properties and push-out force to chronOS and Osteopore devices. |
| Bone Ingrowth/Healing | Similar performance to predicate ChronOS device in new bone formation in an animal model, demonstrating facilitation of constant, sustained bony healing response. | Rabbit Calvarial Defect Testing: Similar performance to predicate ChronOS device with respect to new bone formation. Total bone formation approximately equal by 26 weeks, nearly identical bone volumes by 78 weeks (CT). |
Note: The FDA's 510(k) clearance process focuses on demonstrating "substantial equivalence" to a legally marketed predicate device rather than meeting predefined, quantitative acceptance criteria for novel claims. The reported performance aims to show that the new device is as safe and effective as the predicate.
2. Sample Sizes and Data Provenance
The document does not explicitly state a general "test set" sample size in the context of a single uniform study. Instead, different sample sizes were used for various non-clinical tests:
- Biocompatibility Tests (ISO 10993 series):
- Cytotoxicity (ISO 10993-5): Not specified, but standard in-vitro test.
- Sensitization (Guinea pig maximization test) (ISO 10993-10): "All animals" (implies a typical number for this test, usually around 10-20 guinea pigs for a maximization test).
- Intracutaneous Reactivity (ISO 10993-10): Not specified.
- Systemic Toxicity (Acute) (ISO 10993-11): "Mice" (implies a typical number for acute toxicity, often 3-5 mice per extract).
- Genotoxicity (Bacterial Reverse Mutation) (ISO 10993-3): Standard in-vitro assay using specific Salmonella typhimurium and Escherichia coli tester strains, not a sample size of devices.
- Genotoxicity (in-vivo; Mouse Peripheral Blood Micronucleus Study) (ISO 10993-3): "Mice" (implies a typical number, usually 5-6 mice per group).
- Genotoxicity (Mouse Lymphoma Assay) (ISO 10993-3): Standard in-vitro assay using L5178Y/TK+/- cell line.
- Local effects after Implantation (Muscle implantation study in rabbits) (ISO 10993-6): "Rabbits" for 2 and 6-week studies (typically small groups, e.g., 3-5 rabbits per group).
- Pyrogen study (USP) (ISO 10993-11): Initial test: 3 animals. Retest: 5 additional animals (total 8 rabbits).
- Sub-chronic toxicity (13 week study) (ISO 10993-11): "Rats" (small groups, e.g., 5-10 rats per sex/group).
- Chronic toxicity (26 week study) (ISO 10993-11): "Rats" (similar to sub-chronic, small groups).
- ASTM F756 Hemolysis Test: Standard in-vitro test, not a patient sample size.
- Partial Thromboplastin Time (PTT): Standard in-vitro test, not a patient sample size.
- C3a/SC5b-9 Complement Activation Assay: Standard in-vitro test, not a patient sample size.
- Polymer degradation (ISO 10993-13): Samples of TRS C-BVF and ChronOS incubated over various time points (30, 90, 180, 365, 540, 730 days), likely duplicate/triplicate samples per time point.
- Ceramic degradation (ISO 10993-14): Coated and uncoated discs tested in extreme and simulation solutions.
- Bench Testing: Not specified, but involved multiple samples of TRS C-BVF and predicate devices for mechanical property measurements.
- Animal Testing (Rabbit Calvarial Defect testing): "Rabbits" (implies a typical number for animal models, usually in groups of 6-12 animals per test/control arm).
Data Provenance: The studies described are pre-clinical (in-vitro and animal). The country of origin for the studies is not explicitly stated, but they are generally performed in GLP-certified labs, often in the US or other countries with established regulatory testing standards. The data is prospective in the sense that these tests were specifically conducted to support this 510(k) submission.
3. Number of Experts and Qualifications for Ground Truth
This type of submission (510(k) for a bone void filler) does not typically involve human expert readers establishing ground truth in the way defined for image-based diagnostic AI devices. The ground truth for the pre-clinical studies was established through:
- Laboratory assays and measurements: For biocompatibility, mechanical properties, and degradation, the "ground truth" is the objective result of the standardized test method (e.g., cell viability count, force measurement, chemical analysis, animal health observations).
- Histopathological evaluation: For the animal (rabbit) study, the "ground truth" for new bone formation would have been established by a pathologist (likely a veterinary pathologist or a pathologist specializing in bone/tissue histomorphometry) examining tissue samples from the defect sites. The number of pathologists and their specific years of experience are not mentioned in this summary but would be part of the full study report.
4. Adjudication Method for the Test Set
Not applicable. As described above, the "test set" consists of laboratory and animal study results, not a set of human-interpreted cases requiring adjudication.
5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study
No. An MRMC comparative effectiveness study is designed for diagnostic imaging devices where multiple human readers interpret cases to assess diagnostic accuracy, often with and without AI assistance. TRS C-BVF is a bone void filler, not a diagnostic device, so this type of study is not relevant to its clearance.
6. Standalone (Algorithm Only) Performance
No. This device is a physical medical implant, not an algorithm or AI software. Therefore, the concept of "standalone performance" for an algorithm is not applicable.
7. Type of Ground Truth Used
The ground truth for the various studies includes:
- Standardized laboratory measurements and observations: For biocompatibility (e.g., cell counts, dermal reactions, organ weights, histopathology, chemical analysis).
- Mechanical engineering data: For bench testing (e.g., force/stress measurements).
- Histological and imaging evaluation (CT): For animal studies, assessing new bone formation and volume.
8. Sample Size for the Training Set
Not applicable. This device is a physical medical implant, not an AI/ML algorithm that requires a training set.
9. How the Ground Truth for the Training Set Was Established
Not applicable. As there is no AI/ML algorithm involved, there is no training set or associated ground truth establishment process.
Ask a specific question about this device