    K Number
    K110205

    Validate with FDA (Live)

    Date Cleared
    2011-02-09

    (15 days)

    Product Code
    Regulation Number
    886.1570
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    AA10 Wireless Regulation Number: 21 CFR 882.1570 Regulation Name: Opthalmoscope Regulatory Class: Class

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    AAIO-7 & AAIO Wireless, is a head mounted Binocular Indirect ophthalmoscope designed to be Used by trained personnel for illuminating and viewing parts of the eye such as the Cornea and retina when used in conjunction with an ophthalmic lens.

    Binocular Indirect Ophthalmoscope provides an illumination system to direct appropriately, focused light into the eye in order to obtain an intermediate image of the fundus (retina) that is viewed by the observer to diagnose the eye.

    Device Description

    Binocular Indirect ophthalmoscope: AAIO-7 AAIO WIRELESS

    AI/ML Overview

    I am sorry, but the provided documentation does not contain the information required to answer your request regarding acceptance criteria and a study proving a device meets them. The text primarily consists of an FDA clearance letter for a device and its indications for use. There is no mention of:

    • Acceptance criteria tables or reported device performance
    • Details of a study, including sample sizes, data provenance, ground truth establishment, or expert qualifications
    • Adjudication methods
    • MRMC studies or effect sizes
    • Standalone algorithm performance
    • Training set details

    Therefore, I cannot fulfill your request based on the given input.

    Ask a Question

    Ask a specific question about this device

    K Number
    K974208

    Validate with FDA (Live)

    Device Name
    TYTRON C-3000
    Date Cleared
    1998-02-03

    (85 days)

    Product Code
    Regulation Number
    882.1570
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    temperature measurement deviceNeurological Devices Classification Panel21 Code of Federal Regulations 882.1570

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The TyTron C-3000 is indicated for use in detecting, measuring, recording, and graphing the skin surface temperature on both sides of the spine of adults and children by professional health care providers. It is to be used before and after therapy is rendered as part of monitoring the patient's response to care.

    Device Description

    The TyTron C-3000 is a hand held paraspinal thermographic scanning system. It consists of two probes which each contain infrared sensors designed to be placed on either side of the spinal column to detect temperatures. With the aid of a computer assisted program the system is capable of recording and graphing thermal differentials (right to left thermal asymmetries) on a horizontal scale. It also records direct temperatures on the vertical scale.

    AI/ML Overview

    Here's an analysis of the provided information regarding the TyTron C-3000, addressing your specific questions:


    Acceptance Criteria and Study for TyTron C-3000

    The provided document describes the TyTron C-3000, a hand-held paraspinal thermographic scanning system, and compares it to a predicate device, Thermatrax, to establish substantial equivalence. The "study" in this context is a technical comparison of device specifications to demonstrate that the TyTron C-3000 performs as well as or better than the predicate device for specified technical parameters. This is not a clinical trial in the sense of patient outcomes or diagnostic effectiveness.

    1. Table of Acceptance Criteria and Reported Device Performance

    The acceptance criteria are implicitly defined by the performance characteristics of the predicate device, Thermatrax. The TyTron C-3000 demonstrates performance that meets or exceeds these criteria.

    TestAcceptance Criteria (Predicate: Thermatrax)Reported Device Performance (TyTron C-3000)Meets Criteria?
    Accuracy± 1°C± 1°CYes
    Orientation of sensorsParallel, 2" centersParallel, 1.85" centersYes (Similar)
    Filtering circuitYesYesYes
    Sensitivity± 0.05°C± 0.01°CYes (Better)
    Reproducibility± 0.10°C± 0.05°CYes (Better)
    Accuracy, odometerNot applicable± 0.25 cmN/A (New feature/test)
    Sensor WavelengthMust contact skin6 - 14 micrometersYes (Broader/Different)

    2. Sample Size Used for the Test Set and Data Provenance

    The document does not describe a clinical "test set" in the traditional sense of patient data. The "testing" referred to is a comparison of technical specifications against a predicate device. Therefore, a sample size for a test set and data provenance (country of origin, retrospective/prospective) are not applicable in this context. The testing is focused on the inherent device characteristics and performance.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications

    This information is not provided. Given that the "study" is a technical comparison of device specifications, it's unlikely that external experts were used to establish a "ground truth" for a test set in the way one would for diagnostic imaging. The performance parameters (accuracy, sensitivity, reproducibility) would typically be verified by engineering and quality control processes.

    4. Adjudication Method

    Not applicable. There is no mention of a human-adjudicated test set or a need for an adjudication method like 2+1 or 3+1.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was done

    No, a multi-reader multi-case (MRMC) comparative effectiveness study was not conducted. This document outlines a 510(k) submission for substantial equivalence based on technical specifications and indications for use, not a clinical effectiveness study involving human readers and interpretation. Therefore, an effect size of human readers improving with AI vs without AI assistance is not applicable.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) was done

    Yes, in a way. The performance metrics of the device (accuracy, sensitivity, reproducibility) are standalone measures of the device's technical capabilities without inherent human-in-the-loop performance measurement. The device itself performs the sensing and data recording. The "algorithm" here is the device's inherent measurement and processing capability.

    7. The Type of Ground Truth Used

    The "ground truth" for the technical specifications is the established engineering standards for measurement accuracy, sensitivity, and reproducibility. These are fundamental physical properties and performance characteristics of the sensors and the system as a whole, typically verified through calibration and controlled laboratory testing. The predicate device's specifications serve as the benchmark for substantial equivalence.

    8. The Sample Size for the Training Set

    Not applicable. The TyTron C-3000 is a measurement device, not an AI/machine learning algorithm requiring a separate training set of data. Its performance is based on its physical design, sensor technology, and electronic processing, all of which are established during the device's design and manufacturing process, not through statistical learning from a training dataset.

    9. How the Ground Truth for the Training Set was Established

    Not applicable, as there is no training set in the context of an AI/machine learning algorithm. The "truth" for the device's design and engineering would be based on fundamental physics, sensor calibration standards, and established electronic design principles.