Found 142 results

510(k) Data Aggregation

    K Number
    K253236

    Validate with FDA (Live)

    Device Name
    G-BLOCK
    Date Cleared
    2025-09-29

    (0 days)

    Product Code
    Regulation Number
    872.3690
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    . |
    | Classification | 21 CFR 872.3690 21 CFR 872.3770 | 21 CFR 872.3690 21 CFR 872.3770 21 CFR 872.3760
    | 21 CFR 872.3690 21 CFR 872.3770 | Same as Reference Device Equivalent to Primary Predicate |

    Page

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    G-BLOCK is intended to be used for the fabrication of permanent and temporary restorations such as dental implant prostheses, crowns, bridges, inlays, onlays and veneers.

    Device Description

    G-BLOCK is a compact block made of graphene-doped polymer suitable for the manufacture of dental prostheses using CAD/CAM technology. The polymer is based on polymethyl methacrylate (PMMA) doped with graphene (an allotrope of carbon).

    G-BLOCK is intended to be used for the fabrication of permanent and temporary restorations such as dental implant prostheses, crowns, bridges, inlays, onlays and veneers.

    G-BLOCK, compounded of polymethyl methacrylate (PMMA) doped with Graphene, is manufactured using the heat-curing method.

    G-BLOCK presents high modulus and elastic limit to ensure that the tensions generated during biting and chewing do not cause permanent deformations, and it is possible to manufacture prosthesis of smaller sections.

    G-BLOCK presents high deformation resistance and stress limit, thus avoiding the formation of cracks and fractures.

    G-BLOCK is low density making the prosthesis lightweight.

    G-BLOCK increases the material hardness comparing with acrylic resins used in dentistry.

    G-BLOCK has colour stability.

    G-BLOCK has wide chromatic range, even within the same piece, making it look extremely natural.

    G-BLOCK is chemically inert.

    G-BLOCK water absorption is 4 μg/mm³ and a solubility of 0.5 μg/mm². The release of residual monomer is minimum, with a percentage of 0.004% of residual monomer. Thanks to these physical properties G-BLOCK offers a durable and safety treatment.

    G-BLOCK is available in different formats, sizes and colors, having all variations the same physicochemical characteristics.

    The device is presented in the form of a polymer block glued to an aluminum pin that allows the device to be fixed on the milling machine so that the block can be milled to obtain dental prostheses with the use of specific CAD/CAM equipment.

    G-BLOCK is available in 2 different formats: MONOCHROMA and MULTICHROMA. Monochrome and Multichroma blocks may be both used for anatomical monolithic restorations.

    When machined, Monochroma and Multichroma present a different visual effect:

    • Monochroma, is made of a pure colour matching the dentin.

    • Multichroma, has a chromatic spectrum based on the natural colour imitating the optical effects of the natural dentition.

    Both variants are presented in two sizes: 14 and 40.

    G-BLOCK device is available in the following colours, A1, A2, A3, A3.5, B1, B2, BL1, BL2, C2 (according to G-CAM shade guide).

    G-BLOCK are provided non-sterile and as a single use device.

    G-BLOCK must be used only by professionals as dental lab technicians and / or dentist.

    G-BLOCK should be stored at room temperature in its original packaging, in dry storage and avoid exposure to direct sunlight. PMMA polymer from which the G-BLOCK is made is stable and can be stored for an extended period of 5-year shelf life.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K251271

    Validate with FDA (Live)

    Date Cleared
    2025-06-23

    (60 days)

    Product Code
    Regulation Number
    872.3770
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    K251271**
    Trade/Device Name: TempFIT Temporary Crown and Bridge Resin
    Regulation Number: 21 CFR 872.3770
    name: Temporary Crown and Bridge Resin
    Classification name: Material, Tooth Shade, Resin (21 CFR 872.3770

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The product is a self-curing composite for the fabrication of temporary crowns, bridges, inlays, onlays and veneers.

    Device Description

    TempFIT Temporary Crown and Bridge Resin is a self-curing composite for the fabrication of temporary crowns, bridges, inlays, onlays and veneers. The mixing ratio, based on volume, base paste: catalyst paste =1:1 or 10:1. TempFIT Temporary Crown and Bridge Resin is delivered in a bio-cartridge. The curing mechanism between methacrylates is self-curing, which fundamentally belongs to free radical polymerization in reaction principle. Free radical polymerization typically occurs in unsaturated molecules containing double bonds. Both methacrylate resins in TempFIT Temporary Crown and Bridge Resin and silane coupling agents on filler surfaces contain numerous carbon-carbon unsaturated double bonds. When the two-component system is mixed, a redox reaction generates abundant free radicals that initiate the polymerization of these double bonds.

    AI/ML Overview

    This FDA 510(k) clearance letter is for TempFIT Temporary Crown and Bridge Resin. It addresses the substantial equivalence of this device to a legally marketed predicate device (Luxatemp Ultra/Star, K101710).

    However, this document does not describe the kind of AI/ML device study that would typically involve acceptance criteria related to accuracy, sensitivity, specificity, and the use of expert readers for ground truth establishment. Instead, it focuses on the equivalence of a dental biomaterial product based on its physical, chemical, and biological properties.

    Therefore, I cannot directly extract the detailed information requested regarding acceptance criteria and a study proving device performance in the context of an AI/ML medical device. The document describes a non-clinical testing approach for a dental material.

    Here's how I can address your request based on the provided text, while highlighting the limitations:

    Acceptance Criteria and Device Performance (Based on Non-Clinical Testing for a Dental Material):

    Acceptance Criteria (Physical Properties)Reported Device Performance (TempFIT Temporary Crown and Bridge Resin)
    Appearance: Visual inspection shows no foreign impurities in the paste.Passed: Visual inspection shows no foreign impurities in the paste.
    Colour: The colours of the material show no more than a slight difference with the colour indicated by the manufacturer.Passed: The colours of the material show no more than a slight difference with the colour indicated by the manufacturer.
    Working time: ≥50sPassed: ≥50s
    Setting time: ≤10minPassed: ≤10min
    Surface finish: A test specimen polished has a glossy surface.Passed: A test specimen polished has a glossy surface.
    Flexural strength: ≥50MPaPassed: ≥50MPa
    Water sorption: ≤40μm/mm³Passed: ≤40μm/mm³
    Solubility: ≤7.5μm/mm³Passed: ≤7.5μm/mm³

    Study Details (Non-Clinical for a Dental Material):

    1. Sample size used for the test set and the data provenance:

      • The document mentions "test results demonstrated the qualification and substantial equivalence." However, it does not specify the sample sizes of the materials tested for each physical property.
      • Data Provenance: The tests were performed according to ISO 10477 and Internal standard SOP of the company (HUGE SOP). Given the submitter's location (Rizhao City, China), the testing was likely conducted in China. The study is a non-clinical, laboratory-based performance test, not involving patient data.
    2. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

      • Not applicable in this context. The "ground truth" for chemical and physical properties are established through standardized laboratory measurement techniques as per ISO standards and the company's internal SOPs, not through expert human interpretation in the way AI/ML ground truth is established.
    3. Adjudication method (e.g., 2+1, 3+1, none) for the test set:

      • Not applicable. This is a non-clinical material test, not a subjective human-reading assessment.
    4. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

      • No. This type of study is relevant for AI-assisted diagnostic devices. This submission concerns a dental biomaterial.
    5. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done:

      • Not applicable. This is not an algorithm-based device.
    6. The type of ground truth used:

      • The "ground truth" for the physical and chemical properties of the temporary crown and bridge resin are the established measurement protocols and thresholds defined by ISO 10477 and the company's internal SOPs. These are objective, quantitative measurements (e.g., MPa for flexural strength, µm/mm³ for water sorption).
    7. The sample size for the training set:

      • Not applicable. This is not an AI/ML device that requires a training set. The "development" of the material would involve chemical formulation and iterative testing, but not a "training set" in the computational sense.
    8. How the ground truth for the training set was established:

      • Not applicable, as there is no training set for this type of device.

    In summary, the provided FDA clearance letter demonstrates a material's safety and effectiveness through adherence to established material standards and comparison to a predicate device, rather than through an AI/ML performance study.

    Ask a Question

    Ask a specific question about this device

    K Number
    K243370

    Validate with FDA (Live)

    Device Name
    DentaTOOTH
    Manufacturer
    Date Cleared
    2025-05-05

    (187 days)

    Product Code
    Regulation Number
    872.3770
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    , NSW 2065
    AUSTRALIA

    Re: K243370
    Trade/Device Name: DentaTOOTH
    Regulation Number: 21 CFR 872.3770
    resin |
    | Classification Name | Crown And Bridge, Temporary, Resin |
    | Regulation Number | 872.3770
    Product code EBG under regulation 21 CFR 872.3770 is defined as:
    'A temporary crown and bridge resin

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Asiga DentaTOOTH is intended exclusively for professional dental work. Asiga DentaTOOTH is a 3D print resin indicated for the manufacturing of 3D printed temporary crowns, bridges, inlays, onlays and veneers.

    Device Description

    DentaTOOTH is a resin material used by dental professionals for the manufacture of temporary dental restorations including temporary crowns, bridges, inlays, onlays and veneers. DentaTOOTH resin is available in six Vita shades A1, A2, A3, B1, B2, B3.

    DentaTOOTH resins are used with digital light processing (DLP) based 3D printers to produce denture temporary dental restorations. DentaTOOTH resin has been validated for use with the Asiga Max Series and Pro Series printers for the manufacture of temporary dental restorations at 385nm wavelengths.

    DentaTOOTH is a light-cure methacrylate-based resin with photoinitiator, UV absorber, dispersant and pigments. DentaTOOTH is a Type 2, Class 2 resin per ISO 10477:2020 and Type 1, Class 2, Group 2 resin per ISO 4049:2019.

    DentaTOOTH has a shelf life of 36 months. The device may be stored in Asiga Max and Pro Series printers for up to 4 weeks with hood closed.

    DentaTOOTH is compliant to ISO 10477:2020 and ISO 4049:2019 for polymer based crown and veneering materials, and polymer based restorative materials, respectively.

    AI/ML Overview

    The provided FDA 510(k) clearance letter for DentaTOOTH is for a temporary crown and bridge resin, not an AI-powered diagnostic device. Therefore, the information requested regarding acceptance criteria and studies that prove the device meets these criteria (such as MRMC studies, ground truth establishment, expert consensus, etc.) are not applicable to this type of device.

    The 510(k) summary clearly states:

    • Device Name: DentaTOOTH
    • Common Name: Temporary crown and bridge resin
    • Classification Name: Crown And Bridge, Temporary, Resin
    • Regulation Number: 872.3770 (which corresponds to Temporary Crown And Bridge Resin)
    • Product Code(s): EBG

    The documentation details non-clinical tests performed in accordance with specific ISO standards relevant to dental materials (ISO 10477:2020 for Polymer-based crown and veneering materials and ISO 4049:2019 for Polymer-based restorative materials). These tests evaluate material properties such as:

    • Depth of cure
    • Surface finish
    • Flexural strength
    • Water sorption
    • Solubility
    • Shade consistency
    • Color stability
    • Packaging validation
    • Shelf life
    • Biocompatibility (according to ISO 10993-1:2018)

    The clearance is based on the substantial equivalence of DentaTOOTH's material properties and indications for use to legally marketed predicate devices, as demonstrated by these material-specific performance tests.

    Therefore, I cannot provide a response to your numbered points as they are designed for the evaluation of AI/ML or diagnostic devices, which is not what DentaTOOTH is.

    The questions you posed are typical for the regulatory review of Software as a Medical Device (SaMD) with AI/ML components, particularly those involved in image analysis or diagnosis where performance is measured by metrics like sensitivity, specificity, or reader agreement. DentaTOOTH is a material, not a software or diagnostic device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K243621

    Validate with FDA (Live)

    Date Cleared
    2025-04-22

    (151 days)

    Product Code
    Regulation Number
    872.3770
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Colorado 80127

    Re: K243621
    Trade/Device Name: Evoblock, Perléon
    Regulation Number: 21 CFR 872.3770
    Colorado 80127

    Re: K243621
    Trade/Device Name: Evoblock, Perléon
    Regulation Number: 21 CFR 872.3770

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Indication for use:

    • Temporary anterior and posterior crowns;
    • Implant and abutment supported prosthetics;
    • Partial, complete and hybrid denture prosthetics (base and teeth).
    Device Description

    Not Found

    AI/ML Overview

    This FDA 510(k) clearance letter pertains to dental materials (Temporary Crown And Bridge Resin) and does not contain any information about an AI/ML medical device, its acceptance criteria, or the study that proves the device meets those criteria.

    Therefore, I cannot extract the requested information regarding:

    • Acceptance Criteria Table: There is no mention of performance metrics like sensitivity, specificity, or AUC.
    • Sample Size and Data Provenance: No details about test sets, training sets, countries of origin, or retrospective/prospective studies.
    • Expert Ground Truth: No information about the number or qualifications of experts or how ground truth was established.
    • Adjudication Method: No mention of 2+1, 3+1, or any other adjudication process.
    • MRMC Study: No indication of a multi-reader, multi-case comparative effectiveness study or related effect sizes.
    • Standalone Performance: No data on the algorithm's performance without human intervention.
    • Type of Ground Truth: No mention of pathology, outcomes data, or expert consensus.
    • Training Set Sample Size and Ground Truth Establishment: No information provided.

    The document is solely a regulatory approval for a physical dental product, not a software or AI/ML device requiring performance evaluation against clinical ground truth.

    Ask a Question

    Ask a specific question about this device

    K Number
    K243951

    Validate with FDA (Live)

    Date Cleared
    2025-02-21

    (60 days)

    Product Code
    Regulation Number
    872.3770
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    TAIWAN

    Re: K243951

    Trade/Device Name: TEMP MASTER, PMMA-based dental resin Regulation Number: 21 CFR 872.3770
    |
    | Classification Panel: | Dental Device |
    | Regulation Number: | 872.3770
    |
    | Regulation Number: | 872.3760, 872.3770
    | 872.3770
    | 872.3770, 872.3760

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    TEMP MASTER, PMMA-based dental resin developed by Taiwan Dental Materials CO., LTD. is a self-cured resin indicated for the fabrication of short-term restorations including temporary inlays, crowns, and bridges, which can protect or restore damaged teeth while permanent restorations are being prepared. It is a traditional auto-cured PMMA-based resin composed of powder and liquid. Polymerization occurs when the powder and liquid are mixed at room temperature.

    Device Description

    TEMP MASTER, PMMA-based dental resin, is a self-curing (cold-cure) material designed to fabricate temporary crowns and bridges. It consists of two components: powder and liquid. Polymerization occurs when the powder and liquid are mixed at room temperature. Classified as a Type 1 (autopolymerizable) acrylic resin according to ISO 10477 standards, TEMP MASTER, PMMA-based dental resin provides reliable performance for temporary restorations.

    AI/ML Overview

    This document describes a 510(k) premarket notification for a dental material, not an AI/ML powered device. Therefore, much of the requested information regarding AI/ML device studies (such as sample sizes for test and training sets, data provenance, number of experts, adjudication methods, MRMC studies, standalone performance, and ground truth types) is not applicable.

    However, I can extract the acceptance criteria and reported device performance based on the provided bench testing information for the TEMP MASTER, PMMA-based dental resin.

    Here's the information as it relates to the provided document:

    1. A table of acceptance criteria and the reported device performance

    Performance CharacteristicAcceptance Criteria (ISO 10477)Reported Device Performance (TEMP MASTER, PMMA-based dental resin)
    Flexural Strength>50 MPa>50 MPa
    Water AbsorptionComplies with ISO 10477Complies with ISO 10477
    Water SolubilityComplies with ISO 10477Complies with ISO 10477

    2. Sample sized used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    • Sample Size: The document does not specify the exact sample sizes used for the bench tests. It only states that "the nonclinical tests conducted in accordance with ISO 10477 assessed the flexural strength, water sorption, and water solubility."
    • Data Provenance: The bench testing was performed to support the 510(k) submission from "Taiwan Dental Materials CO., LTD." The data would therefore originate from Taiwan, likely conducted prospectively for regulatory submission.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    Not applicable. This is a dental material, and the performance is evaluated through objective physical and chemical bench testing against international standards (ISO 10477). There were no human experts involved in establishing a "ground truth" in the way it's understood for AI/ML diagnostic devices.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    Not applicable. As this involves physical/chemical testing, there is no "adjudication method" in the context of human interpretation or consensus. The tests would be performed according to standardized protocols and the results measured objectively.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This is a medical device (dental material), not an AI/ML algorithm requiring human interpretation.

    6. If a standalone (i.e. algorithm only without human-in-the loop performance) was done

    Not applicable. This is a medical device (dental material), not an AI/ML algorithm.

    7. The type of ground truth used (expert concensus, pathology, outcomes data, etc)

    The "ground truth" for the device's performance is established by international standards for dental materials (ISO 10477). These standards define the acceptable ranges and methodologies for evaluating physical and chemical properties like flexural strength, water absorption, and water solubility.

    8. The sample size for the training set

    Not applicable. This is a medical device (dental material), not an AI/ML algorithm that requires a "training set."

    9. How the ground truth for the training set was established

    Not applicable. This is a medical device (dental material), not an AI/ML algorithm.

    Ask a Question

    Ask a specific question about this device

    K Number
    K243336

    Validate with FDA (Live)

    Date Cleared
    2024-12-17

    (54 days)

    Product Code
    Regulation Number
    872.3760
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Resin, Denture, Relining, Repairing, Rebasing Temporary Crown and Bridge Regulation Number 872.3760 872.3770

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    · Lucitone Digital Print™ 3D Denture Base is a light-cured resin indicated for the fabrication of denture bases including full and partial dentures* and implant overdentures.
    · Lucitone Digital IPN™ 3D Premium Tooth is a light-cured resin intended for printing denture teeth. Lucitone Digital Value™ 3D Economy Tooth & Trial Placement is intended for use as:
    · Printing resin for fabricating removable dentures for try-in and evaluation prior to fabrication of the final denture.*
    · Printing resin for fabricating a temporary denture.
    · Printing resin for fabricating denture teeth in full arches and segments that will subsequently be fused into a denture base.
    · Printing resin for fabricating provisional crowns, bridges.**
    • Lucitone Digital Fuse™ Step 1 – 3D Tooth Conditioning Agent is indicated for use in enhancing the bond of denture teeth to denture base and denture base to denture base.
    · Lucitone Digital Fuse™ Step 2 - 3D Denture Bonding Resin is utilized as an aid in bonding denture teeth to denture base as well as repair using traditional techniques.
    · Lucitone Digital Fuse™ Step 3 – Total 3D Sealer is a light-cured sealant that produces a smooth, glossy surface finish on the denture.
    *Partial and full dentures are replacement for patients with missing teeth.†
    **For instructions on printing provisional crowns and bridges with Lucitone Digital Value reference Section G in IFU
    +Statement added for EU MDR alignment.

    Device Description

    Lucitone Digital Value™ (LDV) 3D Economy Tooth & Trial Placement, which is part of the Lucitone Digital Print™ Denture (LDPD) System, is a methacrylate-based resin system which is used to fabricate dental prostheses using an additive printer and computer aided design and computer aided manufacturing (CAD/CAM) technologies.

    AI/ML Overview

    I am sorry, but the provided text does not contain the detailed information necessary to answer your request about acceptance criteria and the study that proves the device meets them. The document is an FDA 510(k) summary for a dental device (Lucitone Digital Print Denture™ System) that describes the device, its indications for use, and a few performance tests.

    Specifically, the following information is not present in the text:

    • A comprehensive table of acceptance criteria and reported device performance. While some performance metrics are listed (Flexural Strength, Flexural Modulus, Water Sorption, Water Solubility), these are general and not presented as specific acceptance criteria with corresponding performance test results. For example, for "Flexural Strength," it only states "≥50 MPa" as the acceptance criterion, but it does not report the actual performance value obtained for the subject device.
    • Sample size used for the test set and data provenance. The document only mentions "In all instances, the subject device functioned as intended and all test results observed were as expected," without providing details about the test set.
    • Number of experts used to establish ground truth and their qualifications.
    • Adjudication method.
    • If a multi-reader multi-case (MRMC) comparative effectiveness study was done, or the effect size of human improvement with AI assistance. This device is a denture system, not an AI or diagnostic tool, so an MRMC study is highly unlikely to be relevant.
    • If a standalone (algorithm only without human-in-the-loop performance) study was done. This is not applicable to a physical dental device.
    • The type of ground truth used. This is not applicable in the context of a physical materials performance study.
    • Sample size for the training set. This is not applicable as it's not an AI model.
    • How the ground truth for the training set was established. This is not applicable as it's not an AI model.

    The document mainly focuses on demonstrating substantial equivalence to a predicate device through non-clinical performance data (material properties) and biocompatibility, rather than a clinical study evaluating diagnostic or treatment efficacy that would typically involve test sets, ground truth, and expert adjudication. The "Performance Data" section explicitly states, "Clinical and Pre-clinical testing were not necessary to demonstrate equivalence."

    Ask a Question

    Ask a specific question about this device

    K Number
    K231859

    Validate with FDA (Live)

    Device Name
    PrimmaArt
    Manufacturer
    Date Cleared
    2024-11-26

    (522 days)

    Product Code
    Regulation Number
    872.3770
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Fort Lauderdale, Florida 33309

    Re: K231859

    Trade/Device Name: PrimmaArt Regulation Number: 21 CFR 872.3770
    and bridge resin

    Proprietary Name: PrimmaArt

    Product Code: EBG

    Class: Class II

    Regulation: 21 CFR 872.3770

    | 21 CFR 872.3770

    | 21 CFR 872.3770

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    • Fabrication of temporary crowns, bridges, inlays, onlays and veneers;
    • Fabrication of long-lasting temporary restorations;
    • Rebasing of prefabricated temporary crowns made of composite, polycarbonate or metal.
    Device Description

    Self-curing composite that is highly efficient for the production of temporary pieces for indirect dental procedures such as inlays, onlays, crowns, veneers and bridges. The product consists of a base paste and a catalyzing paste stored in a cartridge and in a double-body syringe, from where they are automatically dispensed in the correct proportion (1:1), providing practical clinical procedures with reduced chances of errors or incorporated bubbles.

    AI/ML Overview

    The provided text is a 510(k) summary for the device PrimmaArt, a temporary crown and bridge resin. It describes the device, its indications for use, comparison with a predicate device (Structur 3), and non-clinical testing results.

    However, the document does not contain information regarding a study involving human readers, ground truth establishment, sample sizes for test or training sets, or expert qualifications for AI/ML device performance analysis. The acceptance criteria and "device performance" in the context of this document refer to physical and chemical properties of the dental resin, not the performance of an AI/ML algorithm.

    Therefore, I cannot provide the requested information for acceptance criteria and study details related to an AI/ML device per the input prompt's structure. The device described, PrimmaArt, is a material, not a software or AI/ML device.

    However, I can extract the acceptance criteria and reported device performance for the dental resin based on the provided tables:

    1. Table of Acceptance Criteria and Reported Device Performance (for PrimmaArt dental resin):

    TestAcceptance Criteria (Specification)Reported Device Performance (Results)
    Setting time and heat releasedSetting time: No more than 5 minutes (EN ISO 4049). Project target: 2'30" - 3'10". Heat released: Less than 0.60 mW/mg.Setting time: 2m48s. Heat released: 0.30 mW/mg. (Product evaluated using DSC and presented results according to design input).
    ViscosityBase and catalyzer viscosity: Between 60000 and 100000 mPa.s (according to design input).Base Paste: 92733 mPa.s. Catalyst paste: 90133 mPa.s. (Results within defined limits).
    Surface FinishPolymerized composite presents a reflective surface (ISO 10477).Surface of specimen was reflective (in accordance with ISO 10477).
    Shade consistency and color stabilityNo more than a small color change (EN ISO 4049 and ISO 7491).Only a small color difference (acceptable according to ISO 4049) was attested in one comparison; no changes identified in other analyses.
    RadiopacityValue > 1.0 mm when compared to aluminum scale (ISO 4049).1.68 mm. (FGM Bisacrylic resin presented results above that specified by ISO 4049).
    Flexing ResistanceFlexural strength ≥ 50MPa (ISO 10477).65.5 MPa. (All results within values specified in ISO 10477).
    Water sorption and solubilitySorption: Maximum of 40 µg/mm³. Solubility: Maximum of 7.5 µg/mm³ (ISO 4049).Sorption: 9.389 ± 1.26 µg/mm³. Solubility: 1.542 ± 0.32 µg/mm³. (All results below within the specified limit).
    Working timeAt least 60 seconds (EN ISO 4049 for cementation materials).More than 60 seconds.
    Accelerated Stability StudiesProduct should not show significant changes in physical-chemical properties after accelerated degradation (study created to accelerate degradation).Did not show significant changes in terms of its physical-chemical properties during the accelerated stability process (225 days).
    Long-Term Stability (Shelf)Verify physical and chemical characteristics during expected shelf life to confirm expiration date.No conclusive data about shelf life yet; estimated 2 years shelf life based on accelerated stability test.
    Microhardness VickersHardness (HV) between 5 and 15 HV, and similar or superior to competitor (Project Entry Requirements).11.81 HV. (All results within the specified limit).

    2. Sample size used for the test set and the data provenance:

    • This information is not applicable as the study involves material testing, not an AI/ML algorithm or dataset. The tests are performed on samples of the PrimmaArt resin. The data provenance is DentsCare LTDA, Brazil, as the manufacturer.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

    • Not applicable as this is not an AI/ML device. Ground truth, in this context, refers to the adherence of the material's properties to international standards (e.g., ISO) and internal design inputs.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set:

    • Not applicable as this is not an AI/ML device evaluated by human readers. The assessment is based on direct measurement against established material performance standards.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    • Not applicable as this is not an AI/ML device.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

    • Not applicable as this is not an AI/ML device. The performance tests are for the material itself.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

    • For the non-clinical testing of the dental resin, the "ground truth" or reference for acceptance is defined by recognized international standards (e.g., ISO 7491, ISO 10477, ISO 4049) and the device's internal design input specifications.

    8. The sample size for the training set:

    • Not applicable as this is not an AI/ML device. There is no concept of a "training set" for a dental resin material in this context.

    9. How the ground truth for the training set was established:

    • Not applicable as this is not an AI/ML device.
    Ask a Question

    Ask a specific question about this device

    K Number
    K242559

    Validate with FDA (Live)

    Device Name
    Digital Temp
    Manufacturer
    Date Cleared
    2024-11-26

    (90 days)

    Product Code
    Regulation Number
    872.3770
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Los Angeles, California 90065

    Re: K242559

    Trade/Device Name: Digital Temp Regulation Number: 21 CFR 872.3770
    --------------------------|----------------------------------|
    | Regulation Number: | 21 CFR 872.3770

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    SprintRay Digital Temp is a light-curable resin indicated for the fabrication of individual and fixed temporary full single crowns, temporary partial crowns, and temporary bridges. The material is an alternative to traditional restorative dental material.

    Device Description

    SprintRay Digital Temp is a photo-polymer methacrylate resin material used in conjunction with a 3D printer and a scanned 3D image in a dental office to build dental prosthetics by 3D printing layer of the composite material. SprintRay Digital Temp resin is offered in various shades such as Bleach, A1, A2 and B1. Digital Temp is an alternative to traditional dental prosthesis material that is intended exclusively for professional dental work.

    SprintRay Digital Temp resin is intended exclusively for professional dental work. Fabrication of dental prosthetics with SprintRay Digital Temp resin requires computer-aided design and CAD/CAM manufacturing system that includes the following components not part of the device: Digital Temp file created in an optical impression system, 3D printer, and curing light equipment.

    Digital Temp resin is designed to meet appropriate ISO standards for flexibility and sorption, to withstand prolonged use in the oral cavity. It is delivered nonsterile, and instructions on curing, and cleaning the final device prior to providing it to a patient are provided in the device indication for use document.

    AI/ML Overview

    The provided text is a 510(k) summary for SprintRay Digital Temp, a light-curable resin used for fabricating temporary dental restorations. It does not contain information on acceptance criteria or studies proving that a device meets such criteria for an AI/ML-based medical device.

    Instead, it focuses on the substantial equivalence of the Digital Temp resin to a predicate device based on:

    1. Intended Use/Indications for Use: Both are for temporary dental restorations.
    2. Technological Characteristics: Both are light-cured acrylate resins used with 3D printers and scanned 3D images.
    3. Performance Data: Biocompatibility testing and bench testing based on ISO 10477 were performed, and the resin "functioned as intended."

    Therefore, I cannot extract the requested information about acceptance criteria and the study proving an AI/ML device's performance, as the document describes a material (resin) and not an AI/ML algorithm.

    The questions you've asked (e.g., sample size for test/training sets, expert ground truth establishment, MRMC studies) are highly relevant to AI/ML device evaluations but are not addressed in this material-focused 510(k) summary.

    Ask a Question

    Ask a specific question about this device

    K Number
    K232559

    Validate with FDA (Live)

    Device Name
    C&B NFH Hybrid
    Date Cleared
    2024-09-11

    (385 days)

    Product Code
    Regulation Number
    872.3690
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Classification Name: Tooth shade resin material (21 CFR 872.3690), Crown and Bridge, Temporary, Resin (21 CFR 872.3770

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The C&B NFH Hybrid is indicated as an indirect restorative for both anterior and posterior restorations, including occlusal surfaces. The C&B NFH Hybrid material is used for fabricating temporary or permanent restorations such as crowns and bridges, inlays, onlays, veneers and full crown restoration of C&B NFH Hybrid requires a computer-aided and manufacturing (CAD/CAM) system that includes the following: scanner, design software, additive printer, and post-cure unit.

    Device Description

    The C&B NFH Hybrid is a light-cured, methacrylate oligomer based polymerizable resin used by dentist or dental technician for the CAD/CAM manufacturing of indirect restorative for both anterior and posterior restorations, including occlusal surfaces, such as temporary or permanent crowns and bridges, inlays, onlays and veneers. Methacrylate based resin is known materials, commonly used in the dental industry for fixed and removable prosthetic devices due to their physicalchemical, mechanical and biocompatible properties.

    AI/ML Overview

    This document is a 510(k) Premarket Notification from the FDA for a dental resin material named "C&B NFH Hybrid." It primarily focuses on demonstrating substantial equivalence to a predicate device, not on proving device performance against acceptance criteria in a clinical study involving experts or human readers with AI assistance.

    Therefore, many of the requested details about acceptance criteria and a study proving device meets them are not applicable in this context, as this document pertains to a material's physical and chemical properties and biocompatibility for substantial equivalence, rather than an AI-powered diagnostic device or a device requiring a multi-reader, multi-case study.

    However, I can extract the acceptance criteria and reported performance for the physical properties of the dental resin, which are relevant to its substantial equivalence.


    Acceptance Criteria and Reported Device Performance (Physical Properties of Dental Resin)

    Acceptance Criteria (Standard)Reported Device Performance (C&B NFH Hybrid)
    Flexural Strength (≥50 MPa; ISO 10477)Avg. 114.32 MPa
    Flexural Strength (≥100 MPa; ISO 4049)Avg. 114.32 MPa
    Water sorption (≤40 µg/mm³)Avg. 31.32 µg/mm³
    Solubility (≤7.5 µg/mm³)Avg. 5.59 µg/mm³

    Study Information (Based on the document provided):

    1. Sample size used for the test set and the data provenance: Not explicitly stated with specific numbers of samples for each test (e.g., how many specimens were tested for flexural strength). The data provenance is from non-clinical performance testing conducted by the manufacturer, ARUM DENTISTRY Co., Ltd., likely in a laboratory setting. This is not patient-specific or clinical data.

    2. Number of experts used to establish the ground truth for the test set and the qualifications of those experts: Not applicable. For physical property testing of a material, "ground truth" is typically established by standardized testing methods and measurements, not by expert interpretation in the medical sense.

    3. Adjudication method for the test set: Not applicable. Standardized laboratory testing methods do not involve adjudication in the way clinical studies with human observers do.

    4. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance: Not applicable. This device is a dental material, not an AI-powered diagnostic tool.

    5. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done: Not applicable. This device is a dental material, not an algorithm.

    6. The type of ground truth used: Standardized laboratory measurements according to ISO 10477:2020 and ISO 4049:2013 for physical properties (flexural strength, water sorption, solubility). For biocompatibility, compliance was shown with ISO 7405, ISO 10993-1, -5, -10, -11, -12, and -23.

    7. The sample size for the training set: Not applicable. This is not an AI/machine learning device that requires training data.

    8. How the ground truth for the training set was established: Not applicable.


    Summary of the "Study" (Non-Clinical Performance Data) from the document:

    The device did not undergo a "study" in the clinical sense with human readers or AI. Instead, the manufacturer provided Non-Clinical Performance Data to support the substantial equivalence determination for the "C&B NFH Hybrid" dental resin.

    The data presented focuses on:

    • Physical Property Testing: The device was tested for flexural strength, water sorption, and solubility. The reported values demonstrate that the device meets or exceeds the requirements set by the international standards ISO 10477:2020 ("Dentistry - Polymer-based crown and veneering materials") and ISO 4049:2013 ("Dentistry - Polymer-based restorative materials").
    • Biocompatibility: The C&B NFH Hybrid material (Dimethacrylate based resins) was shown to be compliant with a series of ISO 10993 and ISO 7405 standards for biocompatibility (e.g., cytotoxicity, irritation, sensitization, systemic toxicity).
    • Shelf-Life: Accelerated aging tests in accordance with ASTM F1980 validated a 2-year shelf-life.

    The purpose of these tests was to demonstrate that the C&B NFH Hybrid has similar safety and effectiveness characteristics to its predicate device (K202846, TERA HARZ by Graphy Inc.) and meets established performance standards for dental materials. The conclusion is that the subject device is substantially equivalent to the predicate device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K241071

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2024-09-04

    (138 days)

    Product Code
    Regulation Number
    872.3760
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    |
    | Classification Regulation | 21 CFR 872.376021 CFR 872.3770

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    NextDent Jet Denture Base is a light curing resin intended for 3D printing of a full or partial denture base to form a denture. The product, when used in combination with NextDent Jet Denture Teeth can be used for 3D printing a removable full or partial denture. For dental professional use only.

    NextDent Jet Denture Teeth is a light curing resin intended for the 3D printing of artificial teeth to form a denture, temporary crowns or bridges. The product, when used in combination with NextDent Jet Denture Base can be used for 3D printing a removeable full or partial denture. For dental professional use only.

    Device Description

    NextDent Jet Denture resins are pre-mixed combinations of acrylate-based light-cure resins with pigments, polymerized via photo initiators in a 3D printer setting for the fabrication of full or partial denture bases and artificial teeth to form a denture and for the fabrication of temporary crowns or bridges. The resins must be used in combination with 3D Systems printers that support MultiJet Printing technology. Devices are produced in an automated additive manufacturing method where ultra-thin layers of photopolymer material are jetted onto a build tray. Immediately after being jetted, each photopolymer layer is cured by UV light. The process repeats layer by layer until the 3D part is complete. Upon completion the support material is removed, and the product is cleaned. When printing a denture base, bonding of artificial teeth to the denture base is possible to form a denture. The bonding agent instructions should be followed. Printed parts are finished using conventional dental methods and instruments.

    AI/ML Overview

    The provided text is a 510(k) Premarket Notification from the FDA for "NextDent Jet Denture Base" and "NextDent Jet Denture Teeth". It describes the device, its intended use, and a summary of testing conducted to demonstrate substantial equivalence to predicate devices.

    However, the provided text does not contain information related to an AI/ML device. Specifically, there is no mention of acceptance criteria for an AI algorithm, test set details, expert involvement in ground truth establishment, MRMC studies, or training set information. The testing described focuses on the mechanical and biocompatibility properties of the dental resins, adhering to ISO standards for dental materials.

    Therefore, I cannot provide an answer that describes the acceptance criteria and the study proving an AI/ML device meets them based on the provided text. The questions posed in your prompt (e.g., sample sizes for test sets, number of experts, adjudication methods, MRMC studies, standalone performance, ground truth types for AI, training set details) are relevant to AI/ML device evaluations but are not addressed in this document, as it pertains to a materials-based medical device.