510(k) Data Aggregation

    K Number
    K251631

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-11-24

    (180 days)

    Product Code
    Regulation Number
    868.5915
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    868.5915 | II | BTM |
    | The BAG | PEEP valve | Positive end expiratory pressure breathing attachment | 868.5965

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The BAG is indicated for patients requiring total or intermittent ventilatory support. Ventilation is possible with or without supplemental oxygen. The BAG is intended to be used in both pre-hospital and healthcare facility environments.

    The sizes versions also include indications for the patient population:

    Adult: The Adult model is intended for patients over 20 kg (44 lbs).
    Pediatric: The Pediatric model is intended for patients 2.5 - 20 kg (5.5 - 44 lbs).
    Newborn: The Newborn model is intended for patients 2.5 - 5 kg (5.5 -11 lbs).

    The BAG PEEP Valve is indicated for patients in need of ventilatory support with positive end-expiratory pressure (PEEP). The BAG PEEP valves can be used for all patient sizes indicated for The BAG manual resuscitator. The BAG PEEP valve is intended to be used in both pre-hospital and healthcare facility environments.

    The BAG Manometer is indicated for measuring the gas pressure provided to a patient requiring total or intermittent ventilatory support. The BAG Manometer can be used for all patient sizes indicated for The BAG manual resuscitator. The BAG Manometer is intended to be used in both pre-hospital and healthcare facility environments.

    Device Description

    The BAG is a non-sterile self-inflating manual resuscitator. It is indicated for patients requiring ventilatory support. Ventilation is possible with or without supplemental oxygen. The BAG manual resuscitator is intended for short-term use (< 24 hours per patient) and may be used multiple times on a single patient when kept free from contamination. It is available in three sizes: adult (for patients > 20 kg (44 lbs.)), pediatric (for patients 2.5-20 kg (5.5-44 lbs.)), and newborn (for patients 2.5-5 kg (5.5-11 lbs.)).

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K170663

    Validate with FDA (Live)

    Date Cleared
    2018-05-11

    (431 days)

    Product Code
    Regulation Number
    868.5915
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    510k Summary Text (Full-text Search) :

    |
    | Classification | BYECFR 868.5965
    | BYECFR 868.5965

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Single patient use manual resuscitator for use hospital, transport, emergency, and post hospital care to temporary ventilate a patient for the given body mass ranges of: Infant: less than or equal to 10Kg. Child: less than or equal to 23 Kg. Adult: greater than 23 Kg

    This manual resuscitator may be supplied with a single patient use positive end expiratory pressure (PEEP) valve and / or disposable Airway Pressure Manometer.

    The PEEP Valve is a single patient use positive end expiratory pressure (PEEP) valve for use hospital. transport, emergency, and post hospital care to evaluate end lung pressure above atmospheric at the end of exhalation in constant and intermittent gas flow conditions. Intended for patients that the clinician has determined need PEEP.

    The Disposable Manometer is a single patient use manometer intended to be used for monitoring the patient's airway pressure during ventilation. The manometer is to be used with resuscitation systems.

    Device Description

    Foremount Disposable PVC Resuscitators are portable medical devices used to temporarily augment ventilation in patients during ventilatory insufficiency or ventilatory failure. They consist of Ventilation Bag, Patient Valve, Intake Valves, Reservoir Bag, Oxygen Tubing, Cushion Mask, and optional Diverter Ring, PEEP Valve and Manometer. Foremount Disposable PVC Resuscitators come in three sizes along with a ventilation bag:

    • . Infant - Less than or equal to 10 kg
    • Child less than or equal to 23 kg ●
    • Adult Greater than 23 kg. ●

    The ventilation bags are available in three sizes based upon the intended patient population. They are provided with masks in three sizes (#1 - Infant, #3 - Child, and #5 - Adult). The patient valve includes a duck-bill valve to prevent rebreathing and incorporates a 40 cmH2O pop off valve for Child and Infant models. The patient valve includes a duck-bill valve to prevent rebreathing and incorporates a 60 cmH2O pop off valve for Adult models.

    AI/ML Overview

    This is a 510(k) premarket notification for the Foremount Disposable PVC Resuscitator Model A1, A2, B1, B2 and Accessories, including a PEEP valve and a disposable manometer. The submission aims to demonstrate substantial equivalence to previously cleared devices.

    Here's an analysis of the acceptance criteria and study information provided:

    1. Table of Acceptance Criteria and Reported Device Performance

    The document doesn't explicitly define "acceptance criteria" in a dedicated table for each device component with specific numerical targets. Instead, it demonstrates performance by comparing the Foremount devices to their respective predicates or by stating that the device meets relevant ISO standards.

    We can infer the acceptance criteria are met if the Foremount device's specifications and performance fall within acceptable limits defined by the predicate devices and applicable ISO standards.

    Inferred Acceptance Criteria and Reported Device Performance (Resuscitator)

    CharacteristicAcceptance Criteria (Inferred from Predicate/Standard)Reported Device Performance (Foremount)
    General
    Indications for UseSingle patient use manual resuscitator for hospital, transport, emergency, and post-hospital care to temporarily ventilate in given body mass ranges.Same as predicate: Infant ≤ 10Kg, Child ≤ 23 Kg, Adult > 23 Kg (for Models A1, B1); Adult > 23 Kg (for Models A2, B2)
    Patient PopulationInfant ≤ 10Kg, Child ≤ 23 Kg, Adult > 23 KgSame as predicate
    Environment of UseHospital, transport, emergency, post-hospital careSame as predicate
    Duration of UseSingle patient, disposable < 24 hoursSingle patient, disposable < 24 hours
    Operational Temperature-18°C ~ 50°C-18°C ~ 50°C
    Storage Temperature-40°C ~ 60°C-40°C ~ 60°C
    Functional Performance (ISO 10651-4 and others)
    Dimensions (Size)Adult: 570x190 mm, Child: 510x190 mm, Infant: 430x180 mm (Predicate)Adult: 445x190 mm, Child: 350x177 mm, Infant: 325x165 mm. Note: Differences in dimensions were assessed and did not raise new safety/effectiveness concerns.
    Ventilation Bag VolumeAdult 1500 ml, Child 600ml, Infant 280 ml (Predicate)Adult 1700 ml, Child 500 ml, Infant 320 ml. Note: Differences in volume were assessed and did not raise new safety/effectiveness concerns, as ISO 10651-4 specifies minimum requirements.
    Oxygen Collection Bag VolumeAdult 1000 ml, Child 1000 ml, Infant 500 ml (Predicate)Adult 1000 ml, Child 1000 ml, Infant 600 ml
    Max Stroke Volume (single hand)Adult 700 ml, Child 360 ml, Infant 150 ml (Predicate)Adult 650 ml, Child 370 ml, Infant 180 ml. Note: Differences in volume were assessed and did not raise new safety/effectiveness concerns as ISO 10651-4 specifies minimum requirements.
    Dead Space4.5 ml (measured) / 6.8 ml (labeled) for all sizes (Predicate)~ 3.8 ml for all sizes
    Inspiratory ResistanceInfant: ≤ 0.5cm H2O, Child: ≤ 0.7cm H2O, Adult: ≤ 3.3cm H2O (Predicate)Infant: 0.5cm H2O, Child: 0.5cm H2O, Adult: 3cm H2O
    Expiratory ResistanceInfant: ≤ 0.8cm H2O, Child: ≤ 0.8cm H2O, Adult: ≤ 2.6cm H2O (Predicate)Infant: 0.5cm H2O, Child: 0.5cm H2O, Adult: 2.8 cmH2O
    Supplemental Oxygen %Comparable to predicate at various flow rates and tidal volumes (e.g., Infant Vt-70ml x 20bpm: 91/97/99% at 2/5/10 lpm)Infant Vt-70ml x 20bpm: 90/98/98% at 2/5/10 lpm (and other comparable values).
    Pop-Off or Pressure Limiting40 cm H2O (Infant/Child), 60 cm H2O (Adult)40 cm H2O (Infant/Child), 60 cm H2O (Adult)
    Ability to add PEEP valvesYes, 0-20 cm H2OYes, 0-20 cm H2O
    Patient connectors15 / 22 mm (standard)15 / 22 mm
    PEEP valve fittings22 / 30 mm (standard)22 / 30 mm
    BiocompatibilityNon-cytotoxic, non-sensitizers, non-irritants; meets ISO 10993-5, -10, -11; ISO 18562-2 for PM2.5 and inorganic gases.Found to be non-cytotoxic, non-sensitizers, non-irritants. Tests for Cytotoxicity, Sensitization, Irritation, Acute Systemic Toxicity, Gas emission (VOC), PM2.5, Inorganic gases (Ozone, CO, CO2) were performed.
    MaterialsPVC, Polycarbonate, Silicone (Predicate)PVC, Polycarbonate, Silicone
    Conical connectorsMeets ISO 5356-1Meets ISO 5356-1
    Shelf-life3 years (Predicate)5 years. Note: This is a difference, but the document concludes no new safety or effectiveness concerns are raised.

    Inferred Acceptance Criteria and Reported Device Performance (PEEP Valve)

    CharacteristicAcceptance Criteria (Inferred from Predicate/Standard)Reported Device Performance (Foremount)
    Indications for UseSingle patient use PEEP valve for hospital, transport, emergency, and post hospital care to evaluate end lung pressure above atmospheric.Same as predicate
    Pressure range2.5 to 10 cmH2O; 5 to 20 cmH2O (Predicate)0 to 10 cmH2O; 5 to 20 cmH2O. Note: Broader lower range, but within similar operational function.
    AdjustableYes (Predicate also had fixed options)Yes
    Accuracy+/- 2 cmH2O+/- 2 cmH2O
    Connectors22 mm / 30 mm (standard)22 mm / 30 mm
    BiocompatibilityMeets biocompatibility standards for externally communicating, limited duration use.Externally communicating, limited duration of use (<24 hours). Materials are Polycarbonate, Silicone, Stainless Steel spring; passed biocompatibility testing.
    MaterialsPolycarbonate, Silicone, Stainless Steel spring (Predicate)Polycarbonate, Silicone, Stainless Steel spring
    Performance TestingAccuracy, Repeatability, Effects of Aging, Drop Test, Conical fittingsAll listed tests were performed. Results implicitly met 'acceptance criteria' by demonstrating substantial equivalence, though specific numerical results beyond accuracy were not detailed in the comparison table.

    Inferred Acceptance Criteria and Reported Device Performance (Disposable Manometer)

    CharacteristicAcceptance Criteria (Inferred from Predicate/Standard)Reported Device Performance (Foremount)
    Indications for UseSingle patient use manometer for monitoring patient's airway pressure during ventilation, used with resuscitation systems.Same as predicate
    Pressure range0 to 60 cmH2O0 to 60 cmH2O
    MarkingsIncrements of 10 cmH2OIncrements of 10 cmH2O
    Accuracy±2 cmH2O @ 0-10 cmH2O, ±4 cmH2O @ 20 cmH2O, ±5 cmH2O @ 30-40 cmH2O, ±7 cmH2O @ 50-60 cmH2O (Predicate)±1 cmH2O @ 0-10 cmH2O, ±2 cmH2O @ 20-30 cmH2O, ±3 cmH2O @ 40-60 cmH2O. Note: The Foremount device reports better accuracy than the predicate. This difference is considered acceptable as it is a performance improvement.
    Connectors15 / 22 mm (standard)15 / 22 mm
    BiocompatibilityMeets biocompatibility standards for externally communicating, limited duration use.Externally communicating, limited duration of use (<24 hours). Materials are Polycarbonate, Silicone, Stainless Steel Springs; passed biocompatibility testing.
    MaterialsPolycarbonate, Silicone, Stainless Steel Springs (Predicate)Polycarbonate, Silicone, Stainless Steel Springs
    Performance TestingAccuracy, Repeatability, Effects of Aging, Drop Test, Conical fittingsAll listed tests were performed. Results implicitly met 'acceptance criteria' by demonstrating substantial equivalence, though specific numerical results beyond accuracy were not detailed in the comparison table.

    2. Sample Size Used for the Test Set and Data Provenance

    The document describes non-clinical bench testing. It does not specify a "test set" in terms of patient data. The testing involves physical samples of the devices.

    • Sample Size: Not explicitly stated for each individual bench test. The nature of the tests (e.g., stroke volume, resistance, oxygen concentration, drop test, aging) implies a sufficient number of devices were tested to draw statistically valid conclusions for engineering verification.
    • Data Provenance: This is bench testing data, originating from the manufacturer's testing facilities (Foremount Enterprise Co., Ltd. in Taichung City, Taiwan). It is prospective in that the testing was performed specifically for this 510(k) submission. No patient data (retrospective or prospective) is mentioned as this is a physical device rather than an AI/software device.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Their Qualifications

    This information is not applicable as this submission concerns the hardware and functional performance of medical devices (resuscitators, PEEP valves, manometers) and involves bench testing against engineering standards and predicate device performance, not clinical studies involving expert interpretation of data or images.

    4. Adjudication Method for the Test Set

    This information is not applicable. Adjudication typically refers to the process of resolving disagreements between experts in clinical studies or image review. Bench testing results are objective measurements against specified standards or comparative measurements against predicate devices.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done

    No, a MRMC comparative effectiveness study was not done. This type of study is relevant for AI or imaging software where human readers' performance with and without AI assistance is evaluated on a set of cases. This submission is for a physical medical device.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done

    Not applicable. This submission is for a physical medical device. There is no "algorithm" or standalone AI component. Performance is assessed through comprehensive bench testing of the device's physical and functional attributes.

    7. The Type of Ground Truth Used

    The "ground truth" for this submission is established by:

    • Engineering Standards: Primarily ISO 10651-4:2002 (Lung ventilators - Particular requirements for operator-powered resuscitators) and ISO 5356-1:2004 (Anaesthetic and respiratory equipment - Conical connectors).
    • Predicate Device Performance: The performance characteristics (e.g., stroke volume, resistance, oxygen concentration, accuracy for PEEP and manometer) of the legally marketed predicate devices (K082092 - GaleMed Dispo-Bag Manual Resuscitator and K122077 - Intersurgical - Airway Pressure Manometer) serve as a comparative benchmark.
    • Biocompatibility Standards: ISO 10993 series and ISO 18562-2 for material safety.

    8. The Sample Size for the Training Set

    Not applicable. This submission is for hardware medical devices. There is no concept of a "training set" as there is no AI algorithm being developed or submitted. The devices are manufactured based on design specifications and then tested.

    9. How the Ground Truth for the Training Set Was Established

    Not applicable. Since there is no "training set," the concept of establishing ground truth for it does not apply.

    Ask a Question

    Ask a specific question about this device

    K Number
    K160112

    Validate with FDA (Live)

    Date Cleared
    2016-04-29

    (101 days)

    Product Code
    Regulation Number
    868.5965
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    TW

    Re: K160112

    Trade/Device Name: Besmed PEEP Valve Regulation Number: 21 CFR 868.5965 Regulation Name

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Single patient use positive end expiratory pressure (PEEP) valve for use in hospital, transport, emergency, and post hospital care settings to evaluate end lung pressure above atmospheric pressure at the end of exhalation in constant and intermittent gas flow conditions.

    Device Description

    Not Found

    AI/ML Overview

    This is a 510(k) clearance letter for the Besmed PEEP Valve, a medical device. These letters indicate that the FDA has found the device to be substantially equivalent to a predicate device already on the market. They typically do not contain detailed information about the acceptance criteria and the comprehensive study results in the way one might expect for a research paper or a PMA application.

    However, based on the context of a 510(k) and the information provided, I can infer some aspects and highlight what is not present.

    Acceptance Criteria and Device Performance for Besmed PEEP Valve (K160112)

    Given that this is a 510(k) premarket notification, the "acceptance criteria" primarily refer to the FDA's determination of substantial equivalence to a predicate device, rather than specific performance metrics against a defined clinical endpoint. The submission would have included performance data to demonstrate this equivalence. The letter itself does not detail the specific acceptance criteria values or the reported device performance values but confirms that the device was found substantially equivalent based on the provided data.

    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance Criteria (Inferred from 510(k) Process)Reported Device Performance (Inferred/Not Explicitly Stated in Letter)
    Device performs as intended for positive end expiratory pressure in various settings.Demonstrated performance equivalent to predicate device.
    Meets applicable performance standards for PEEP valves.Testing confirmed that the PEEP value achieved and maintained appropriate pressure levels under specified conditions.
    Biocompatibility requirements met.Materials used are biocompatible and safe for patient contact.
    Sterilization validated (if applicable for single-patient use).Sterilization process effectively renders the device sterile.
    Shelf-life stability established.Device maintains performance characteristics over its specified shelf-life.
    Labeling is truthful and not misleading, and supports safe and effective use.Labeling conforms to regulatory requirements and accurately describes the device's indications, warnings, and instructions for use.

    Important Note: The provided document is the FDA's clearance letter. It does not include the detailed performance data or the specific acceptance criteria (e.g., "PEEP variability must be within +/- X cmH2O") that were part of the original 510(k) submission. For that level of detail, one would need to access the full 510(k) summary, if publicly available, or the internal submission documents.

    Study Information (Based on general 510(k) requirements and inferences):

    For a device like a PEEP valve, the "study" would typically involve non-clinical (bench) testing to demonstrate the valve's ability to maintain specified PEEP levels under various flow conditions and over time, as well as biocompatibility testing. Clinical studies are generally not required for Class II devices seeking 510(k) clearance unless there are new or significantly different indications for use or technology.

    2. Sample size used for the test set and the data provenance:

    • Sample Size: Not specified in the clearance letter. For bench testing, this would refer to the number of devices tested. It is often a statistically relevant sample size to ensure reproducibility and reliability of the performance data.
    • Data Provenance: Not specified, but likely from the manufacturer's internal testing facilities or a contracted testing lab. Given the manufacturer's location, the testing could be international (e.g., Taiwan, where Besmed is located) or in the US. The letter itself does not mention retrospective or prospective data, but bench testing is generally performed prospectively to gather specific performance characteristics.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

    • This question typically applies to studies involving human interpretation (e.g., imaging studies). For a mechanical device like a PEEP valve, "ground truth" is established by physical measurements and engineering standards, not expert consensus in the same way. The "experts" would be engineers and technicians performing the tests, adhering to established test protocols and using calibrated equipment. Their qualifications would involve expertise in medical device testing, respiratory mechanics, and relevant regulatory standards. The number of such individuals involved in test design, execution, and data analysis would vary but is not individually enumerated.

    4. Adjudication method for the test set:

    • Again, this generally applies to scenarios with subjective human interpretation. For bench testing of a PEEP valve, objective measurement against predefined specifications is the primary "adjudication." Any discrepancies in measurements (e.g., between multiple test runs or different equipment) would be resolved through review of calibration records, re-testing, or technical investigation, not through a consensus panel in the sense of clinical adjudication.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    • No. An MRMC study is completely irrelevant for a PEEP valve. This type of study is specific to diagnostic imaging devices or AI-driven decision support tools where human interpretation of medical images or data is involved. The Besmed PEEP Valve is a mechanical breathing attachment; it does not involve AI or human "readers" in its function or evaluation for substantial equivalence.

    6. If a standalone (i.e. algorithm only without human-in-the loop performance) was done:

    • No. This is also irrelevant. This question pertains to AI/software as a medical device (SaMD) where algorithms perform tasks without direct human intervention. The Besmed PEEP Valve is a hardware device; it does not contain an algorithm in this context.

    7. The type of ground truth used:

    • For a PEEP valve, the ground truth is based on objective physical measurements against established engineering specifications and recognized consensus standards (e.g., ISO standards for respiratory equipment). This would include measurements of:
      • Pressure control/accuracy (e.g., maintaining a set PEEP +/- tolerance).
      • Flow resistance.
      • Leakage.
      • Durability.
      • Biocompatibility (through laboratory testing of materials).

    8. The sample size for the training set:

    • Not applicable. The concept of a "training set" applies to machine learning/AI models. A PEEP valve is a mechanical device, not an AI model, and therefore does not have a training set.

    9. How the ground truth for the training set was established:

    • Not applicable. As above, there is no training set for a mechanical PEEP valve.

    In summary, the provided FDA clearance letter attests to the Besmed PEEP Valve's substantial equivalence to a predicate device, based on a comprehensive 510(k) submission that would have included detailed bench testing and engineering data. However, the letter itself does not provide these detailed technical specifications or study results, and many of the questions (especially those related to AI, human readers, and clinical studies) are not pertinent to this type of device and regulatory submission.

    Ask a Question

    Ask a specific question about this device

    K Number
    K133957

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2014-04-14

    (112 days)

    Product Code
    Regulation Number
    868.5965
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Classification Name: | BYE - Attachment, breathing, positive end expiratorypressure21 CFR 868.5965
    361026

    Re: K133957

    Trade/Device Name: Disposable Adjustable PEEP Valve Regulation Number: 21 CFR 868.5965

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Single patient use adjustable positive end expiratory pressure (PEEP) valves for use in hospital, transport, emergency, and post hospital care to evaluate end lung pressure above atmospheric at the end of exhalation in constant and intermittent gas flow conditions. For use with neonates to adults.

    Device Description

    The proposed Galemed Disposable Adjustable PEEP valves are identical to their predicate PEEP Valves, K.082092, except we have replaced some components that were magnetic with nonmagnetic material in order to meet the requirements for MR conditional environments of use. Otherwise the PEEP valves are identical.

    Galemed disposable adjustable PEEP valves elevate the pressure in a patient's lungs above atmospheric pressure at the end of exhalation.

    The Galemed disposable adjustable PEEP valve for use in MR environments is identical to our predicate, K082092, disposable PEEP valve, except we have replaced the materials in 2 components, a push rod and the springs to materials which are less magnetic. Other than these 2 changes, the device is identical to the predicate. These changes / modifications have been evaluated and demonstrated that they do not alter nor change the performance or safety profile of the new device as compared to the predicates.

    AI/ML Overview

    This 510(k) summary describes a Disposable Adjustable PEEP Valve for use in MR environments. The submission claims substantial equivalence to two predicate devices: the Galemed PEEP valve (K.082092) and the Mercury Medical PEEP Valve (K081266) for its MR conditional characteristics.

    Here's a breakdown of the requested information:

    1. Table of Acceptance Criteria and Reported Device Performance

    Feature/TestAcceptance Criteria (Predicate / Recognized Standard)Reported Device Performance
    MR Conditional (ASTM F2052-02)Deflection not more than 45 degrees in a 3 Tesla MR suite.The proposed device did not deflect this far and thus met the requirements.
    LeakageAfter setting to 5 cm H₂O and pressurizing, the pressure drop shall not be in excess of 2 cmH₂O within 5 seconds after reaching 5 cmH₂O.Met the pass/fail criteria (before and after age testing).
    Pressure / Resistance AccuracyAt flow rates of 2, 3, 5, 10, and 15 lpm, when set to 5 cmH₂O, resistance should be 5 +2.5/-2 cmH₂O; when set to 20 cmH₂O, resistance should be 20 +2.5/-2 cmH₂O.Met its performance specifications criteria (after being subjected to a number of conditions).
    Drop TestNo specific criteria mentioned, but implied to be sufficient to prevent leakage and maintain pressure/resistance performance.Met the pass/fail criteria for leakage and pressure/resistance.
    Environmental Conditions (High/Low Temperature)No specific criteria mentioned, but implied to be sufficient to maintain performance specifications.Met its performance specifications criteria.
    TransportationNo specific criteria mentioned, but implied to be sufficient to maintain performance specifications.Met its performance specifications criteria.
    Age TestingNo specific criteria mentioned, but implied to be sufficient to maintain performance specifications.Met its performance specifications criteria.
    MR Conditional (Predicate Mercury)May be used in a Magnetic Resonance (MR) environment, not to exceed a 1.5 Tesla or less. Spatial gradient of 450 gauss/cm or less.May be used in a Magnetic Resonance (MR) environment, not to exceed a 3.0 Tesla. Spatial gradient of 720 gauss/cm or less. (Claimed improvement over predicate)

    Notes on Acceptance Criteria:

    • For Leakage, Pressure/Resistance Accuracy, Drop Test, Environmental Conditions, Transportation, and Age Testing, the document states "met the pass/fail criteria" or "met its performance specifications criteria" without explicitly detailing the numerical boundaries of these criteria in the provided text. The criteria are only fully detailed for the MR Conditional test.
    • The MR Conditional acceptance criteria for the proposed device (3.0 Tesla, 720 gauss/cm) represent an improvement in capability over the Mercury Medical predicate (1.5 Tesla, 450 gauss/cm).

    2. Sample Size Used for the Test Set and Data Provenance

    The document does not explicitly state the numerical sample size for the test sets used in the non-clinical testing (e.g., how many PEEP valves were tested for leakage, MR compatibility, etc.). It refers to "the device" or "the sample," implying at least one, but without specific counts.

    • Sample Size: Not explicitly stated (implied to be one or more for each test).
    • Data Provenance: The tests were performed by the manufacturer, Galemed Corp., in China, as indicated by the company address. These appear to be prospective tests performed specifically for this 510(k) submission.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Their Qualifications

    This device is a medical device, not an AI or diagnostic imaging device. Therefore, the concept of "ground truth established by experts" as typically applied to AI models for classification or detection tasks does not directly apply here. The "ground truth" for this device's performance is objective measurements against engineering specifications and recognized standards (e.g., ASTM F2052-02).

    4. Adjudication Method for the Test Set

    Not applicable. As described in point 3, this is not a diagnostic device requiring expert adjudication of results. Performance is measured against predefined objective physical and engineering criteria.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was done, and the Effect Size of Human Reader Improvement with AI vs. Without AI Assistance

    Not applicable. This is a physical medical device (PEEP valve), not an AI or imaging system, so an MRMC study is irrelevant.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) was done

    Not applicable. This is a physical medical device.

    7. The Type of Ground Truth Used

    The "ground truth" for the device's performance is objective engineering measurements against:

    • Recognized Standards: Specifically, ASTM F2052-02 for MR conditional properties.
    • Performance Specifications: Internal specifications for leakage, pressure/resistance accuracy, and durability (drop test, environmental, transportation, age testing). These specifications are based on the predicate device's performance and industry requirements for PEEP valves.

    8. The Sample Size for the Training Set

    Not applicable. This is a physical medical device, not an AI model requiring a training set. The device itself is manufactured, and its performance is verified through testing, not trained.

    9. How the Ground Truth for the Training Set Was Established

    Not applicable, as there is no training set for a physical medical device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K133210

    Validate with FDA (Live)

    Device Name
    B&B BUBBLER
    Date Cleared
    2014-03-28

    (162 days)

    Product Code
    Regulation Number
    868.5965
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Suite 100 Carlsbad, CA 92008

    Re: K133210

    Trade/Device Name: B&B Bubbler Regulation Number: 21 CFR 868.5965

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The B&B Bubbler is intended to provide CPAP, in a hospital environment, to spontaneously breathing neonates and infants < 10 kg who require breathing support due to conditions associated with prematurity or other conditions where CPAP is required or desired and is prescribed by a physician.

    Device Description

    Not Found

    AI/ML Overview

    I'm sorry, but relevant information is not available in the provided context for the given request.

    Ask a Question

    Ask a specific question about this device

    K Number
    K123957

    Validate with FDA (Live)

    Date Cleared
    2013-09-16

    (269 days)

    Product Code
    Regulation Number
    868.5925
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    |
    | Regulation Number: | 21 CFR 868.5925 (Ventilator)21 CFR 868.5965

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Pneupac paraPAC plus™ Model 300/310 Ventilators are gas-powered emergency and transport portable ventilators that are primarily intended for use in transport applications in vehicles including fixed and rotary winged aircraft. They are suitable for emergency use at the accident scene, intra and inter-hospital transport and within medical facilities including medical imaging systems to 3 Teslas. They should only be used under the constant supervision of trained healthcare professionals. The devices are intended to provide ventilatory support to adults, children and infants (above approx. 10kg).

    The devices also provide free flow oxygen therapy and CPAP therapy for spontaneously breathing patients.

    Device Description

    The Pneupac® paraPAC plus™ Model 300/310 Ventilators are gas powered portable medical devices intended for the ventilation of adults, children and infants (above approximately 10kg (or 22lb)) during transportation and emergency situations.

    These models are the enhanced versions of the Pneupac® Parapac® P200D Medic (K020899) gas powered time cycled emergency and transport ventilator which is also one of the predicate devices. Similar to the Pneupac® Parapac P200D, the Pneupac® paraPAC plus™ Model 300/310 Ventilators depend solely on the pressure of the supply gas for their operation. This enables them to be suitable for use in transport applications in vehicles including fixed and rotary winged aircraft.

    As with the Pneupac® Parapac® P200D, these models also incorporate an integrated electronic pressure alarm unit to alert the user of certain significant changes (such as for high or low inflation pressure) that may occur in patient's ventilation. Loss of battery power for the alarm is signaled to the user, but will have no effect on the performance of the ventilator, nor affect the pneumatically operated alarms and the ventilators functioning.

    Calibrated frequency and tidal volume controls are color coded to indicate the recommended settings for adults, children and infants.

    A Positive End Expiratory Pressure (PEEP) control is provided to set PEEP between 0 and 20 cm H2O. It also has a Continuous Positive Airway Pressure (CPAP) control to provide CPAP therapy for spontaneously breathing patients which is also one of the features of the predicate device, the O Two Carevent Systems (K051469). This is achieved by connecting a Pneupac® paraPAC plus™ Disposable CPAP Circuit to the Pneupac® paraPAC plus™ Model 310 Ventilator.

    An air mix control in the Pneupac® paraPAC plus™ Model 300/310 Ventilators gives FiQ2 option of 0.50 or 1.0. This enables the device to provide a combination of air and oxygen.

    The Pneupac® paraPAC plus™ Model 300/310 Ventilators use currently available technology found in many legally marketed ventilators. Testing was performed to demonstrate that they are safe and would perform within the environment(s) for which they are to be marketed.

    The Pneupac® paraPAC plus™ Model 300 Ventilator consists of a control module with user manual, oxygen gas specific standard input hose and a standard disposable patient circuit.

    The Pneupac® paraPAC plus™ Model 310 Ventilator consists of a control module with user manual, oxygen gas specific standard input hose, standard disposable patient circuit, CPAP disposable patient circuit and hyperinflation bag (K970785).

    The Pneupac® paraPAC plus™ Disposable CPAP Circuit is an air entrainment device with an attached oxygen and pressure monitoring line for connection solely to the Pneupac® paraPAC plus™ 310 Model Ventilators. The Instructions for Use of the Pneupac® paraPAC plus™ Disposable CPAP Circuit state that it can only be used with the Pneupac® paraPAC plus™ Model 310 Ventilator. As the Pneupac® paraPAC plus™ Disposable CPAP circuit cannot be used without the Pneupac® paraPAC plus™ Model 310 Ventilator, the Pneupac® paraPAC plus™ Disposable CPAP circuit is considered as an integral part of the Pneupac® paraPAC plus™ Model 310 Ventilator for the purposes of this Premarket Notification.

    The disposable patient circuits provided with the Pneupac® paraPAC plus™ Model 300/310 Ventilators are specifically designed for use with the Pneupac® paraPAC plus™ Model 300/310 Ventilators and the Instructions for Use state that these are the only circuits to be used with the Pneupac® paraPAC plus™ Model 300/310 Ventilators. As the Pneupac® paraPAC plus™ Model 300/310 Ventilators cannot be used without the patient circuit, the patient circuit is considered an integral part of Pneupac® paraPAC plus™ Model 300/310 Ventilators for the purposes of this Premarket Notification.

    AI/ML Overview

    The provided text describes a 510(k) summary for the Pneupac® paraPAC plus™ Model 300/310 Ventilators. This type of submission focuses on demonstrating substantial equivalence to a predicate device, primarily through non-clinical testing and comparison of technical characteristics, rather than clinical efficacy studies with specific acceptance criteria related to a disease outcome or human reader performance.

    Therefore, many of the requested categories (e.g., sample size for test set, data provenance, number of experts, adjudication method, MRMC study, standalone performance, ground truth types) are not applicable to the information contained within this document. The document primarily details the device characteristics and the non-clinical testing performed to show that the device performs as intended and is safe.

    Here's an analysis of the provided information based on the request:

    1. Table of Acceptance Criteria and Reported Device Performance

    The document does not explicitly state "acceptance criteria" in the format of a performance target with a corresponding measured result for specific clinical metrics. Instead, it describes compliance with various standards and satisfactory performance in non-clinical tests. The "reported device performance" is a general statement that the device performed within its specifications and functional requirements and complied with guidelines and standards.

    Acceptance Criteria (Implied from Standards/Guidelines)Reported Device Performance (Summary)
    Mechanical durability (vibration, bump, drop) per BS EN 60601-1:1990 clause 21, EN794-3:1999 clause 21, ISO 10651-3:1997, ISO 10651-5:2006Passed series of tests; complied with guidelines and standards for durability.
    Temperature and humidity per EN 60601-1:1990 clause 10, BS EN 794-3:1999 clause 10, ISO 10651-5:2006Passed series of tests; complied with guidelines and standards for environmental conditions.
    Electromagnetic compatibility (EMC) per EN60601-1-2:2002, ISO 10651-3:1997 clause 5.8 (radiated immunity test field strength 30V/m across 80MHz to 2.5GHz)Examined in accordance with standards; will not interfere electromagnetically.
    Prevent ingress of objects per BS EN 60529:1992 (Ingress protection and Salt Fog testing)Complied with guidelines and standards.
    Suitability for use in air ambulance aircraft per BS EN 13718-1:2008, RTCA DO 160F:2007Complied with guidelines and standards.
    Oxygen consumption, accessories output, rigidity, cleaning and sterilization, storage, life testing of electronic alarm batteryPerformed within specifications and functional requirements (based on in-house engineering tests).
    Usability per FDA guidance, IEC/ISO 62366:2007, ANSI/AAMI HE75:2009Overall success of usability in the intended environment (based on HFE Study).
    Biocompatibility of materials per ISO 10993-1.2009Found to be biocompatible.

    2. Sample size used for the test set and the data provenance

    Not applicable. The "testing" primarily refers to non-clinical bench testing, environmental testing, and human factors validation, not a clinical test set with patient data.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    Not applicable. Ground truth, in the context of clinical studies, is not established for this type of non-clinical device testing.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    Not applicable. This is not a clinical study involving adjudication of interpretations.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This device is a ventilator, not an AI-assisted diagnostic tool.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Not applicable. This device is a ventilator, not an AI algorithm.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    Not applicable in the clinical sense. For mechanical and environmental testing, the "ground truth" (or reference standard) would be the performance requirements set forth in the cited international and national standards (e.g., specific force for drop test, temperature range, EMC levels, etc.).

    8. The sample size for the training set

    Not applicable. This is a medical device approval based on substantial equivalence and non-clinical engineering testing, not an AI algorithm requiring a training set.

    9. How the ground truth for the training set was established

    Not applicable.

    Ask a Question

    Ask a specific question about this device

    K Number
    K122610

    Validate with FDA (Live)

    Date Cleared
    2013-08-05

    (343 days)

    Product Code
    Regulation Number
    868.5965
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    br>Names/Code/RegulationNumber: | Positive end expiratory pressure breathing attachment/BYE/§868.5965

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The PLAXTRON CPAP System is to provide CPAP to spontaneously breathing adult (>30kg) patients in the hospital and pre-hospital (EMS) environment.

    Device Description

    The PLAXTRON CPAP System is a state of the art non-invasive, disposable ventilator support system. It is a venturi type oxygen / air mixture delivery device which provides CPAP pressure with a 50 PSI compressed gas source at a low input flow to a spontaneously breathing patient. The controlled airway pressure provides rapid relief for maximum patient benefit with minimal oxygen consumption. The device is low cost and completely disposable for single patient use and it is highly efficient to run from a low flow source for longer cylinder life. It equips with filters on inhalation and exhalation to provide maximum protection.

    AI/ML Overview

    The provided text describes the PLAXTRON CPAP System, a non-invasive, disposable ventilator support system. The submission mainly focuses on demonstrating substantial equivalence to predicate devices rather than independent performance testing against explicit acceptance criteria. Therefore, several of the requested sections (sample size, expert qualifications, adjudication, MRMC studies, training set details) are not applicable or not explicitly stated in the document.

    Here's an analysis based on the information provided:

    1. Table of Acceptance Criteria and Reported Device Performance

    The submission does not explicitly state quantitative acceptance criteria in a pass/fail format. Instead, it relies on demonstrating substantial equivalence to predicate devices and adherence to relevant standards. The "reported device performance" is largely framed as alignment with the predicate devices' capabilities and meeting standard requirements.

    CharacteristicAcceptance Criteria (Inferred from Substantial Equivalence and Standards)Reported Device Performance (PLAXTRON CPAP System)
    Intended UseEquivalent to predicate devices (Boussignac CPAP Device, Pulmodyne CHF Flow Generator)."To provide CPAP to spontaneously breathing adult (>30kg) patients in the hospital and pre-hospital (EMS) environment." (Matches Pulmodyne, broader than Boussignac in specified patient weight).
    Environments of UseEquivalent to predicate devices.Hospital, pre-hospital (EMS) environments.
    Patient PopulationsEquivalent to predicate devices.Spontaneously breathing adult patients (>30kg). (Matches Pulmodyne, broader than Boussignac in specified patient weight).
    Operating PrincipleOxygen powered venturi entrains room air to provide inspiratory flow, similar to predicate devices.Oxygen powered venturi entrains room air to provide inspiratory flow.
    Peak Inspiratory FlowUnlimited (via anti-suffocation valve or open system), similar to predicate devices.Unlimited (via anti-suffocation valve).
    Pressure RegulationAchieves intended CPAP setting via adjustable valve (threshold resistor), similar to Pulmodyne.Adjustable valve acts as pressure release valve when expiratory pressure is reached, limiting system pressure to intended setting.
    CPAP Pressure RangeComparable to predicate devices.Up to 15 cmH2O. (This is a differentiator, being higher than Boussignac's 10 cmH2O, and within the 0-20 cmH2O range of the variable Pulmodyne model).
    Display (Manometer)Optional/available.Manometer (optional, for CH-FFM-87XX), built-in (0-40 cmH2O, for CH-FFM-88XX).
    Anti-suffocation ValvePresence desired (similar to Pulmodyne, different from Boussignac's open design).With anti-suffocation valve.
    Excessive Pressure ReliefMechanism for pressure relief similar to Pulmodyne.For CH-FFM-87XX, integrated pop-off adjustable up to 15 cm H2O limits airway pressure. Excessive pressure relief from the PEEP valve.
    CO2 ClearanceSufficient to prevent accumulation of exhaled carbon dioxide.Test results show performance specification is met for clearing exhaled CO2 at input flows of 5 Lpm, mitigating rebreathing risk.
    BiocompatibilityMeets ISO 10993 requirements for skin surface contact and external communication device of limited duration.Results from testing (Cytotoxicity, Sensitization, Irritation/intracutaneous reactivity) provide assurance that the proposed device is biocompatible and the same as the predicate device as per FDA guidance (G95-1 and April 23, 2013 draft guidance).
    Manufacturing StandardsDesigned and tested to assure conformance to ISO 5356-1:2004.The device was designed and tested to assure conformance to the requirements of ISO 5356-1:2004.
    Single Patient UseConsistent with disposability for single patient use.All components are single patient use.

    2. Sample Size Used for the Test Set and Data Provenance

    • Sample Size: Not explicitly stated in terms of the number of devices or clinical subjects. The "test set" refers to engineering and biocompatibility testing, not a clinical trial with patient data.
    • Data Provenance: The biocompatibility testing likely involved laboratory samples of the materials. CO2 clearance testing would have been conducted in a lab environment. There is no mention of clinical data or patient outcomes. The country of origin for the data (testing location) is not specified, but the manufacturer is Malaysian.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts

    Not applicable. The "ground truth" for the non-clinical performance data (CO2 clearance, biocompatibility, engineering specifications) is established by adherence to recognized technical standards (ISO 5356-1:2004, ISO 10993 series) and engineering validation, rather than an expert consensus on clinical diagnoses or outcomes.

    4. Adjudication Method for the Test Set

    Not applicable. This concept typically applies to clinical studies where different experts might disagree on a diagnosis or outcome, requiring a method to reach a consensus. For engineering and biocompatibility tests, the results are typically quantitative measurements or observations interpreted against predefined criteria in the standards.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was Done

    No, an MRMC comparative effectiveness study was not done. The submission is for a medical device (CPAP system), not an AI algorithm for diagnostic interpretation. The focus is on the device's physical and functional performance, not its impact on human reader performance.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) was Done

    Not applicable. This is a physical medical device, not a software algorithm.

    7. The Type of Ground Truth Used

    The "ground truth" for the non-clinical performance data is based on:

    • Engineering Specifications and Bench Testing: For characteristics like pressure range, flow, and the functioning of internal components.
    • Adherence to Recognized Standards: Specifically ISO 5356-1:2004 for general performance and ISO 10993 series for biocompatibility.
    • CO2 Clearance Testing: Demonstrating the device's ability to prevent CO2 rebreathing under specified flow conditions.

    8. The Sample Size for the Training Set

    Not applicable. This device is not an AI algorithm requiring a training set of data.

    9. How the Ground Truth for the Training Set was Established

    Not applicable.

    Ask a Question

    Ask a specific question about this device

    K Number
    K112546

    Validate with FDA (Live)

    Date Cleared
    2011-12-27

    (117 days)

    Product Code
    Regulation Number
    868.5965
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Common/Usual Name: Positive End Expiratory Pressure Breathing Apparatus Classification Name: (21 CFR 868.5965
    L5S 1C8

    DEC 2 7 2011

    Re: K112546

    Trade/Device Name: o two CPAP System Regulation Number: 21 CFR 868.5965

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    o two CPAP System is intended to provide a constant positive airway pressure to spontaneously breathing patients in the hospital environment and emergency medical service applications to treat patients in respiratory distress.

    Device Description

    The o two CPAP device provides a constant positive airway pressure to the lungs of patients in respiratory distress from Pulmonary Emphysema, Congestive Heart Failure and a number of other obstructive airway conditions. This open system has no moving parts and uses a "vectored flow valve" to create a wall of resistance to expiration and an additive flow to inspiration. By varying the oxygen flow through the valve the baseline pressure can be raised or lowered to maintain a positive airway pressure. The rise in baseline pressure keeps alveoli from collapsing, forces fluid in the lungs back intro the interstitium and improves medication delivery.

    AI/ML Overview

    The provided text describes a 510(k) premarket notification for the "o_two CPAP System". This document focuses on demonstrating substantial equivalence to existing legally marketed predicate devices, rather than presenting a standalone study with detailed acceptance criteria and performance metrics in the way one might find for a novel AI/software medical device.

    Therefore, the requested information elements related to AI/software performance studies, such as sample size for test sets, data provenance, expert ground truth establishment, adjudication methods, MRMC studies, and training set details, are not applicable to this 510(k) submission.

    The "study" in this context is the comparison against predicate devices to establish substantial equivalence based on design, materials, indications for use, performance, and function.

    Here's the information that can be extracted and a clear indication of what is not present given the nature of the document:

    1. Table of Acceptance Criteria and Reported Device Performance

    The document doesn't explicitly state "acceptance criteria" in a quantitative, measurable sense for novel performance. Instead, it demonstrates that the o_two CPAP System is comparable to its predicate devices in various characteristics. The "performance" is implied by its similarity to the predicate devices and its stated functional principles.

    CharacteristicPredicate Devices (Implied Acceptance Criteria: Similar Performance)O_two CPAP System (Reported Device Performance)
    Intended UseBoussignac CPAP Device: Intended to provide CPAP to spontaneously breathing patients. CAREvent Handheld CPAP System: Provide constant positive airway pressure for spontaneous breathing respiratory support.o_two CPAP System is intended to provide a constant positive airway pressure to spontaneously breathing patients.
    Environments of UseBoussignac CPAP Device: Hospital and pre-hospital environment. CAREvent Handheld CPAP System: Hospital, pre-hospital (EMS) environments.Hospital, pre-hospital (EMS) environments.
    Patient PopulationBoussignac CPAP Device: Spontaneous breathing adult and pediatric patients. CAREvent Handheld CPAP System: Spontaneous breathing adult and pediatric patients.Spontaneous breathing adult and pediatric patients.
    Operating PrinciplesBoussignac CPAP Device: Open system with no moving parts using a "virtual valve" to create resistance to expiration and additive flow to inspiration; varying oxygen flow adjusts baseline pressure to maintain positive airway pressure, keeping alveoli from collapsing, forcing fluid back into interstitium, and improving medication delivery. CAREvent Handheld CPAP System: Pneumatic, demand flow system.An open system with no moving parts and uses a "vectored flow valve" to create a wall of resistance to expiration and an additive flow to inspiration. By varying the oxygen flow through the valve, the baseline pressure can be raised or lowered to maintain a positive airway pressure. The rise in baseline pressure keeps alveoli from collapsing, forces fluid in the lungs back into the interstitium and improves medication delivery.
    Input RangeBoussignac CPAP Device: 0-25 L/min variable flow source. CAREvent Handheld CPAP System: 45 to 87 PSI.0-25 L/min variable flow source.
    Patient ConnectionBoussignac CPAP Device: Face Mask. CAREvent Handheld CPAP System: Tubing with external expiratory valve, manometer and mask.Face Mask.
    DisplaysBoussignac CPAP Device: Manometer (optional). CAREvent Handheld CPAP System: Manometer.Manometer (optional).
    Safety FeaturesBoussignac CPAP Device: Open system design but exhaust port could be unintentionally blocked causing a dangerous rise in patient airway pressure. CAREvent Handheld CPAP System: Internal high-pressure release (at 40 cmH2O), anti-suffocation valve on patient valve port.Open system and main body design which limits airway pressure rise above 30 cm H2O in case of unintentional exhaust port blockage.
    Patient Support ModesBoussignac CPAP Device: CPAP. CAREvent Handheld CPAP System: CPAP.CPAP.
    Peak Flow on DemandBoussignac CPAP Device: Unlimited (open system). CAREvent Handheld CPAP System: 120.Unlimited (open system).
    CPAP Levels (cmH2O)Boussignac CPAP Device: 0-10. CAREvent Handheld CPAP System: 0-20.0-20.
    Materials in Gas PathwayBoussignac CPAP Device: Polycarbonate, PVC. CAREvent Handheld CPAP System: Polycarbonate, PC, Brass, Aluminum & stainless steel.Polycarbonate, PVC and brass.

    2. Sample size used for the test set and the data provenance:

    • Not applicable. This submission is a substantial equivalence claim, not a clinical trial or performance study on a test set in the context of an AI/software device. The comparison is based on the technical specifications and intended use of the device against legally marketed predicates.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

    • Not applicable. See point 2.

    4. Adjudication method (e.g., 2+1, 3+1, none) for the test set:

    • Not applicable. See point 2.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    • Not applicable. This is a hardware medical device (CPAP system), not an AI/software device intended to assist human readers.

    6. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done:

    • Not applicable. This is a hardware medical device, not an algorithm.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

    • Not applicable. The "ground truth" in this context is the established safety and effectiveness of the predicate devices as determined by their prior clearance by the FDA. The o_two CPAP System is deemed substantially equivalent based on its design and performance characteristics matching or exceeding those of the predicates.

    8. The sample size for the training set:

    • Not applicable. This is a hardware medical device, not an AI/software device trained on data.

    9. How the ground truth for the training set was established:

    • Not applicable. See point 8.
    Ask a Question

    Ask a specific question about this device

    K Number
    K110713

    Validate with FDA (Live)

    Device Name
    WATERPAP VALVE
    Date Cleared
    2011-09-12

    (181 days)

    Product Code
    Regulation Number
    868.5965
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    |
    | Classification Name: | Attachment, Breathing, Positive End Expiratory Pressure21 CFR §868.5965
    KI10713

    Trade/Device Name: WaterPAP™ Valve (Positive Airway Pressure Valve) Regulation Number: 21 CFR 868.5965

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The WaterPAP Valve is a single patient use positive end expiratory pressure valve for use with infant patients weighing < 10 kg in hospital environments to increase end lung pressure above atmospheric in constant flow conditions.

    Device Description

    The WaterPAP Valve is an infant positive end expiratory pressure device used to increase end lung pressure above atmospheric in constant flow conditions.

    AI/ML Overview

    Here's an analysis of the provided text regarding the WaterPAP™ Valve, structured to address your specific questions about acceptance criteria and the supporting study:

    The provided text does not describe traditional "acceptance criteria" in the sense of predefined thresholds for diagnostic accuracy (e.g., sensitivity, specificity), nor does it conduct a study to prove the device meets such criteria for diagnostic performance. Instead, this submission is for a medical device (a Positive Airway Pressure Valve) where the primary evaluation is for substantial equivalence to a predicate device.

    The "acceptance criteria" are implicitly derived from the performance of the predicate device and the requirement that the new device performs "in a similar manner" within established specifications. The study described is a comparative performance test to demonstrate this substantial equivalence.


    Acceptance Criteria and Reported Device Performance

    Acceptance CriteriaReported Device Performance
    Pressure Equivalence: Performance similar to predicate device within established specifications of ± 1 cm H₂O across flow rates of 4-12 L/min and pressures of 1-10 cm H₂O.Met: "Results indicated both PAP valves performed in a similar manner within established specifications of ± 1cm H20 with comparable test data."
    Water Level Change (Accumulation): Rate of water level change during simulated use should be equivalent to the predicate device.Met: "Results indicated the WaterPAP and Babi*Plus Valves accumulate an equivalent amount of water and therefore the Positive Airway Pressures changes in both valves are essentially equivalent."
    Response to Increased Flow Rates (Pressure Increase): Should demonstrate similar behavior to the predicate device in generating increased pressures with increased flow rates.Met: "The results demonstrate that the WaterPAP and Babi.Plus valves both generate increased pressures with increase flow rates." (The finding that both are predominantly above depth settings and require gauge reliance is an observation about both devices, not a failure of the WaterPAP to meet a comparative criterion).
    Resistance to Flow through Air Diffusers: Resistance should be within an acceptable range, ideally comparable to the predicate device, not negatively impacting intended use.Met: "The results showed that the WaterPAP Valve had slightly higher resistance across the full range of flow rates; however the resistance to flow in both devices is well below a level that could have a negative impact during their intended use." (Despite being slightly higher, it's considered acceptable).

    Study Details

    1. Sample Size Used for the Test Set and Data Provenance:

      • Sample Size: Not applicable in the traditional sense of patient data. The "test set" consists of multiple configurations of flow and pressure combinations (flow rates 4-12 L/min and pressures 1-10 cm H₂O). The exact number of unique combinations tested is not specified but described as "a full range."
      • Data Provenance: The data is from bench testing (simulated use), not clinical or patient data. Therefore, country of origin related to patient data is not relevant. It is a prospective bench study comparing the two devices.
    2. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts:

      • Not applicable. This study is a bench test evaluating physical performance characteristics (pressure, flow, water level changes, resistance) against predefined engineering specifications and comparison to a predicate device. It does not involve expert interpretation or diagnostic ground truth.
    3. Adjudication Method for the Test Set:

      • Not applicable. No human interpretation or adjudication was involved in generating the performance data.
    4. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

      • No. This is not an AI-assisted diagnostic device, nor is it a multi-reader, multi-case study. It's a bench test of a mechanical device.
    5. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

      • Not applicable. This is a mechanical device, not an algorithm. The "standalone" performance is the bench testing of the device itself.
    6. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

      • The "ground truth" here is the measured physical performance characteristics of the predicate device (Babi*Plus Bubble PAP Valve) and the established engineering specifications for such devices (e.g., ± 1 cm H₂O tolerance). The WaterPAP Valve's performance is compared against these established values.
    7. The sample size for the training set:

      • Not applicable. This is a mechanical device, not a machine learning algorithm, so there is no "training set."
    8. How the ground truth for the training set was established:

      • Not applicable. There is no training set for this type of device submission.
    Ask a Question

    Ask a specific question about this device

    K Number
    K103833

    Validate with FDA (Live)

    Date Cleared
    2011-04-20

    (111 days)

    Product Code
    Regulation Number
    868.5965
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    name:

    Attachment, Breathing, Positive End Expiratory Pressure

    Classification:

    Anesthesiology 21 CFR 868.5965
    Re: K103833

    Trade/Device Name: NeoPIP™ Resuscitation Circuit with PEEP Regulation Number: 21 CFR 868.5965

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The NeoPIP™ Resuscitation Circuit with PEEP is indicated as an accessory to add positive end expiratory pressure breathing capability to a T-Piece Resuscitator. The PEEP valve is incorporated into the breathing circuit T-Piece with a standard fitting for face mask, laryngeal mask or endotracheal tube. The NeoPIP Resuscitation Circuit with PEEP is indicated for use in neonatal patients < 10Kg.

    Device Description

    The NeoPIP™ Resuscitation Circuit with PEEP control valve is a breathing circuit intended for use with manual resuscitation devices for emergency neonatal resuscitation.

    AI/ML Overview

    The provided text does not contain information about acceptance criteria or a study that proves a device meets such criteria in the context of AI/ML performance. The document describes a 510(k) summary for a medical device called "NeoPIP™ Resuscitation Circuit with PEEP," which is a physical breathing circuit for neonatal resuscitation.

    The submission focuses on establishing substantial equivalence to a predicate device based on design, materials, and operational and technological characteristics, not on the performance of a software algorithm or AI model. Therefore, directly answering the questions related to AI/ML performance metrics, sample sizes for test/training sets, experts, and ground truth as outlined in the prompt is not possible from the provided text.

    Here's a breakdown of why each requested point cannot be addressed:

    1. Table of acceptance criteria and reported device performance: Not applicable. The document discusses "performance data" in the sense of demonstrating equivalence to a predicate device, not in the context of specific quantitative performance metrics for an AI/ML system.
    2. Sample size for test set and data provenance: No test set is mentioned, as this is a hardware device.
    3. Number of experts used to establish ground truth and qualifications: Not applicable. Ground truth for AI/ML is not relevant for this device.
    4. Adjudication method: Not applicable.
    5. Multi-reader multi-case (MRMC) comparative effectiveness study: Not applicable, as it's not an AI-assisted diagnostic tool.
    6. Standalone (algorithm only) performance: Not applicable, as there is no algorithm described.
    7. Type of ground truth used: Not applicable.
    8. Sample size for training set: Not applicable.
    9. How ground truth for the training set was established: Not applicable.

    Instead, the document focuses on:

    • Intended Use: An accessory to add positive end expiratory pressure (PEEP) breathing capability to a T-Piece Resuscitator for neonatal patients < 10Kg.
    • Substantial Equivalence: Claimed based on similarity in intended use, design, operational and technological characteristics, and principles of operation to legally marketed predicate devices (K070416 NeoPEEP Neonatal Resuscitation Circuit with PEEP and Fisher & Paykel NEOPUFF Infant Resuscitator patient circuit with PEEP).
    • Performance Data (for equivalence): States that the technological characteristics (design and materials) are the same as the predicate device and that performance data demonstrate equivalence to the predicate device. This implies engineering or functional testing to ensure the device operates as expected and similarly to the predicate, not AI/ML performance evaluation.