Found 416 results

510(k) Data Aggregation

    K Number
    K250322

    Validate with FDA (Live)

    Date Cleared
    2025-07-24

    (170 days)

    Product Code
    Regulation Number
    868.5905
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Trade/Device Name: Respond OC Conserving Regulator (130-0800)
    Regulation Number: 21 CFR 868.5905
    Regulator (130-0800)
    Classification Name: Conserver, Oxygen
    Product Code: NFB
    CFR: 21 CFR 868.5905
    800 – K070740
    Classification Name: Conserver, Oxygen
    Product Code: NFB
    CFR: 21 CFR 868.5905
    Therapeutics | |
    | Prescription Device | Yes | Yes | Similar |
    | Device classification and Product Code | NFB 868.5905
    | NFB 868.5905 | Similar |
    | Indications for Use | The Respond OC Conserving Regulator is intended for

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Respond OC Conserving Regulator (130-0800) is intended for prescription use only, to be used as part of a portable oxygen delivery system for patients that require supplemental oxygen in their home and for ambulatory use. It may also be used to deliver a constant flow of oxygen to the patient.

    Device Description

    The Respond OC Conserving Regulator (130-0800) is a dual mode high pressure oxygen regulator and conserving device that allows for either a continuous or conserve flow of medical grade oxygen to the patient. The device is designed with a CGA 870 style yoke for use with ambulatory oxygen cylinders. The integrated regulator reduces cylinder pressure to 22psig (+/-3psi) to the sensing diaphragm which allows the Respond OC to sense the start of inhalation by the patient and release a controlled amount of oxygen by pneumatic timing in short bursts into the lungs via an oxygen cannula. The Respond OC supports a delivered oxygen equivalency of 1 to 5 LPM in the conserve mode, which extends the ambulatory time of cylinders up to 6:1 based on the cylinder pressure and selected setting. The continuous flow mode offers settings of 2, 3 and 4 LPM if the patient requires a constant flow of oxygen.

    AI/ML Overview

    The provided FDA 510(k) clearance letter and summary for the Respond OC Conserving Regulator (K250322) outlines the device, its intended use, and its substantial equivalence to a predicate device. However, this documentation does not contain the detailed information typically found in a clinical study report or a comprehensive test report regarding acceptance criteria and the study that proves the device meets them, especially in the context of AI/ML-based medical devices or diagnostic tools.

    The device described (an oxygen conserving regulator) is a mechanical device, not an AI/ML-driven diagnostic or treatment device. Therefore, many of the typical requirements for AI/ML device studies (such as MRMC, expert consensus for ground truth, training set details, and specific performance metrics like sensitivity/specificity/AUC) are not applicable here.

    The document primarily focuses on bench testing and biocompatibility to demonstrate substantial equivalence to a predicate mechanical device.

    Here's an analysis based on the provided document, highlighting what is and is not present concerning "acceptance criteria" and "study proof":


    Analysis of Acceptance Criteria and Study Proof for Respond OC Conserving Regulator (K250322)

    Based on the provided FDA 510(k) Summary, the device is a mechanical oxygen conserving regulator. The "acceptance criteria" and "study proof" are framed in the context of demonstrating substantial equivalence to a predicate mechanical device through non-clinical (bench) testing and biocompatibility assessments, rather than clinical efficacy studies or AI/ML performance evaluations.

    1. Table of Acceptance Criteria and Reported Device Performance

    The document summarizes the types of tests conducted and states that the device "met its acceptance criteria" and "performs similarly to the predicate device." However, it does not explicitly list the specific quantitative acceptance criteria for each test (e.g., a specific tolerance for oxygen flow, a defined pass/fail for impact resistance) nor does it present the raw, quantitative reported performance results against these criteria. Instead, it provides qualitative statements of compliance.

    Acceptance Criteria (Inferred from Test Types)Reported Device Performance (as stated in document)
    Biocompatibility:
    ISO 18562-2 – Emissions of Particulate Matter"met the applicable requirements for biocompatibility safety"
    ISO 18562-3 – Emissions of VOCs with Toxicological Risk Assessment"met the applicable requirements for biocompatibility safety"
    Bench Testing:
    Accelerated Aging performance"demonstrated that the subject device met its acceptance criteria"
    Flow Comparison with predicate"performs similarly to the predicate device"
    Flow Regulation Test performance"demonstrated that the subject device met its acceptance criteria"
    Conservation Testing savings ratio (e.g., 6:1)"demonstrated that the subject device met its acceptance criteria" (specifically states 6:1 savings ratio achieved, similar to predicate)
    Promoted Ignition Burst Pressure Test (ASTM G 175-24)"Passed ASTM G 175-24" (similar to predicate's G 175-03)
    Environmental Testing (e.g., temperature, humidity)"demonstrated that the subject device met its acceptance criteria"
    Altitude Test performance"demonstrated that the subject device met its acceptance criteria"
    Flow Response Test (e.g., bolus delivery, trigger)"performs similarly to the predicate device"; "Conserve mode: Senses a breath and delivers in first 1/3 of breath cycle"
    Impact Test performance"demonstrated that the subject device met its acceptance criteria"
    Functional Equivalence:
    Selectable Outlet Flow (Continuous: 2, 3, 4 lpm); (Conserve: 1-5 lpm)Match stated levels (Implicitly met for substantial equivalence claim)
    Oxygen Bolus Size (ml) at 20 BPM (specific ml per lpm setting)Conserve 1 lpm: 11 ml; 2 lpm: 24 ml; 3 lpm: 37 ml; 4 lpm: 46 ml; 5 lpm: 54 ml (Similar to predicate)
    Regulator Outlet Pressure (22 PSI)Match stated 22 PSI (Similar to predicate's 25 PSI)
    Breaths Per Minute (bpm) support (Up to 35 bpm)Met (Predicate: 14 to 40 bpm)

    2. Sample Size for the Test Set and Data Provenance

    Given this is a physical device, the "test set" refers to the manufactured units subjected to bench testing. The document does not specify the sample size (number of devices) used for each of the non-clinical tests (e.g., how many units were subjected to accelerated aging, or impact testing).

    Data Provenance: The data provenance is from non-clinical bench testing conducted by the manufacturer, Responsive Respiratory, Inc. It's not clinical data or retrospective/prospective human data. The country of origin for the testing itself is not explicitly stated but would typically be where the manufacturer's testing facilities are located.

    3. Number of Experts Used to Establish Ground Truth and Qualifications

    This question is not applicable as the device is a mechanical oxygen regulator, not an AI/ML-driven diagnostic or classification device requiring expert-established ground truth from medical images or patient data. Ground truth for its performance would be established through calibrated laboratory equipment measuring physical parameters (flow, pressure, timing, etc.) against engineering specifications.

    4. Adjudication Method for the Test Set

    This question is not applicable for a mechanical device undergoing bench testing. Adjudication typically refers to resolving discrepancies between human readers or between AI and human readings. Test results for mechanical parameters are either within specification or not, based on objective measurements.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was done

    No, an MRMC comparative effectiveness study was not done. This type of study is relevant for diagnostic devices (especially those using AI/ML) where human readers (e.g., radiologists) interpret cases, and the effectiveness of AI assistance on their performance is evaluated. The Respond OC Conserving Regulator is a therapeutic/delivery device, not a diagnostic one.

    6. If a Standalone (i.e. algorithm only without human-in-the loop performance) was done

    This question is not applicable in the typical sense for this device. There is no "algorithm" in the way an AI/ML device would have one. The device's "performance" is its mechanical function. The "bench testing" described in the summary is the standalone performance assessment of the device's mechanical and pneumatic operation (e.g., flow rates, bolus timing, pressure regulation) without human intervention beyond setting the controls for the test.

    7. The Type of Ground Truth Used

    For the bench tests, the "ground truth" would be physical measurements against engineering specifications and industry standards. For example:

    • Flow rates: Measured by calibrated flow meters against specified LPM settings.
    • Pressure: Measured by calibrated pressure gauges against specified PSI output.
    • Timing of bolus delivery: Measured by sensors and timers to confirm delivery within the specified inspiratory cycle.
    • Biocompatibility: Confirmed by laboratory analysis against ISO standards.
    • Ignition Sensitivity: Confirmed by testing against ASTM standards.

    It is not expert consensus, pathology, or outcomes data, as these are related to clinical diagnosis or patient outcomes, not the performance of a mechanical oxygen delivery device.

    8. The Sample Size for the Training Set

    This question is not applicable. There is no "training set" as this is not an AI/ML device that requires data for model training.

    9. How the Ground Truth for the Training Set was Established

    This question is not applicable for the same reason as point 8.

    Ask a Question

    Ask a specific question about this device

    K Number
    K243583

    Validate with FDA (Live)

    Date Cleared
    2025-06-18

    (210 days)

    Product Code
    Regulation Number
    868.5905
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    New Zealand

    Re: K243583
    Trade/Device Name: F&P Nova Nasal Mask
    Regulation Number: 21 CFR 868.5905
    Classification Name: Non Continuous Ventilator (IPPB)
    Regulatory Class: Class II (21 CFR §868.5905
    Healthcare Limited | |
    | Product Code | BZD | BZD | Identical. |
    | Device Classification | 21 CFR §868.5905
    | 21 CFR §868.5905 | |
    | Classification Panel | Anaesthesiology | Anaesthesiology | |
    | **Indications

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    A-Model
    The F&P Nova Nasal Mask is intended to be used by adults aged 22 years and older weighing ≥ 66 lb (30 ks) who have been prescribed non-invasive positive airway pressure therapy such as CPAP or Bi-Level by a physician. The Nova Nasal mask is intended for single-patient use in the home.

    SLA-Model
    The F&P Nova Nasal mask is intended to be used by adults aged 22 years and older weighing ≥ 66 lb (30 kg) who have been prescribed non-invasive positive airway pressure therapy such as CPAP or Bi-Level by a physician. The Nova Nasal mask is intended for single-patient use in the home and for multiple patient use in the hospital or other clinical setting where proper disinfection of the device can occur between patient uses.

    Device Description

    The F&P Nova Nasal Mask is a non-invasive, Positive Airway Pressure (PAP) therapy nasal mask that features an over-the-nose cushion that seals the patient's nose, held in place by adjustable headgear straps. The mask is designed to aid in the delivery of PAP by providing an interface between the flow generator and tubing, and the patient. The F&P Nova Nasal Mask is a prescription-only device, provided in a non-sterile state.

    The Nova Nasal Mask range is available in three cushion sizes – Small, Medium, and Large.

    The mask has two models: A-Model and Sleeplab (SL) A-Model. Both models are identical except for their Indications for Use, Operating Environment, and Reusability. The A-Model is intended to be single-patient use in the home, while the SL A-Model is intended to be used on multiple patients in a hospital or other clinical setting where proper disinfection of the device can occur between patient uses.

    AI/ML Overview

    I am sorry, but based on the provided FDA 510(k) Clearance Letter and the accompanying 510(k) Summary, there is no information provided regarding acceptance criteria for an AI/ML powered medical device, nor any study details that would prove such a device meets these criteria.

    The document describes the clearance of a physical medical device, the F&P Nova Nasal Mask, which is a non-invasive positive airway pressure (PAP) therapy nasal mask. The performance data section lists standard engineering and biocompatibility tests typically performed on such devices (e.g., cleaning validation, leak, CO2 rebreathing, resistance to flow, vibration and noise, dead space analysis, human factors, mechanical integrity, shelf-life, and various ISO standards related to masks and biological evaluation).

    Therefore, I cannot fulfill your request to describe acceptance criteria and a study for an AI-powered device using this document. The information you are asking for (e.g., sample sizes for test/training sets, data provenance, number/qualifications of experts for ground truth, adjudication methods, MRMC studies, standalone performance, type of ground truth) are specifically relevant to the validation of AI/ML algorithms in medical devices, which this document does not cover.

    Ask a Question

    Ask a specific question about this device

    K Number
    K250624

    Validate with FDA (Live)

    Device Name
    myAir
    Manufacturer
    Date Cleared
    2025-05-28

    (86 days)

    Product Code
    Regulation Number
    868.5905
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    San Diego, California 92123

    Re: K250624
    Trade/Device Name: myAir
    Regulation Number: 21 CFR 868.5905
    not raise new questions of safety or efficacy for the subject device. |
    | Regulation Number | 21 CFR §868.5905
    | 21 CFR §868.5905 | Identical |
    | Classification Name | Noncontinuous ventilator (IPPB) | Noncontinuous

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The myAir app is indicated for patients:

    • prescribed with a compatible ResMed Air11 platform device to simulate therapy prior to using their device with their prescribed settings, and to configure their settings to support therapy. It is an optional software accessory to allow patients to acclimate to and operate their therapy device.
    • prescribed a NightOwl wearable device to provide the user interface to operate the connected device and aid in the home sleep testing process.

    The device is intended for home and hospital use for:

    • new and existing patients of ResMed Air10 and Air11 PAP therapy devices and
    • new users who are prescribed a compatible NightOwl home sleep test (HST).
    Device Description

    myAir is a companion mobile medical application ("app") that serves as a patient self-monitoring, therapy usage tracking, and engagement platform for patients prescribed with compatible ResMed PAP therapy devices and the NightOwl home sleep test (HST) sensors. The app allows the patient to connect via Bluetooth to a compatible hardware device for control of their prescribed PAP or HST device and to allow self-tracking of device usage data. myAir can also be used as a communication pathway using the Bluetooth connection with the compatible device in order to send or receive data. Analysis of patient diagnostic data or display of diagnostic results are not in scope of myAir features.

    The myAir subject device for this premarket submission adds device software functions related to starting and stopping therapy, and control of comfort settings (collectively referred to as "device control"). The addition of these device software functions within the myAir subject device is a modification to the K241216 myAir predicate device, in addition to sustaining previously cleared medical device functions.

    AI/ML Overview

    It appears the provided document is an FDA Clearance Letter for the "myAir" device, specifically a 510(k) summary. This type of document primarily focuses on establishing substantial equivalence to a predicate device, rather than detailing the full scope of acceptance criteria and the comprehensive study results typically found in a clinical study report or a more detailed technical submission.

    Based on the provided text, the device "myAir" is a companion mobile medical application. The submission is for a modified device, adding "device software functions related to starting and stopping therapy, and control of comfort settings (collectively referred to as 'device control')".

    Therefore, the study detailed is primarily non-clinical verification and validation testing of software functions introduced with these modifications. The document states:

    "Non-clinical verification and validation testing completed for device software functions under review introduced with the modifications to the myAir app demonstrated that the device met all intended performance requirements. Testing included:

    • Software verification and validation, including non-functional requirements and end-to-end functional testing."

    Given this, I cannot provide detailed information about acceptance criteria and study results for clinical performance or human-in-the-loop studies (MRMC, effect size, etc.), as such studies are not described in this 510(k) summary for a software modification. The focus is on the software's functional performance and adherence to guidance documents for software and cybersecurity.

    Here's what can be extracted from the provided text according to your request, with a clear indication where information is not available in the document:


    Acceptance Criteria and Device Performance for "myAir" (K250624)

    The "myAir" device is a mobile application that received FDA 510(k) clearance (K250624) as a modified device, primarily adding "device control functions" (starting/stopping therapy, controlling comfort settings) for compatible ResMed Air11 platform devices. The acceptance criteria and performance detailed below pertain specifically to the non-clinical verification and validation of these new software functions.

    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance Criteria CategorySpecific Acceptance Criteria (Inferred from document)Reported Device Performance (As stated/inferred from document)
    Software FunctionalityDevice control functions (starting/stopping therapy, comfort settings) operate as intended."device met all intended performance requirements." "Software verification and validation, including non-functional requirements and end-to-end functional testing."
    InteroperabilitymyAir app successfully connects and operates with compatible ResMed Air11 platform devices."Device Interoperability and V&V: Identical [to predicate] - ResMed Air11 platform devices and NightOwl HST." "myAir app must be connected to a compatible AS11 or HST device to operate device functions as intended."
    Compliance with FDA GuidanceAdherence to relevant FDA guidance for medical device software and cybersecurity."The following FDA guidance were conformed to: Content of Premarket Submissions for Device Software Functions: June 2023; Cybersecurity in Medical Devices: Quality System Considerations and Content of Premarket Submissions: September 2023."
    Safety and EffectivenessThe additions to the device do not raise new questions of safety or effectiveness."The differences [from predicate] do not raise any new questions of safety or effectiveness; and It is as safe and effective as the predicate device."

    2. Sample Size Used for the Test Set and Data Provenance

    • Sample Size for Test Set: Not specified. The document mentions "Software verification and validation, including non-functional requirements and end-to-end functional testing." This typically involves a range of test cases, but the specific number is not disclosed in this summary.
    • Data Provenance: The document describes "non-clinical verification and validation testing." This implies internal testing conducted by the manufacturer (ResMed Corp, USA). It does not involve patient data or clinical datasets. Therefore, provenance (country, retrospective/prospective) is not applicable in the typical sense of a clinical study.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Their Qualifications

    • Not Applicable/Not specified. For non-clinical software verification and validation, "ground truth" is typically defined by functional requirements specifications and design documents. The testing validates that the software performs according to these pre-defined specifications. Expert human readers or adjudicators are not typically involved in establishing ground truth for this type of testing.

    4. Adjudication Method for the Test Set

    • Not Applicable/None stated. As the testing is non-clinical software verification, adjudication methods like 2+1 or 3+1 (common in image interpretation studies) are not relevant here. The success or failure of a test case is determined by whether the software performs as specified.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done

    • No. An MRMC study was not conducted as part of this submission, based on the provided document. The submission pertains to software functionality and its substantial equivalence, not to comparative effectiveness for human readers.
    • Effect Size of Human Readers Improvement with AI vs. Without AI Assistance: Not applicable, as no MRMC study or human reader performance evaluation was described. The "myAir" app is an accessory for device control and patient engagement, not an AI diagnostic tool assisting human readers.

    6. If a Standalone (i.e., Algorithm Only Without Human-in-the-Loop Performance) Was Done

    • Yes, implicitly. The "non-clinical verification and validation testing" is a form of standalone testing for the software's functional performance. The software is tested to operate its intended device control functions (starting/stopping therapy, comfort settings) without direct human intervention in the execution of those specific software commands once initiated. However, this is not "standalone performance" in the sense of a diagnostic algorithm's accuracy, sensitivity, or specificity. It's about the software performing its programmed tasks correctly.

    7. The Type of Ground Truth Used

    • Functional Requirements and Design Specifications. For this type of software verification, the "ground truth" is established by the detailed specifications of how the software functions are designed to operate. Test cases are then executed to confirm that the actual software behavior matches these expected behaviors. No clinical ground truth (e.g., pathology, outcomes data, expert consensus on patient conditions) is mentioned as being used for the specific software modifications under review.

    8. The Sample Size for the Training Set

    • Not Applicable/Not disclosed. Since this is software functional verification and validation for a non-AI/ML application (it controls a medical device and provides user interface), there is no "training set" in the sense of data used to train a machine learning model. The software's logic is developed through traditional programming methods, not data training.

    9. How the Ground Truth for the Training Set Was Established

    • Not Applicable. See point 8. No training set for an AI/ML model is indicated, so no ground truth establishment process for a training set is relevant or described.
    Ask a Question

    Ask a specific question about this device

    K Number
    K243023

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-05-23

    (238 days)

    Product Code
    Regulation Number
    868.5905
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Re: K243023
    Trade/Device Name: WiZARD 520 Full Face Mask
    Regulation Number: 21 CFR 868.5905
    Face Mask |
    |---|---|
    | Classification product Code: | BZD |
    | Regulation number: | 21 CFR 868.5905
    Manufacturer:** | Wellell Inc. |
    | Classification product code: | BZD |
    | Regulation number: | 21 CFR 868.5905
    Comments** |
    |---|---|---|---|
    | Product Code | BZD | BZD | Equivalent |
    | Regulation Number | 868.5905
    | 868.5905 | Equivalent |
    | Indications for Use | WIZARD 310/320 series CPAP Mask is intended to

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Mask is intended to provide an interface for Continuous Positive Airway Pressure (CPAP) or bi-level therapy. The Mask is intended for single-patient reuse in the home and multi-patient multi-use in the hospital environment.

    The Mask is to be used by adults weighing ≥ 30 kg whom positive airway pressure (CPAP or bi-level system) has been prescribed.

    Device Description

    WiZARD 520 Full Face Mask's cushion and frame provide a secure interface between the mask and the patient's face and the flexible cushion improves seal. A series of vents on the elbow, serve as an exhalation vent to purge the exhaled carbon dioxide from the mask. The mask is designed to maintain a continuous airflow to minimize the amount of CO2 rebreathed by the patient. The mask features a wider visibility design that ensures a clear line of sight. It also includes a fabric frame equipped with 3D-shaped headgear for enhanced comfort and stability.

    WiZARD 520 Full Face Mask is intended for connection to a positive air pressure source such as CPAP or bi-level for the treatment of Obstructive Sleep Apnea. WiZARD 520 Full Face Mask can be linked to the CPAP or bi-level system's standard 22 mm breathing tube using a swivel hose, flexible tube, and tubing connector. Various sizes (small, medium, and large) are offered to ensure adequate fit over the extended patient population.

    AI/ML Overview

    The provided text is an FDA 510(k) clearance letter for the WiZARD 520 Full Face Mask. This document describes the substantial equivalence of the new device to a predicate device, focusing on its physical and functional characteristics. It does not describe a study proving the device meets acceptance criteria related to an AI/Machine Learning model, nor does it provide information relevant to a Multi-Reader Multi-Case (MRMC) comparative effectiveness study or the establishment of ground truth by expert consensus.

    The clearance is for a physical medical device (a CPAP mask), not a software or AI-driven diagnostic tool. Therefore, the concepts of "acceptance criteria for an AI model," "sample size for test/training sets," "number of experts for ground truth," "adjudication method," "MRMC study," or "standalone algorithm performance" are not applicable to this document.

    The document discusses performance tests that are standard for a physical medical device, such as CO2 rebreathing, pressure-flow characteristics, resistance to flow, anti-asphyxia valve operating pressures, and sound levels. These are engineering and physiological performance metrics, not metrics for an AI's diagnostic accuracy or expert agreement.

    Therefore, I cannot fulfill your request using the provided input, as the input material does not contain the type of information you've asked for. It's crucial to understand that a 510(k) for a physical medical device like a CPAP mask does not involve AI development or validation processes.

    Ask a Question

    Ask a specific question about this device

    K Number
    K242547

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-05-19

    (265 days)

    Product Code
    Regulation Number
    868.5905
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Trade/Device Name:** AirFit F20 Mask System; AirFit F20 NM Mask System
    Regulation Number: 21 CFR 868.5905
    Device Common Name: Vented Full Face Mask

    Classification and Classification Name: 21 CFR 868.5905

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    AirFit F20 Mask System:

    The AirFit F20 mask has two product variants:

    • AirFit F20 mask is intended for single-patent reuse in the home environment.
    • AirFit F20 SLM (Sleep Lab Mask) variant is intended for multi-patient reuse in the hospital/institutional environment.

    Both masks are intended for patients weighing more than 66lb (30kg), who have been prescribed non-invasive CPAP or bi-level positive airway pressure (PAP) therapy. The Sleep Lab Mask is the only variant that is validated and intended for multi-patient reprocessing and must be reprocesssed if reused between patients.

    AirFit F20 NM Mask System:

    The AirFit F20 Non Magnetic mask has two product variants:

    • The AirFit F20 Non Magnetic variant is intended for single-patient reuse in the home environment.
    • The AirFit F20 Non Magnetic SLM (Sleep Lab Mask) variant is intended for multi-patient reuse in the hospital/institutional environment.

    This mask is for patients weighing more than 66 lb (30 kg), who have been prescribed non-invasive CPAP or bi-level positive airway pressure (PAP) therapy. The Sleep Lab Mask is the only variant that is validated and intended for multi-patient reprocessing and must be reprocessed if reused between patients.

    Device Description

    The AirFit F20 and AirFit F20 NM Mask Systems are both full-face masks intended for use with Continuous Positive Airway Pressure (CPAP) and/or Bi-Level devices. CPAP & Bi-Level devices are used for the treatment of Obstructive Sleep Apnea (OSA) and/or ventilatory support. Both treatments deliver pressurized air from a flow generator to the patient. Such delivery of pressurized air relies on the Patient Interface; commonly known as the mask. Full face masks are a common type of Patient Interface (Mask) and are known to efficaciously support the delivery of pressurized air by providing a seal around the patient's nose and mouth.

    The AirFit F20 mask system has two product variants:

    • AirFit F20 Mask: This is the home use variant that is intended for single patient re-use.
    • AirFit F20 SLM (sleep lab mask): This is the variant that is intended for multi-patient re-use and must be reprocessed if reused between patients using the disinfection guide.

    AirFit F20 (K170924) had a "For Her" variant which was cleared with aesthetic colour pops, the AirFit F20 Mask and AirFit F20 SLM also have the same "For Her" variant.

    The AirFit F20 NM mask system has two product variants:

    • AirFit F20 NM Mask: This is the home use variant that is intended for single patient re-use.
    • AirFit F20 NM SLM (sleep lab mask): This is the variant that is intended for multi-patient re-use and must be reprocessed if reused between patients using the disinfection guide.

    The AirFit F20 and AirFit F20 NM Mask Systems share a common design architecture as the predicate AirFit F20 (K170924), except that the AirFit F20 NM Mask System has non-magnetic clips.

    The AirFit F20 and AirFit F20 NM mask systems are made up of the following four main component assemblies: cushion, elbow, frame, and headgear. The cushion and headgear are available in various sizes to allow for adequate mask fit over the intended patient population.

    The AirFit F20 and AirFit F20 NM mask systems are prescription devices supplied non-sterile.

    AI/ML Overview

    The provided FDA 510(k) clearance letter and associated summary pertain to the AirFit F20 Mask Systems, which are non-continuous ventilators (CPAP/Bi-Level masks). This type of device does not typically involve complex diagnostic algorithms or AI components that would necessitate the study structure outlined in your request (e.g., test sets, ground truth, expert adjudication, MRMC studies, standalone performance for AI).

    Instead, the clearance is based on demonstrating substantial equivalence to a predicate device (AirFit F20, K170924) through non-clinical performance and safety testing, adherence to recognized standards, and biocompatibility evaluations.

    Therefore, many of the specific questions you've asked cannot be directly answered from this document as they are not relevant to the type of device and clearance process involved.

    Here's an attempt to extract the relevant information and address your questions where possible:


    1. Table of Acceptance Criteria and Reported Device Performance

    The document does not explicitly present a "table of acceptance criteria" with corresponding "reported device performance" in a format typically used for diagnostic algorithm validation. Instead, it compares specific design parameters and performance characteristics of the new devices (AirFit F20 Mask System and AirFit F20 NM Mask System) against the predicate device (AirFit F20, K170924). The "Comments" column often indicates that the performance is "Equivalent" or "Identical," implying that the new devices meet or perform similarly to the established safety and performance profile of the predicate, which serves as the de facto acceptance benchmark.

    Here's a summary derived from the comparison table (Pages 9-12 of the provided document):

    Design parameter or featurePredicate device: AirFit F20, K170924 (Performance/Criteria based on predicate)Modified device: AirFit F20 Mask System (Reported Performance)Modified device: AirFit F20 NM Mask System (Reported Performance)Acceptance Criteria (Implied)
    Indications for UseSpecified for CPAP/bi-level, >66lb (30kg), single-patient home, multi-patient hospital use.Equivalent to predicate, with variants for home/sleep lab use.Equivalent to predicate, with variants for home/sleep lab use.Equivalent to predicate
    Intended UseInterface for CPAP/bi-level devices.IdenticalIdenticalIdentical to predicate
    FDA Product CodeBZDBZDBZDIdentical to predicate
    Patient populationWeighing more than 66 lb (30 kg)Patients weighing more than 66lb (30kg)Patients weighing more than 66lb (30kg)Identical to predicate
    Environment of UseHome or health institutionHome or health institutionHome or health institutionIdentical to predicate
    Reprocessing claimsSingle patient re-use or multi-patient re-use.IdenticalIdenticalIdentical to predicate
    Sterility state as providedNon-sterileNon-sterileNon-sterileIdentical to predicate
    Validated reprocessing methodsHigh-Level Thermal disinfection, SterilizationHigh-Level Thermal disinfection, SterilizationHigh-Level Thermal disinfection, SterilizationIdentical to predicate
    Vent typeMulti-hole ventMulti-hole vent and diffuser ventMulti-hole vent and diffuser ventEquivalent to predicate's safety/efficacy profile
    PAP tubing connection pointISO 5356-1 (22mm)ISO 5356-1 (22mm)ISO 5356-1 (22mm)Identical to predicate
    Construction materialPolymeric, Textile, magnetsPolymeric, Textile, magnetsPolymeric, TextileEquivalent to predicate's safety/efficacy profile (NM variant removes magnets)
    Operating pressure range (cmH2O)3 - 403 – 403 – 40Identical to predicate
    SizesCushion (3), Headgear (3), Frame (1)IdenticalIdenticalIdentical to predicate
    Mask exhaust flow (Nominal) ISO 17510:2015 Annex BPressure (cm H2O): 3, 20, 40 -> Flow (L/min) 'Full Face' curve: 20.1, 55.5, 82.4Pressure (cm H2O): 3, 20, 40 -> Flow (L/min) 'Full Face' curve: 19, 54, 82Pressure (cm H2O): 3, 20, 40 -> Flow (L/min) 'Full Face' curve: 19, 54, 82Equivalent to predicate (minor differences within acceptable range for substantial equivalence)
    CO2 rebreathing performance (normal condition) ISO 17510:2015 Annex FPressure (cm H2O): 3, 5, 10 -> Relative CO2 increase Non-SLM: 14.8%, 7.5%, 6.8% SLM: 11.7%, 7.3%, 2.9%Pressure (cm H2O): 3, 5, 10 -> Relative CO2 increase Non-SLM: ≤ 11.4%, ≤ 11.4%, - SLM: 11.7%, 7.3%, 2.9%Pressure (cm H2O): 3, 5, 10 -> Relative CO2 increase Non-SLM: ≤ 11.4%, ≤ 11.4%, - SLM: 11.7%, 7.3%, 2.9%Equivalent (<20%) (as per ISO standard for substantial equivalence)
    CO2 rebreathing performance (single fault condition) ISO 17510:2015 Annex FFault (ISO 17510:2015) -> Relative CO2 increase Non-SLM: 32.3%, 39.5% SLM: 40.5%, 52.7%Fault (ISO 17510:2015) -> Relative CO2 increase Non-SLM: ≤ 53.1%, ≤ 53.1% SLM: 40.5%, 52.7%Fault (ISO 17510:2015) -> Relative CO2 increase Non-SLM: ≤ 53.1%, ≤ 53.1% SLM: 40.5%, 52.7%Equivalent (<60%) (as per ISO standard for substantial equivalence)
    Resistance to flow (Pressure drop across mask in cmH2O) ISO 17510:2015 Annex C@50 L/min: <0.8 cmH2O @100 L/min: <1.6 cmH2O@50 L/min: <0.8 cmH2O @100 L/min: <1.6 cmH2O@50 L/min: <0.8 cmH2O @100 L/min: <1.6 cmH2OEquivalent (Identical performance)
    Breathing Resistance (cmH2O) ISO 17510:2015 Annex EInspiratory: 0.44 @ 50L/min Expiratory: 0.60 @ 50L/minInspiratory: 0.6 @ 50L/min Expiratory: 0.80 @ 50L/minInspiratory: 0.6 @ 50L/min Expiratory: 0.80 @ 50L/minEquivalent (within acceptable limits for substantial equivalence)
    AAV Operating Pressures ISO 17510:2015 Annex DDe-activation: 1.5 cm H2O Activation: 1.0 cm H2ODe-activation: 2.0 cm H2O Activation: 1.5 cm H2ODe-activation: 2.0 cm H2O Activation: 1.5 cm H2OEquivalent (within acceptable limits for substantial equivalence)
    Flow generator setting on compatible ResMed CPAP and Bi-level flow generators"Full face""Full face""Full face"Identical to predicate
    SoundSound power level: 30 dBA Sound pressure level: 23 dBAMulti-hole vent: 30 dBA power, 22 dBA pressure. Diffuser vent: 21 dBA power, 13 dBA pressure.Multi-hole vent: 30 dBA power, 22 dBA pressure. Diffuser vent: 21 dBA power, 13 dBA pressure.Equivalent to predicate (Diffuser vent improves sound)
    Operating and storage temperatureOperating: 5°C to 40°C Storage: -20°C to +60°CIdenticalIdenticalIdentical to predicate
    Magnetic ClipsNumber: 4, Surface Strength: <400 mT, 50mm distance: <0.5 mTNumber: 4, Surface Strength: <400 mT, 50mm distance: <0.5 mTNumber: 0, Surface Strength: N/A, 50mm distance: N/AEquivalent (NM variant removes magnets for specific patient needs)

    2. Sample size used for the test set and the data provenance

    The document states that "Non-clinical verification and validation testing completed for the AirFit F20 and AirFit F20 NM Mask Systems demonstrated that the mask systems met all intended performance requirements." This primarily refers to bench testing and in-vitro studies.

    • Sample Size: Not explicitly stated as a number of "cases" or "patients" in the context of diagnostic performance. For physical device performance, testing involves multiple units of the product to ensure consistency and reliability, but specific sample sizes for tests (e.g., number of masks tested for exhaust flow, CO2 rebreathing, resistance) are not detailed in this summary.
    • Data Provenance: This is not a clinical study in the typical sense. The data comes from non-clinical bench testing conducted by the manufacturer (ResMed Pty Ltd, Australia, with a US office). It is not retrospective or prospective patient data from a particular country, but rather laboratory test results.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    This question is not applicable. The device is a medical mask system, not a diagnostic algorithm that requires expert interpretation for a "ground truth." The "ground truth" for performance is established by recognized international standards (e.g., ISO 17510:2015 for mask performance, ISO 10993 for biocompatibility) and engineering specifications. Compliance is measured against these standards, not expert consensus on medical images or diagnoses.

    4. Adjudication method for the test set

    This question is not applicable for the same reasons as #3. Performance is determined by objective measurements against established standards.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    This question is not applicable. This clearance is for a physical medical device (CPAP/Bi-Level mask), not an AI-powered diagnostic tool. There are no "human readers" or "AI assistance" in the context described for this device.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    This question is not applicable. This is not an algorithm or AI device.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    The "ground truth" for this device's performance is based on:

    • Compliance with international standards: For physical performance (e.g., CO2 rebreathing, exhaust flow, resistance, AAV pressures, sound) as defined by ISO 17510:2015 and other relevant ISO standards.
    • Biocompatibility testing: According to ISO 10993 series and ISO 18562 series.
    • Mechanical integrity testing: To ensure durability after various environmental stressors (home cleaning, transport, storage, operation, free fall, reprocessing).
    • Cleaning and reprocessing validation: Against standards like ISO 17664-1, ISO 17664-2, ST98, and AAMI TIR12.

    Essentially, the ground truth is objective measurement against established engineering and safety standards.

    8. The sample size for the training set

    This question is not applicable. There is no "training set" as this is not a machine learning or AI algorithm.

    9. How the ground truth for the training set was established

    This question is not applicable for the same reasons as #8.

    Ask a Question

    Ask a specific question about this device

    K Number
    K242438

    Validate with FDA (Live)

    Device Name
    Clearo
    Manufacturer
    Date Cleared
    2025-05-16

    (273 days)

    Product Code
    Regulation Number
    868.5905
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Molnlycke, 435 33
    Sweden

    Re: K242438
    Trade/Device Name: Clearo
    Regulation Number: 21 CFR 868.5905
    IPPB) |
    | Classification Name | Non-continuous ventilator |
    | Regulation Number | 21 C.F.R. §868.5905

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Clearo is indicated for use on adult or pediatric patients unable to cough or clear secretions effectively. It may be used either with a facemask or mouthpiece, or with an adapter to a patient's endotracheal or tracheostomy tube. The device is intended to be used in the hospital, institutional environment or in the home.

    Device Description

    The Breas Medical Clearo is an airway clearance device that provides Mechanical Insufflation-Exsufflation (MI-E) therapy. Clearo is indicated for use on adult or pediatric patients who are unable to cough or clear secretions effectively. It may be used either with a facemask or mouthpiece, or with an adapter to a patient's endotracheal or tracheostomy tube. The device is intended to be used in the hospital, institutional environment or in the home.

    The Clearo device is not intended to be used in line with a ventilator.

    Clearo must be prescribed by a licensed physician and must be used only as directed by a physician or healthcare provider.

    Clearo must be used with a single-limb patient circuits fitted an anti-bacterial filter.

    Clearo functions by delivering ambient air at a defined positive pressure to the patient's airways (insufflation), followed by a rapid shift to negative pressure (exsufflation). This quick transition—known as "time through zero" – creates a high expiratory flow that stimulates or simulates a natural cough.

    Optional oscillatory vibrations may further aid in loosening and mobilizing secretions. The continued rapid transition to negative pressure helps generate sufficient expiratory flow from the central airways, supporting the clearance of respiratory secretions.

    Clearo achieves its intended use through a blower, which compresses air, a solenoid-controlled valve to manage air flow and pressure, and microcontroller electronics to control and monitor the operation. Clearo is powered from either a mains source or an internal battery.

    Clearo includes the following device modes to accommodate both clinical and patient use:

    • Unlocked (Clinical) Mode: Provides full access to all treatment settings and mode configurations, intended for use by healthcare professionals. Clinicians can enable specific modes for patient use and customize treatment protocols.
    • Locked (Patient) Mode: Restricts access to pre-selected modes as set by the clinician. Patients cannot modify treatment parameters but may view compliance data and alarm history.

    Clearo provides the following Treatment Modes:

    • Manual Mode: The user controls the cycling between insufflation and exsufflation via a manual switch. This mode supports "Insufflation Rise" to control pressure ramp-up. Sessions can be recorded and stored for repeated use using the Treat-Repeat feature.
    • Basic Auto Mode: Provides repeated, automatic cycling of insufflation, pause, and exsufflation, with configurable recruitment breaths, pause intervals, rise time, and optional patient-triggered breaths. Optional Stepped Insufflation Breaths gradually increases insufflation pressure across breaths for comfort.
    • Program Auto Mode: Similar to Basic Auto but with a customizable, repeatable sequence of multiple insufflations followed by one exsufflation. Includes all features of Basic Auto Mode.
    AI/ML Overview

    This FDA 510(k) clearance letter and summary primarily focus on demonstrating substantial equivalence through technical comparisons and compliance with relevant standards rather than a typical clinical study with acceptance criteria and reported device performance metrics in a tabular format. The document emphasizes performance testing which verifies conformance with requirements, but these are primarily engineering-level tests, not direct clinical performance metrics.

    Therefore, many of the requested points regarding sample size, expert ground truth, adjudication methods, MRMC studies, standalone performance, and ground truth establishment for clinical data are not explicitly detailed in this provided text because the clearance relies on non-clinical performance and substantial equivalence to a predicate device.

    However, I can extract and infer information about the acceptance criteria and study proving device meets them based on the provided text, focusing on the engineering and non-clinical aspects:


    1. A table of acceptance criteria and the reported device performance:

    Based on the provided text, the "acceptance criteria" discussed are primarily adherence to specified technical characteristics and performance within defined ranges, as well as compliance with various medical device standards. The "reported device performance" is framed as the device meeting these specifications and showing comparable waveforms to the predicate.

    Acceptance Criteria CategorySpecific Acceptance Criteria (Inferred from text)Reported Device Performance (Inferred from text)
    Intended UseSame as predicate device (CoughAssist T70)"Clearo is indicated for use on adult or pediatric patients unable to cough or clear secretions effectively... Same"
    Patient PopulationPediatric through adult patients"Pediatric through adult patients... Same"
    Use EnvironmentHome, institutions, hospital"Home, institutions, hospital... Same"
    Pressure RangeInsufflation: 3 to 70 cmH2O; Exsufflation: -3 to -70 cmH2OTested across full range (70 cmH2O, -70 cmH2O) at 10 cmH2O intervals, also 3 cmH2O and -3 cmH2O. Implies performance within these ranges.
    FlowMaximum flow of at least 300 l/minTested to ensure max flow of at least 300 l/min. Implies acceptance criteria met.
    Timing ParametersTi (Inhale Time): 0.5 to 5.0 sec; Te (Exhale Time): 0.5 to 5.0 sec; Pause Time: 0 to 5.0 sec between insufflation breathsTested across their full ranges. Implies performance within these ranges.
    Oscillation PerformanceFrequency range: 1 to 20 Hz; Amplitude range: 1 to 10 cmH2OTested at all combinations of frequency and amplitude ranges. Implies performance within these ranges.
    Waveform ComparisonComparable waveforms to predicate device (CoughAssist T70) across various modes"Results confirm that the Clearo and the CoughAssist T70 predicate have comparable waveforms across the various modes for mechanical insufflation-exsufflation therapy."
    Electrical SafetyConformance to IEC 60601-1:2020 Edition 3.2"verified conformance with all requirements specifications and applicable standards" includingIEC 60601-1:2020.
    EMCConformance to IEC 60601-1-2:2020 Edition 4.1"verified conformance with all requirements specifications and applicable standards" including IEC 60601-1-2:2020.
    UsabilityConformance to IEC 60601-1-6:2020 Edition 3.2 and FDA Guidance"Human factors validation testing was conducted according to the FDA Guidance" and "verified conformance with all requirements specifications and applicable standards" including IEC 60601-1-6:2020.
    Alarms systemsConformance to IEC 60601-1-8:2020 Edition 2.2"verified conformance with all requirements specifications and applicable standards" including IEC 60601-1-8:2020.
    Home Healthcare EnvironmentConformance to HA60601-1-11:2015+A1:2021"verified conformance with all requirements specifications and applicable standards" including HA60601-1-11:2015+A1:2021.
    Pulse Oximeter (if applicable)Conformance to ISO 80601-2-61:2017"verified conformance with all requirements specifications and applicable standards" including ISO 80601-2-61:2017 for accessory.
    BiocompatibilityConformance to ISO 10993-1, ISO 18562-1, -2, -3"Biological evaluation was conducted according to FDA Guidance "Use of International Standard ISO 10993-1" and "Principles of ISO 18562-1:2017... applied". Particulate matter and VOC emissions evaluated and yielded "acceptable... level".
    Cleaning ValidationConformance to FDA Guidance"Cleaning Validation was performed according to FDA Guidance".
    Software V&VConformance to FDA Guidance; System-level validation to user requirements."Software information included Verification and Validation testing per FDA Guidance... System-level validation against user requirement specifications were performed... and have met all acceptance criteria."
    CybersecurityConformance to FDA Guidance"Security Risk Management is employed in conformance to FDA's Guidance for Cybersecurity in Medical Devices".

    2. Sample size used for the test set and the data provenance:

    • Test Set Sample Size: Not explicitly stated as a number of patients or cases. The testing described is primarily non-clinical performance testing (e.g., pressure, flow, timing, oscillation measurements on the device itself, EMC, electrical safety) and waveform comparison against a predicate device.
    • Data Provenance: Not applicable in the context of geographical origin or retrospective/prospective study for clinical data, as this filing relies on engineering performance tests and comparative technological characteristics. It's safe to assume the testing was conducted in a laboratory/engineering environment.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

    • Not applicable/Not mentioned, as the "ground truth" for this submission are the engineering specifications, relevant IEC and ISO standards, and the performance of the predicate device (CoughAssist T70). Expert opinion on clinical efficacy/diagnosis is not the basis for this 510(k) clearance documentation.

    4. Adjudication method for the test set:

    • Not applicable/Not mentioned. Adjudication methods are typically associated with clinical studies involving reader-based interpretations (e.g., radiology images). This submission focuses on objective engineering measurements and compliance with standards.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    • No, an MRMC comparative effectiveness study was not conducted or described. This type of study is relevant for AI/radiology devices where human interpretation is assisted by AI. The Clearo device is a therapeutic device (mechanical insufflation-exsufflation device), not an AI diagnostic imaging tool.

    6. If a standalone (i.e. algorithm only without human-in-the loop performance) was done:

    • Not applicable. This device is a mechanical medical device, not an AI algorithm. While it has software and microcontroller electronics, its "performance" is its mechanical function, regulated by its design parameters and confirmed through physical measurements and standard compliance.

    7. The type of ground truth used:

    • The "ground truth" for this submission is primarily:
      • Engineering Specifications and Design Requirements: The device's internal design parameters for pressure, flow, timing, oscillation, etc.
      • International Standards: Conformance to standards like IEC 60601 series, ISO 18562 series, etc., which define safety and performance benchmarks.
      • Predicate Device Performance: The established, legally marketed performance of the Respironics CoughAssist T70 provides the benchmark for "comparable waveforms" and technological characteristics.

    8. The sample size for the training set:

    • Not applicable. This is not an AI/machine learning device that requires a "training set" of data in the typical sense for algorithm development.

    9. How the ground truth for the training set was established:

    • Not applicable, as there is no "training set" as understood in the context of AI/machine learning.
    Ask a Question

    Ask a specific question about this device

    K Number
    K242935

    Validate with FDA (Live)

    Date Cleared
    2025-01-15

    (112 days)

    Product Code
    Regulation Number
    868.5905
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    China

    Re: K242935

    Trade/Device Name: Respiration Data Management Software Regulation Number: 21 CFR 868.5905
    100073 Beijing, PEOPLE'SREPUBLIC OF CHINA |
    | Classification | Class II Device (21 CFR 868.5905
    |
    | RegulationNumber&ProductCode | 21 CFR 868.5905
    | 21 CFR 868.5905

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Respiration Data Management Software is installed in a computer to perform patient management by treatment data viewing, treatment data reporting and remotely adjusting the prescribed compatible BMC CPAP and BPAP devices' settings. It is intended for healthcare professionals in healthcare facilities use only.

    Device Description

    The Respiration Data Management Software is a softwareonly device, which allows physicians and other clinical staff to transmit, analyze and review respiration data from the compatible CPAP and BPAP devices (non-life support systems), thus to assist the users in patient management and follow-up work. This also includes remote modification of the treatment parameters of the compatible devices. It can also store patient data, upload data to the cloud platform, generate and print reports.

    AI/ML Overview

    The provided text is a 510(k) Summary for the "Respiration Data Management Software." It highlights the device's indications for use and its substantial equivalence to a predicate device, but it does not contain acceptance criteria for device performance or a study demonstrating that the device meets such criteria.

    The document focuses on:

    • Software Verification and Validation: Stating that it was conducted according to FDA guidance.
    • Cybersecurity: Stating that it was considered and evaluated according to FDA guidance.
    • Comparison to Predicate Device: Detailing similarities and differences in functionality, compatible devices, and communication mediums, and asserting that differences do not raise new questions of safety or effectiveness.

    Therefore, I cannot provide the requested information regarding acceptance criteria and a study proving the device meets them because this information is not present in the provided text. The document is a regulatory submission demonstrating substantial equivalence, not a detailed performance study.

    Ask a Question

    Ask a specific question about this device

    K Number
    K243225

    Validate with FDA (Live)

    Date Cleared
    2024-12-31

    (84 days)

    Product Code
    Regulation Number
    868.5905
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :
    • Medium (NNPM-02/ Nefes M); Nasal Pillow Mask - Large (NNPM-03/ Nefes L) Regulation Number: 21 CFR 868.5905
      Nefes L) Common/Usual Name Patient interface for CPAP

    Regulation Name and Product Code

    21 CFR 868.5905

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Nasal Pillow Mask is intended for patients (> 30 kg) who have been prescribed CPAP/VPAP therapy in home, hospital, or institutional environments. This device is intended to be use under the direction of a physician.

    Device Description

    The Nasal Pillow Mask is patient interface device intended for use with CPAP/VPAP therapy systems. The device provides non-invasive means of delivering positive airway pressure to the user by creating a sealed interface using nasal pillows that fit directly into the patients' nostrils. The Nasal Pillow Mask is made of silicone material and comes in 3 different sizes (S, M & L). The nasal mask comes with standard hose fitting intended to be used with standard CPAP/VPAP system. It is intended to be use on patients (> 30 kg) who have been prescribed CPAP/VPAP therapy at home, hospital, or institutional environments. The complete mask set incudes headgear, frame, tube, and nasal pillows (S, M, & L sizes).

    AI/ML Overview

    This document is a 510(k) summary for a Nasal Pillow Mask, indicating that the device is substantially equivalent to a previously cleared predicate device. As such, it highlights the lack of a new study to demonstrate acceptance criteria because the device is deemed identical to its predicate in all relevant aspects.

    Here's the breakdown of why the requested information cannot be fully provided based solely on the input, and what can be extracted:

    1. A table of acceptance criteria and the reported device performance

    The document explicitly states: "The subject device is identical to predicate device except for manufacturer name, brand name, and resulting labeling updates. The indications for use, design, principles of operation, and materials are all identical to the predicate device already cleared by FDA. Therefore, no new non-clinical testing is required."

    This means that for the current 510(k) submission (K243225), no new acceptance criteria or reported device performance data was generated or provided for the subject device. The acceptance criteria and performance data would have been established and demonstrated for the predicate device (K120920) in its original submission.

    The table in the document provides specifications for Deadspace Volume, Resistance, Therapy pressure, Noise level, Environmental Conditions, Weight, and Size Flow, which are common technical specifications for such devices. These are not explicitly stated as "acceptance criteria" but rather as "Specifications" that are "Same" as the predicate.

    Specification ItemSubject Device Performance (Reported as "Same" as Predicate)
    Deadspace VolumeS size: 90.8M size: 94.3L size: 95
    Resistance 50 L/m(Value not numerically given, stated as "Same")
    Resistance 100 L/mS size: 6.87M size: 5.93L size: 5.3
    Therapy pressure5~20cmH2O (Reported as 10cmH2O)
    Noise levelS size: 35.036.0M size: 34.235.6L size: 35.4~36.8
    Environmental ConditionsStorage and Transportation: 15°C ~ 25°C, up to 95% non-condensing Storage relative humidity: <85%
    Weight69.9g
    Size Flow (l/min) @ 5 cmH2OS: 24.94, M: 24.85, L: 25.28
    Size Flow (l/min) @ 10 cmH2OS: 35.66, M: 35.61, L: 35.79
    Size Flow (l/min) @ 15 cmH2OS: 44.76, M: 45.07, L: 44.71
    Size Flow (l/min) @ 20 cmH2OS: 52.46, M: 52.21, L: 51.99

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    • No new sample size or test set was used for the subject device as "no new non-clinical testing is required." Testing relevant to these specifications would have been performed for the predicate device.
    • Data provenance: Not applicable for the subject device's 510(k) as no new studies were conducted. The origin of the predicate device's data is not provided in this document.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    • Not applicable. No expert ground truth establishment was conducted for the subject device's 510(k), as it leveraged the equivalence to a predicate device.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    • Not applicable. No new test set or expert adjudication was performed for the subject device.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • No. This device is a physical medical device (nasal pillow mask), not an AI-powered diagnostic or assistive technology. Therefore, an MRMC study or assessment of AI assistance is irrelevant and was not performed.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    • No. This device is a physical medical device and does not involve an algorithm.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    • Not applicable for the subject device's 510(k). The substantial equivalence determination is based on the device being identical to the predicate in design, materials, and intended use, not on new clinical performance data or ground truth establishment for the subject device. The specifications listed are objective physical measurements.

    8. The sample size for the training set

    • Not applicable. This is a physical medical device, not an AI/machine learning model that requires a training set.

    9. How the ground truth for the training set was established

    • Not applicable. As above, no training set was used.

    In summary of the provided document:

    The 510(k) submission for the Nasal Pillow Mask (K243225) is based on the premise of substantial equivalence to a predicate device (Hsiner Nasal Pillow Mask, K120920). The manufacturer asserts that the subject device is identical to the predicate device in terms of indications for use, design, principles of operation, and materials. Therefore, no new performance studies, acceptance criteria demonstration, or clinical data were generated for the subject device. The FDA's clearance is based on the established safety and effectiveness of the predicate device, which the subject device is claimed to replicate.

    Ask a Question

    Ask a specific question about this device

    K Number
    K241830

    Validate with FDA (Live)

    Date Cleared
    2024-10-18

    (116 days)

    Product Code
    Regulation Number
    868.5905
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Face Vented Mask; Innova Full Face Vented Mask; Ascend Full Face Vented Mask Regulation Number: 21 CFR 868.5905
    |
    | Regulation Number:Regulation Code:Product Code: | 21CFR 868.5905
    Regulation Code:Product Code: | K120463 - Mojo Full Face Mask and Veraseal Full Face Mask21CFR 868.5905
    -------------------------------------------|
    | Product ClassificationCFR | BZDCFR 868.5905
    | BZDCFR 868.5905

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Sleepnet Mojo Full Face Vented Mask, Veraseal 2 Full Face Vented Mask, Innova Full Face Vented Mask and Ascend Full Face Vented Mask are intended to be used with positive airway pressure devices, such as CPAP or bilevel, operating at or above 3 cm H2O. The masks are to be used on adult patients (>30kg) for whom positive airway pressure therapy has been prescribed.

    Mojo is intended for Single patient, multi-use in the home or hospital/institutional environment.

    Veraseal 2 is intended for Short Term Single Patient use (maximum of 7 days) in the hospital institutional environment.

    Innova is intended for Single patient, multi-use in the home or hospital/institutional environment.

    Ascend is intended for Single patient, multi-use in the home or hospital/institutional environment.

    Device Description

    The Sleepnet Mojo Vented Full Face Mask, Veraseal 2 Full Face Vented Mask, Innova Full Face Vented Mask and Ascend Full Face Vented Mask are used with positive pressure devices, such as CPAP and Bi-level.

    The modifications to the cleared Mojo Full Face mask (K120463) are:

    • Addition of contraindication and updated warning related to presence of magnets
    • Change to the headgear material
    • Addition of an XL size

    The modifications to the cleared Veraseal Full Face mask (K120463) are:

    • Modified design, now called the Veraseal 2 Full Face Vented Mask
    • . Addition of an XL size

    Other modifications include:

    • Addition of the Innova Full Face Vented Mask version
    • Addition of the Ascend Full Face Vented Mask version
    AI/ML Overview

    This document does not describe an AI/ML device or a comparative effectiveness study. It is a 510(k) summary for several full face vented masks (Mojo, Veraseal 2, Innova, Ascend) and compares them to a predicate device (Mojo Full Face Mask and Veraseal Full Face Mask, K120463).

    The summary focuses on demonstrating substantial equivalence to a previously cleared device through comparisons of indications for use, patient population, environment of use, and technological characteristics. This typically involves performance testing, biocompatibility, transportation, shelf-life, and reprocessing.

    Therefore, many of the requested elements for an AI/ML device evaluation (e.g., sample size for test/training sets, data provenance, number of experts for ground truth, adjudication method, MRMC study, standalone performance) are not applicable to this document.

    However, I can extract the acceptance criteria and reported device performance from the provided "Table of Comparison to Predicate" and "Non-Clinical Testing Summary" as they relate to these medical masks.


    1. Table of Acceptance Criteria and the Reported Device Performance (as applicable to a physical medical device, not AI/ML):

    Acceptance Criteria (Typically based on ISO 17510 and predicate device performance)Reported Device Performance (Subject Device: Mojo, Veraseal 2, Innova, Ascend Full Face Vented Mask)Predicate Device Performance (K120463: Mojo, Veraseal Full Face Mask)Explanation of Differences (and compliance)
    Exhaust Flow Characteristics: (Comparison to predicate device)Mojo: 3cmH2O: 17.88 lpm, 10cmH2O: 32.57 lpm, 20cmH2O: 48.90 lpm Veraseal 2: 3cmH2O: 22.08 lpm, 10cmH2O: 38.50 lpm, 20cmH2O: 54.30 lpm Innova: 3cmH2O: 22.08 lpm, 10cmH2O: 38.50 lpm, 20cmH2O: 54.30 lpm Ascend: 3cmH2O: 26.80 lpm, 10cmH2O: 41.50 lpm, 20cmH2O: 58.00 lpmMojo: 3cmH2O: 21.20 lpm, 10cmH2O: 37.20 lpm, 20cmH2O: 53.10 lpm Veraseal: 3cmH2O: 21.10 lpm, 10cmH2O: 36.40 lpm, 20cmH2O: 53.00 lpmSimilar. The exhaust flow characteristics of the subject devices are similar to the predicate.
    Anti-Asphyxia Valve (AAV) Opening/Closing Pressure: (< 3 cm H2O as per ISO 17510)Mojo: Opening - 1.10 cm H2O, Closing - 1.60 cm H2O Veraseal: Opening - 2.1 cm H2O, Closing - 2.28 cm H2O Innova: Opening - 2.1 cm H2O, Closing - 2.28 cm H2O Ascend: Opening - 1.92 cm H2O, Closing - 1.85 cm H2OMojo: Opening - 1.10 cm H2O, Closing - 1.60 cm H2O Veraseal: Opening - 1.29 cm H2O, Closing - 1.45 cm H2OSimilar. Pass/Fail criteria as per ISO 17510 is < 3 cm H2O. All subject devices meet the criteria.
    Resistance to Flow (Pressure drop): (No specific acceptance criteria in ISO 17510, values are disclosed)Mojo: 50 lpm: 0.40 cm H2O, 100 lpm: 0.65 cm H2O Veraseal 2: 50 lpm: 0.07 cm H2O, 100 lpm: 0.39 cm H2O Innova: 50 lpm: 0.07 cm H2O, 100 lpm: 0.39 cm H2O Ascend: 50 lpm: 0.11 cm H2O, 100 lpm: 0.59 cm H2OMojo: 50 lpm: 0.40 cm H2O, 100 lpm: 0.65 cm H2O Veraseal: 50 lpm: 0.49 cm H2O, 100 lpm: 0.89 cm H2OSimilar. There are no acceptance criteria in ISO 17510 for resistance to flow (pressure drop). The resistance values are disclosed in the IFUs.
    CO2 Washout Profile (etCO2 % increase vs baseline) - ISO 17510:2015: (Compliance with ISO 17510)Mojo: 3cmH2O: 5.1 (0%), 5cmH2O: 3.5 (-31%), 10cmH2O: 2.1 (-58%), SingleFault1: 7.4 (48%), SingleFault2: 7.5 (51%) Veraseal 2 / Innova: 3cmH2O: 5.9 (16%), 5cmH2O: 5.9 (16%), 10cmH2O: 5.7 (12%), SingleFault1: 6.4 (25%), SingleFault2: 7.4 (45%) Ascend: 3cmH2O: 5.0 (0%), 5cmH2O: 5.0 (0%), 10cmH2O: 4.8 (-4%), SingleFault1: 6.5 (30%), SingleFault2: 7.3 (46%)Mojo and Veraseal: 3cmH2O: 6.1 (17%), 5cmH2O: 5.9 (14%), 10cmH2O: 5.8 (12%), SingleFault1: 6.3 (21%), SingleFault2: Not testedSimilar, complies with ISO 17510. The deadspace for all subject devices is within 5% of the predicate Mojo mask. The CO2 washout profile of all the subject devices has been verified to be adequate.
    Sound Pressure and Sound Power Level: (Comparison to predicate device)Mojo: Sound Pressure – 30.07 dBA, Sound Power – 33.09 dBA Veraseal 2 / Innova / Ascend: Sound Pressure – 29.98 dBA, Sound Power – 32.99 dBAMojo: Sound Pressure – 30.07 dBA, Sound Power – 33.09 dBA Veraseal: Sound Pressure – 29.98 dBA, Sound Power – 32.99 dBAFrom K120463 (Identical values for corresponding models).
    AAV Inspiratory/Expiratory Resistance in Single Fault Condition: (Comparison to predicate device)Mojo®: Inspiratory - 0.8 cm H2O, Expiratory – 0.8 cm H2O Veraseal 2 / Innova / Ascend: Inspiratory - 0.6 cm H2O, Expiratory - 0.5 cm H2OMojo®: Inspiratory - 0.8 cm H2O, Expiratory - 0.8 cm H2O Veraseal: Inspiratory - 0.8 cm H2O, Expiratory - 0.8 cm H2OFrom K120463 (Similar values, meeting functional requirements).
    Internal Volume / Deadspace: (Within 5% of predicate Mojo mask, adequate CO2 washout)Mojo: Small 160 ml, Medium 185 ml, Large 205 ml, XL 210 ml Veraseal 2: Small 155.3 ml, Medium 181.7 ml, Large 196.6 ml, XL 200.6 ml Innova: Small 155.3 ml, Medium 181.7 ml, Large 196.6 ml Ascend: Small 165 ml, Medium 212 ml, Large 221 mlMojo: Small 160 ml, Medium 185 ml, Large 205 ml Veraseal: Small 138 ml, Medium 165 ml, Large 181 mlSimilar. XL size has been added to the Mojo and Veraseal 2 masks. The deadspace for all subject devices is within 5% of the predicate Mojo mask. The CO2 washout profile of all the subject devices has been verified to be adequate.
    Biocompatibility: (Materials identical to cleared predicate devices K120463 and K190254)Materials in gas pathway and skin contact for all subject devices are identical to Sleepnet's own devices cleared under K120463 and K190254.Materials identical to K120463.The biocompatibility test results from the predicate device were leveraged for all subject devices.
    Transportation and Shelf-life: (Leverage predicate device testing)No changes in transportation or shelf-life, leveraging predicate device testing.Predicate device testing results leveraged.The performance post transportation and shelf-life test results from the predicate device were leveraged for the subject device.
    Reprocessing: (Utilize same reprocessing instructions as predicate)Utilizes the same reprocessing instructions as the predicate device.Predicate device reprocessing instructions.The reprocessing test results from the predicate device were leveraged for the subject device.

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    This document describes bench testing for physical device characteristics, not a dataset for an AI/ML model. Therefore, "sample size for the test set" and "data provenance" in the context of clinical data are not applicable. The testing was conducted on samples of the manufactured devices.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    This is not applicable as the study involves physical performance testing of medical masks against engineering standards (like ISO 17510), not expert-based ground truth for clinical interpretation.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    Not applicable for physical device performance testing.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This is a 510(k) submission for physical medical masks, not an AI/ML device or MRMC study.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Not applicable. This is a 510(k) submission for physical medical masks.

    7. The type of ground truth used (expert concensus, pathology, outcomes data, etc)

    The "ground truth" here is the adherence to established international standards (like ISO 17510) and the demonstrated equivalence to a predicate device's performance characteristics through objective bench testing. This is typically measurement-based verification against engineering specifications.

    8. The sample size for the training set

    Not applicable. This document is not about an AI/ML device, so there is no "training set."

    9. How the ground truth for the training set was established

    Not applicable. This document is not about an AI/ML device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K241939

    Validate with FDA (Live)

    Device Name
    EasyCare Tx 2
    Manufacturer
    Date Cleared
    2024-09-27

    (87 days)

    Product Code
    Regulation Number
    868.5905
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    San Diego, California 92123

    Re: K241939

    Trade/Device Name: EasyCare Tx 2 Regulation Number: 21 CFR 868.5905

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Easy Care Tx 2 software is intended to be used with ResMed compatible therapy devices in a clinical environment. EasyCare Tx 2 provides therapy device setting changes and displays real-time data and treatment settings from compatible ResMed therapy devices when used together with the TxLink 2 module.

    Device Description

    EasyCare Tx 2 is a personal computer application designed to allow clinicians to monitor real-time data from the ResMed compatible therapy device and adjust the therapy device settings from the control room of the sleep lab.

    AI/ML Overview

    The device in question is the EasyCare Tx 2, a therapy titration software developed by ResMed Corp. The provided document is a 510(k) Premarket Notification summary to the FDA. The submission seeks to prove substantial equivalence to a predicate device, the EasyCare Tx System (K113780).

    Here's an analysis of the acceptance criteria and study information provided:

    1. Table of Acceptance Criteria and Reported Device Performance

    The document does not explicitly present a table of "acceptance criteria" in a quantitative sense as might be seen for diagnostic device performance (e.g., sensitivity, specificity). Instead, it focuses on comparing the technological characteristics and intended use of the EasyCare Tx 2 with its predicate device to demonstrate substantial equivalence. The "performance" here relates to functional capabilities and parameter ranges rather than diagnostic accuracy.

    Feature/ParameterPredicate Device (EasyCare Tx - K113780)Subject Device (EasyCare Tx 2)Comparison/Performance Notes
    Intended UseTo be used with ResMed compatible therapy devices via Tx Link; provides real-time data and treatment settings display, and can also provide therapy device setting changes remotely; intended for clinical environment.To be used with ResMed compatible therapy devices in a clinical environment; provides therapy device setting changes and displays real-time data and treatment settings from compatible ResMed therapy devices when used together with TxLink 2 module.Similar.
    Technological Characteristics
    Prescription UseYesYesSame.
    Intended Environment of UseHospital or Sleep LabHospital or Sleep LabSame.
    Display TypePCPCSame.
    Hardware RequirementsStandard PC platform with microprocessor and ancillary controllersStandard PC platform with microprocessor and ancillary controllersSame.
    Operating SystemMicrosoft WindowsMicrosoft WindowsSame.
    AccessoriesCD for downloading to PC, Tx LinkCD for downloading to PC, Tx Link 2Similar (Tx Link vs. Tx Link 2).
    Compatible Therapy DevicesBZD, MNS, MNTBZDSimilar. EasyCare Tx 2 does not support product codes MNS and MNT.
    Therapy Device Adjustments (Settings)
    Adjust Device Therapy ModeYesYesSame.
    Adjust Device Therapy SettingsYesYesSame.
    Available Therapy ModesCPAP, AutoSet, AutoSet for Her, S, ST, TVAuto, ASV, ASVAuto, PAC, iVAPSCPAP, AutoSet, AutoSet for Her, S, ST, TVAuto, ASV, ASVAuto, PACThe PAC and iVAPS modes are no longer used and supported as they are for devices under MNS and MNT product codes, and not in scope for EasyCare Tx 2 with BZD devices.
    Humidifier ControlHumidifier on/offHumidifier on/off, level control, autoSimilar. Auto mode added for the attached therapy device optimizes humidifier temperature. EasyCare Tx 2 controls humidifier settings.
    Tubing ControlTube Temperature on/off, autoTube Temperature on/off, autoSame. Therapy device optimizes tube temperature.
    Ramp0 to 45 min5 to 45 min, off, autoSimilar. Off mode added for usability. Auto mode stops ramp when sleep detected.
    Output Parameters
    Pressure-3 to 35 cm H2O0 to 30 cm H2OSimilar. Therapy for EasyCare Tx 2 only supports OSA devices requiring lower pressure, removing the -3 cm H2O which was for a niche case in older devices. The therapy range has not changed for the relevant BZD devices.
    Flow-120 to 120 L/min-240 to 240 L/minSimilar. Increased range due to larger data model and scalable architecture. Risks are considered by the parent therapy device.
    Leak-30 to 120 L/min0 to 2 L/sSimilar. Leak parameters are sent from the attached therapy device in L/s. EasyCare Tx 2 allows toggling between L/s and L/min.
    Respiratory Rate6 to 35 BPM0 to 90 BPMSimilar. Higher range supports pediatric patients using AirSense 11.
    Tidal Volume0.01 to 3 L0 to 4 LSimilar.
    Target Ventilation0 to 30 L/min0 to 30 L/minSame.
    Minute Ventilation0 to 30 L/min0 to 30 L/minSame.
    Ti (Inspiration Time)0 to 9 seconds0.3 to 4 secondsSimilar.
    Pulse Rate18 to 300 BPM0 to 300 BPMSimilar. Expansion of range due to new sensor supporting increased data monitoring.
    SpO₂40 to 100%0 to 100%Similar. Expansion of range due to new sensor supporting increased data monitoring.

    The acceptance criteria here are implicitly met by demonstrating that the EasyCare Tx 2 has similar intended use and technological characteristics to the predicate device, and that any differences do not raise new questions of safety or effectiveness. The "reported device performance" are the parameter ranges and functional capabilities described for EasyCare Tx 2.

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    The document states: "Non-clinical verification and validation testing completed for EasyCare Tx 2 demonstrated that the device met all intended performance requirements. Testing included: Software verification and validation."

    It also mentions: "The verification testing performed with EasyCare Tx 2 was software verification and validation against the non-functional requirements and end-to-end functional testing."

    This indicates that the "test set" consisted of various software testing scenarios (unit, integration, system, performance, usability tests) to verify functionality and non-functional requirements. However, no specific sample size (e.g., number of data points, cases, or patients) for a test set is provided, nor is the data provenance (country of origin, retrospective/prospective) for any specific clinical data mentioned. The testing described is primarily software-centric, not based on a dataset of patient outcomes.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g., radiologist with 10 years of experience)

    This information is not provided. The testing described is software verification and validation, which typically involves engineering and quality assurance professionals, not clinical experts establishing ground truth in the context of medical image analysis or similar diagnostic tasks.

    4. Adjudication method (e.g., 2+1, 3+1, none) for the test set

    This information is not provided. Given the nature of the software verification and validation, adjudication methods typical for clinical or image-based studies are not relevant here.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    No MRMC comparative effectiveness study was done. This device is a software application for clinicians to monitor and adjust therapy device settings, not a diagnostic AI intended to assist human readers.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    The device is a human-in-the-loop software. Its purpose is to allow clinicians to monitor and adjust therapy settings. The "performance" is the software correctly displaying data and applying setting changes, not standalone diagnostic accuracy. The testing performed was "software verification and validation against the non-functional requirements and end-to-end functional testing," indicating validation of its functional integrity, not standalone diagnostic capability.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    For the software verification and validation, the "ground truth" would be the defined software requirements and expected behavior based on engineering specifications and design documents. For example, if a setting is changed from X to Y, the ground truth is that the software should correctly register and apply that change to the therapy device and display it accurately. It's not a clinical ground truth like pathology or outcome data.

    8. The sample size for the training set

    This information is not applicable/not provided. The EasyCare Tx 2 is described as therapy titration software, not an AI/ML model that would require a "training set" in the context of learning from data to make predictions or classifications. The software's functionality is based on programming and engineering, not machine learning.

    9. How the ground truth for the training set was established

    This information is not applicable/not provided as there is no mention of a machine learning training set.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 42