510(k) Data Aggregation

    K Number
    K212563

    Validate with FDA (Live)

    Date Cleared
    2022-05-23

    (283 days)

    Product Code
    Regulation Number
    872.3820
    Panel
    Dental
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K893794, K042769, K063237, K140247, K200175, K190510

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    CalApex is a calcium hydroxide, polymeric resin, root canal filling material that is used in conjunction with gutta percha or silver endodontic points.

    Calplus is a temporary or permanent root canal filling material for use following pulpectomy, or for apexogenesis or apexification.

    Cerafill RCS is a MTA (mineral trioxide aggregate) based root canal sealer that provides complete and permanent sealing of root canals. It can be used with or without root canal obturation materials.

    Endoseal is used for permanent obturation of the root canal space with the aid of obturating points in accordance with ISO 6876 for Dental Root Canal Sealing materials.

    Nanoseal S is indicated in patients for permanent obturations of root canal after vital extirpation or after treatment of pulpal gangrene and temporary filling.

    Zical Ultra Paste is used for permanent obturation of the root canal space with the aid of obturating points.

    Zical Ultra Powder/Liquid is used for permanent obturation of the root canal space with the aid of obturating points.

    Device Description

    CalApex is a non-eugenol, radiopaque, calcium hydroxide polymeric resin root canal filling material. It is a two part, base/catalyst – paste/paste system that is mixed in equal portions. The mixture is then carried to the root canal with endodontic obturation points or directly dispensed in the root canal depending on delivery method, e.g. tube or dual-barrel syringe.

    Calplus can be used as a temporary or permanent root canal filling material.

    Cerafill RCS is an endodontic sealer based on MTA, providing a biocompatible and effective root canal filling. It is premixed and pre-loaded in a syringe, which allows a complete filling of the entire root canal including accessory and lateral canals. The product is eugenol-free and will not impede adhesion inside the root canal.

    Endoseal is a Zinc Oxide/Eugenol root canal sealant. The product is made up of two separate components, a powder base and a liquid catalyst, to form the final device.

    Nanoseal S is a permanent root canal filling material which is silicone based (polydimethylsiloxane). It is cold flowable and is in a dual barrel cartridge.

    Zical Ultra Paste is a two-part, base/accelerator, paste/paste system that is mixed in equal portions. The mixture is carried to the root canal with endodontic obturation points. The product comes in a dual barrel cartridge.

    Zical Ultra Powder/Liquid is a two-part, powder/liquid system for permanent filling of root canals. The mixture is carried to the root canal with endodontic obturation points.

    AI/ML Overview

    The document describes the acceptance criteria and performance of several root canal sealers developed by Prevest Denpro Limited. The study involved a series of bench tests conducted according to ISO standards to demonstrate substantial equivalence to predicate devices.

    1. Table of Acceptance Criteria and Reported Device Performance:

    Test ParameterAcceptance Criteria (ISO Standard & Specific Values)Reported Device Performance (Summary for all tested sealers)
    AppearancePass/Fail (based on acceptable appearance)All passed
    FlowBased on ISO 6876:2012, Section 5.2
    - CalApex, Cerafill RCS, Endoseal, Nanoseal S, Zical Ultra Paste, Zical Ultra Powder/LiquidNot less than 17mm> 17mm
    - Calplus25-28mm25-28mm
    Film ThicknessISO 6876:2012, Section 5.5, not more than 50µm<50µm
    Water SolubilityISO 6876:2012, Section 5.6, not more than 3% by massCalApex: 1.31%, Cerafill RCS: 1.61%, Endoseal: 1.09%, Nanoseal S: 1.06%, Zical Ultra Paste: 1.31%, Zical Ultra Powder/Liquid: 0.75% (All within <3% limit)
    Working TimeBased on ISO 6876:2012, Section 5.3
    - CalApex16-18min16-18min
    - Cerafill RCS, Endoseal, Zical Ultra Paste, Zical Ultra Powder/Liquid25-30min25-30min
    - Nanoseal S8-10min8-10min
    Setting TimeBased on ISO 6876:2012, Section 5.4
    - CalApex20-40min20-40min
    - Cerafill RCS24 hoursWithin 24 hours
    - Endoseal, Zical Ultra Paste, Zical Ultra Powder/Liquid45-60min45-60min
    - Nanoseal S10-15min10-15min
    DisintegrationISO 6876:2012, Section 4.3.5, no evidence of disintegrationNo evidence of disintegration (All passed)
    Radio-opacityISO 13116:2014, above or equal to 3 mm Al6 mm Al (All tested sealers, which is above 3mm Al)
    BiocompatibilityAssessment according to ISO 10993Yes (assessment provided for all subject devices)
    Shelf LifeSame as bench testing pass criteria (ISO 6876:2012)CalApex: 2 years, Others: 3 years (All met criteria)

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective):

    The document does not specify the exact sample sizes used for each bench test. It states that the tests were conducted "according to protocols based on ISO 6876:2012 and tested for radio-opacity according to a protocol based on ISO 13116:2014". The data provenance is implied to be from the manufacturer's testing, but no specific country of origin for the data or whether it was retrospective or prospective is mentioned. The manufacturer, Prevest Denpro Limited, is located in India.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience):

    This type of information is not applicable to this study. The tests performed are benchtop physical and chemical property evaluations rather than evaluations requiring expert human interpretation of medical images or patient outcomes. The "ground truth" for these tests is defined by the objective measurement protocols and acceptance criteria of the specified ISO standards.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set:

    Not applicable. The study involves objective bench testing, not subjective assessments requiring adjudication by multiple experts.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    Not applicable. This study focuses on the physical and chemical properties of root canal sealers and does not involve AI or human readers for diagnostic interpretation.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

    Not applicable. This study does not involve an algorithm or AI.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc):

    The ground truth for this study is defined by the objective measurement standards and acceptance criteria set forth by international ISO standards (ISO 6876:2012 for most physical properties and ISO 13116:2014 for radio-opacity). For biocompatibility, the ground truth is established by the assessment according to ISO 10993.

    8. The sample size for the training set:

    Not applicable. This study involves bench testing of medical devices, not training of machine learning models.

    9. How the ground truth for the training set was established:

    Not applicable. There is no training set for this type of device submission.

    Ask a Question

    Ask a specific question about this device

    K Number
    K172701

    Validate with FDA (Live)

    Device Name
    BIO-C SEALER
    Date Cleared
    2018-01-04

    (119 days)

    Product Code
    Regulation Number
    872.3820
    Panel
    Dental
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K140247, K151047

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
      1. Sealing the root canal of permanent teeth;
      1. Internal reabsorption treatment.
    Device Description

    BIO-C SEALER is a ready-to-use injectable endodontic bioceramic sealer, suitable for obturation of root canals.

    AI/ML Overview

    The provided text describes a 510(k) premarket notification for a dental device called BIO-C SEALER. This type of submission focuses on demonstrating substantial equivalence to a legally marketed predicate device rather than providing clinical efficacy studies with specific acceptance criteria as might be found for a novel device or drug.

    Therefore, the supplied text does not contain the information requested regarding:

    • A table of acceptance criteria and reported device performance in a clinical context. The performance data is for physical-chemical properties to show equivalence to the predicate.
    • Sample size used for a test set (clinical data).
    • Data provenance for a test set (clinical data).
    • Number of experts used to establish ground truth or their qualifications.
    • Adjudication method for a test set.
    • Multi-reader multi-case (MRMC) comparative effectiveness study.
    • Standalone performance (algorithm only without human-in-the-loop performance).
    • Type of ground truth used (expert consensus, pathology, outcomes data, etc.) for clinical efficacy.
    • Sample size for a training set (clinical data).
    • How ground truth for the training set was established (clinical data).

    Instead, the document highlights non-clinical (bench) testing to support substantial equivalence.

    Here's what can be extracted from the document regarding "performance criteria" in the context of a 510(k) and the "study" (bench tests) that proves them:

    1. A table of acceptance criteria and the reported device performance

    The document states: "BIO-C SEALER has undergone extensive bench testing to provide evidence that its physical-chemical properties are substantially equivalent to iRoot SP. Bench tests performed are: flow, setting time, film thickness, solubility and radiopacity. Both devices have comparable flowability, setting time, film thickness, solubility and radiopacity."

    This implies that the acceptance criteria for BIO-C SEALER's physical-chemical properties were to demonstrate comparability or substantial equivalence to the predicate device (iRoot SP) for these specific metrics. The reported performance is that they are comparable.

    Acceptance Criteria (Implicit)Reported Device Performance (BIO-C SEALER)
    Flow: Comparable to iRoot SPAchieved comparability
    Setting Time: Comparable to iRoot SPAchieved comparability
    Film Thickness: Comparable to iRoot SPAchieved comparability
    Solubility: Comparable to iRoot SPAchieved comparability
    Radiopacity: Comparable to iRoot SPAchieved comparability
    Biocompatibility: Non-mutagenic, does not cause allergenic potential, good tolerance.Achieved (product is non-mutagenic, does not cause an allergenic potential after multiple uses and has a good tolerance)

    2. Sample sized used for the test set and the data provenance

    • Sample size: Not specified. The document only mentions "extensive bench testing." The sample size would refer to the number of samples of the material tested for each physical-chemical property.
    • Data provenance: Bench test results; conducted by Angelus Indústria de Produtos Odontológicos S/A. It's non-clinical, so country of origin for patients/data is not relevant.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    Not applicable. This was bench testing of physical properties, not a clinical study requiring expert ground truth.

    4. Adjudication method for the test set

    Not applicable. This was bench testing.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This is a dental material, not an AI diagnostic device.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Not applicable. This is a dental material, not an AI algorithm.

    7. The type of ground truth used

    For physical-chemical properties, the "ground truth" is measured by standard laboratory methods according to relevant ISO or ASTM standards, against which the test device's performance is compared to the predicate device's established performance or regulatory requirements. For biocompatibility, the ground truth would be established by validated tests for mutagenicity, allergenicity, and general tolerance.

    8. The sample size for the training set

    Not applicable. This device does not use machine learning or require a training set.

    9. How the ground truth for the training set was established

    Not applicable. This device does not use machine learning or require a training set.