510(k) Data Aggregation

    K Number
    K200988

    Validate with FDA (Live)

    Device Name
    Maximus System
    Date Cleared
    2020-05-26

    (41 days)

    Product Code
    Regulation Number
    868.5905
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K991725,K142888

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Maximus™ System provides features of both the Synclara™ System and the Volara™ System.

    The Maximus™ System, when used as a Synclara™ Cough System is intended for use on patients who are unable to cough or clear secretions effectively due to reduced peak cough expiratory flow or respiratory muscle weakness.

    The Maximus™ System, when used as a Volara™ System is intended for the mobilization of secretions, lung expansion therapy, the treatment and prevention of pulmonary atelectasis, and has the ability to provide supplemental oxygen when used with oxygen supply.

    Device Description

    The Maximus™ System is a 2 in 1 device which combines 2 main types of therapies referred to as:

    • MIE (Mechanical Insufflation-Exsufflation) Synclara®
    • OLE (Oscillation and Lung Expansion) - Volara™

    The modification is to add the ability to provide aerosol from the nebulizer via the Ventilator Tee adaptor during Continuous High Frequency Oscillations (CHFO) mode when connected to a ventilator. All components were cleared under K192143.

    AI/ML Overview

    The provided text describes a 510(k) premarket notification for the Maximus™ System, a noncontinuous ventilator. The submission is for a modification to an already cleared device (K192143) to add the ability to provide aerosol from the nebulizer via a Ventilator Tee adapter during Continuous High Frequency Oscillations (CHFO) mode when connected to a ventilator.

    Here's an analysis of the acceptance criteria and study information provided:

    1. Table of Acceptance Criteria and Reported Device Performance

    The acceptance criteria are implied by the comparative testing conducted, aiming to demonstrate equivalence to the predicate device. The performance metrics reported are related to aerosol delivery, specifically Mass Median Aerodynamic Diameter (MMAD), Total Respirable Dose, and Fine Particle. The acceptance criteria for these metrics were that they should be "equivalent" across different patient interfaces.

    Acceptance Criteria (Implied)Reported Device Performance
    Aerosol delivery parameters (MMAD, Total Respirable Dose, Fine Particle) for the new Ventilator Tee Adaptor should be equivalent to those of already cleared patient interfaces (Mouthpiece, Face Mask)."Testing parameters included the key particle parameters, Mass Median Aerodynamic Diameter (MMAD), Total Respirable Dose and Fine Particle, are equivalent. The comparative testing supports that the different patient interfaces are not significantly different in their delivery of aerosol."
    No new or different questions of safety or effectiveness are raised by the modification."The differences presented above have not raised new or different questions of safety or effectiveness from the predicate."

    2. Sample Size Used for the Test Set and Data Provenance

    • Sample Size for Test Set: Not explicitly stated as a number of devices or clinical cases. The testing was described as "comparative particle characterization testing comparing the following patient interfaces: Mouthpiece, Face Mask (already cleared under K192143) and delivery through the already cleared Ventilator Tee Adaptor." It was performed at "Adult flow rates (28 Lpm) and Pediatric flow rates (12 Lpm) with 1 drug at the lowest and highest set pressures (5 and 70 cmH2O)." This indicates bench testing rather than patient data.
    • Data Provenance: The data is from bench testing performed by the manufacturer, Hill-Rom Services Pte Ltd. There is no mention of country of origin for the data or if it was retrospective or prospective, as it is not human subject data.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Their Qualifications

    Not applicable. The ground truth for this submission is based on objective measurements from bench testing of aerosol delivery parameters, not expert human assessment.

    4. Adjudication Method for the Test Set

    Not applicable, as the evaluation is based on objective measurements from bench testing.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    No. This submission describes a modification to a medical device (ventilator) and involves bench testing of its physical performance (aerosol delivery), not a diagnostic algorithm or human interpretation task. Therefore, an MRMC study is not relevant.

    6. Standalone (Algorithm Only) Performance Study

    No. This is a physical device, and the testing focuses on its mechanical and delivery performance. There is no AI or algorithm involved in the direct clinical function being evaluated.

    7. Type of Ground Truth Used

    The ground truth is established through objective physical measurements of aerosol particle characteristics (MMAD, Total Respirable Dose, Fine Particle) using standardized test methods.

    8. Sample Size for the Training Set

    Not applicable. This device does not involve a machine learning algorithm that requires a training set.

    9. How the Ground Truth for the Training Set Was Established

    Not applicable. As there is no training set for a machine learning algorithm, there is no ground truth to establish for it.

    Ask a Question

    Ask a specific question about this device

    K Number
    K072163

    Validate with FDA (Live)

    Date Cleared
    2008-03-06

    (213 days)

    Product Code
    Regulation Number
    868.5630
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K870027, K991725, K963924

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The intended use of the Happyneb II. Happyneb III. Speedy, Nebby Plus and the Myneb is to spray liquids in aerosol form into gases that are delivered directly to adult or pediatric patients who have been prescribed inhalation therapy or medication. Each of these devices must be used exclusively with their own nebulizer and mouthpiece.

    The devices Happyneb II, Happyneb III, Speedy, and the Nebby Plus are intended to be used primarily by patients in the home care market, although they may also be used by trained hospital staff personnel as well. The Myneb model is intended to be used only in home health care.

    The Happyneb II, Happyneb III. Speedy, Nebby Plus and the Myneb are intended for multiple use, are non-sterile and for use with pharmaceutical products which are under physician prescription.

    Device Description

    The family of 3A Health Care nebulizers include 5 different devices: 4 are AC powered devices (Happyneb II, Happyneb III, Speedy, Nebby Plus) and one model (Myneb) with a DC motor, a rechargeable battery pack and an external charger/power supplier.

    The 4 AC compressors (Happyneb II, Happyneb III, Speedy, and Nebby Plus) have different plastic housings. There are three different types of electrical motors for AC models and one type for the DC model (Myneb). The 5 models of compressors are designed to use two nebulizers, the Fasterjet and Nebjet.

    AI/ML Overview

    The provided text is for a 510(k) Summary for nebulizers. Nebulizers are medical devices used to deliver medication to the respiratory system. The submission focuses on demonstrating substantial equivalence to predicate devices based on performance bench tests, not on diagnostic accuracy or clinical outcomes as would be typical for many AI-powered medical devices. Therefore, many of the requested categories related to AI performance, expert review, and clinical studies are not applicable or not detailed in this document.

    Here's an analysis based on the provided text:

    Acceptance Criteria and Study to Prove Device Meets Acceptance Criteria

    The acceptance criteria for these nebulizers are based on demonstrating equivalent performance parameters to legally marketed predicate devices through non-clinical bench tests. The study performed aimed to show this equivalency.

    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance Criteria CategorySpecific Acceptance Criteria (Equivalent to predicate devices)Reported Device Performance (as demonstrated by tests)
    Aerosol Particle SizeEquivalent Mass Median Aerodynamic Diameter (MMAD) to predicate devicesDemonstrated equivalent MMAD
    Particle Size DistributionEquivalent Geometric Standard Deviation (GSD) to predicate devicesDemonstrated equivalent GSD
    Fine Particle FractionEquivalent Fine Particle Fraction (FPF) to predicate devicesDemonstrated equivalent FPF
    Fine Particle DoseEquivalent Fine Particle Dose (PFD) to predicate devicesDemonstrated equivalent PFD
    Clinical EfficacyClinical data not required due to demonstrated equivalent performance parameters to predicate devices.(No clinical data presented)

    2. Sample Size Used for the Test Set and Data Provenance

    The document does not specify a "sample size" in the context of patients or data points, as the testing was non-clinical performance bench tests. The data provenance is from 3A Health Care Srl, the submitter, and the tests were executed as requested in the "Reviewer guidance for nebulizers, metered dose inhalers, spacers and actuators" issued in October 1993. These were prospective bench tests conducted on the newly designed nebulizer models.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts

    Not applicable. This was a non-clinical bench test study evaluating physical performance parameters of a medical device, not a diagnostic or AI-powered system that requires expert interpretation to establish ground truth.

    4. Adjudication Method for the Test Set

    Not applicable. As stated above, this was a bench test, not a study requiring adjudication of expert opinions or interpretations.

    5. If a Multi Reader Multi Case (MRMC) Comparative Effectiveness Study was Done

    No. This was not an MRMC study. The comparison was device-to-device (new nebulizer models to predicate nebulizer models) based on physical performance parameters, not an evaluation of human reader performance with or without AI assistance.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) was Done

    Not applicable. This device is a nebulizer, not an algorithm or AI system.

    7. The Type of Ground Truth Used

    The "ground truth" in this context refers to the established performance benchmarks and specifications for nebulizer characteristics (MMAD, GSD, FPF, PFD) as defined by regulatory guidance and demonstrated by legally marketed predicate devices. The new devices' performance was measured and compared against these established physical and functional parameters.

    8. The Sample Size for the Training Set

    Not applicable. This document describes a medical device, not an AI model, and therefore there is no concept of a "training set" for an algorithm.

    9. How the Ground Truth for the Training Set Was Established

    Not applicable. As there is no training set, this question is not relevant to the provided document.