510(k) Data Aggregation

    K Number
    K073415

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2008-05-23

    (171 days)

    Product Code
    Regulation Number
    890.1375
    Reference & Predicate Devices
    Why did this record match?
    Reference Devices :

    K922488, K981405

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    NEMUS systems are diagnostic medical systems able to detect the electric signals produced by the peripheral nerve system and by skeletal muscles.

    The NEMUS system is intended to monitor, record and display the bioelectric signal produced by the muscles, to stimulate peripheral nerves, and to monitor, record and display the electrical activity produced by nerves to aid the clinician in the diagnosis and prognosis of neuromuscular diseases (EMG). The device may use electrical stimulus or sound stimulus for use in evoked response measurements (EP).

    Device Description

    There are two configurations of NeMus: NeMus System and NeMus PC Peripheral.

    The "Nemus system" is a complete system provided with a cart (expressly designed for this device and equipped with isolation transformer, the base unit support mobile arm, places for computer, keyboard, footswitch, printer, and dedicated keyboard and so on. The complete system provided of all the part ordered by the customer is completely wired, assembled and tested in factory before to ship to the final user. Like the hardware parts, all the needed software is installed and configured in factory.

    The "Nemus PC Peripheral" is a base kit (constituted by the NeMus 1 Amplifier the AC/DC adapter, cables and GALILEO NT management software) which, by adding a Personal Computer, becomes a digital electromiograph system. This configuration is developed and verified in order to allow a Distributor or the User to "build" an acquisition/processing EMG signal system by using the NeMus 1 acquisition module, the GALILEO NT/MYTOWIN management software and their own Personal Computer (and peripherals). However the PC must be compliant with EBNeuro specified minimum requirements. Of course the "system builder" must follow all the indications detailed in the related User Manual provided with the system. In this kind of system configuration, the "base kit" provided by EBNeuro is a sort of "peripheral" of a PC system. This configuration allows the Distributor or the User to use its own PC, cart or other "system" arrangement of its choice.

    NeMus systems are diagnostic medical systems able to detect the electric signals produced by the peripheral nerve system and by skeletal muscles.

    The Nemus system is intended to monitor, record and display the bioelectric signal produced by the muscles, to stimulate peripheral nerves, and to monitor, record and display the electrical activity produced by nerves to aid the clinician in the diagnosis of neuromuscular diseases (EMG). The device may use electrical stimulus or sound stimulus for use in evoked response measurements (EP).

    AI/ML Overview

    The provided text is a 510(k) summary for the Nemus System and Nemus PC Peripheral, which are electromyographs. This summary primarily focuses on establishing substantial equivalence to predicate devices and describes the device's technical characteristics and intended use.

    Crucially, this document does NOT contain information about specific acceptance criteria or a study designed to prove the device meets those criteria, as typically found in clinical validation studies. The information provided is for regulatory clearance based on substantial equivalence to existing devices, not a de novo clinical performance study against pre-defined performance metrics.

    Therefore, many of the requested points cannot be answered from the provided text. I will indicate where the information is not available.


    Acceptance Criteria and Device Performance (Not applicable directly from the provided text):

    The document does not specify quantitative acceptance criteria for device performance (e.g., sensitivity, specificity, accuracy, or specific thresholds for physiological signal capture). Instead, it relies on demonstrating that the device has similar technological characteristics to its predicate devices, implying comparable performance.

    The table below summarizes some key performance characteristics from the provided comparison table, but these are typically specifications, not acceptance criteria against which a clinical study would be measured in this context.

    Product Characteristic (Performance-Related)Acceptance Criteria (Not Explicitly Stated as such in the document)Reported Device Performance (Nemus System)
    Acquisition
    CMRR (Common Mode Rejection Ratio)Comparable to predicate (>100 dB for PHASIS, >110 dB for Sinergy LT)>100 dB
    NoiseComparable to predicate (<0.9 µVrms for PHASIS, <0.7 µVrms for Sinergy LT)<0.3 µVrms (0.1 - 00 Hz), < 20 nV/Hz^1/2 (10 Hz - 10 kHz )
    Input impedanceComparable to predicate (>100 MOhm for PHASIS, >1000 MOhm for Sinergy LT)> 1000 MOhm / 8 pF
    A/D conversionComparable to predicate (16 bit for both predicates)24 bit Sigma-Delta
    Sampling rateComparable to predicate (0.5 µs max for PHASIS, 50 kHz for Sinergy LT)4.194 MHz
    Ohmmeter rangeComparable to predicate (0-100 kOhm for PHASIS, 0-32 kOhm for Sinergy LT)0-100 kOhm (auto full scale)
    Stimulators
    Max output (Somatosensory Elec. Stimulator)Comparable to predicate (100 mA for both predicates)100 mA
    Pulse width (Somatosensory Elec. Stimulator)Comparable to predicate (0.01-1 ms for PHASIS, 0.05-1 ms for Sinergy LT)0.05 - 1 ms
    Sound pressure (Audio Stimulator)Comparable to predicate (20-132 dB SPL for PHASIS, 0-122 dB SPL for Sinergy LT)0-132 dB SPL

    1. A table of acceptance criteria and the reported device performance:

    As mentioned above, the 510(k) summary does not define specific "acceptance criteria" in the way one might expect for a clinical performance study. Instead, the "performance" is presented as technical specifications and compared to predicate devices for the purpose of demonstrating substantial equivalence. The table above provides the most relevant performance characteristics available.


    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective):

    Not Applicable. The provided document is a 510(k) summary for regulatory clearance based on substantial equivalence. It does not describe a clinical performance study with a test set of patient data. The "testing" involved appears to be related to engineering specifications and safety standards (e.g., IEC 60601-1).


    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience):

    Not Applicable. No ground truth establishment is described, as there is no mention of a clinical test set or human interpretation being evaluated.


    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set:

    Not Applicable. No adjudication method is described, as there is no mention of a clinical test set or human interpretation being evaluated.


    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    Not Applicable. This document pre-dates widespread AI integration in medical devices (2008) and does not describe any MRMC studies or AI assistance features. It is purely an electromyograph device.


    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

    Not Applicable. This device is an electromyograph, which assists clinicians in diagnosis, but it is not an AI algorithm performing diagnostic tasks in a standalone capacity. Its performance is measured by its ability to accurately acquire and display bioelectric signals.


    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

    Not Applicable. No ground truth is described, as the document focuses on the device's technical specifications and substantial equivalence, not a clinical validation study against a pre-defined diagnostic gold standard.


    8. The sample size for the training set:

    Not Applicable. There is no mention of a training set, as the device is not based on machine learning or AI that would require such data.


    9. How the ground truth for the training set was established:

    Not Applicable. No training set is mentioned in the document.

    Ask a Question

    Ask a specific question about this device

    K Number
    K061828

    Validate with FDA (Live)

    Date Cleared
    2007-08-24

    (422 days)

    Product Code
    Regulation Number
    882.5890
    Predicate For
    N/A
    Why did this record match?
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Aptiva™ v2.13U is a multifunctional transcutaneous electrical nerve stimulator (TENS) equipped with a surface electromyography and electroneurography.

    Aptiva™ is indicated for symptomatic relief and management of chronic pain, intractable pain and/or as an adjunctive treatment for the management of post-traumatic pain.

    The dynamic surface electromyography and electroneurography system is used for biofeedback, relaxation training, and muscle re-education as well as monitoring and display of bioelectric signals produced by muscles, stimulate peripheral nerves, and monitor and display the electrical activity produced by nerves.

    Device Description

    The Aptiva™ v2.13U consists of a console on a mobile floor stand, power cord, battery charger, patient remote control, cables, and Manuals (User and Application). The Aptiva™ v2.13U is provided in four functional models (Ballet, Flamenco, Hip-Hop, and Jazz). EMG features are provided in the Ballet and Hip Hop models. One version of the Ballet model (Option Etoile) includes electroneurography (ENG) functions and a printer. Aptiva™ v2.13U uses commercially available electrodes. Models designated "Light" versions do not include the full treatment databases.

    AI/ML Overview

    The provided text describes a 510(k) summary for the Lorenz Biotech Aptiva™ v2.13U device. This document focuses on demonstrating substantial equivalence to predicate devices and detailing the device's intended use and technological characteristics.

    Regarding your request for acceptance criteria and a study proving the device meets them, the provided text does NOT contain information about specific performance acceptance criteria for diagnostic accuracy, sensitivity, specificity, or other clinical performance metrics, nor does it detail a study that evaluates these metrics in a clinical context.

    Instead, the "PERFORMANCE TESTING" section states: "Testing included in this premarket notification includes electrical safety, electromagnetic compatibility, and design verification and validation testing. No materials of the Aptiva™ v2.13U are in direct contact with treatment sites and therefore no biocompatibility testing was provided. Test results demonstrate that the Aptiva™ v2.13U fulfills the prospectively defined performance specifications."

    This indicates that the performance testing focused on engineering and safety specifications, not clinical efficacy or diagnostic accuracy as would be assessed in a study with a test set, ground truth, and expert readers. The 510(k) process for this type of device often relies on demonstrating substantial equivalence to legally marketed predicate devices based on technological characteristics and intended use, rather than conducting new clinical effectiveness studies for each submission.

    Therefore, I cannot fulfill most of your request based on the provided text.

    Here's what I can provide based on the information given, and where most of your requested points cannot be answered:


    1. A table of acceptance criteria and the reported device performance

    Acceptance Criteria TypeReported Device Performance/Testing
    Clinical Performance (e.g., diagnostic accuracy, sensitivity, specificity)Not reported. The document does not provide clinical performance metrics. The submission focuses on substantial equivalence based on intended use, indications for use, operational characteristics, and fundamental technological characteristics, and safety/engineering testing.
    Electrical Safety"Test results demonstrate that the Aptiva™ v2.13U fulfills the prospectively defined performance specifications." (Specific criteria and results not detailed in the summary.)
    Electromagnetic Compatibility"Test results demonstrate that the Aptiva™ v2.13U fulfills the prospectively defined performance specifications." (Specific criteria and results not detailed in the summary.)
    Design Verification & Validation"Test results demonstrate that the Aptiva™ v2.13U fulfills the prospectively defined performance specifications." (Specific criteria and results not detailed in the summary. This likely refers to engineering design and functional testing against internal specifications, not clinical performance.)
    Biocompatibility"No biocompatibility testing was provided." (Justified by no direct patient contact with materials.)

    The following information cannot be provided as it is not present in the given text:

    1. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)
    2. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)
    3. Adjudication method (e.g. 2+1, 3+1, none) for the test set
    4. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance
    5. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done
    6. The type of ground truth used (expert concensus, pathology, outcomes data, etc)
    7. The sample size for the training set
    8. How the ground truth for the training set was established

    The Aptiva™ v2.13U is a Transcutaneous Electrical Nerve Stimulator (TENS) and EMG/ENG device, which are typically cleared through 510(k) based on established safety and performance standards for electrical devices and substantial equivalence, rather than extensive clinical studies for diagnostic accuracy that would involve a "test set" and "ground truth" in the way described for, for example, an AI imaging device.