510(k) Data Aggregation

    K Number
    K063494

    Validate with FDA (Live)

    Date Cleared
    2007-05-21

    (182 days)

    Product Code
    Regulation Number
    882.4460
    Age Range
    All
    Reference & Predicate Devices
    Why did this record match?
    Reference Devices :

    K051501xc, K013979, K970541

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Radiolucent / MRI Compatible Skull Clamp Headrest System with Skull Pins are components of a mechanical support system which is used in head and neck surgery when rigid skeletal fixation is required for cranial stabilization and when intra-operative CT or MR Imaging is used.

    The DORO® Radiolucent / MRI Compatible Horseshoe Headrest System are components of a mechanical support system which is used in head and neck surgery when non-invasive head support is required and when intra-operative CT or MR Imaging is used.

    The DORO® Radiolucent / MRI Compatible Halo System is a system of radiolucent halo rings of varying size and styles that may be used in neurosurgical applications as an arm rest during head and neck surgery when intra-operative CT or MR Imaging is required.

    Device Description

    The DORO® Radiolucent / MRI Compatible Cranial Stabilization and Halo Systems are for use in open and percutaneous craniotomies and spinal surgeries when rigid skeletal fixation is necessary (Skull Clamp with Skull Pins) or when secured noninvasive cranial stabilization (Horseshoe Headrest System) is required and when Intra-Operative CT or MR Imaging is used.

    Main components:

    • DORO® Radiolucent / MRI Compatible Skull Clamp Headrest System with Skull Pins
    • DORO® Radiolucent / MRI Compatible Horseshoe Headrest Systems
    • DORO® Radiolucent / MRI Compatible Halo System

    The DORO® Radiolucent / MRI Compatible Skull Clamp Headrest System uses a three-point fixation of the head during surgery in the prone, supine, lateral, and sitting positions via the radiolucent Skull Clamp with Skull Pins. The DORO® Radiolucent / MRI Compatible Horseshoe Headrest System is an alternative noninvasive gel-pad cranial stabilization system for prone and supine positioning. The Skull Clamp or Horseshoe Headrests can be connected to Swivel Adaptor which in turn can be connected to the appropriate Transitional Members (of varying lengths). These are all MR-Safe.

    The Radiolucent Halo System is a series of radiolucent rings (full, half and quarter rings) with fixation rods to attach to the radiolucent skull clamp described above. It provides a hand rest for the Surgeon and a mounting place for a variety of surgeon tools, such as brain Retractor and a holding tray. The Halo Rings and the Rod Fixation Assembly are all MR-Safe.

    The DORO® Radiolucent / MRI Compatible Cranial Stabilization and Halo Systems are sold non-sterile. The Swivel Adaptor, Skull Clamp and Horseshoe Headrests are intended to be cleaned by the user between uses. For rigid skeletal fixation, the Skull Clamp uses the disposable single-use ceramic (Yttried Zirconium) or Titanium Skull Pins, which are both x-ray and MRI-compatible.

    The components of the DORO® Headrest Systems are made of the following materials:

    • The Skull Clamp is made of NOVOTEX laminated fabric with phenolic resin (GRP) colored with BASANTOL black X82 liquid and POM (Delrin), PEEK and Polyurethan. MR-Safe.
    • The Swivel Adaptor and the Horseshoe Headrest in adult and pediatric versions, the Transitional Members and the Halo Systems are made of Novotex, PEEK and POM. MR-Safe.
    • DORO® Radiolucent Disposable Single-Use Skull Pins of Yttried Zirconium or Titanium are X-ray and MRI compatible. MR-Safe.

    The DORO® Radiolucent / MRI Compatible Cranial Stabilization and Halo Systems can be used with accessories from the predicate DORO® Headrest System (K001808) with Gel Pads for adults, Headrest supports with one or two Gel Pads, single Pin Holders, dual Pin Holders for adults, dual Pin Holders for children, a Multi-Purpose Skull Clamp with six Pin fixation or three Gel Pads.

    AI/ML Overview

    The provided text is a 510(k) summary for a medical device (DORO® Radiolucent / MRI Compatible Cranial Stabilization and Halo Systems). This document is a regulatory submission for premarket notification to the FDA, demonstrating that a new device is substantially equivalent to a legally marketed predicate device.

    It does not contain the acceptance criteria and study information typically found in a clinical performance study report for a diagnostic or AI-driven device. The document focuses on showing substantial equivalence based on design, construction, intended use, and performance characteristics compared to existing devices, particularly concerning its MRI compatibility.

    Therefore, many of the requested categories (such as reported device performance, sample size for test set, data provenance, number of experts for ground truth, adjudication method, MRMC study, standalone performance, type of ground truth, training set size, and ground truth for training set) are not applicable to this type of regulatory submission for this device.

    The "performance" aspect here refers more to the functional performance and safety of a mechanical device, rather than the accuracy of a diagnostic algorithm.

    Here's a breakdown of what can be extracted and what is not available from the provided text:


    Acceptance Criteria and Study for DORO® Radiolucent / MRI Compatible Cranial Stabilization and Halo Systems

    This 510(k) summary (K063494) for the DORO® Radiolucent / MRI Compatible Cranial Stabilization and Halo Systems focuses on establishing substantial equivalence to predicate devices, rather than presenting a clinical study with acceptance criteria for diagnostic performance. The "performance" discussed primarily relates to the device's mechanical integrity, radiolucency, and MRI compatibility.

    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance Criteria CategorySpecific Criteria (from document)Reported Device Performance (from document)
    Material CompositionUse of specific materials for radiolucency and MRI compatibility.Skull Clamp: NOVOTEX (laminated fabric with phenolic resin, colored with BASANTOL black X82 liquid), POM (Delrin), PEEK, and Polyurethane. MR-Safe. Swivel Adaptor, Horseshoe Headrest, Transitional Members, Halo Systems: Novotex, PEEK, and POM. MR-Safe. Skull Pins: Yttried Zirconium or Titanium. X-ray and MRI compatible. MR-Safe.
    Intended Use EquivalenceSimilar use cases as predicate devices for cranial stabilization and support during neurosurgery.Used for rigid skeletal fixation (Skull Clamp with Skull Pins) or non-invasive cranial stabilization (Horseshoe Headrest System) and as an armrest/tool mount (Halo System) in head and neck surgery, specifically when intra-operative CT or MR Imaging is used. This is an additional application compared to some predicates, enabled by the device's MRI compatibility.
    Biocompatibility (for contacting parts)No biocompatibility issues should be raised for patient-contacting components.Radiolucent components (non-sterile): Do not contact the patient. Materials: NOVOTEX colored with BASF Basantal, POM, and Polyurethane. DORO® Radiolucent Disposable Single-Use Skull Pins: Contact the patient, but "there is no biocompatibility issues raised." (This implies a review and satisfaction of biocompatibility, often through adherence to ISO 10993 or similar standards, though specific data is not provided in this summary).
    MRI CompatibilityDevice components must be MR-Safe.All specified components (Skull Clamp, Swivel Adaptor, Horseshoe Headrest, Transitional Members, Halo Systems, Skull Pins of Yttried Zirconium or Titanium) are explicitly stated as "MR-Safe."
    Cleaning/SterilizationInformation on cleaning/sterilization status.Sold non-sterile. Swivel Adaptor, Skull Clamp, and Horseshoe Headrests are "intended to be cleaned by the user between uses." Skull Pins are "disposable single-use."
    Compatibility with existing systemsAbility to integrate with predicate accessories.Can be used with accessories from the predicate DORO® Headrest System (K001808), including Gel Pads, Headrest supports, Pin Holders, and a Multi-Purpose Skull Clamp.
    General Equivalence"Similar in design, construction, intended use and performance characteristics to the predicate devices." (K032331, K001808, K051501xc for specific materials).The summary states: "This device is almost similar in design, construction, intended use and performance characteristics to the predicate devices."

    2. Sample size used for the test set and the data provenance

    • Not Applicable. This is a 510(k) for a mechanical device, not a diagnostic algorithm that requires a "test set" in the context of diagnostic accuracy. Data provenance would refer to where clinical data for performance assessment came from, which is not relevant here.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    • Not Applicable. No ground truth for a diagnostic test set is established. This device's performance is assessed through material properties, mechanical testing, and comparison of design features, not expert interpretation of outputs.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    • Not Applicable. No test set or adjudication process as defined for diagnostic performance is mentioned.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • Not Applicable. This is a mechanical surgical device, not an AI-powered diagnostic tool. MRMC studies are not relevant.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    • Not Applicable. This device does not involve an algorithm.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    • Not Applicable. The "ground truth" for this device's regulatory review would be adherence to material specifications, engineering standards, biocompatibility testing results (implied), and demonstration of functional equivalence (e.g., rigid fixation, MRI safety) to predicate devices rather than a medical "truth" like disease presence.

    8. The sample size for the training set

    • Not Applicable. No training set for an algorithm exists for a mechanical device.

    9. How the ground truth for the training set was established

    • Not Applicable. No training set for an algorithm exists for a mechanical device.

    In summary: The provided document is a 510(k) summary for a mechanical neurosurgical device. It addresses regulatory requirements by demonstrating substantial equivalence to previously cleared devices, primarily focusing on materials, construction, intended use, and functional properties like MRI compatibility. The questions regarding acceptance criteria, sample sizes, expert ground truth, and AI/algorithm performance are not applicable to the information contained within this type of submission for this device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K053282

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2005-12-13

    (18 days)

    Product Code
    Regulation Number
    878.4400
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K033245, K970541

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Ceramic tip electrodes are used during minimal invasive surgery, according to the professional surgeon and the instructions for use.

    Ceramic tip electrodes are instruments insulated for optional monopolar coagulation which enable a surgeon to grasp, manipulate, dissect, retrieve, biopsy, cut or coagulate internal tissue or organs while performing laparoscopic procedures.

    Device Description

    The Pajunk ceramic tip electrodes are multiple uses, non-sterile delivered and latex free medical devices. They are intended for transient delivery of energy required for coagulation of tissue.

    The Pajunk MIC-System contains but is not limited to HF-electrodes for comfortable and safe coagulation. Pajunk provides electrodes with and without suction and irrigation element and electrodes with suction and irrigation capacity with retractable/ extendable tips. Isolation at tip is made by ceramic.

    The Modular system for optional monopolar coagulation enables a surgeon to manipulate, dissect, retrieve, biopsy, cut or coagulate internal tissue or organs while performing laparoscopic procedures. The instruments are insulated for optional monopolar coagulation.

    The electrode-tips are retractable for comfortable suction and irrigation performance.

    The Pajunk ceramic tip electrodes are intended for transient delivery of energy required for coagulation of tissue. Ceramic tip electrodes are used during minimal invasive surgery, according to the professional surgeon and the instructions for use. The ceramic tip electrodes consist of a medical grade steel tube, ceramic tip and stainless steel electrode tip.

    AI/ML Overview

    The provided text is a 510(k) Premarket Notification Submission for a device called "Pajunk ceramic tip electrodes." This submission is primarily focused on demonstrating substantial equivalence to predicate devices, rather than presenting a study with specific acceptance criteria and performance data in the typical sense of a clinical or technical validation study.

    Therefore, an acceptance criteria table and details of a performance study as would be seen for novel devices with specific performance claims are not explicitly present in the provided document. The "study" here is the comparison to predicate devices to establish substantial equivalence.

    Here's an analysis based on the provided text, addressing your points where possible:

    1. Table of Acceptance Criteria and Reported Device Performance

    As noted, the submission focuses on substantial equivalence to predicate devices. The "acceptance criteria" are implied by the regulatory definition of substantial equivalence, meaning the new device has the same intended use and technological characteristics as the predicate, or if there are differences, they do not raise different questions of safety and effectiveness.

    Acceptance Criteria (Implied by Substantial Equivalence)Reported Device Performance (Summary from Submission)
    Intended Use: Same as predicate device.Same: "Pajunk ceramic tip electrodes are intended for transient delivery of energy required for coagulation of tissue. Ceramic tip electrodes are used during minimal invasive surgery, according to the professional surgeon and the instructions for use." This matches the general intended use of electrosurgical cutting and coagulation devices and accessories. (The predicate device (K033249) has an identical intended use).
    Technological Characteristics: Same as predicate device OR differences do not raise new questions of safety and effectiveness.Similar with one key difference (ceramic tip vs. polyamide): "Pajunk's monopolar ceramic tip electrodes have the same technological characteristics as the predicate device identified below. Pajunk's monopolar ceramic tip electrodes are substantially equivalent to Pajunk's monopolar electrodes marketed under 51000) number K033249. All materials, dimensions and intended use are identical. There is one exception, which is the electrical insulation at the electrode tip. The polyamide (Nylon) coating is substituted by a ceramic tip." "Equivalent in design, physical dimensions, ceramic, metal and plastics materials," to another predicate (Aesculap K970541). The only design difference mentioned for the Aesculap predicate is that "Aesculap's monopolar ceramic tips can be unlocked from the electrode shaft. Pajunk's monopolar ceramic tips are fixed to the electrode shaft and can not be removed, nor lost during a surgical procedure." This is presented as a safety improvement, not a new risk.
    Biocompatibility: Device materials are biocompatible.Biocompatibility testing performed: "Biocompatibility testing of Pajunk's monopolar ceramic tip electrodes is located in Section 7 of this submission." (Details of the results are not in the provided text, but the statement indicates it was addressed).
    Safety and Effectiveness: Demonstrated through comparison to predicate.Conclusion: "The comparison between the predicate device and the proposed device demonstrates that the proposed device is safe and effective, as well as substantially equivalent to the predicate device."

    2. Sample Size Used for the Test Set and Data Provenance

    • No specific "test set" and sample size are mentioned for performance assessment in the provided text.
    • Data Provenance: The "study" is a comparison to predicate devices, drawing upon their established safety and effectiveness. The predicate devices are Pajunk's monopolar electrodes (K033249) and Aesculap's modular monopolar ceramic tip electrodes (K970541), which would have undergone their own regulatory approval processes.

    3. Number of Experts Used to Establish Ground Truth and Qualifications

    • This type of expert review for "ground truth" establishment is not applicable to this 510(k) submission. The submission relies on demonstrating similarity to already cleared devices.

    4. Adjudication Method

    • Not applicable. There is no clinical or performance data requiring adjudication by experts described in this submission.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was Done

    • No. An MRMC study is typically performed to assess human reader performance, often with and without AI assistance. This submission does not involve AI or a complex interpretive task requiring such a study.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) was done

    • No. This device is a physical medical instrument (electrosurgical electrode), not an algorithm or software-driven device.

    7. The Type of Ground Truth Used

    • Not applicable in the typical sense. The "ground truth" for this 510(k) is essentially the established safety and effectiveness of the predicate devices as previously determined by the FDA's clearance decisions (K033249 and K970541). The entire premise of a 510(k) is that if a new device is "substantially equivalent" to a legally marketed predicate, then it is inherently safe and effective.

    8. The Sample Size for the Training Set

    • Not applicable. There is no "training set" as this is not a machine learning/AI device.

    9. How the Ground Truth for the Training Set was Established

    • Not applicable.
    Ask a Question

    Ask a specific question about this device