    Intended Use

    The Physician Industries' Radiofrequency Ablation Needle is a single use RF (radiofrequency) needle with injection capabilities. It can be used for either 1) (Fadiofrequency) in the lesioning, or 2) percutaneous nerve blocks with a local anesthetic solution. The nerve is localized by using electrical stimulation through the needle. The nerve may then be blocked either by the generating an RF lesion, or by the injecting of a local anesthetic. It is to be used only under the direction of a licensed clinician.

    Device Description

    The Physician Industries Inc. needle shares major similarities with the predicate device(s), inasmuch as the configuration, material, use, labeling and safety issues remain basically unchanged. It consists of a plastic hub, insert molded over a PTFE-coated stainless steel cannula.

    AI/ML Overview

    The provided text describes a 510(k) premarket notification for the Physician Industries' Radiofrequency Ablation Needle. This type of submission focuses on demonstrating "substantial equivalence" to a legally marketed predicate device, rather than proving safety and effectiveness through extensive, de novo clinical trials with detailed performance metrics and acceptance criteria. As such, the document does not contain the typical information for acceptance criteria and a study proving a device meets them in the way modern AI/software device submissions would.

    However, I can extract the relevant information from the document that speaks to how the device's safety and effectiveness were supported for its 510(k) clearance.

    Here's a breakdown based on the information available:

    1. Table of Acceptance Criteria and Reported Device Performance

    This document does not present a table of specific, quantifiable acceptance criteria or device performance metrics in the way a clinical trial for a novel device would. Instead, the "performance" is demonstrated by showing "substantial equivalence" to predicate devices. The implicit acceptance criteria are that the device performs as safely and effectively as the predicate devices.

    Acceptance Criteria Category (Implicit)Reported Device Performance
    Configuration and Material SimilarityThe Physician Industries Inc. needle "shares major similarities with the predicate device(s), inasmuch as the configuration, material, use, labeling and safety issues remain basically unchanged." It consists of "a plastic hub, insert molded over a PTFE-coated stainless steel cannula."
    Intended Use Equivalence"The Physician Industries' RF Ablation Needle shares the same basic characteristics and features and, therefore, are SE to the Radionic's Pole Needles, K021942, and K963577." Intended uses are identical: 1) radiofrequency (RF) lesioning, and / or 2) percutaneous nerve blocks with a local anesthetic solution.
    Safety Record"No record of unexpected patient problems or adverse reactions were found in our review of the FDA's MAUDE, Safety Alert..., and MDR databases" for the predicate devices.
    Manufacturing and Quality ControlThe device and its packaging will be tested by an independent lab for sterility, subjected to inspection/testing by IQC during/after manufacture QC, and monitored in the field by means of their CAPA system. Developed and documented under Physician Industries' mature Quality Management System, including design/change control, and verified/validated to applicable standards.
    Overall Substantial Equivalence"There are no substantive differences between the device defined in this 510(k) submission and the predicate devices. It is similar to the material and manufacturing / sterilization technologies that are currently used in other similar medical devices."

    2. Sample size used for the test set and the data provenance

    • Test Set: No specific test set of patients or medical cases is described in the document. The "test" for substantial equivalence relies on comparison with the predicate devices and their established safety and performance records.
    • Data Provenance: The document refers to "review of the FDA's MAUDE, Safety Alert..., and MDR databases" for adverse event data related to predicate devices. This would be retrospective data from the United States.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    Not applicable. The ground truth for this 510(k) submission is not established by expert consensus on a test set of data. Instead, the "ground truth" for the device's acceptable performance is implicitly the established safety and effectiveness of the existing predicate devices on the market, as cleared by the FDA.

    4. Adjudication method for the test set

    Not applicable, as no human-adjudicated test set is described.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This is a medical device (a physical RF ablation needle), not an AI/software device. Therefore, no MRMC study, human reader improvement, or AI assistance is relevant.

    6. If a standalone (i.e. algorithm only without human-in-the loop performance) was done

    Not applicable, as this is a physical medical device.

    7. The type of ground truth used

    The "ground truth" in the context of this 510(k) submission is the documented safety and effectiveness of the predicate devices (Radionics' Pole Needle, K021942 and K963577) as legally marketed and reviewed by the FDA. This is based on regulatory history and prior clearances rather than an independent gold standard for a new device.

    8. The sample size for the training set

    Not applicable. This is a physical medical device. There is no "training set" in the machine learning sense. The design and manufacturing processes are informed by general engineering principles and quality systems compliant with 21 CFR Part 820.

    9. How the ground truth for the training set was established

    Not applicable. There is no training set as understood in AI/ML contexts. The device design and manufacturing are based on established engineering practices, material science, and regulatory requirements for medical devices, aiming to replicate the established performance and safety profile of equivalent predicate devices.

    Ask a Question

    Ask a specific question about this device

    K Number
    K021329

    Validate with FDA (Live)

    Device Name
    RITA SYSTEM
    Date Cleared
    2002-10-09

    (166 days)

    Product Code
    Regulation Number
    878.4400
    Predicate For
    Why did this record match?
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The RITA® System (RF generator and electrosurgical devices) supplies energy for use in electrosurgery and is indicated for use in percutaneous, laparoscopic, or intraoperative coagulation and ablation of soft tissue, including:

    • the partial or complete ablation of non-resectable liver lesions and
    • the palliation of pain associated with metastatic lesions involving bone in patients who have failed or are not candidates for standard pain therapy.
    Device Description

    The RITA System (RF Generator and electrosurgical devices) is designed to create coagulative necrotic lesions in soft tissue, and allow localized delivery of fluid to the lesion. The RF Generator is specifically designed for use with RITA Electrosurgical Devices (Accessories). The RF Generator provides multiple temperature sensors, impedance, and power monitoring to assist the user in delivering the desired energy to the target tissue. The electrosurgical devices consist of monopolar electrosurgical devices that include disposable electrosurgical probes with deployable needle arrays that deliver RF power with temperature and impedance monitoring to ablate predictable volumes of tissue.

    AI/ML Overview

    The provided text describes the RITA® System, an electrosurgical device, and its intended use and performance data. However, it does not contain the detailed information necessary to fully answer all aspects of your request regarding acceptance criteria and a specific study proving device performance against those criteria.

    Here's what can be extracted and what information is missing:

    1. Table of Acceptance Criteria and Reported Device Performance

    The document does not explicitly state formal acceptance criteria (e.g., target specificity, sensitivity, or similar metrics for a diagnostic device). Instead, it describes a clinical study and its observed outcomes as a measure of effectiveness.

    Acceptance CriteriaReported Device Performance
    (Not explicitly defined in terms of specific performance metrics for this device, which is a therapeutic device for ablation and pain palliation)Effectiveness for Pain Palliation (Worst Pain): 75% of patients experienced at least a two-point reduction in "worst pain" from baseline to week four.
    Effectiveness for Pain Palliation (Average Pain): 80% of patients experienced at least a two-point reduction in "average pain" from baseline to week four.
    Safety/Morbidity: Low attendant morbidity (no reports of death related to use of the devices).
    Adverse Events: Three adverse events potentially related to RF ablation.
    (Bench study findings on ablation characteristics/parameters)Bench studies determined the effect of the bone environment on ablation characteristics and parameters. (Specific quantitative results not provided).

    2. Sample Size Used for the Test Set and Data Provenance

    • Sample Size: The document does not explicitly state the total number of patients in the clinical study. It refers to percentages of "patients" (75% and 80%) but not the base number.
    • Data Provenance: The study was conducted on "patients with lesions that had metastasized to one or more locations in the skeleton." It is a prospective clinical study assessing safety and effectiveness. The country of origin for the data is not specified.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Their Qualifications

    This information is not provided in the document. For a therapeutic device like this, "ground truth" would typically relate to clinical outcomes rather than expert-derived labels on images.

    4. Adjudication Method for the Test Set

    This information is not provided in the document. Given the nature of pain palliation as an endpoint, "adjudication" in the sense of expert consensus on image interpretation is less relevant. The effectiveness was measured using a "validated instrument for evaluating cancer pain," suggesting a standardized assessment.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done, and the Effect Size

    This information is not provided. The study described is a clinical study evaluating the device's effectiveness in alleviating pain, not a comparative effectiveness study involving human readers with/without AI assistance. The device itself is an RF ablation system, not an AI diagnostic tool that assists human readers.

    6. If a Standalone (Algorithm Only Without Human-in-the-Loop Performance) Study Was Done

    This question is not applicable to the RITA® System as described. It is a physical medical device (RF generator and electrosurgical devices) that requires direct human operation, not a standalone algorithm. The "performance" refers to the device's clinical efficacy and safety when used by a clinician.

    7. The Type of Ground Truth Used

    The "ground truth" for the effectiveness of the RITA® System's pain palliation indication was based on:

    • Outcomes Data: Specifically, patient-reported pain levels assessed using an "instrument validated for evaluating cancer pain."
    • Safety Data: Observed adverse events and mortality related to the device's use.

    8. The Sample Size for the Training Set

    This information is not applicable/not provided. The RITA® System is a physical electrosurgical device, not a machine learning algorithm that requires a "training set" in the computational sense. The "bench studies" mentioned would involve laboratory testing, not a data training set.

    9. How the Ground Truth for the Training Set Was Established

    This question is not applicable for the same reasons as #8. There is no "training set ground truth" in the context of this device.

    In summary, the provided text describes a clinical study demonstrating the RITA® System's effectiveness in pain palliation and its safety profile. However, it does not detail specific, quantitative acceptance criteria in a tabular format, nor does it address aspects related to AI/algorithm performance (like training sets, expert adjudication, or MRMC studies) as the device is a therapeutic electrosurgical system.