510(k) Data Aggregation

    K Number
    K963180

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    1996-10-10

    (57 days)

    Product Code
    Regulation Number
    878.4400
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K955035

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The VIDAMED RF Generator Data Recorder is indicated for use in recording patient treatment data when used in conjunction with VIDAMED RF Generators such as the VIDAMED Model 7205 RF Generator. The data recorder software does not control or effect the output of power from the RF Generator, nor is it intended to be used in the treatment or diagnosis of any disease.

    Device Description

    The VIDAMED RF Generator Data Recorder is designed for use with VIDAMED RF Generators such as the VIDAMED Model 7205 RF Generator. When used with VIDAMED RF Generators, the VIDAMED RF Generator Data Recorder Software is capable of recording the lesion temperature, proximal shield (urethral) temperature, needle impedance, power delivered, and total energy delivered.

    AI/ML Overview

    The provided text describes a medical device, the "VIDAMED RF Generator Data Recorder," and its intended use. However, it does not contain any information about acceptance criteria, device performance studies, sample sizes, ground truth, or expert involvement for the purpose of validating performance.

    This document is a 510(k) summary, which focuses on demonstrating substantial equivalence to a predicate device rather than providing a detailed performance study report. The key points from the provided text are:

    • Indication: Records patient treatment data when used with VIDAMED RF Generators.
    • Function: Records lesion temperature, proximal shield (urethral) temperature, needle impedance, power delivered, and total energy delivered.
    • Limitation: The software does not control or affect the output of power from the RF Generator and is not intended for treatment or diagnosis.
    • Substantial Equivalence: It is an accessory to the VIDAMED Model 7205 RF Generator (K955035).

    Therefore, I cannot provide the requested information based on the input text. The text explicitly states: "No performance standard(s) or special controls applicable to this device have been promulgated under Section 514 of the Act," which further implies that a specific performance study with acceptance criteria, as one might find for a diagnostic or therapeutic device, is not detailed here.

    To answer your questions, I would need a different type of document, such as a clinical study report, a validation study report, or a detailed performance specification document for the device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K960918

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    1996-10-08

    (216 days)

    Product Code
    Regulation Number
    878.4400
    Age Range
    All
    Reference & Predicate Devices
    Why did this record match?
    Reference Devices :

    K951245, K955035

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The TUNA System is indicated for the treatment of symptoms due to urinary outflow obstruction secondary to benign prostatic hyperplasia (BPH) in men over the age of 50 with prostate sizes between 20 and 50 cc.

    Device Description

    The TUNA® System consists of the TUNA® 3 Catheter, the VIDAMED Model 7205 RF Generator, the VIDAMED Return Electrode, the VIDAMED Rectal Monitoring Tape, and the TUNA® Optics.

    The electrosurgical generator is capable of delivering up to 30W (15W / channel) of power and is designed for use with VIDAMED accessory electrodes including the TUNA® 3 Catheter. When used with VIDAMED accessory electrodes, the electrosurgical generator is capable of reading temperature from thermocouple sensors within the electrode and controlling power output to the tissue.

    AI/ML Overview

    The provided text is a 510(k) summary for the VIDAMED TUNA® (Trans Urethral Needle Ablation) System, which is a medical device for treating benign prostatic hyperplasia (BPH). This document describes the device, its indication, and its substantial equivalence to other devices.

    However, it does not contain any information regarding acceptance criteria, study design, sample sizes, ground truth establishment, expert qualifications, adjudication methods, or MRMC studies related to device performance.

    The summary states: "Confirmatory clinical data is also provided to support the safety and effectiveness of the device for use in the treatment of symptoms due to urinary outflow obstruction secondary to BPH." However, it does not detail the specifics of this clinical data or how it relates to acceptance criteria.

    Therefore, I cannot fulfill your request for the detailed information as the input text does not contain it.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1