510(k) Data Aggregation

    K Number
    K981376

    Validate with FDA (Live)

    Date Cleared
    1999-01-04

    (263 days)

    Product Code
    Regulation Number
    870.1025
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K950821, K960934, K922974, K945134, K961247

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Condition: Viridia 24 CT is generally indicated when the clinician decides there is a need to measure and display multiple physiological parameters and waves, to generate alarms and recordings of adult, pediatric, or neonatal patients.

    Part of Body or Type of Tissue with Which the Device Interacts: Viridia 24 CT does not contact the body or tissue of the patient. Signals are obtained from accessory electrode, transducer, and sensor devices.

    Frequency of Use: Viridia 24 CT is indicated for use when prescribed by a clinician.

    Physiological Purpose: Viridia 24 CT is indicated when the purpose is to gain information for treatment, to assess adequacy of treatment, or to rule out causes of symptoms. Viridia 24 CT is well suited for patient monitoring.

    Patient Population: Adult, pediatric, and neonatal non-ambulatory patients.

    Prescription Versus Over-the-Counter: Viridia 24 CT is a prescription device.

    Device Description

    Viridia 24 CT is a patient monitor. This submission notifies the FDA that the power source was modified. No other significant changes were made to the device.

    AI/ML Overview

    The provided text describes a 510(k) submission for the Hewlett-Packard M1205A Viridia 24 CT, a patient monitor. This document focuses on the regulatory approval process for a medical device and its intended use, rather than a study evaluating its performance against specific acceptance criteria in the way an AI algorithm or a diagnostic tool would be evaluated.

    Therefore, many of the requested elements for an acceptance criteria study, such as sample size, data provenance, ground truth establishment, expert qualifications, and comparative effectiveness studies, are not present in this type of regulatory submission. The document states that the device has undergone "Verification and Validation" and "extensive testing" to show "substantial equivalence" to legally marketed predicate devices, but it does not detail the specific performance metrics or the studies conducted to meet them.

    Here's an analysis based on the information provided:

    1. A table of acceptance criteria and the reported device performance

    The document does not provide a table of specific quantitative acceptance criteria (e.g., sensitivity, specificity, accuracy, or a specific range of measurement error) or reported device performance for these criteria. Instead, the "acceptance criteria" are broad statements related to safety, effectiveness, and substantial equivalence to predicate devices.

    Acceptance Criteria (Inferred from Document)Reported Device Performance (Inferred from Document)
    Safe and Effective when used as labeled"Documented test results obtained from extensive testing coupled with detailed user documentation... produces a very high confidence level that the device is safe and effective when used as intended."
    Substantial Equivalence to predicate devices"Viridia 24 CT has been verified and validated to provide the test results needed to show substantial equivalence to legally marketed devices."
    Measures and displays multiple physiological parameters and wavesIntended purpose of the device.
    Generates alarms and recordingsIntended purpose of the device.
    Exchanges information with compatible devicesIntended purpose of the device.
    Suitable for intra-facility transportStated intended use.

    2. Sample size used for the test set and the data provenance

    The document does not specify a "test set" in the context of an AI/diagnostic algorithm evaluation. It mentions "extensive testing" but provides no details on sample sizes, data provenance (country of origin, retrospective/prospective nature), or patient characteristics for these tests. The focus is on the device's functional integrity and its ability to perform its stated purpose, not on its diagnostic accuracy or predictive power.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    Not applicable. This device is a physiological monitor, not a diagnostic tool that relies on expert interpretation for "ground truth" establishment in the way an AI algorithm would.

    4. Adjudication method for the test set

    Not applicable. There is no mention of a test set with human assessments requiring adjudication.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This is a standalone patient monitor, not an AI-assisted diagnostic tool.

    6. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done

    This device is not an algorithm, but a hardware patient monitor. Its performance is inherent in its measurement capabilities. The document states it is "not a therapeutic device" and "not intended for home use," aligning with a "standalone" monitoring function used by clinicians. The device's "performance" would be related to the accuracy and reliability of its physiological parameter measurements, which are not detailed here.

    7. The type of ground truth used

    For a physiological monitor, the "ground truth" would implicitly be the actual physiological parameters being measured by the device (e.g., heart rate, blood pressure, etc.), typically established through direct physical measurement or comparison with established gold-standard instruments. The document does not specify how this "ground truth" was established for verification/validation.

    8. The sample size for the training set

    Not applicable. This is a hardware patient monitor, not an AI algorithm that requires a training set.

    9. How the ground truth for the training set was established

    Not applicable. As above, this device does not utilize a training set in the AI sense.

    Ask a Question

    Ask a specific question about this device

    K Number
    K974567

    Validate with FDA (Live)

    Date Cleared
    1998-01-20

    (46 days)

    Product Code
    Regulation Number
    870.2300
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K961165, K922974, K945134, K923343

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Viridia Wave Viewer may be used to provide limited ECG and SpO2 information to the clinician. Patient assessment includes uses similar to:

    • Determination of a patient's tolerance to exercise during ambulation (e.g. while walking down a hallway).
    • Patient assessment while waiting for monitoring equipment to arrive (e.g. a patient collapses in the hallway).
    • Additional input to a routine physical assessment of a patient (e.g. for use on rounds).

    Patient assessment does not include uses such as:

    • Continuous monitoring of a patient (not intended for use as a bedside monitor).
    • Determining detailed ECG diagnosis such as ST segment values, R-R variability or any other diagnostic ECG values.

    The patient population is adult and pediatric patients.

    There are no alarms. The device turns off after 10 minutes to prevent long term "monitoring" use. Viridia Wave Viewer is not intended to be a patient monitor.

    In the USA, Federal law restricts Viridia Wave Viewer to sale by or on the order of a physician.

    It is intended to be used in a professional health care facility. It is not intended for home use.

    The device is intended to be used as an assessment tool that enables licensed clinicians in a clinical environment to determine the quality of ECG and SpO2 signals at the location of telemetry monitored patients. In addition, limited assessment of patients ECG and SpO2 vital signs can be determined. Viridia Wave Viewer is not intended for monitoring and has no alarm functions. The device is not intended for home use and is not suitable for patient monitoring.

    Device Description

    Viridia Wave Viewer is a software application that executes on a palmtop computer. Viridia Wave Viewer software enables the palmtop computer to communicate with the M2601A transmitter using an infrared link for the purpose of displaying ECG waveform, or an SpO2 pleth waveform, and numerics for SpO2 and Pulse. Viridia Wave Viewer also allows the user to estimate the heart rate, HR, by using electronic calipers to measure the distance between two R-peaks. Viridia Wave Viewer does not operate on the information received except to format it for display on the palmtop screen. It performs no calculations except for estimating HR. It has no detection capability. It can not, therefore, annunciate any alarms.

    AI/ML Overview

    This document, K974567, details a 510(k) submission for the Hewlett-Packard M2605A Viridia Wave Viewer. However, it does not contain specific acceptance criteria, performance metrics, or a detailed study description that would allow for a complete response to your request. The document acts as a summary for FDA clearance, not a full scientific study report.

    The "Verification and Validation" section (6.0) states: "Viridia Wave Viewer has been verified and validated to provide the test results needed to show substantial equivalence to legally marketed devices." This implies that testing was performed, but the details are not provided within this summary.

    Therefore, I can only provide information based on what is available in the provided text. Many sections of your request cannot be answered due to the lack of detailed study information.

    Here's an analysis based on the available information:

    1. Table of Acceptance Criteria and Reported Device Performance

    This information is not present in the provided document. The document states that verification and validation were performed to show substantial equivalence, but it does not list specific numeric acceptance criteria (e.g., accuracy, precision) or the results of those tests.

    2. Sample Size Used for the Test Set and Data Provenance

    This information is not present in the provided document. The document refers to "extensive testing" but does not specify sample sizes or data origin (country, retrospective/prospective).

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Their Qualifications

    This information is not present in the provided document.

    4. Adjudication Method for the Test Set

    This information is not present in the provided document.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    A multi-reader multi-case (MRMC) comparative effectiveness study was not conducted or reported in this document. The device, Viridia Wave Viewer, is described as a software application for a palmtop computer that displays ECG and SpO2 waveforms and numerics. It specifically states: "Viridia Wave Viewer does not operate on the information received except to format it for display on the palmtop screen. It performs no calculations except for estimating HR. It has no detection capability. It can not, therefore, annunciate any alarms." This functionality suggests a display-only device with a simple HR estimation, not one that would typically be involved in a comparative effectiveness study of AI assistance for human readers in decision-making.

    6. Standalone (Algorithm Only Without Human-in-the-Loop Performance) Study

    This document does not report a standalone performance study. While testing certainly occurred to ensure proper display and basic HR estimation, the nature of this device (a display and rudimentary HR estimation tool) means that "standalone performance" in the sense of a complex algorithm's diagnostic accuracy is not applicable or elaborated upon here. Its function is to present data from existing monitoring equipment.

    7. Type of Ground Truth Used

    This information is not explicitly stated in the provided document. Given the device's function to display ECG and SpO2 waveforms and numerics from existing monitoring equipment, the "ground truth" for its verification and validation would likely involve:

    • Comparison to the source monitoring equipment: Ensuring the displayed waveforms and numerics accurately reflect what the M2601A transmitter is sending.
    • Manual calculation verification: For the estimated heart rate, comparison to a manually calculated heart rate derived from the displayed ECG.

    8. Sample Size for the Training Set

    This information is not present in the provided document. As the device mainly displays information and performs a simple HR estimation, it is unlikely to have a "training set" in the sense of a machine learning algorithm.

    9. How the Ground Truth for the Training Set Was Established

    This information is not present in the provided document. As mentioned above, a "training set" in the context of device learning is likely not applicable to this particular device's functionality.