510(k) Data Aggregation

    K Number
    K103520

    Validate with FDA (Live)

    Date Cleared
    2011-06-24

    (206 days)

    Product Code
    Regulation Number
    870.3800
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K020864,K923367,K912554

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Carpentier-Edwards Physio Tricuspid annuloplasty ring, model 6200, is intended for use in patients with tricuspid valvular insufficiency. It is intended to correct annular dilatation, increase leaflet coaptation, reinforce annular suture lines, and prevent further dilatation of the annulus.

    Device Description

    The Carpentier-Edwards Physio Tricuspid annuloplasty ring, model 6200, is constructed of a titanium core with a silicone sewing ring margin covered with a polyester cloth.

    AI/ML Overview

    Here's an analysis of the provided information regarding the acceptance criteria and study for the Carpentier-Edwards® Physio Tricuspid™ annuloplasty ring, model 6200:

    Summary of Acceptance Criteria and Device Performance for K103520

    This 510(k) submission describes a medical device, an annuloplasty ring, and its substantial equivalence to predicate devices, rather than an AI/ML powered device. Therefore, the questions related to AI/ML specific aspects (training set, test set, ground truth experts, MRMC studies, standalone performance) are not applicable in this context. The acceptance criteria here refer to the successful completion of design verification and validation testing for a physical medical device.

    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance Criteria CategorySpecific Tests ConductedReported Device Performance
    Functional/Safety TestingComputational stress analysis, Finite element analysis, Tensile strength, Suture retention, Flexibility, Ring / Ring holder removal force, Corrosion resistance, Magnetic resonance compatibility (RF heating, image artifact, displacement force, induced torque), Biocompatibility (percent inhibition of cell growth, medium eluate method - cytotoxicity, blood compatibility, complement activation, gene mutation assay, chromosomal aberration effect assay, agar overlay - cytotoxicity, DNA damage / effects assay, Mouse systemic injection - systemic toxicity, rabbit pyrogen - systemic toxicity, rabbit intracutaneous reactivity, guinea pig maximization, rabbit intramuscular implantation sub-chronic and chronic evaluations), Relative resistance evaluation and comparison for sterilization, Bioburden, Limulus amebocyte lysate pyrogen testing, Packaging qualification (visual inspection, sterile barrier integrity, dye leak, burst), Shelf-life assessments of packaging and product components, Design validation by surgeons in simulated use environment."The Carpentier-Edwards Physio Tricuspid annuloplasty ring, model 6200, has successfully completed design verification and validation testing." (A general statement of success across all listed tests, without specific numerical results in this summary document.) The conclusion is that the device is "substantially equivalent to its predicate devices."

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    • Not Applicable: This is a physical medical device, not an AI/ML system. There is no "test set" in the context of data for an algorithm. The testing involves physical prototypes or materials of the device. The provenance of the "data" would refer to where the biomechanical, material, and biocompatibility testing was performed. This information is not detailed in the summary, but such testing is typically done in controlled laboratory environments.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    • Not Applicable: This is a physical medical device. There is no "ground truth for a test set" in the sense of expert annotation for an algorithm. However, the summary mentions "Design validation by surgeons in simulated use environment." While the number of surgeons and their specific qualifications are not provided in this summary, these would be the "experts" involved in validating the device's usability and surgical handling.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    • Not Applicable: As this is not an AI/ML system evaluating data, there is no "adjudication method" for a test set of data. The design validation by surgeons would likely involve observation, feedback, and potentially consensus or individual assessments of the device's performance in a simulated environment.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • Not Applicable: This is a physical medical device, not an AI/ML system, so MRMC studies involving human readers and AI assistance are irrelevant here.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    • Not Applicable: This is a physical medical device, not an algorithm. Standalone performance refers to an AI system operating independently; this concept does not apply to a heart valve ring.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    • Not Applicable (in the AI/ML sense): For a physical medical device, "ground truth" relates to established engineering standards, material science properties, biological compatibility guidelines, and successful clinical outcomes (which are implicitly aimed for). The successful completion of the listed functional/safety tests against established benchmarks and standards (e.g., ISO 10993 for biocompatibility, ASTM standards for MR compatibility) serves as the "ground truth" that the device meets its design requirements. Surgical design validation by experts also contributes to establishing usability "ground truth."

    8. The sample size for the training set

    • Not Applicable: This is a physical medical device, not an AI/ML system. There is no concept of a "training set" for an annuloplasty ring. Device development involves iterative design, prototyping, and testing.

    9. How the ground truth for the training set was established

    • Not Applicable: There is no training set or ground truth in the AI/ML sense. For a physical device, the "ground truth" for its development involves engineering principles, material specifications, regulatory standards, and clinical needs that guide its design and subsequent testing.
    Ask a Question

    Ask a specific question about this device

    K Number
    K083623

    Validate with FDA (Live)

    Date Cleared
    2009-04-15

    (128 days)

    Product Code
    Regulation Number
    870.3800
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K912554, K926138, K032250

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Carpentier-McCarthy-Adams IMR ETlogix Mitral Annuloplasty Ring is indicated for the correction of mitral valvular insufficiency where the lesions are not so severe as to require total valve replacement.

    The decision to undertake valvuloplasty can be made only after visual analysis of the lesion present. The most favorable conditions for valvuloplasty using an annuloplasty ring are a combination of a distended natural valve ring associated with supple valve cusps and normal chordae tendineae.

    The remodeling valvuloplasty technique with a prosthetic ring may be used in all acquired or congenital mitral insufficiencies with dilatation and deformation of the fibrous mitral annulus.

    For Type I mitral insufficiencies with no subvalvular lesions and normal valvular movements, this ring technique used alone is sufficient. However, the ring technique must be associated with mitral valvuloplasty repair in Type II insufficiencies with prolapsed valve due to elongation or rupture of the chordae tendineae and in Type III insufficiencies with limitation of valvular movements due to fusion of the commissures of chordae tendineae, or chordal hypertrophy.

    Device Description

    The Carpentier-McCarthy-Adams IMR ETlogix annuloplasty ring, model 4100 (IMR ETlogix) is constructed of titanium alloy and has a sewing ring margin that consists of a layer of silicone rubber covered with a woven polyester cloth.

    AI/ML Overview

    This 510(k) premarket notification for the Carpentier-McCarthy-Adams IMR ETlogix Mitral Annuloplasty Ring, model 4100, does not contain information about specific acceptance criteria, a formal study demonstrating the device meets those criteria, or details regarding diagnostic performance.

    The document focuses on demonstrating substantial equivalence to predicate devices rather than proving specific performance metrics against pre-defined acceptance criteria. The key sections stating this are:

    • Comparative Analysis: "It has been demonstrated that the Carpentier-McCarthy-Adams IMR ETlogix mitral annuloplasty ring is comparable to the predicate devices in design, intended use, materials, and principal of operation."
    • Functional/Safety Testing: "The Carpentier-McCarthy-Adams IMR ETlogix mitral annuloplasty ring has successfully completed design verification testing."
    • Conclusion: "The Carpentier-McCarthy-Adams IMR ETlogix mitral annuloplasty ring is substantially equivalent to the predicate devices."

    Therefore, I cannot populate the table and answer your specific questions about acceptance criteria, study details, and performance metrics as they are not present in the provided text. The document does not describe a study involving diagnostic performance, human readers, or ground truth establishment.

    A 510(k) submission typically aims to show that a new device is "substantially equivalent" to a legally marketed predicate device, rather than requiring extensive clinical trials to prove novel performance against specific quantitative criteria, especially for Class II devices like this annuloplasty ring. The "design verification testing" mentioned would primarily ensure the device meets its own internal design specifications and safety requirements, rather than a diagnostic performance study.