Search Filters

Search Results

Found 2 results

510(k) Data Aggregation

    K Number
    K171389

    Validate with FDA (Live)

    Date Cleared
    2017-08-08

    (89 days)

    Product Code
    Regulation Number
    888.3560
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    Why did this record match?
    Reference Devices :

    Series I Total Knee System, K892800/K895639/K911572/K930831 MG II Total Knee System – Flat, AP Lipped, K862837

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The EVOLUTION® Revision CCK System is indicated for use in knee arthroplasty in skeletally mature patients with the following conditions:

    1. Non-inflammatory degenerative joint disease: including osteoarthritis, traumatic arthritis, or avascular necrosis
    2. Inflammatory degenerative joint disease, including rheumatoid arthritis;
    3. Correction of functional deformity
    4. Revision procedures where other treatments or devices have failed; and treatment of fractures that are unmanageable using other techniques.
      The EVOLUTION® Medial-Pivot Total Knee System Nonporous implants are for cemented use only.
    Device Description

    EVOLUTION® Revision CCK (Constrained Condylar Knee) is being introduced to supplement MicroPort Orthopedics' knee product lines to provide options in the case of revision or complex primary total knee replacements. The design features are summarized below:

    • Components manufactured from cobalt chrome alloy, titanium alloy, and UHMWPE conforming to ASTM F75, F136, and F648, respectively
    • . Available in 8 standard sizes, left and right
    • Available in 2 plus sizes, left and right
    • . System includes femoral component, augments, stem offset adapters, tibial insert and stem cap
    AI/ML Overview

    The provided text describes the MicroPort Orthopedics EVOLUTION® Revision CCK System, a knee joint prosthesis. However, it does not contain a study that establishes acceptance criteria and then proves the device meets those criteria in the typical format of a diagnostic or AI/software device.

    Instead, this 510(k) summary focuses on demonstrating "substantial equivalence" to predicate devices based on design features, materials, and non-clinical performance testing. The information provided is primarily related to mechanical and material performance rather than diagnostic accuracy or human performance with or without AI.

    Therefore, I cannot fulfill all parts of your request as posed because the document is not an "acceptance criteria study" in the sense you are asking for. It is a regulatory submission demonstrating substantial equivalence.

    Based on the provided text, I can extract information relevant to non-clinical performance testing:

    1. Table of Acceptance Criteria and Reported Device Performance

    The document does not explicitly state quantitative "acceptance criteria" for each test in a pass/fail format alongside numerical performance values. Instead, it describes comparative performance against a predicate device. The general "acceptance criteria" can be inferred as performing "as well as" or "greater than" the predicate device for various mechanical properties to demonstrate substantial equivalence.

    Acceptance Criterion (Inferred)Reported Device Performance
    Bacterial Endotoxin Limit (< 20 EU/device)Less than the USP endotoxin limit of 20 EU/device.
    Patellofemoral Contact Area (Perform as well as predicate)Performed as well as the predicate K990030 implants.
    Tibiofemoral Contact Area (Perform as well as predicate)Possessed greater maximum contact area than the predicate K990030 implants.
    Tibial Post Shear Fatigue (Perform as well as predicate)Demonstrated greater fatigue resistance than the predicate K990030.
    Taper Disassembly (Withstand typical in vivo forces)Withstand typical in vivo disassociation forces as reported in peer-reviewed literature.
    Taper Fatigue (Achieve values greater than predicate)Achieved taper disassembly values greater than those of the predicate K162026 for Femoral constructs.

    2. Sample size used for the test set and the data provenance: Not applicable. This document describes non-clinical (laboratory) testing, not a test set derived from patient data. The "samples" would be the manufactured device components themselves, tested in a lab setting. The provenance is internal laboratory testing by MicroPort Orthopedics Inc.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts: Not applicable. This is not a study requiring expert-established ground truth.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set: Not applicable.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance: Not applicable. This device is a physical knee prosthesis, not an AI/software device for interpretation.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done: Not applicable.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc): Not applicable. The "truth" for these non-clinical tests would be the measurement results against established engineering and material standards or comparisons to predicate devices' performance.

    8. The sample size for the training set: Not applicable. This device is not an AI algorithm.

    9. How the ground truth for the training set was established: Not applicable.

    Ask a Question

    Ask a specific question about this device

    K Number
    K020830

    Validate with FDA (Live)

    Date Cleared
    2002-06-06

    (84 days)

    Product Code
    Regulation Number
    888.3560
    Age Range
    All
    Predicate For
    N/A
    Why did this record match?
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Scorpio® Inset Patellar Component is intended to articulate with any commercially available Scorpio® Total Knee Femoral Component, any commercially available Osteonics® Series 7000 Total Knee Femoral component, and any commercially available Osteonics® Omnifit® Total Knee Femoral Component. The subject patellar components are single use devices, intended for cemented applications on the surgically prepared posterior patella as part of primary or revision cemented total knee arthroplasty. This component replaces the patellar articulating surface of the knee joint to simulate the normal function of the knee.

    Indications:

    • . Painful, disabling joint disease of the knee resulting from: degenerative arthritis, rheumatoid arthritis or post-traumatic arthritis.
    • . Post-traumatic loss of knee joint configuration and function.
    • . Moderate varus, valgus, or flexion deformity in which the ligamentous structures can be returned to adequate function and stability.
    • . Revision of previous unsuccessful knee replacement or other procedure.
    Device Description

    The Scorpio® Inset Patellar Component is fabricated from ultra-high molecular weight polyethylene (UHMWPE). The component is available in one thickness (10mm) and four diameters (26mm, 28mm, 30mm, and 32mm). The overall geometry essentially consists of a circular patellar button configuration with a central peg on the anterior surface of the component. The anterior surface also features a pocket and undercuts for cement interdigitation. The subject Scorpio® Inset Patellar Component is mounted to the surface of the surgically prepared patella within a recessed hole when cementing the component into place.

    The articular (posterior) surface of this component is identical to the articular surface of the Osteonics® Recessed Patellar Component, found substantially equivalent in premarket notification K863668, and cleared for use with Scorpio femoral components in K962152. The anterior (bone fixation) surface is similar to that of the Duracon® Recessed Patellar Component (#K951655).

    AI/ML Overview

    This is a medical device submission for the Scorpio® Inset Patellar Component. The document describes the device, its indications for use, contraindications, and explains that substantial equivalence was supported by testing. However, this document does not contain the specific details required to answer your questions about acceptance criteria and a study proving those criteria were met.

    Here's why and what can be extracted:

    Why the requested information is not fully present:

    • Acceptance Criteria and Reported Device Performance: This document states "Testing was presented to support the claim of substantial equivalence," but it does not detail what those tests were, what the acceptance criteria for those tests were, or what the specific performance results were. For example, it doesn't mention fatigue testing limits, wear rates, a certain percentage of successful implantations, or a 95% confidence interval for a specific outcome.
    • Study Details (Sample Size, Data Provenance, Experts, Adjudication, MRMC, Standalone, Ground Truth, Training Set): These are all highly detailed aspects of a clinical study or performance study. This 510(k) summary is a high-level overview for regulatory purposes, aiming to demonstrate substantial equivalence to existing predicate devices. It does not include the detailed methodology of any specific study (clinical or non-clinical) in the way a clinical trial report or a comprehensive engineering test report would. For a medical device like a knee implant, the "study" proving it meets acceptance criteria would likely involve a combination of:
      • Bench testing: Mechanical strength, wear, fatigue, material compatibility – these would have acceptance criteria related to engineering standards (e.g., ISO, ASTM).
      • Biocompatibility testing: As per ISO 10993.
      • Possibly a clinical assessment: Though often, for devices seeking substantial equivalence, extensive new clinical trials are not required if predicate devices have established safety and effectiveness. If a clinical study was done, the details you asked for would be in that study protocol and report, not in this 510(k) summary.

    What can be extracted from the provided text:

    • Device Name: Scorpio® Inset Patellar Component
    • Purpose of the "Testing": To support the claim of substantial equivalence to predicate devices (Osteonics® Recessed Patellar Component and Duracon® Recessed Patellar Component).
    • Device Type: Knee joint patellofemorotibial polymer/metal/polymer semi-constrained cemented prosthesis.
    • Material: Ultra-high molecular weight polyethylene (UHMWPE).

    In summary, to answer your specific questions, you would need to access the actual "Testing" documents that were presented to the FDA, which are not included in this 510(k) summary. This document confirms that testing was done to support substantial equivalence, but not what that testing entailed or its specific results and criteria.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1