Search Filters

Search Results

Found 1 results

510(k) Data Aggregation

    K Number
    K961378

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    1996-10-08

    (181 days)

    Product Code
    Regulation Number
    888.3360
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K901687, K873797, K850055

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Delta Hip Prosthesis is designed for press-fit fixation into the human femur as a component in either total hip or hemi-hip replacement and is indicated for the following:

    Total Hip Replacement

    Severe hip pain and disability due to rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis, collagen disorders, avascular necrosis of the femoral head, nonunion of previous fractures of the femur; congenital hip dysplasia, protrusio acetabuli, slipped capital femoral epiphysis; disability due to previous fusion; previously failed endoprostheses, and acute femoral neck fractures.

    Hemi-Hip Replacement

    Fracture dislocation of the hip; elderly, debilitated patients when a total hip replacement is contraindicated; irreducible fractures in which adequate fixation cannot be obtained; certain high subcapital fractures and comminuted femoral neck fractures in the aged; nonunion of femoral neck fractures; secondary avascular necrosis of the femoral head; pathological fractures of the femoral neck; and osteoarthritis in which the femoral head is primarily affected.

    Device Description

    The Delta Hip Prosthesis is a collarless, modular femoral stem manufactured from either Tivanium or Ti-6A1-7Nb alloy both of which are high-fatigue strength materials with a history of successful clinical use and exceptional biocompatibility. Delta Hip stem sizes 9 through 15, 17 and 19 will be available in either material.

    The Delta Hip Prosthesis is designed for primary hip replacement in patients with a champagne flute type femur. The trapezoidal geometry provides for maximum metaphyseal fill of the proximal femur and apposition to cortical bone. Rotational stability is enhanced by the wedge fit of the stem in the proximal femur.

    The modular connection of the femoral stem is a Morse-type 12/14 neck taper designed to mate with the corresponding 12/14 bore of a femoral head component.

    AI/ML Overview

    The provided text is a "Summary of Safety and Effectiveness" for the Delta Hip Prosthesis, a medical device submission to the FDA. It does not contain information about acceptance criteria or a study proving the device meets acceptance criteria in the way typically expected for an AI/software-as-a-medical-device (SaMD) submission.

    Instead, this document describes a traditional medical device (a hip prosthesis) and focuses on demonstrating its substantial equivalence to previously cleared predicate devices. The "studies" mentioned are literature reports of successful clinical use of similar devices, not a specific performance study for the Delta Hip Prosthesis with defined acceptance criteria.

    Thus, I cannot fulfill the request as the information is not present in the provided text. The document is for a hardware medical device from 1996, and the questions posed are geared towards software/AI-based medical devices or clinical trials with specific endpoints, which are not applicable here.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1