510(k) Data Aggregation

    K Number
    K243729

    Validate with FDA (Live)

    Device Name
    Prismira
    Manufacturer
    Date Cleared
    2025-06-13

    (192 days)

    Product Code
    Regulation Number
    882.5803
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K231337, K233496

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Prismira is a digital therapeutic indicated to improve attention function in adults ages 22-55 years old with primarily inattentive or combined-type Attention Deficit and Hyperactivity Disorder (ADHD). Patients who engage with Prismira demonstrate improvements in a digitally assessed measure of sustained and selective attention, Test of Variables of Attention (TOVA), and may not display benefits in typical behavioral symptoms, such as hyperactivity.

    Prismira should be considered for use as part of a therapeutic program that may include clinician directed therapy, medication, and/or educational programs, which further address symptoms of the disorder.

    Device Description

    Prismira is software-as-a-medical device (SaMD) that resides on the user's mobile device and can be executed at home.

    Prismira is a prescription digital therapeutic indicated to improve attention function in patients 22 and older with primarily inattentive or combined type ADHD. Patients who engage with Prismira demonstrate improvements in attention functioning and may not display benefits in other behavioral symptoms such as hyperactivity. Prismira is intended to be used as part of a therapeutic program that may include clinician-directed therapy, medication, and/or educational programs, which further address symptoms of the disorder.

    The Prismira App also includes an Engagement System to promote compliance with the treatment. The Engagement System gives the patient encouragement and feedback on progress at multiple timescales: performance on the most recent gameplay and historical game performance, completion of the daily assignment, progress toward the weekly target in the current week, and historical assignment completion.

    Each game includes visual and optional auditory stimulus presentation. The basic input from the patient includes physical interaction with a touch screen accomplished by using the mobile device. The device's feedback within each game includes visual and optional auditory responses to the inputs. Output from each game includes a score earned by playing the game. Each gameplay is brief, typically between 1 and 5 minutes in duration, depending on the game. The treatment program guides patients through an ordered list of games (the "script") that enables subjects to engage in the recommended daily regimen (approximately 15 minutes per day).

    AI/ML Overview

    Here's a breakdown of the acceptance criteria and study details for the Prismira device, based on the provided FDA 510(k) clearance letter:

    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance Criteria (as implied by study success and substantial equivalence claims):

    • Primary Endpoint: Statistically significant improvement in TOVA ACS in the LLM-001 therapy arm compared to the control arm.
    • Safety: No new or increased safety risks compared to the predicate device, and a favorable safety profile with minimal adverse events.
    Metric / EndpointAcceptance Criteria (Implied)Reported Device Performance (Prismira / LLM-001)
    Primary Endpoint: TOVA ACS Change from Baseline at Day 63Statistically significant difference between active and control arms.- LLM-001 Change from Baseline Mean: 1.1 points (SD=3.6) - Control Change from Baseline Mean: 0.3 points (SD=3.6) - LSM Difference (LLM-001 - Control): 0.78 points (SE=0.32) - LSM Difference p-value: 0.0149 (statistically significant) - LSM improvement of 1.09 points was less than the recognized MCID of 1.4 points, but notably greater than the predicate device (0.93 points).
    Secondary Endpoint: CGI-IImprovement over control (desirable for clinical benefit).Superior clinical benefit for the LLM-001 arm over control (p=0.0087). (For LLM-001 subjects, 32.1% were assessed as "very much improved" on the CGI-I).
    Secondary Endpoint: ADHD-RS Total ScoreImprovement over control (desirable for clinical benefit).30.4% of LLM-001 subjects experienced greater than 30% reduction in their ADHD symptoms based on ADHD-RS total score. (Numerically favored LLM-001, but no statistically meaningful differences between groups for the continuous measure).
    Adverse Events (AEs)Minimal; no serious AEs; low treatment-related AE rate.- No serious adverse events reported. - Only two treatment-related AEs (frustration) out of 275 LLM-001 treated subjects (AE rate of 0.7%). - No subjects exited early for medical or gameplay-related complaints.
    Treatment ComplianceHigh, demonstrating feasibility of use.Mean of 874.7 minutes (97.2%) of 900 expected minutes.

    2. Sample Size and Data Provenance for the Test Set (Clinical Study)

    • Sample Size: 560 subjects were enrolled in The GAMES Study.
      • Safety Population: All 560 subjects.
      • Intent-to-Treat (ITT) Population: 456 subjects (224 randomized to LLM-001 active therapy, 232 to control therapy) who successfully completed gameplay treatment and Day 63 follow-up assessments.
    • Data Provenance: Not explicitly stated (e.g., country of origin). However, it was a "multi-center" clinical trial, suggesting diverse locations. It was a prospective, randomized, double-blind, parallel-group, sham-controlled clinical trial.

    3. Number of Experts and Qualifications for Ground Truth (Test Set)

    • The study used blinded clinicians to assess the CGI-I (Clinical Global Impression-Improvement), a global measure of clinical improvement.
    • Qualifications of Experts: Not explicitly stated beyond "blinded clinicians." Their expertise would be in diagnosing and assessing ADHD.

    4. Adjudication Method for the Test Set

    • The primary effectiveness measure (TOVA ACS) was a digitally assessed measure, so it wouldn't typically require human adjudication in the same way imaging studies might.
    • For the CGI-I, it was assessed by "blinded clinicians." This implies independent assessment rather than a consensus/adjudication process among multiple experts for each individual case's outcome on this specific measure. The "blinded" nature is the key control here.
    • There's no mention of a 2+1, 3+1, or other specific adjudication method for the clinical endpoints.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    • No, an MRMC comparative effectiveness study was not done. This type of study typically applies to diagnostic imaging devices where human readers interpret medical images with and without AI assistance.
    • This study was a randomized controlled clinical trial evaluating a digital therapeutic, focusing on its direct effect on patient outcomes (attention function) compared to a control.

    6. Standalone Performance Study

    • Yes, a standalone (algorithm only) performance study was done in the context of the clinical trial.
    • The "LLM-001 active therapy" arm represents the device's performance when used by the patient as intended, without direct human-in-the-loop interaction from the algorithm's perspective. The clinicians were involved in diagnosis and overall patient care, but the daily therapeutic delivery was directly from the device to the patient.
    • The primary endpoint, "change from baseline in the digitally assessed measure of sustained and selective attention, the Test of Variables of Attention (TOVA®)," is a direct measure of the algorithm's effect on attention function.

    7. Type of Ground Truth Used (Clinical Study)

    • The primary ground truth for effectiveness was derived from the Test of Variables of Attention (TOVA®) Attention Comparison Score (ACS), a digitally assessed, objective measure of sustained and selective attention. This is a standardized, quantitative neuropsychological assessment tool.
    • Secondary ground truths included:
      • ADHD-RS: ADHD Rating Scale, likely a clinician-rated symptom scale or patient-reported outcome.
      • CGI-I: Clinical Global Impression-Improvement, a clinician-assessed global measure of improvement.
      • BRIEF-A: Behavior Rating Inventory of Executive Function – Adult, likely a patient-reported or clinician-rated scale.
      • WFIRS-S: Weiss Functional Impairment Rating Scale – Self Report, a patient-reported outcome.
      • AAQoL: Adult ADHD Quality of Life Questionnaire, a patient-reported outcome.
    • Diagnosis of ADHD (combined or inattentive type) was confirmed using the Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5) criteria and confirmed by the Mini-International Neuropsychiatric Interview (MINI) for ADHD adult version.

    8. Sample Size for the Training Set

    • The document does not explicitly state the sample size for the training set used to develop the Prismira algorithm. The provided clinical study (The GAMES Study) is the pivotal validation study designed to test the already developed device.
    • The device description mentions an "Adaptive algorithm and Engagement System." Adaptive algorithms are often trained on large datasets, but the details of that training process and dataset size are not included in this 510(k) summary. References ¹ and ² hint at large-scale cognitive training data and online trials, which might relate to the algorithm's development.

    9. How Ground Truth for the Training Set Was Established

    • Similar to the training set sample size, the document does not explicitly describe how ground truth for the training set was established.
    • Given that it's an "adaptive algorithm," training data would likely involve cognitive performance metrics and potentially diagnostic information from previous patient populations. This could involve using standardized cognitive tests (like TOVA or similar measures) as the "ground truth" to train the algorithm to improve performance on those measures.
    Ask a Question

    Ask a specific question about this device

    K Number
    K233496

    Validate with FDA (Live)

    Device Name
    EndeavorOTC
    Date Cleared
    2024-06-14

    (228 days)

    Product Code
    Regulation Number
    882.5803
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K231337

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    EndeavorOTC is a digital therapeutic indicated to improve attention as measured by computer-based testing in patients 18 and older with primarily inattentive or combined type ADHD, who have a demonstrated attention issue. Patients who engage with EndeavorOTC demonstrate improvements in a digitally assessed measure, Test of Variables of Attention (TOVA®) of sustained and selective attention and may not display benefits in typical behavioral symptoms such as hyperactivity. EndeavorOTC is not intended to be a replacement for any form of treatment and should be used as part of a therapeutic program that may include clinician-directed therapy, medicational programs, which further address symptoms of the disorder.

    Device Description

    EndeavorOTC is software-as-a-medical device (SaMD) that resides on the user's mobile device and can be executed at home. It is an over-the-counter (OTC) digital therapeutic indicated to improve attention function as measured by computer-based testing in patients 18 and older with primarily inattentive or combined type ADHD, who have a demonstrated attention issue. Patients who engage with EndeavorOTC demonstrate improvements in a digitally assessed measure, Test of Variables of Attention (TOVA®) of sustained and selective attention and may not display benefits in typical behavioral symptoms such as hyperactivity. EndeavorOTC is not intended to be a replacement for any form of treatment and should be used as part of a therapeutic program that may include clinician-directed therapy, medication, and/or educational programs, which further address symptoms of the disorder. The device is built on Akili's proprietary, patented, technology platform. EndeavorOTC uses adaptive algorithms (also known as Selective Stimulus Management Engine, SSME™) to deliver stimuli that are designed to engage the patient in a manner that improves their attention function. In a closed-loop system, the adaptive SSME™ algorithms automatically adjust the difficulty level for a personalized treatment experience that is tailored to the needs of each individual patient. EndeavorOTC is delivered through a video game experience which leverages art, music, storytelling, and reward cycles to keep patients engaged. The adaptive algorithm constantly pushes patients precisely at predefined performance bounds relative to each individual, such that they are continuously encouraged to exceed their historic performance. The science behind EndeavorOTC was developed at the University of California, San Francisco by Adam Gazzaley, M.D., Ph.D., Founding Director of the University of California San Francisco's Neuroscape and Akili's Chief Science Advisor. The basic program inputs are steering, which is accomplished by using the mobile device's internal accelerometer to measure the degree to which it is tilted, and tapping, which is accomplished using the touch screen to measure correct and incorrect targeting. The basic outputs are the visual display of the game progression along with audio, which is accomplished by using the internal high resolution display and internal speaker. The program includes features to ensure it is used per the recommended regimen (approximately 25 minutes per day, 5 days per week, for 6 weeks).

    AI/ML Overview

    Here's a summary of the acceptance criteria and the study proving the EndeavorOTC device meets those criteria, based on the provided FDA 510(k) summary:

    Device Acceptance Criteria and Performance Study: EndeavorOTC

    Device Name: EndeavorOTC
    Regulatory Class: Class II
    Product Code: QFT
    Indication for Use: Digital therapeutic indicated to improve attention as measured by computer-based testing in patients 18 and older with primarily inattentive or combined type ADHD, who have a demonstrated attention issue.

    1. Table of Acceptance Criteria and Reported Device Performance

    The primary acceptance criteria for EndeavorOTC are based on demonstrating an improvement in attention, as measured by the Test of Variables of Attention (TOVA®) Attention Comparison Score (ACS), and showing a favorable safety profile in the indicated adult population. The 510(k) summary refers to "clinical performance study support[ing] the performance and safety of EndeavorOTC in the adult age range" and "a statistically significant positive mean change from baseline to study day 42 in the TOVA".

    Based on the provided document, the key efficacy performance criterion appears to be a statistically significant positive change in the TOVA-ACS.

    Acceptance Criteria (Implicit from Study Design & Outcomes)Reported Device Performance (STARS-Adult Study, K233496)
    Statistically significant positive change in TOVA-ACS from baseline to exitMean change in TOVA-ACS: 6.460 (SD 6.9522) 95% CI: [5.349, 7.570] P-value: < 0.0001 (Highly statistically significant)
    Favorable safety profile (low incidence of adverse events, no serious adverse events)Any TE-ADE: 11 (5.0%) of 221 subjects Most common TE-ADEs: Nausea (1.8%), Headache (1.4%), Decreased frustration tolerance (0.9%) Serious Adverse Device Events (SAEs): None reported Severity of TE-ADEs: All mild or moderate

    2. Sample Size and Data Provenance

    • Test Set (Clinical Study Population):
      • Safety Population (ITT): 221 participants
      • Efficacy Population (mITT): 153 participants (all enrolled subjects with sufficient data at baseline and exit to calculate change scores)
    • Data Provenance: The study was a "multicenter open-label study enrolled 221 subjects... across the US (a mix of institutional sites and private practice centers)." It was a prospective clinical performance study.

    3. Number of Experts for Ground Truth and Qualifications

    The provided document does not specify the number of experts used to establish the ground truth for the test set or their specific qualifications (e.g., "Radiologist with 10 years of experience").

    However, the diagnosis of ADHD was determined in study participants using the Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5) criteria as confirmed by the Mini-International Neuropsychiatric Interview (MINI) for ADHD adult version 7.0.2. This implies the involvement of trained clinicians (likely psychiatrists or psychologists) to administer and interpret these diagnostic tools. The TOVA® test itself is a standardized, computer-based assessment of attention.

    4. Adjudication Method for the Test Set

    The document does not describe a formal adjudication method (e.g., 2+1, 3+1) for the interpretation of the primary outcomes. The primary outcome (TOVA-ACS) is a quantitative, digitally assessed measure, which generally does not require traditional expert adjudication of results in the same way image interpretations might. The ADHD diagnosis was clinician-confirmed using standardized interviews.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    No, a multi-reader multi-case (MRMC) comparative effectiveness study was not explicitly mentioned or performed. This study was a single-arm, open-label study, primarily evaluating the device's effect on attention in the target population. It was not designed to compare human readers' improvement with or without AI assistance, as the device is a direct therapeutic intervention, not an AI-assisted diagnostic tool.

    6. Standalone (Algorithm Only) Performance

    EndeavorOTC is a therapeutic device (software-as-a-medical device) that directly interacts with the user as a game-like experience. Its performance is the algorithm's effect on the user's attention, measured by standardized tests like TOVA. Therefore, the clinical study results represent the standalone performance of the device's algorithm in a human-in-the-loop context (the human being the patient using the device). It's not an AI model that outputs a diagnostic interpretation for a human to review.

    7. Type of Ground Truth Used

    The primary ground truth for efficacy was objective, digitally assessed measures (Test of Variables of Attention - TOVA-ACS). The patient's ADHD diagnosis, which defined the study population, was established by clinician-administered standardized diagnostic interviews (MINI) based on DSM-5 criteria.

    8. Sample Size for the Training Set

    The document does not specify the sample size for the training set of the adaptive algorithms (Selective Stimulus Management Engine - SSME™). It notes that the science behind EndeavorOTC was developed at the University of California, San Francisco by Adam Gazzaley, M.D., Ph.D. The algorithms are "adaptive" and "in a closed-loop system, automatically adjust the difficulty level," implying continuous adaptation rather than a single, fixed training dataset in the typical machine learning sense.

    9. How Ground Truth for Training Set was Established

    Given that the device uses "adaptive algorithms (also known as Selective Stimulus Management Engine, SSME™) to deliver stimuli that are designed to engage the patient in a manner that improves their attention function," and adjusts difficulty "for a personalized treatment experience," the "ground truth" for the training of these adaptive algorithms is inherently tied to the patient's real-time performance within the game and their physiological responses or attentional engagement.

    The document does not detail how the initial parameters or underlying "training" for these adaptive algorithms were established. It mentions the algorithms were "developed at the University of California, San Francisco by Adam Gazzaley, M.D., Ph.D." This suggests a research-based, iterative development process informed by neuroscience and cognitive psychology, rather than a single, labeled dataset typical of supervised machine learning. The "ground truth" for fine-tuning the adaptive difficulty would likely be the user's performance and implicit learning within the game itself.

    Ask a Question

    Ask a specific question about this device