510(k) Data Aggregation

    K Number
    K250030

    Validate with FDA (Live)

    Date Cleared
    2025-04-28

    (112 days)

    Product Code
    Regulation Number
    892.1550
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K222648, K231190

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Flash Ultrasound System 5100 Point of Care (5100 POC and 5100 POC Pro) is indicated for diagnostic ultrasound imaging and fluid flow analysis of the human body, with the following indications for use:

    Abdominal, Adult Cephalic, Cardiac Adult, Cardiac Pediatric, Cerebral Vascular, Fetal/OB, Lung, Musculoskeletal (Conventional), Musculoskeletal (Superficial), Neonatal Cephalic, Ophthalmic, Other: Carotid, Other: GYN, Pediatric, Peripheral Vessel, Small Organ (Breast, Thyroid, Testicle), Trans-Esophageal (Cardiac), Trans-Vaginal.

    Modes of operation include B Mode (or 2D), Color Doppler, Color Power Angio Doppler, Continuous Wave Doppler, Pulse Wave Doppler, Tissue Doppler, M-Mode (including anatomical M-Mode), Harmonics (Tissue), and Combined modes.

    The clinical environments where the Flash Ultrasound System 5100 POC may be used are: hospitals, surgery centers, clinics, physicians' offices, diagnostic centers, critical care and emergency room environments, and point-of-care clinical settings for diagnosis of patients.

    The systems are intended to be installed, used, and operated only in accordance with the safety procedures and operating instructions given in the product user information. Systems are to be operated only by appropriately trained healthcare professionals for the purposes for which they were designed. However, nothing stated in the user information reduces the user's responsibility for sound clinical judgment and best clinical procedure.

    Device Description

    The Flash Ultrasound System 5100 Point of Care (POC) device is constructed with assets from the previously cleared 5000 Compact Series hardware platform (K222648) and a new Rhythm software platform that is new to the POC environment.

    The Flash Ultrasound System 5100 POC supports a full touch screen interface on the main display as the primary means of directing the system, leveraging customer familiarity with smart devices and the ease of cleaning and maintenance of a pure glass surface.

    Additionally, Flash Ultrasound System 5100 POC is designed to fit into tight spaces in a crowded Emergency Room (ER) with its small footprint, sleek design, and a large vertical tablet with ergonomic controls. The new Rhythm software offers point-of-contact workflow enhanced with assisted needle visualization, streamline point-of-care workflows such as flexible patient data management and AutoStrain EF. In addition to these POC workflows, the Rhythm software provides enhanced responsiveness with an easy-to-learn user interface as all controls are located in the same plane as the user's eye and hand for working more efficiently with the patient. The Flash Ultrasound System 5100 POC has two models, the 5100 POC and the 5100 POC Pro. The 5100 POC version does not support two transducers, C5-1 and X8-2t; however, the 5100 POC Pro supports all the transducers listed for the system.

    AI/ML Overview

    The provided FDA 510(k) clearance letter and summary for the Flash Ultrasound System 5100 Point of Care do not include detailed information about specific acceptance criteria related to its performance as a diagnostic imaging device (e.g., sensitivity, specificity, resolution), nor does it describe a study specifically designed to prove these performance metrics.

    Instead, the document focuses on demonstrating substantial equivalence to predicate devices through a combination of design features, intended use, fundamental scientific technology, and a comprehensive suite of non-clinical performance and safety testing.

    Here's an analysis based on the provided text, addressing the requested information to the extent possible:


    Acceptance Criteria and Study Proving Device Meets Criteria

    The submission primarily emphasizes compliance with recognized standards and verification testing against system and design specifications, rather than clinical performance metrics in a sense that would typically involve sensitivity, specificity, or human reader improvement with AI assistance.

    1. Table of Acceptance Criteria and Reported Device Performance

    Based on the provided text, the "acceptance criteria" are broad compliance with international standards and internal design specifications, and the "reported device performance" is that these criteria were met.

    Acceptance Criteria CategoryReported Device Performance
    Safety and EffectivenessDemonstrated through non-clinical performance testing and compliance with various IEC and ISO standards. All pre-determined acceptance criteria were met.
    System Level RequirementsAddressed according to system and design specifications.
    Risk Control MeasuresImplemented and verified through Risk Analysis and Risk Management activities (ISO 14971).
    Electromagnetic Compatibility (EMC)Complied with IEC 60601-1-2.
    UsabilityComplied with IEC 60601-1-6 and IEC 62366-1. User interface found safe and effective.
    Software Life Cycle ProcessComplied with IEC 62304.
    Ultrasonics Field Characterization (Thermal/Mechanical Indices)Complied with IEC 62359.
    BiocompatibilityNot needed as patient-contacting materials and manufacturing processes were not impacted, and common parts are used in other cleared systems.
    Design ControlsFollowed (Requirements Review, Risk Analysis, Product Specifications, Design Reviews, Verification).

    2. Sample Size Used for the Test Set and Data Provenance

    • Not explicitly stated for clinical performance. The document states: "The proposed Flash Ultrasound System 5100 POC did not require clinical data for determination of substantial equivalence." This implies that no clinical test set (patient data) was used in a comparative effectiveness study for this submission. The testing was primarily non-clinical.
    • Data Provenance: N/A for clinical performance. For non-clinical testing, the provenance would be internal Philips Ultrasound LLC laboratory testing.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications

    • Not applicable. Since clinical data was not required for substantial equivalence, there was no independent expert panel establishing ground truth on patient cases for performance evaluation.

    4. Adjudication Method for the Test Set

    • Not applicable. No clinical test set requiring adjudication was used.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was Done

    • No. The document explicitly states: "The proposed Flash Ultrasound System 5100 POC did not require clinical data for determination of substantial equivalence." Therefore, no MRMC study was conducted to evaluate human reader improvement with AI assistance (as AI assistance is not mentioned as a feature of the device's diagnostic performance, but rather "assisted needle visualization" is a workflow enhancement).

    • Effect size of human readers improve with AI vs without AI assistance: Not applicable, as no such study was performed or needed for this clearance. The "assisted needle visualization" is a feature mentioned, but its impact on reader performance is not quantified in this submission.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) was Done

    • Not applicable for diagnostic performance metrics. The device is an ultrasound system with various imaging modes and "assisted needle visualization." While there is a "new Rhythm software platform," the submission does not present it as a standalone diagnostic algorithm requiring performance metrics like sensitivity/specificity on its own. Its performance is integrated into the ultrasound system's overall functionality.

    7. The Type of Ground Truth Used

    • For non-clinical testing: The ground truth would be defined by the specifications and expected outputs of the system based on physical and engineering principles, verified through testing against known inputs or reference standards (e.g., phantom measurements, electrical signals, safety limits).
    • For diagnostic clinical performance: No clinical ground truth (e.g., expert consensus, pathology, outcomes data) was used or required for this 510(k) submission.

    8. The Sample Size for the Training Set

    • Not applicable. The submission does not describe the development or training of a de-novo AI algorithm that would require a "training set" in the context of generating diagnostic performance metrics. The "Rhythm software" is mentioned, and "assisted needle visualization" is a feature, but the document focuses on its equivalence and compliance, not on a machine learning training paradigm.

    9. How the Ground Truth for the Training Set was Established

    • Not applicable. As no training set for a diagnostic AI algorithm in the context of performance evaluation was described, the method for establishing its ground truth is not provided.
    Ask a Question

    Ask a specific question about this device

    K Number
    K233788

    Validate with FDA (Live)

    Date Cleared
    2024-02-13

    (77 days)

    Product Code
    Regulation Number
    892.1550
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    Why did this record match?
    Reference Devices :

    K231190; Philips EPIQ Series Diagnostic Ultrasound System

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    EPIQ:
    The intended use of EPIQ Ultrasound Diagnostic System is diagnostic ultrasound imaging and fluid flow analysis of the human body, with the following indications for use:

    Abdominal, Cardiac Adult, Cardiac other (Fetal), Cardiac Pediatric, Cerebral Vascular, Cephalic (Adult), Cephalic (Neonatal), Fetal/Obstetric, Gynecological, Intraoperative (Vascular), Intraoperative (Cardiac), intra-luminal, intra-cardiac echo, Musculoskeletal (Conventional), Musculoskeletal (Superficial), Ophthalmic, Other: Urology, Pediatric, Peripheral Vessel, Small Organ (Breast, Thyroid, Testicle), Transesophageal (Cardiac), Transvaginal, Lung.

    The clinical environments where EPIQ Series Diagnostic Ultrasound Systems can be used include clinics, hospitals, and clinical point-of-care for diagnosis of patients.

    When integrated with Philips EchoNavigator, the systems can assist the interventionalist and surgeon with image quidance during treatment of cardiovascular disease in which the procedure uses both live X-ray and live echo guidance.

    The systems are intended to be installed, used, and operated only in accordance with the safety procedures and operating instructions given in the product user information. Systems are to be operated only by appropriately trained healthcare professionals for the purposes for which they were designed. However, nothing stated in the user information reduces your responsibility for sound clinical judgement and best clinical procedure.

    Affiniti:
    The intended use of Affiniti Series Diagnostic Ultrasound Systems is diagnostic ultrasound imaging and fluid flow analysis of the human body, with the following indications for use:

    Abdominal, Cardiac Adult, Cardiac Other (Fetal), Cardiac Pediatric, Cerebral Vascular, Cephalic (Adult), Cephalic (Neonatal), Fetal/Obstetric, Gynecological, Intraoperative (Vascular), Intraoperative (Cardiac), Musculoskeletal (Conventional), Musculoskeletal (Superficial), Other: Urology, Pediatric, Peripheral Vessel, Small Organ (Breast, Thyroid, Testicle), Transesophageal (Cardiac), Transrectal, Transvaginal, Lung.

    The clinical environments where the Affiniti diagnostic ultrasound systems can be used include clinics, hospitals, and clinical point-of-care for diagnosis of patients.

    The systems are intended to be installed, used, and operated only in accordance with the safety procedures and operating instructions given in the product user information. Systems are to be operated only by appropriately trained healthcare professionals for the purposes for which they were designed. However, nothing stated in the user information reduces your responsibility for sound clinical judgement and best clinical procedure.

    Device Description

    The purpose of this Traditional 510(k) Pre-Market Notification is to introduce the Smart Doppler View ID software feature onto the EPIQ and Affiniti Series Diagnostic Ultrasound Systems.

    The purpose of the Smart Doppler View ID feature is to enhance the user's workflow through providing automation of the navigation of the touch screen groups on the Ultrasound System associated with Dopler Measurements. Without the Smart Doppler View ID feature, users must manually navigate to the desired Doppler Calculation Package Group on the Ultrasound System's various screens to perform a measurement. The Smart Doppler View ID feature automates this navigation and selects the associated calculation package group for the user based on the provided Doppler Spectrum acquired by the user using an artificial intelligence-based algorithm.

    Smart Doppler View ID maps to six Doppler Calculations Package groups on the Ultrasound System screen:

    • Aortic Valve
    • Mitral Valve
    • Tricuspid Valve
    • Pulmonic Valve
    • Venous Flow
    • TDI Vel (Tissue Doppler Imaging Velocity) & Ratio

    No hardware changes to the EPIQ or Affiniti systems are required when using the Smart Doppler View ID feature, and existing, commercialized Philips transducers are used for the Smart Doppler View ID feature.

    The feature is supported by all EPIQ and Affiniti models running software version 11.0 or higher including EPIQ CVx/CVxi, EPIQ Elite Advanced, EPIQ 7, EPIQ 5, Affiniti CVx, Affiniti 70, Affiniti 50, and Affiniti 30. The Smart Doppler View ID feature is associated with the cardiac adult indication.

    AI/ML Overview

    Here's a breakdown of the acceptance criteria and study details for the Smart Doppler View ID feature, based on the provided text:

    1. Acceptance Criteria and Reported Device Performance

    Acceptance CriteriaReported Device Performance
    Algorithm Accuracy97.5% (95% CI 96.3%, 98.3%), p-value < 0.0001

    2. Sample Size for Test Set and Data Provenance

    • Sample Size (Test Set): 1100 TTE (transthoracic echo) cardiac clips
    • Number of Subjects: 400 subjects
    • Data Provenance: Retrospective, collected from a US-based hospital.

    3. Number of Experts and Qualifications for Ground Truth Establishment

    • Number of Experts: 16 cardiac sonographers, and board-certified cardiologists.
    • Qualifications of Experts:
      • Cardiac Sonographers: Possessed a high level of expertise in acquiring Doppler TTE clips.
      • Board-Certified Cardiologists: Successfully passed the National Board of Echocardiography Examination and vetted and interpreted the studies.

    4. Adjudication Method for the Test Set

    The document does not explicitly describe a formal adjudication method (like 2+1 or 3+1). However, it states that the ground truth was "based on a group of measurements performed by intended users (i.e., Board certified cardiologists and cardiac sonographers) of the Ultrasound Systems as part of Standard of Care TTE exam per ASE guidelines at a large US-based hospital." This implies a consensus or expert-driven process for establishing the ground truth, but the specific mechanics of how disagreements were resolved are not detailed.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    The document does not indicate that a multi-reader multi-case (MRMC) comparative effectiveness study was done to compare human readers with and without AI assistance. The study focuses solely on the standalone performance of the AI algorithm in automatically detecting touchscreens.

    6. Standalone (Algorithm Only) Performance

    Yes, a standalone (algorithm only) performance study was done. The study evaluated the accuracy with which the Smart Doppler View ID algorithm could automatically recommend the correct Doppler Calculation Package group. The reported accuracy of 97.5% (95% CI 96.3%, 98.3%) refers to this standalone performance.

    7. Type of Ground Truth Used

    The ground truth used was expert consensus based on the "Standard of Care obtained group of measurements (touch screens)" and "measurements performed by intended users (i.e., Board certified cardiologists and cardiac sonographers) of the Ultrasound Systems as part of Standard of Care TTE exam per ASE guidelines." This ground truth was mapped to the appropriate touchscreen groups.

    8. Sample Size for the Training Set

    The document explicitly states: "The clinical performance study were completely distinct from that used during training of the algorithm, and there was no overlap between the two data sets." However, it does not provide the sample size for the training set.

    9. How the Ground Truth for the Training Set Was Established

    The document does not provide information on how the ground truth for the training set was established. It only mentions that the test set was distinct from the training set.

    Ask a Question

    Ask a specific question about this device