Search Filters

Search Results

Found 2 results

510(k) Data Aggregation

    K Number
    K252447

    Validate with FDA (Live)

    Date Cleared
    2025-10-01

    (58 days)

    Product Code
    Regulation Number
    878.4810
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K233007, K220268

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Picosecond Laser device is intended for use in surgical and aesthetic application in the medical dermatology and general and plastic surgery as follows:

    1064nm wavelength:

    • Removal of tattoos on all skin type (Fitzpatrick skin types I-VI) with the following tattoo colors: black, brown, green, blue and purple.
    • Treatment of benign pigmented lesions on Fitzpatrick skin types I-IV.

    532nm wavelength:

    • Removal of tattoos on Fitzpatrick skin types I-III with the following tattoo colors: red, yellow and orange.
    • Treatment of benign pigmented lesions on Fitzpatrick skin types I-IV.
    Device Description

    Composition of therapeutic device: main unit, light guide arm, handpiece and foot switch. The main unit includes display screen, laser, power supply, water circulation cooling system and electronic control components. Accessories include goggles, eye mask, standard hand tools, power cord, fuse tube, funnel component, drain faucet, user manual, remote control interlock connector, drain spout and keys.

    The Picosecond Laser Device is a multi-wavelength, pulsed laser system designed for the treatment of benign pigmented lesions and removal of tattoos. A key feature of the device is its ability to produce multiple laser wavelengths (1064 nm and 532 nm).

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K250041

    Validate with FDA (Live)

    Date Cleared
    2025-05-14

    (126 days)

    Product Code
    Regulation Number
    878.4810
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K233007, K220268

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Medical Picosecond ND:YAG Laser System is intended for use in surgical and aesthetic application in the medical dermatology and general and plastic surgery as follows:

    1064nm wavelength:

    • Removal of tattoos on all skin type (Fitzpatrick skin types I-VI) with the following tattoo colors: black, brown, green, blue and purple.
    • Treatment of benign pigmented lesions on Fitzpatrick skin types I-IV.

    532nm wavelength:

    • Removal of tattoos on Fitzpatrick skin types I-III with the following tattoo colors: red, yellow and orange.
    • Treatment of benign pigmented lesions on Fitzpatrick skin types I-IV.
    Device Description

    The Medical Picosecond ND: YAG Laser System mainly consists of a host, a light guide arm, a treatment handle, a foot switch, a power cord, and other auxiliary treatment accessories. The host mainly includes laser power supply, laser, water circulation cooling system, control board, and display screen. Accessories include a foot switch, laser protective glasses, power cords, and a water filling funnel.

    The Medical Picosecond ND: YAG Laser System is a multi-wavelength, pulsed laser system designed for the treatment of benign pigmented lesions. A key feature of the device is its ability to produce multiple laser wavelengths (1064 nm and 532 nm).

    AI/ML Overview

    I am sorry, but the provided FDA 510(k) clearance letter for the Medical Picosecond ND: YAG Laser System (PZ-6) does not contain the information requested regarding acceptance criteria and a study proving the device meets those criteria.

    Specifically, the document states:

    • "No clinical study is included in this submission." (Page 11, Section 8.0 Clinical Test Conclusion)
    • The "Non clinical tests were conducted to verify that the subject devices met all design specifications as were Substantially Equivalent (SE) to the predicate device." (Page 11, Section 7.0 Non-Clinical Test Conclusion) These non-clinical tests relate to compliance with various IEC and ISO standards for medical electrical equipment, laser safety, and biocompatibility, as well as software validation. These are not performance acceptance criteria for the intended use (tattoo and lesion removal) in the way you are asking.

    Therefore, I cannot provide the detailed information requested in your prompt as it is not present in the provided text.

    Ask a Question

    Ask a specific question about this device