Search Filters

Search Results

Found 3 results

510(k) Data Aggregation

    K Number
    K251497

    Validate with FDA (Live)

    Date Cleared
    2025-10-16

    (154 days)

    Product Code
    Regulation Number
    872.3630
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K151455, K011394, K150704, K201860

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Elos Accurate® Hybrid Base™ is intended for attaching to dental implants in order to provide basis for single or multiple tooth prosthetic restorations. The Hybrid Base™ is used as an interface between a dental implant and a zirconia superstructure and will be attached to the implant using a prosthetic screw and attached to the zirconia superstructure by cementing.

    The Elos Accurate® Hybrid Base™ is compatible with the implant systems listed in table 1:

    Table 1:

    Implant Platform compatibilityPlatform diameter [mm]Implant Body diameter [mm]
    Nuventus NV.C NPØ3.5Ø3.5 / Ø4.3
    Nuventus NV.C RPØ5.0Ø5.0

    The zirconia superstructures for use with the Elos Accurate® Hybrid Base™ are either intended to be sent and manufactured at a FDA registered Elos Medtech approved milling facility or to be designed and manufactured according to digital dentistry workflow. The workflow system integrates multiple components of the digital dentistry workflow: scan files from Intra-Oral Scanners, CAD software, CAM software, ceramic material milling machine and associated tooling and accessories.

    Device Description

    The Elos Accurate® Hybrid Base™ is intended for attaching to dental implants in order to provide basis for single or multiple tooth prosthetic restorations. The Hybrid Base™ functions as an interface between a dental implant and a zirconia superstructure. It attaches to the implant using the included prosthetic screw and connects to the zirconia superstructure through cementing. The Elos Accurate® Hybrid Base™ is a two-piece abutment composed of the Hybrid Base as the bottom-half and the zirconia superstructure as the top-half, which when assembled comprises the final finished medical device.

    The Elos Accurate® Hybrid Base™ is available for two types: Engaging and Non-Engaging

    • The Hybrid Base™ Engaging which is intended for single tooth dental restorations and having an indexing feature, which avoid the Hybrid Base from rotating in the implant.
    • The Hybrid Base™ Non-Engaging is intended for multiple tooth dental restorations and has no indexing feature, which allows the Hybrid Base to rotate in the implant.

    The Elos Accurate® Hybrid Base™ is available with 4 different collar heights and is provided with a 7.5mm chimney which can be cut down to several heights by the user, to minimum 3.5 mm.

    The Elos Accurate® Hybrid Base™ consists of a pre-manufactured prosthetic component in Titanium alloy per ASTM F136, as well as supporting digital library file for 510(k) cleared design software (3Shape Abutment Designer™ Software, K151455) which facilitates the design of a patient specific zirconia superstructure by the laboratory/clinician. The Elos Accurate® Hybrid Base™ fits directly to an endosseous dental implant. The laboratory designed superstructure is manufactured from 510(k) cleared Zirconia (Lava Plus, K011394) according to digital dentistry workflow. For all Elos Accurate® Hybrid Base™ models the zirconia superstructure must be designed according to following limits:

    Hybrid Base abutments (zirconia part):
    Min. wall thickness 0.5 mm
    Gingival height min. 0.5mm or max. 5 mm
    Max. angulation 20°
    Min. post height* 4 mm

    *The post height is defined as the cementable height of the abutment.

    The laboratory designed superstructure is attached to the Elos Accurate® Hybrid Base by use of 510(k) cleared cement (Panavia V5, K150704) and the final prosthetic restoration is attached to the implant using a Prosthetic screw.

    The Prosthetic Screw, also made of Titanium Alloy (ASTM F136), provided for the Elos Accurate® Hybrid Base™ is used to secure the final prosthetic restoration to the implant in the patient's mouth. The Prosthetic Screws have a hexalobular driver connection interface. The driver intended to be used with the Elos Accurate® Hexalobular Prosthetic Screws is the Elos Prosthetic Screwdriver 18mm, 26mm or 34mm (Ref. No. 042.0018, 042.0026 or 042.0034). These screwdrivers are Class I Exempt devices per FDA product code NDP.

    The Elos Accurate® Hybrid Base has a gold anodized surface to increase the esthetics of the dental restoration - the same surface as in predicate device K242025.

    The subject prosthetic screws are provided are either non-coated or surface coated with DLC (identical to the DLC coating in reference device K201860).

    The Elos Accurate® Hybrid Base™ and the Prosthetic screw is delivered non-sterile, and the final restoration and corresponding screw is intended to be sterilized at the dental clinic before it is placed in the patient. The recommended sterilization procedure is full cycle pre-vacuum steam sterilization at a temperature of 132 °C (270°F) for 4 minutes. Dry time: 20 minutes.

    The Elos Accurate® Hybrid Base™ is packed in 1 pc. packaging with the Elos Accurate® Hexalobular Prosthetic screw. The Screw is also available packed alone in 1 pcs packaging.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K221301

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2023-03-09

    (308 days)

    Product Code
    Regulation Number
    872.3630
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K201860, K180703, K130436, K151455

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    DESS Dental Smart Solutions abutments are intended to be used in conjunction with endosseous dental implants in the maxillary or mandibular arch to provide support for prosthetic restorations.

    All digitally designed custom abutments for use with DESS Bases or Pre-milled Blanks are to be sent to a Terrats Medical validated milling center for manufacture, or to be designed and manufactured according to the digital dentistry workflow integrates multiple components: scan files from intra-oral and lab (desktop) scanners, CAM software, ceramic material, milling machine, and associated tooling and accessories.

    Device Description

    The purpose of this submission is to expand the DESS Dental Smart Solutions abutment system cleared under K22288 to add the ability for the subject device Base Abutments and Pre-milled (Blank) Abutments to be manufactured via a digital dentistry workflow by using scan files from intra-oral and lab (desktop) scanners, CAD software, CAM software, ceramic material, milling machine and associated tooling and accessories. There are no changes to the abutment design or implant compatibilities, however, there is a new material for the zircomia superstructure. All part numbers have been cleared within previous submissions for manufacturing at a validated milling center. The purpose of this submission is to allow manufacturing via digital dentistry workflow and to add a new zirconia material for the superstructures of the two-piece abutment.

    The subject device DESS Dental Smart Solutions abutments provide a range of prosthetic solutions for dental implant restoration. DESS abutments are offered in a variety of connection types to enable compatibility with currently marketed dental implants. All abutments are provided non-sterile, and each abutment is supplied with the appropriate abutment screw (if applicable) for attachment to the corresponding implant.

    Subject device Base Abutments are designed for fabrication of a patient-specific CAD/CAM zirconia superstructure on which a crown may be placed. They are two-piece abutments for which the second part (or top half) is the ceramic superstructure. They also may be used for support of a crown directly on the abutment.

    All patient-specific custom abutment fabrication for Base Abutments and Pre-milled (Blank) Abutments is by prescription on the order of the clinician. The subject device Pre-milled (Blank) Abutments and all zirconia superstructures for use with the subject device Ti Base Interface, DESS Aurum Base, ELLIPTIBase, and DESS C-Base will be manufactured using a digital dentistry workflow by using scan files from intra-oral and lab (desktop) scanners, CAD software, CAM software, ceramic material, milling machine and associated tooling and accessories.

    The digital dentistry workflow uses scan files from intra-oral and lab (desktop) scanners, CAD software, CAM software, ceramic material, milling machine and associated tooling and accessories.

    AI/ML Overview

    The provided text is a 510(k) summary for a dental device, specifically DESS Dental Smart Solutions abutments. It focuses on demonstrating substantial equivalence to predicate devices rather than proving performance against specific acceptance criteria for an AI/ML-based device.

    Therefore, I cannot provide the requested information as the document does not contain details about:

    • Acceptance criteria for an AI/ML device: This document is about dental implant abutments, not a medical device driven by AI/ML.
    • Study proving device meets acceptance criteria: There is no performance study described for an AI/ML component. The "Performance Data" section refers to non-clinical data for biocompatibility and fatigue testing of the physical dental abutments, and software verification to ensure design parameters are met and restriction zones are locked, not AI/ML performance.
    • Sample size for test set and data provenance: Not applicable to a non-AI/ML device.
    • Number of experts and their qualifications for ground truth: Not applicable.
    • Adjudication method for the test set: Not applicable.
    • Multi-reader multi-case (MRMC) comparative effectiveness study: Not applicable.
    • Standalone (algorithm only) performance: Not applicable.
    • Type of ground truth used: Not applicable.
    • Sample size for training set: Not applicable.
    • How ground truth for training set was established: Not applicable.

    The document describes the physical characteristics, materials, manufacturing processes (including digital dentistry workflows), and compatibility of the dental abutments, and asserts their substantial equivalence to previously cleared devices. It does not mention any AI/ML components or their performance evaluation.

    Ask a Question

    Ask a specific question about this device

    K Number
    K222044

    Validate with FDA (Live)

    Date Cleared
    2022-11-30

    (142 days)

    Product Code
    Regulation Number
    872.3630
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K201860, K151455

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Elos Accurate® Customized Abutments are intended for attaching to dental implants in order to provide basis for single or multiple tooth prosthetic restorations. The Elos Accurate® Customized Abutment will be attached to a dental implant using the included Elos Prosthetic screw.

    Device Description

    The Elos Accurate® Customized Abutment is a patient specific abutment intended for attaching to dental implants in order to provide basis for single- or multiple tooth prosthetic restorations. The Elos Accurate® Customized Abutment will be attached to the implant using the included Elos Prosthetic Screw and attached to the crown/coping manually by cementation. The Elos Accurate® Customized Abutment consists of an Abuttnent Blank used in fabricating of a full patient-specific abutment in Titanium alloy per ASTM F136. The Abutment Blank used in creation of the Elos Accurate® Customized Abutment has a pre-manufactured connection interface that fits directly to a pre-specified dental implant. The customized shape of the abutment is intended to be manufactured according to a digital dentistry workflow. The Elos Accurate® Customized Abutment is delivered non-sterile and the final restoration including corresponding Elos Prosthetic Screw is intended to be sterilized at the dental clinic before it is placed in the patient. The Elos Accurate® Customized Abutment provides clinicians and laboratories with a prosthetic device that can be used in definitive (permanent) single- or multi restorations.

    AI/ML Overview

    The provided text describes the regulatory clearance of a dental abutment, not an AI/ML medical device. Therefore, it does not contain information about acceptance criteria or a study proving that an AI/ML device meets those criteria.

    The 510(k) summary focuses on demonstrating "substantial equivalence" of the Elos Accurate® Customized Abutment to previously cleared predicate devices. The non-clinical testing described is for the physical dental device itself (e.g., fatigue testing, biocompatibility, sterilization validation) and validation of the digital dentistry workflow for designing and manufacturing the abutment.

    There is no mention of:

    • Acceptance criteria in terms of AI/ML performance metrics (e.g., sensitivity, specificity, AUC).
    • A test set, training set, or data provenance for an AI/ML algorithm.
    • Experts establishing ground truth for AI/ML performance.
    • Adjudication methods for AI/ML.
    • Multi-reader multi-case (MRMC) comparative effectiveness studies.
    • Standalone algorithm performance studies.
    • Ground truth types related to AI/ML (e.g., pathology for image classification).

    The "digital dentistry workflow validation" mentioned refers to the software (3Shape Abutment Designer Software) that provides design limits for the abutment, not an AI/ML algorithm that performs a diagnostic or predictive task. It essentially ensures the software's constraints prevent users from designing abutments outside safe parameters.

    Therefore, I cannot extract the requested information about AI/ML device acceptance criteria and study details from the provided document. The document is for a traditional medical device (dental abutment) and its manufacturing workflow, not an AI/ML enabled device.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1