510(k) Data Aggregation

    K Number
    K242008

    Validate with FDA (Live)

    Device Name
    Coronis OneLook
    Manufacturer
    Date Cleared
    2024-08-02

    (23 days)

    Product Code
    Regulation Number
    892.2050
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K191845, D332294

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The display is intended to be used in displaying and viewing digital images, including standard and multiframe digital mammography, for review, analysis and diagnosis by trained medical practitioners. It is especially designed for breast tomosynthesis (3D mammography) applications, breast MRI and breast US. It is especially designed for CT and ultrasound including vascular and gynaecological US.

    Device Description

    The Coronis OneLook® (MDMC-32133) is a medical computer display designed for general radiology, mammography and tomosynthesis applications. The device can also be used for home reading in radiology.

    The display is a high-resolution LCD monitor with improved technical chat are important for accurate medical image review: high luminance, good luminance ratio and luminance ratio and luminance stability. The medical display comes with special image-enhancing technologies to ensure consistent brightne of the display, noise-free images (=good luminance uniformity), ergonomic reading and automated compliance with DICOM and other medical image quality standards and guidelines. These technologies help the radiologist to make a swift and accurate diagnosis.

    The displays can be used optionally with the downloadable QAWeb Enterprise software, listed under D332294 as a class 1 device with product code LHO. QAWeb Enterprise is a calibration software that is intended as a quality assurance software for the displays. QAWeb Enterprise software helps to keep the display DICOM compliant.

    The display can be used optionally with the downloadable Intuitive Workflow Tools, cleared in K191845 as a class 2 device with product code PGY. The Intuitive Workflow Tools are accessories for image enhancement on diagnostic displays:

    • SpotView: The Barco SpotView display feature allows focusing on a region of interest in an image by boosting the display's backlight such that the maximum luminance in provided inside the region of interest. SpotView also enables focused observation during reading by dimming images outside the region of increasing the contrast in this region. Also magnification and inversion of pixels are possible with SpotView.

    -AAM – Application Appearance Manager: This workflow tool allows you to set the luminance as well as the color space for each application that is on the workstation. There are often multiple windows open on a screen, but not all of them need the hightness

    These applications are addressed by the general term 'Intuitive Workflow Tools'. The integration of the Intuitive Workflow Tools with the displays have been de-risked, verified and validated to ensure that they do not affect the safety and effectiveness of the displays.

    The display can be used with or without the Barco MXRT display controller boards. The display controller board is installed in a PACS workstation computer, connected to the display can optionally be used with a touchpad, which is a controlling device (e.g. like a mouse or trackball) that makes it easier to work with diagnostic images and to use the IWTs.

    AI/ML Overview

    The provided text describes a 510(k) premarket notification for a medical display device, Coronis OneLook (MDMC-32133). The document primarily focuses on demonstrating substantial equivalence to a predicate device (MDMC-12133, Coronis Uniti) through bench testing of technical characteristics.

    Here is an analysis of the acceptance criteria and the study that proves the device meets them, based on the provided text:

    1. Table of Acceptance Criteria and Reported Device Performance:

    The document outlines a series of performance bench tests conducted on the MDMC-32133 in comparison to the MDMC-12133, referencing the "Guidance for Industry and FDA Staff: Display Devices for Diagnostic Radiology" (2022). The text generally states that the MDMC-32133 has "similar characteristics" and "did not reveal new issues of safety and performance." However, it does not provide specific numerical acceptance criteria or detailed quantitative reported performance values for each characteristic. Instead, it concludes equivalence based on these test outcomes.

    Acceptance Criteria (Bench Test Category)Reported Device Performance (MDMC-32133 vs. MDMC-12133)
    Spatial resolution – MTFSimilar characteristics; no new safety/performance issues.
    Pixel defects (Maximum counts, allowed defect types, and locations)Similar characteristics; no new safety/performance issues.
    ArtifactsSimilar characteristics; no new safety/performance issues.
    Temporal ResponseSimilar characteristics; no new safety/performance issues.
    Luminance (maximum, minimum, achievable and recommended)1200 Nit Calibrated light output (MDMC-32133) compared to 1000 Nit (MDMC-12133). Overall similar characteristics; no new safety/performance issues.
    Luminance responseSimilar characteristics; no new safety/performance issues.
    Conformance to DICOM GSDFSimilar characteristics; no new safety/performance issues.
    Angular Dependency of LuminanceSimilar characteristics; no new safety/performance issues.
    Luminance uniformity or Mura test (Luminance & Chromaticity Uniformity)Similar characteristics; no new safety/performance issues.
    RMS (image variance) for multiple video levelsSimilar characteristics; no new safety/performance issues.
    Stability of luminance and chromaticity response with temperature and time of operation or on-timeSimilar characteristics; no new safety/performance issues.
    Spatial noiseSimilar characteristics; no new safety/performance issues.
    Reflection coefficient Display Reflectance incl. Specular and Diffuse coefficientsSimilar characteristics; no new safety/performance issues.
    Veiling glare or small-spot contrastSimilar characteristics; no new safety/performance issues.
    Color tracking (primary colors and color gamut)Similar characteristics; no new safety/performance issues.
    Gray tracking (gray shaded and color gamut)Similar characteristics; no new safety/performance issues.
    EMC and Safety Standards ComplianceCompliant.
    Environmental Tests (climate, mechanical, software)Passed.

    2. Sample Size Used for the Test Set and Data Provenance:

    The document describes "performance bench tests" that were performed. This implies testing on physical units of the device. It does not specify the sample size (number of devices tested) for these bench tests. The data provenance is not explicitly mentioned as retrospective or prospective in the context of data used for testing, but rather refers to the device characteristics under comparison.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications:

    This information is not applicable as the study described is purely a technical bench test comparison of display performance, not a study involving human interpretation of medical images or establishment of ground truth for medical diagnoses.

    4. Adjudication Method for the Test Set:

    This information is not applicable for the reasons stated in point 3.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done:

    No, an MRMC comparative effectiveness study was not done. The document explicitly states: "No animal testing or clinical testing has been performed." The study focuses on technical characteristics of the display itself, not on the effectiveness of human readers using the display for diagnosis.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done:

    This is not applicable in the context of an algorithm's performance, as the device is a medical display, not an AI algorithm. The performance evaluation is for the display's technical specifications.

    7. The Type of Ground Truth Used:

    The "ground truth" for this type of test is typically established by industry standards and specifications for display performance, as well as the performance of the legally marketed predicate device (MDMC-12133). The tests are designed to measure intrinsic physical properties of the display hardware against these established benchmarks.

    8. The Sample Size for the Training Set:

    This information is not applicable as the device is a display hardware, not an AI model that requires a training set.

    9. How the Ground Truth for the Training Set Was Established:

    This information is not applicable for the reasons stated in point 8.

    Ask a Question

    Ask a specific question about this device

    K Number
    K233693

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2023-12-11

    (24 days)

    Product Code
    Regulation Number
    892.2050
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K191845

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The display is intended to be used for displaying and viewing digital images (excluding digital mammography) for review and analysis by trained medical practitioners.

    Device Description

    The No Color 8MP (MDNC-8132) is a medical computer display designed for general radiology applications. The device can also be used for home reading in radiology. The display is a high-resolution LCD monitor with characteristics that are important for accurate medical image review: high luminance, good luminance uniformity, good luminance stability. The medical display comes with special image-enhancing technologies to ensure consistent brightness over the display, noise-free images (=good luminance uniformity), ergonomic reading and automated compliance with DICOM and other medical image quality standards and guidelines. These technologies help the radiologist to make a swift and accurate diagnosis. The displays can be used optionally with the downloadable QAWeb Enterprise software, listed under D332294 as a class 1 device with product code LHO. QAWeb Enterprise is a calibration software that is intended as a quality assurance software for the displays. QAWeb Enterprise software helps to keep the display DICOM compliant. The display can be used optionally with the downloadable Intuitive Workflow Tools, cleared in K191845 as a class 2 device with product code PGY. The Intuitive Workflow Tools are accessories for image enhancement on diagnostic displays: SpotView and AAM – Application Appearance Manager. The display can be used with or without the Barco MXRT display controller boards.

    AI/ML Overview

    The provided document is a 510(k) summary for the Barco Nio Color 8MP (MDNC-8132) medical display. It details the device, its intended use, and a comparison to a predicate device (Nio Color 2MP, MDNC-2521) to demonstrate substantial equivalence.

    Based on the information provided, here's an analysis of the acceptance criteria and the study proving the device meets them:

    Crucially, this document does not describe a study involving AI or human reader performance. It describes a comparison of a medical display device to a predicate device based on technical specifications and bench testing. Therefore, many of the requested points related to AI, human readers, ground truth establishment, and training sets are not applicable to this submission.


    Acceptance Criteria and Reported Device Performance

    The acceptance criteria for this device appear to be based on demonstrating "similar characteristics" and "equivalence" to the predicate device MDNC-2521 across various physical and performance metrics for a medical display. The general acceptance is that the modifications "did not reveal new issues of safety and performance" compared to the cleared predicate device.

    Table of Acceptance Criteria and Reported Device Performance

    Acceptance Criteria (Bench Test Category)Reported Device Performance (MDNC-8132 vs. MDNC-2521)
    Spatial resolution MTF"similar characteristics" / "equivalent"
    Pixel defects, Artifacts"similar characteristics" / "equivalent"
    Temporal Response"similar characteristics" / "equivalent"
    Maximum and Minimum Luminance"similar characteristics" / "equivalent"
    Luminance response, Conformance to DICOM GSDF"similar characteristics" / "equivalent"
    Angular Dependency of Luminance"similar characteristics" / "equivalent"
    Luminance uniformity"similar characteristics" / "equivalent"
    Reflection coefficient Display Reflectance incl. Specular, Diffuse & Haze coefficients"similar characteristics" / "equivalent"
    Veiling glare or small-spot contrast"similar characteristics" / "equivalent"
    Color tracking"similar characteristics" / "equivalent"
    EMC and Safety standards complianceCompliant
    Environmental tests (climate, mechanical, software)Passed

    Study Details (as applicable to a medical display submission, not AI)

    Given that this is a submission for a medical display device demonstrating substantial equivalence to a predicate, and not an AI/software as a medical device (SaMD), the following points are largely not applicable or interpreted within the context of hardware testing.

    1. Sample size used for the test set and the data provenance:

      • The test set consists of the Barco Nio Color 8MP (MDNC-8132) device itself. The "sample size" is essentially n=1 (one type of device being tested). There isn't a "data set" in the traditional sense of medical images or patient data.
      • Data provenance: Not applicable in the sense of patient data. The tests were performed on the physical device as per "Guidance for Industry and FDA Staff: Display Devices for Diagnostic Radiology", issued in 2022.
    2. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

      • Not applicable. There is no "ground truth" to be established by experts in the context of diagnostic performance on images, as this is a display device. The "truth" here is whether the display's physical and photometric characteristics meet predetermined engineering and regulatory standards (e.g., DICOM GSDF conformance) and are equivalent to the predicate. This is typically verified by specialized testing equipment and procedures.
    3. Adjudication method (e.g. 2+1, 3+1, none) for the test set:

      • Not applicable. Adjudication is relevant for expert agreement on medical findings, not for objective physical measurements of a display.
    4. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

      • No, this was not done. This is a submission for a medical display, not an AI device. The document explicitly states: "No animal testing or clinical testing has been performed."
    5. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

      • No, this was not done. This is a display device, not an algorithm.
    6. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

      • Not applicable in the medical context. The "ground truth" for this device's performance are the established technical specifications and performance characteristics outlined in industry standards (like DICOM) and the FDA guidance for display devices. The comparison is made against the performance of a legally marketed predicate device.
    7. The sample size for the training set:

      • Not applicable. This device does not use a "training set" as it is a hardware display, not an AI algorithm.
    8. How the ground truth for the training set was established:

      • Not applicable. (See point 7).

    Summary of the Study:

    The study proving the device meets the acceptance criteria is a series of bench tests conducted on the Nio Color 8MP (MDNC-8132) display. These tests were performed according to the "Physical Laboratory Testing instructions in 'Guidance for Industry and FDA Staff: Display Devices for Diagnostic Radiology'" (2022). The purpose was to demonstrate that the MDNC-8132 possesses "similar characteristics" and is "equivalent" in performance to the predicate device, the Nio Color 2MP (MDNC-2521), across various critical display parameters such as spatial resolution, luminance, uniformity, reflection, and color tracking. The document concludes that these tests "did not reveal new issues of safety and performance" and confirmed its substantial equivalence to the predicate. Additionally, compliance with EMC and Safety standards, and passing environmental tests, contributed to the conclusion of substantial equivalence. No clinical or animal testing was performed, as the
    demonstration of equivalence was based solely on technical and performance bench testing.