510(k) Data Aggregation

    K Number
    K240143

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2024-10-11

    (267 days)

    Product Code
    Regulation Number
    872.3640
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K210356, K152093, K052885, K173343, K182081

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    JDZygoma Dental implant is a JDentalCare implant system.

    JDZygoma Dental implant System is intended to be implanted in the upper jaw arch to provide support for fixed or removable prosthetic devices in patients with partially or fully edentulous maxilla, in order to restore patient esthetics and chewing function.

    The JDZygoma Implants are appropriate for immediate loading when good primary stability is achieved and with appropriate occlusal loading.

    Device Description

    JDZygoma dental implants are implantable devices produced in commercially pure titanium, intended to be integrated in the Zygomatic bone to support prosthetic devices, such as artificial teeth, in order to restore chewing function.

    The JDZygoma implant bodies are single use, gamma sterilized devices that shall be used by qualified medical personnel. The abutments are supplied non sterile and must be sterilized prior to use.

    The JDZYGOMA DENTAL IMPLANTS includes 2 lines of devices with different body diameters of implants (3.9 mm and 4.3 mm) with different implant lengths:

    • Diameter(mm) 3.9 Lengths (mm): 30 / 35 / 37.5 / 40 / 42.5 / 45 / 47.5 / 50 / 52.5 / 55 / 57.5 ●
    • Diameter(mm) 4.3 Lengths (mm): 30 / 35 / 37.5 / 40 / 42.5 / 45 / 47.5 / 50 / 52.5 / 55 / 57.5 .

    The surfaces JDZYGOMA DENTAL IMPLANTS, both 3.9 mm and 4.3 mm of diameter, is machined in the distal part of the fixture while the apical part, the threaded part, is characterized by a surface that is a SLA surface obtained through a sandblasting process followed by acid etching.

    Machined surface has been analyzed form a morphological point of view using scanning electron microscope (SEM) with different level of magnification (100x, 500x, 1000x and 250x) and also performing a 3D analysis, that allow to define roughness profile with an average height of selected area (Sa) equal to 0.64 um, with a Root mean square gradient (Sdq) of 1.06 and a developed interfacial area ratio (Sdr) of 47.64%.

    The abutments are made of titanium grade 5 and have the following angulations:

    • . 45° 52.5° and 60°
      The connection implant / abutment is done through an internal hexagon.

    The conical abutments surface is completely treated with anodic oxidation resulting in perception of yellow color.

    The anodization process is performed by immersing the anodization solution and by providing an electrical voltage for a time necessary to activate the process with the material (titanium grade 5) and then performing washing process and drying the devices.

    The result of this process has been evaluated from a morphological point of view using scanning electron microscope (SEM), measuring the roughness parameters and performing qualitative analysis of the chemical composition of the abutments surface with X-Ray detector considering and comparing both a non anodized abutments and the same anodized abutments in their finished forms.

    These evaluations show a relatively uniform surface with characteristic textures of typical machined titanium, clean and free from significant residues or contaminants, with a morphology of the surface before and after anodization that doesn't show appreciable differences also for roughness and X-ray analysis identify a presence of only of Ti, Al, V, O, as expected.

    AI/ML Overview

    The provided text is a 510(k) summary for the JDZygoma dental implants, which is a medical device. This type of document is a submission to the FDA demonstrating that the device is as safe and effective as a legally marketed predicate device. The information required in the prompt (acceptance criteria, study details, etc.) is typically found in performance studies used to support substantial equivalence.

    Here's a breakdown of the requested information based on the provided text:

    1. A table of acceptance criteria and the reported device performance

    The document does not explicitly present a table of acceptance criteria for specific performance metrics with corresponding reported values in a pass/fail format. However, it describes several performance tests and their outcomes:

    Performance Test / Criterion TypeReported Device Performance (Implied Acceptance)
    BiocompatibilityConducted according to ISO 10993-1:2018 and ISO 10993-5. (Implies compliance with these standards, meaning the device is biocompatible).
    Washing ProcessDemonstrated that no residual substances were present on implant or abutment surface. (Implies successful cleaning and absence of harmful residuals).
    Packaging Shelf LifeAccelerated aging testing conducted according to ISO 11607-1. (Implies meeting the shelf-life requirements of this standard).
    Mechanical FatigueComparative mechanical fatigue testing was performed according to a method modified from ISO 14801. Results confirm that fatigue performances of the subject device are comparable to or better than both predicate and reference Devices. (Implies the device meets or exceeds the mechanical durability of predicate/reference devices).
    Gamma Ray SterilizationValidation in accordance with ISO 11137-1:2006 and ISO 11137-2: 2013. (Implies effective sterilization and compliance with these standards).
    Endotoxin TestsPerformed on all batches to demonstrate that pyrogen limit specifications through LAL test according to the United States Pharmacopeial Convention is always respected. (Implies the device is non-pyrogenic).
    Clinical Survival RateSurvival rates of the 3.9mm and 4.3mm implants which met the criteria for successful implant osseointegration, were 100% for both studies. (Implied acceptance based on comparison with existing clinical expectations for dental implants. High survival rates are a key indicator of clinical success).
    Clinical ComplicationsNo differences were registered among clinical indices related to the different abutments inclinations (modified Plaque Index (mPLI), modified Bleeding Index (mBI), Mucosal Seal Efficacy Evaluation (MSEE) and Zygomatic Implants Classification Level (ZICL)). (Implies that different abutment angles do not lead to increased complications).

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    • Sample Size (Clinical): 143 JDZygoma dental implants in a total of 66 patients.
    • Data Provenance: The studies were retrospective studies. The country of origin of the data is not specified in the provided text.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    The document does not provide details on the number or qualifications of experts used to establish ground truth for the clinical studies. It states that "Outcome measures were evaluated," but doesn't specify who performed these evaluations or their credentials.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    The document does not describe any specific adjudication method for the clinical study outcomes.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    This section is Not Applicable to the provided document. The JDZygoma dental implant is a physical medical device (dental implant and abutments), not an AI/software device that would involve human readers or AI assistance in interpretation.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    This section is Not Applicable for the same reasons as point 5.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    For the clinical studies, the ground truth was outcomes data including:

    • Implant/abutment success (defined by criteria for successful implant osseointegration)
    • Prosthetic survival
    • General postoperative complications
    • Secondary outcomes: Modified Plaque Index (mPLI), modified Bleeding Index (mBI), Mucosal Seal Efficacy Evaluation (MSEE), and Zygomatic Implants Classification Level (ZICL).

    8. The sample size for the training set

    The document refers to retrospective studies and does not mention a separate "training set" in the context of device development or validation. The "143 JDZygoma dental implants in a total of 66 patients" represent the clinical data used for validation, not a separate training set as would be typical for AI/machine learning.

    9. How the ground truth for the training set was established

    As there is no described "training set" in the context of AI/machine learning, this point is Not Applicable. The clinical "ground truth" (outcomes data) for the retrospective studies was established by evaluating the performance of the implants in patients post-surgically, as described in point 7.

    Ask a Question

    Ask a specific question about this device

    K Number
    K203725

    Validate with FDA (Live)

    Date Cleared
    2021-06-23

    (184 days)

    Product Code
    Regulation Number
    872.3640
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K160119, K173343

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    For Strong SW HE Implants

    S.I.N. Dental Implant System is intended for placement in the maxillary or mandibular arch to provide support for single-unit or multi-unit restorations. When a one-stage surgical approach is applied, the S.I.N. Dental Implant System is intended for immediate loading when good primary stability is achieved and with appropriate occlusal loading.

    S.I.N. Dental Implant System implants with lengths of 18, 20, 22, or 24 mm when placed in the maxilla are only indicated for multiple unit restorations in splinted applications that utilize at least two implants.

    For Zygomatic Implants and Abutments

    S.I.N. Dental Implant System Zygomatic implants are intended for placement in the maxillary arch to provide support for fixed or removable dental prostheses in patients with partially or fully edentulous maxillae. When a one-stage surgical approach is applied, the S.I.N. Dental Implant System Zygomatic implants are intended for immediate loading when good primary stability is achieved and with appropriate occlusal loading.

    Device Description

    The purpose of this submission is to add components to the S.I.N. Dental Implant System cleared in K170398, including a line of zygomatic dental implants and abutments.

    The subject device Strong SW HE dental implants are nearly identical to the Strong SW HE dental implants cleared in K170398, with a cylindrical design that tapers slightly to the apex, a body/endosseous thread diameter of 3.75 mm, and a platform diameter of 4.1 mm. This submission adds overall lengths of 18, 20, 22, and 24 mm. The endosseous threads have a uniform trapezoidal design and have an acidetched surface. The implants have an external hexagon ("HE") abutment interface connection, internal threads, and an internal hexolobular feature for instrument attachment.

    The subject device Zygomatic dental implants have a body diameter of 4.5 mm at the coronal end and a body diameter of 3.85 mm at the apical end with additional tapering to the apex. The abutment platform is 4.1 mm and is angled 45° to the long axis of the implant. The coronal end of the Zygomatic implants have a micro-channel surface feature starting at approximately the angled abutment platform extending over a length of approximately 2.9 mm; the micro-channel blends to a micro-thread and extends apically over a length of 2.15 mm. The micro-thread major diameter is 4.5 mm. All Zygomatic implants also are threaded over a length of 10.7 mm at the apical end with a major thread diameter of 3.85 mm. The endosseous threads at the apical aspect of the Zygomatic implants have the same uniform trapezoidal design and acid-etched surface as the Strong SW HE implants are provided in a range of lengths from 34 mm to 59 mm increments. The implant length is measured from the start of the micro-threads to the apex.

    This submission includes an implant cover for the subject Zygomatic implants, with a coronal diameter of 4.1 mm that matches the implant platform, and is threaded to match the internal thread of the Zygomatic implants. This submission also includes Mini Abutment Zygomatic Standard and Mini Abutment Zygomatic Conical; these abutments are straight, multi-unit, non-indexed abutments for the external hex connection of the Zygomatic implants. Mini Abutment Zygomatic Standard and Mini Abutment Zygomatic Conical are straight, multi-unit, non-indexed abutments for the external hex connection of the Zygomatic implants. Mini Abutment Zygomatic Standard are provided in one platform diameter (4.1 mm), one prosthetic platform diameter (4.5 mm), and in gingival heights of 3 mm, and 5.5 mm. Mini Abutment Zygomatic Conical are provided in one platform diameter (4.1 mm), one prosthetic platform diameter (4.8 mm), and in gingival heights of 2 mm, 3 mm, and 4 mm. Each abutment requires a corresponding subject device abutment screw to match the gingival height of the abutment. The Mini Abutment Standard and Mini Abutment Conical are the only abutments that are compatible with the subject device Zygomatic implants. For the Mini Abutment Zygomatic Standard, this submission also includes an Abutment Protector and a castable Co-Cr Base. For the Mini Abutment Zygomatic Conical, this submission also includes an Abutment Protector, Temporary Titanium Cylinder, and a castable Co-Cr Base. A Coping Screw is also included for use with all zygomatic abutments.

    AI/ML Overview

    The provided document is a 510(k) summary for a medical device (S.I.N. Dental Implant System), which focuses on demonstrating substantial equivalence to predicate devices rather than proving performance against specific acceptance criteria in a clinical study. Therefore, much of the requested information (e.g., sample size for test set, number of experts, adjudication method, MRMC study, training set size, ground truth for training set) is not typically included in such a submission.

    However, the document does contain information about performance data used to support the substantial equivalence claim.

    Here's a breakdown of the available information relevant to your request:

    1. Table of Acceptance Criteria and Reported Device Performance

    No explicit "acceptance criteria" are stated in terms of clinical performance metrics (e.g., sensitivity, specificity, accuracy) for a diagnostic AI device. Instead, the performance data provided relates to the safety and mechanical integrity of the dental implants. The device performance is demonstrated through conformance to relevant standards and established methods for dental implants.

    Performance CharacteristicAcceptance Criteria (Implicit from Standards/Methods)Reported Device Performance (as stated in the submission)
    SterilitySterility Assurance Level (SAL) of 10⁻⁶ (according to ISO 11137-1 and ISO 11137-2).Gamma irradiation sterilization for all subject devices (to a sterility assurance level of 10⁻⁶ by selecting and substantiating a 25 kGy dose using method VDmax25, according to ISO 11137-1 and ISO 11137-2, referenced from K170398). All subject device components are provided sterile by gamma irradiation, the same sterilization method used in K170398.
    Bacterial EndotoxinLimit of < 20 EU/device (according to ANSI/AAMI ST72).Bacterial endotoxin testing (referenced from K170398) including Limulus amebocyte lysate (LAL) test according to ANSI/AAMI ST72 on samples of water used in manufacturing on a weekly basis and on samples from sterilized product on a quarterly basis to demonstrate all sterile product meets a limit of < 20 EU/device.
    Shelf LifeMaintenance of packaging sterile barrier (according to ASTM F1929 and F88/F88M) and sterility for the stated shelf life.Shelf life testing (referenced from K170398) including testing of samples after 4 years of real time aging according to ASTM F1929 and F88/F88M (packaging sterile barrier) and sterility testing of product.
    BiocompatibilityBiocompatibility requirements for medical devices (implicitly referencing standards like ISO 10993).Biocompatibility data on subject device materials and manufacturing processes (including the acid-etching surface treatment for dental implants and anodization for abutment screws) leveraged from K170398. The materials (ASTM F67 and ASTM F136) are identical to those used in K170398. The acid etching process and anodization process are identical to those used in K170398.
    Mechanical StrengthSufficient strength for intended use (implicitly referencing ISO 14801 for dynamic fatigue testing and zygomatic implant placement protocols).Static compression and compression fatigue testing of worst-case constructs comprising the subject device Zygomatic implants and compatible subject device Mini Abutment Zygomatic Standard in conformance with ISO 14801 and the zygomatic implant placement protocol for nominal bone level. Based on results of dynamic testing in conformance with ISO 14801 and the zygomatic implant placement protocol for nominal bone level, the subject device zygomatic implants were shown to have sufficient strength for their intended use. Performance in accordance with the specified standard. Labeling mitigations for implant placement and matched surgical protocol for bone contact, as demonstrated by dynamic fatigue testing in conformance with ISO 14801.

    2. Sample Size Used for the Test Set and Data Provenance

    • Sample Size for Test Set: Not explicitly stated as a numerical sample size for a "test set" in the context of clinical performance. The "testing" refers to non-clinical tests (e.g., mechanical, sterilization).
      • For bacterial endotoxin testing: "samples of water used in manufacturing on a weekly basis and on samples from sterilized product on a quarterly basis."
      • For shelf life testing: "samples after 4 years of real time aging."
      • For mechanical strength: "worst-case constructs comprising the subject device Zygomatic implants and compatible subject device Mini Abutment Zygomatic Standard."
    • Data Provenance: The data is primarily non-clinical and internal to the manufacturer, leveraging past submissions (K170398) and conducted according to international standards (ISO, ASTM, ANSI/AAMI). No country of origin for the "test set" is applicable in the human data sense. It is all retrospective in the sense that previous testing for predicate devices and ongoing quality control testing is referenced.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications of Those Experts

    This information is not applicable to this submission, as no human-expert-validated "ground truth" test set (clinical data) was used. The performance data is based on non-clinical engineering and biological safety tests.

    4. Adjudication Method for the Test Set

    This information is not applicable since no human expert review or adjudication of a clinical test set was involved.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done, If So, What Was the Effect Size of How Much Human Readers Improve with AI vs Without AI Assistance

    This information is not applicable, as the device is a physical dental implant system, not an AI-assisted diagnostic or therapeutic device. No AI component is mentioned.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done

    This information is not applicable, as the device is a physical dental implant system and does not involve an algorithm with standalone performance.

    7. The Type of Ground Truth Used

    The "ground truth" in this context is established by engineering standards and biological safety standards. For example:

    • Sterility: Defined by a Sterility Assurance Level (SAL) of 10⁻⁶.
    • Bacterial Endotoxin: Defined by a quantifiable limit (< 20 EU/device) per standard.
    • Mechanical Strength: Defined by performance criteria within the ISO 14801 standard.
    • Biocompatibility: Defined by compliance with ISO 10993 standards (leveraged from predicate).

    8. The Sample Size for the Training Set

    This information is not applicable, as there is no mention of a "training set" for an algorithm. The device design and materials are based on established engineering principles and prior validated devices.

    9. How the Ground Truth for the Training Set Was Established

    This information is not applicable, as there is no "training set" and associated ground truth for an algorithm.