510(k) Data Aggregation

    K Number
    K252319

    Validate with FDA (Live)

    Date Cleared
    2025-10-20

    (87 days)

    Product Code
    Regulation Number
    878.4810
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K193609, K173038

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Q-Switched Nd: YAG Laser machine is indicated for use in tattoo removal, treatment of benign vascular lesions, treatment of benign pigmented lesions, incision, excision, ablation, vaporization of soft tissue for general dermatology as follows:

    1064nm:

    • Tattoo Removal
      Dark ink: blue and black.
    • Treatment of Benign Pigmented Lesions
      Nevus of ota.

    532nm:

    • Tattoo Removal
      Light ink: red, Light ink: sky blue and green.
    • Treatment of Benign Vascular Lesions
      Port wine birthmarks; Telangiectasias; Spider angioma; Cherry angioma; Spider nevi.
    • Treatment of Benign Pigmented Lesions
      Cafe-au-lait birthmarks; Solar lentiginos; Senile lentiginos; Becker's nevi; Freckles; Nevus spilus.
    Device Description

    The Q-Switched Nd: YAG Laser machine is a laser system which delivers light at a wavelength 1064nm or 532nm. The Q-Switched Nd: YAG Laser machine is indicated for use in tattoo removal, treatment of benign vascular lesions, treatment of benign pigmented lesions, incision, excision, ablation, vaporization of soft tissue for general dermatology. The device comprises a main unit, light guide arm and footswitch.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K193477

    Validate with FDA (Live)

    Date Cleared
    2020-06-24

    (191 days)

    Product Code
    Regulation Number
    878.4810
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K173038

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The device is indicated for the incision, ablation, vaporization of soft tissues for general dermatology, dermatologic and general surgical procedures for coagulation and hemostasis.
    532nm wavelength:
    -Tattoo removal: light ink(red, tan, purple, orange, skyblue, green)
    -Removal of Epidermal Benign Pigmented Lesions
    -Removal of Minor Benign Vascular Lesions including but not limited to telangiectasias
    -Treatment of Lentigines
    -Treatment of Cafe-Au-Lait
    -Treatment of Seborrheic Keratoses
    -Treatment of Post Inflammatory Hyper-Pigmentation
    -Treatment of Becker's Nevi, Freckles and Nevi Spilus
    1064nm Wavelength:
    -Tattoo removal: dark ink (black, blue and brown)
    -Removal of Nevus of Ota
    -Removal or lightening of unwanted hair with or without adjuvant preparation.
    -Treatment of Common Nevi
    -Skin resurfacing procedures for the treatment of acne scars and wrinkle

    Device Description

    The proposed device is a multi-wavelength, pulsed laser system designed for the treatment of benign pigmented lesions. The device can produce 1064nm and 532nm two different laser wavelengths to treat the different color skin. It consists of power supply module, microprocessor control module, laser treatment handpiece module, operation display module and cooling system module. The physician is able to select the desired wavelength and the related output energy via control panel.

    AI/ML Overview

    The provided text is a 510(k) Summary for a medical device (Nd:YAG Laser Therapy Systems). It states explicitly in section 11 "Clinical Testing" that "No clinical study is included in this submission."

    Therefore, I cannot provide information on acceptance criteria and the study that proves the device meets those criteria, a table of acceptance criteria and reported device performance, sample sizes, number of experts, adjudication methods, MRMC studies, standalone performance, or ground truth details, as no clinical studies were conducted or provided in this submission.

    The document focuses on demonstrating substantial equivalence to a predicate device (CuRAS Nd: YAG Laser, K173038) based on non-clinical testing, including electrical safety, EMC, biocompatibility, and software validation. It compares device specifications and indications for use, showing they are identical or very similar to the predicate.