    Intended Use

    The Miracu™ Absorbable Polydioxanone Suture with Needle (MONO) is comprised of dyed polydioxanone, is indicated for soft tissue approximation where use of an absorbable suture is appropriate. The anatomical location( s) of use are on the skin for dermatological applications only. The suture is not intended for interior body cavity applications and the suture is not intended for lifting and supporting tissues.

    Device Description

    Miracu™ synthetic absorbable PDO suture with needle is made of polydioxanone. The pigment for the violet dye is D&C Violet No.2. The Miracu™ is available sterile after ethylene oxide (EO) gas sterilization and degrades or dissolves over time in tissue.

    Each dyed (violet) suture has no barbs along the long axis of the suture monofilament with needle attachment. The Miracu™ Synthetic Absorbable PDO suture with needle (No Barb) approximates tissue is equivalent in form and function to the predicate device DemeDIOX (K181582).

    The proposed suture is available in 4-0, 5-0, 6-0 suture sizes, which are the sizes identified in the currently recognized United States Pharmacopeia, and is equivalent to sizes available in the PDREX reference device (K173779).

    The formation of barbs in the Miracu™ reduces the tensile strength relative to non-barbed suture material of the same size. Therefore, the suture tensile strength for the Non Barbed is not compromised and is equal or stronger than the barbed reference configuration. The Miracu™ non-barbed suture is made from the same material, sterilized in the same manner, and packaged as the barbed reference device Miracu™ (K172602).

    The strength of the Miracu™ (non Barbed) can be compared with, and is substantially equivalent to, the publicly available information for the PDS Plus (K212380).

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K220549

    Validate with FDA (Live)

    Date Cleared
    2023-03-07

    (375 days)

    Product Code
    Regulation Number
    878.4840
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K172602, K190245, K082097, K130191, K163676

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    MINT Product Family (Including MINT Lift, and MINT-I Sutures) are comprised of PDO and are indicated for use in soft tissue approximation where use of a barbed absorbable suture is appropriate.

    These sutures are also indicated for use in face suspension surgery to temporarily fixate the cheek sub dermis in an elevated position.

    Device Description

    MINT Product Family Sutures are synthetic, absorbable, sterile, surgical sutures comprised of polydioxanone. These sutures are available in a range of lengths and thicknesses and have bi-directional barbs which hold the suture in position and exert tension throughout the length of the suture. These sutures are provided sterile. They degrade and reabsorb over time.

    AI/ML Overview

    The provided text is a 510(k) summary for the MINT Product Family of absorbable polydioxanone surgical sutures. It describes the device, its intended use, and argues for substantial equivalence to a predicate device. However, it does not contain the type of AI/ML device performance data, acceptance criteria, or study details (sample sizes, expert consensus, MRMC studies, etc.) that would typically be found for an AI/ML powered medical device.

    The document is for surgical sutures, a physical medical device, not an AI/ML software device. Therefore, the requested information about acceptance criteria for an AI/ML device, details of diagnostic performance studies, expert involvement in ground truth, etc., are not present in this document.

    The document discusses "non-clinical performance data" and "clinical performance data" related to the physical sutures, but these are for the material properties and safety/effectiveness of the suture itself, not for an AI/ML algorithm's diagnostic performance.

    Therefore, I cannot provide the requested information because the provided text is about a physical surgical suture device, not an AI/ML software device.

    The document does not describe:

    • Acceptance criteria related to AI/ML performance (e.g., sensitivity, specificity, AUC)
    • A test set size for an AI/ML model
    • Data provenance for AI/ML training/testing
    • Number/qualifications of experts for AI/ML ground truth
    • Adjudication methods for AI/ML ground truth
    • MRMC studies for AI/ML assistance
    • Standalone AI algorithm performance
    • Type of ground truth for an AI/ML model
    • Training set size for an AI/ML model
    • How ground truth for a training set was established for an AI/ML model.

    What the document does discuss (related to the physical suture device):

    • Non-Clinical Performance Data: Bench testing confirming compliance with USP standards for tensile strength, barb holding strength, suture-needle attachment strength, needle corrosion resistance, needle flexural stress, cannula pull testing, and needle penetration testing. Biocompatibility testing per ISO 10993.
    • Clinical Performance Data: A review of published clinical literature (10 relevant articles) from regions where the product is available. This literature involved over 500 patients with a minimum of 3 months follow-up (some 22+ months) supporting the safety and effectiveness of the sutures for face suspension surgery. The literature addressed complications associated with the sutures and procedure, not an AI algorithm.