    K Number
    K171008

    Validate with FDA (Live)

    Date Cleared
    2017-10-30

    (209 days)

    Product Code
    Regulation Number
    872.3930
    Panel
    Dental
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K162158, K120601

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Anorganic Bone Mineral with Collagen in Delivery Applicator is intended for use in dental surgery. The products may be used in surgical procedures such as:

    • Augmentation or reconstructive treatment of alveolar ridge
    • Filling of infrabony periodontal defects
    • Filling of defects after root resection, apicoectomy, and cystectomy
    • Filling of extraction sockets to enhance preservation of the alveolar ridge
    • Elevation of maxillary sinus floor
    • Filling of periodontal defects in conjuncts intended for Guided Tissue Regeneration (GTR) and Guided Bone Regeneration (GBR)
    • Filling of peri-implant defects in conjunction with products intended for Guided Bone Regeneration.
    Device Description

    Anorganic Bone Mineral with Collagen in Delivery Applicator are porous bone mineral matrices consisting of calcium phosphate derived from bovine bone with the addition of bovine type I collagen, pre-loaded into a delivery applicator for ease of placement in the defect site. The anorganic bone mineral component is produced by removal of the organic components from bovine bone. The type I collagen component is derived from bovine Achilles tendon. Anorganic Bone Mineral with Collagen in Delivery Applicator is sterilized by gamma irradiation. The products are non-pyrogenic and for single use only.

    AI/ML Overview

    The provided document is a 510(k) summary for the "Anorganic Bone Mineral with Collagen in Delivery Applicator" device. It describes the device, its indications for use, and a comparison with predicate devices to establish substantial equivalence. However, it does not contain information typically found in a study proving a device meets specific acceptance criteria for performance metrics like sensitivity, specificity, accuracy, or reader effectiveness for an AI/ML medical device.

    This document describes a bone grafting material and its delivery applicator, a Class II medical device. The focus is on demonstrating substantial equivalence to existing predicate devices through material properties, biocompatibility, sterilization, and functionality. It is not an AI/ML device, and therefore the concepts of "acceptance criteria" in the context of statistical performance metrics, "test set," "training set," "ground truth," "expert adjudication," or "MRMC studies" as they apply to AI/ML devices are not relevant here.

    Therefore, I cannot provide the requested information for an AI/ML device.

    Here's what I can extract based on the document's content, focusing on non-clinical performance testing:

    While not in the format of AI/ML acceptance criteria, the document describes "Non-Clinical Performance Testing" which serves a similar purpose of verifying device performance.

    1. A table of acceptance criteria and the reported device performance:

    Since this is not an AI/ML device evaluation, the "acceptance criteria" are related to physical, chemical, and biological properties, not statistical performance metrics.

    FeatureAcceptance Criteria (Implied / Stated)Reported Device Performance
    BiocompatibilityNon-cytotoxic, non-irritating, non-sensitizing, non-pyrogenic, non-toxicSterile Finished Device: Cytotoxicity, irritation, and sensitization confirmed acceptable. Delivery Applicator: Cytotoxicity, physicochemical attributes of a polymeric material, containers - plastics, physicochemical tests USP <661>, physicochemical (material/chemical) characterization testing of non-aged and 36 month real time aged delivery applicators with extraction conditions and methods in accordance with ISO 10993-12 and ISO 10993-18. Anorganic Bone Mineral & Purified Type I Collagen: Cytotoxicity, sensitization, acute systemic toxicity, genotoxicity, pyrogenicity, implantation, subacute/subchronic toxicity confirmed acceptable (previously submitted).
    SterilitySterility Assurance Level (SAL) 10⁻⁶Gamma irradiation, SAL 10⁻⁶ (validated in accordance with ISO 11137-1)
    PyrogenicityNon-pyrogenicNon-pyrogenic (confirmed by testing)
    Single UseSingle use onlySingle Use Only (as designed)
    Plunger ForceSpecific force range for dispensing (for the delivery applicator)4.5 N ± 1.3 N (preformed plug)4.1 N ± 1.1 N (moldable plug)
    FunctionalitySuccessful delivery of material, ease of placementBench testing of delivery applicator functionality and customer assessment (results not detailed, but implied as successful for substantial equivalence).
    Animal PerformanceAcceptable integration/performance in bone regeneration modelsPorcine Anorganic Bone Mineral: Intraoral defect in a canine model. Anorganic Bone Mineral with and without Collagen: Rabbit femoral condyle defect model. Purified Type I Collagen: Rat subcutaneous implantation study. (Results are implied to be acceptable for substantial equivalence, but specific metrics are not provided).

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    This information is not applicable in the context of an AI/ML "test set" and statistical performance. For the non-clinical testing:

    • Sample sizes for biocompatibility, sterility, and pyrogenicity: Not specified in the document, but understood to adhere to relevant ISO standards (e.g., ISO 10993, ISO 11137).
    • Sample size for plunger force: Not specified for how many units were tested.
    • Sample sizes for animal studies: "a canine model," "a rabbit femoral condyle defect model," "a rat subcutaneous implantation study." Specific numbers of animals are not provided.
    • Data provenance: Not explicitly stated, but assumed to be from internal lab studies and potentially contract research organizations. No country of origin for test data is mentioned. The studies are prospective in the sense that they were conducted for the purpose of this submission.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    Not applicable. "Ground truth" in the context of an AI/ML device (e.g., disease presence/absence) is not relevant here. The "ground truth" for this device's performance is established by the direct physical, chemical, and biological testing results against predefined specifications and regulatory standards.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    Not applicable. This is not an AI/ML device requiring human adjudication of performance outputs.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This is not an AI/ML device.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Not applicable. This is not an AI/ML device.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    As explained, "ground truth" for AI/ML devices is not applicable. For this device, the "truth" is established by:

    • Direct analytical measurements (e.g., plunger force, material composition, physicochemical tests).
    • Standardized biological assays (e.g., cytotoxicity, sensitization, pyrogenicity tests).
    • Histopathological and physiological observations from animal models of bone regeneration.

    8. The sample size for the training set

    Not applicable. This is not an AI/ML device, so there is no "training set."

    9. How the ground truth for the training set was established

    Not applicable. There is no training set for this type of device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K170541

    Validate with FDA (Live)

    Date Cleared
    2017-07-07

    (134 days)

    Product Code
    Regulation Number
    872.3930
    Panel
    Dental
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K162158, K120601

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Anorganic Bone Mineral in Delivery Applicator is intended for use in dental surgery. The products may be used in surgical procedures such as:

    • Augmentation or reconstructive treatment of alveolar ridge
    • Filling of infrabony periodontal defects
    • Filling of defects after root resection, apicoectomy, and cystectomy
    • Filling of extraction sockets to enhance preservation of the alveolar ridge
    • Elevation of maxillary sinus floor
    • Filling of periodontal defects in conjuncts intended for Guided Tissue Regeneration (GTR) and Guided Bone Regeneration (GBR)
    • Filling of peri-implant defects in conjunction with products intended for Guided Bone Regeneration.
    Device Description

    Anorganic Bone Mineral in Delivery Applicator are porous bone mineral matrices consisting of calcium phosphate derived from bovine bone without the addition of bovine type I collagen, preloaded into a delivery applicator for ease of placement in the defect site. The anorganic bone mineral component is produced by removal of the organic components from bovine bone. Anorganic Bone Mineral in Delivery Applicator is sterilized by gamma irradiation. The products are non-pyrogenic and for single use only.

    AI/ML Overview

    The document describes a 510(k) premarket notification for a medical device called "Anorganic Bone Mineral in Delivery Applicator". It does not describe a study involving an algorithm or AI.

    Therefore, many of the requested categories (sample size for test set, data provenance, number of experts, adjudication method, MRMC study, standalone performance, ground truth type for test set, training set sample size, ground truth for training set) are not applicable to this document.

    However, I can provide the acceptance criteria and demonstrated performance based on the non-clinical testing described.

    1. Table of acceptance criteria and the reported device performance

    FeatureAcceptance Criteria / StandardReported Device Performance
    Material/SourceBovine Bone, Anorganic Bone MineralBovine Bone (anorganic bone mineral)
    Composition100% Anorganic Bone Mineral Granules100% Anorganic Bone Mineral Granules
    Particle Size0.25 - 1.0 mm0.25 - 1.0 mm
    BiocompatibilityBiocompatible (based on ISO standards)Biocompatible (demonstrated by testing)
    SterilityGamma irradiation, SAL 10^-6Gamma irradiation, SAL 10^-6 (validated based on ISO 11137-1)
    PyrogenicityNon-pyrogenicNon-pyrogenic
    Single UseSingle Use OnlySingle Use Only
    Plunger ForceNot explicitly defined as "acceptance criteria", but a performance measure for the delivery applicator8.18 ± 3.8 N (measured for the subject device)

    Additional Non-Clinical Performance Testing:

    • Biocompatibility of Sterile Finished Device: Cytotoxicity, irritation, and sensitization tests were performed and demonstrated biocompatibility. (Specific acceptance criteria for these individual tests are not detailed, but the conclusion states they were met.)
    • Biocompatibility of Delivery Applicator: Cytotoxicity, physicochemical attributes of a polymeric material, and USP <661> physicochemical tests were performed. (Specific acceptance criteria not detailed, but the conclusion states they were met.)
    • Biocompatibility of Anorganic Bone Mineral: Cytotoxicity, sensitization, irritation, acute systemic toxicity, genotoxicity, pyrogenicity, implantation, and subacute/subchronic toxicity tests were performed. (Previously submitted and deemed applicable, conclusion states they were met.)
    • Sterilization Validation: Performed in accordance with ISO 11137-1. (Implies meeting the SAL 10^-6 requirement.)
    • Bench Testing of Delivery Applicator Functionality and Customer Assessment: Performed. (Implies proper functioning of the applicator.)
    • Animal Performance Testing:
      • Anorganic Bone Mineral (derived from porcine bone tissue): Tested in an intraoral defect in a canine model.
      • Anorganic Bone Mineral with and without Collagen: Tested in a rabbit femoral condyle defect model.
        (These studies supported the performance of the bone mineral component, which is part of the subject device.)

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    Not applicable, as this document describes non-clinical performance testing for a medical device (bone graft material and applicator), not an AI/algorithm study. The relevant "tests" involved laboratory-based biocompatibility, sterilization validation, and bench testing, as well as animal studies. The sample sizes for these specific non-clinical tests (e.g., number of animals, number of test samples for material characterization) are not detailed in this summary.


    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    Not applicable, as this document describes non-clinical performance testing for a medical device (bone graft material and applicator), not an AI/algorithm study requiring expert-established ground truth.


    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    Not applicable.


    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable.


    6. If a standalone (i.e. algorithm only without human-in-the loop performance) was done

    Not applicable.


    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    Not applicable, as this document describes non-clinical performance testing not requiring a clinical "ground truth" as typically defined for diagnostic AI. The "ground truth" for these tests would be the established scientific standards and methods for assessing material properties, biocompatibility, and sterility.


    8. The sample size for the training set

    Not applicable.


    9. How the ground truth for the training set was established

    Not applicable.