510(k) Data Aggregation

    K Number
    K231276

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2023-08-30

    (120 days)

    Product Code
    Regulation Number
    870.1025
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K160064

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The SmartCardia 7L Platform is a prescribed device used for the purpose of identifying non-lethal arrhythmias. The SmartCardia 7L Platform is intended for:

    1. Patients who experience transient symptoms that may suggest cardiac arrhythmia.
    2. Patients who require monitoring of effect of drugs to control ventricular rate in various atrial arrhythmias (e.g., atrial fibrillation).
    3. Patients with symptoms that may be due to cardiac arrhythmias. These may include but are not limited to symptoms such as: a) dizziness or lightheadedness; b) syncope of unknown etiology in which arrhythmias are suspected or need to be excluded; and c) dyspnea (shortness of breath).
    4. Patients recovering from cardiac surgery or interventional procedures who are indicated for outpatient arrhythmia monitoring.
    5. ECG data recorded by the device can be analyzed by other processing systems to provide Holter style reports. Measurements include: electrocardiogram (ECG signal), R-R interval, Heart Rate. Notification alerts can be set for one or more of these measures.
      The SmartCardia 7L Platform is indicated for use on patients who are 18 years of age or older to provide monitoring of physiological information. It is intended for use in a physician office, outpatient facility, or in the patient's home.
      SmartCardia 7L Platform contraindications:
    6. The SmartCardia 7L Platform is contraindicated for use in a critical care setting where an immediate response to life threatening conditions such as lethal arrhythmias is required.
    7. The SmartCardia 7L Platform is contraindicated for use during external defibrillation.
    Device Description

    The SmartCardia 7L Platform is a body worn Holter monitoring product that is designed with a disposable adhesive 7L Patch and reusable 7L Sensor. It is designed to be worn by the patient for up to 14 days. If longer monitoring is necessary, the 7L Patch is removed from the body, the 7L Sensor is removed from the worn 7L Patch which is discarded. The 7L Sensor is inserted into a new 7L Patch and the new assembly is placed on the patient for monitoring to continue.
    The 7L Sensor/7L Patch assembly communicates to the SmartCardia Phone via Bluetooth technology and shows the patient's heart rate and ECG on its display and allows the patient to input symptoms (Mark Event) which are shown in the patient record. The SmartCardia Phone has a medical grade mains powered charger and uses its cellular technology to act as a gateway to the SmartCardia Cloud Service provided by Amazon Web Services. The SmartCardia Phone is pre-configured by SmartCardia and placed in a kiosk mode. Data stored in the SmartCardia cloud can be viewed in the SmartCardia Web Browser application by a clinician or healthcare provider. The SmartCardia 7L Platform incorporates two modes of Holter monitoring:

    1. Holter Monitoring (up to 48 hours) and Extended Holter Monitoring (>48 hours and up to 14 days),
    2. Event Monitoring (up to 48 hours, and >48 hours up to 14 days)
      During any of the selected modes of Holter monitoring, a clinician or healthcare provider can use the SmartCardia Web Browser and continuously monitor the patient.
      The SmartCardia 7L Platform provides alarm notifications for heart rate and atrial fibrillation. As stated in the Intended Use statement, the system is contraindicated for use in a critical care setting where an immediate response to life threatening conditions such as lethal arrhythmias is required. There are no alarm signals presented to the clinician for conditions other than heart rate and atrial fibrillation.
      The SmartCardia 7L Platform, like most Holter monitoring systems performs retrospective analysis and identifies events which it shows the clinician when they are reviewing historical data. The clinician must then review these events and determine if they are indeed valid and should be included in a physician's report. These events are things like 'Ventricular Bigeminy', 'Supraventricular Couplet', etc. A full list is included in the Clinician Instructions for Use.
    AI/ML Overview

    This document describes the device's technical characteristics and bench testing summary but does not provide complete details on a clinical study that proves the device meets the acceptance criteria, particularly for AI/algorithm performance. The information provided is primarily focused on hardware and basic signal acquisition validation against regulatory standards.

    Here's an attempt to answer your questions based on the provided text, with explicit notes where information is missing or unclear for a comprehensive AI/algorithm study:

    1. Table of Acceptance Criteria and Reported Device Performance

    The document mentions "Pass criteria is compliance with the claimed range and precision provided in the labeling for the SmartCardia 7L Platform" and that the device "met the pass/fail criteria established by the appropriate standards." However, it does not explicitly list specific numerical acceptance criteria or performance metrics for arrhythmia detection beyond stating that "the SmartCardia 7L Platform algorithm detection and reported results for the stated output arrhythmia were satisfactory and met industry norms."

    Acceptance CriteriaReported Device Performance
    Compliance with claimed ranges and precision provided in labeling for heart rate, R-R interval, and ECG signal performance (no specific values given).Device met these pass/fail criteria.
    ECG detection algorithm performance for "stated output arrhythmia" meeting "industry norms" per ANSI/AAMI EC57 (excluding ST-segment analysis).Algorithm detection and reported results were satisfactory and met industry norms.
    Wireless Coexistence testing per FDA Guidance and ANSI C63.27: 2017.Testing showed compliance.
    Basic Safety and Essential Performance per IEC 60601-1.Testing showed compliance.
    Electromagnetic Compatibility per IEC 60601-2.Testing showed compliance.
    Life Cycle testing per IEC 60601-11 Home Healthcare.Testing showed compliance.
    ECG electrode testing per ANSI/AAMI EC12.Testing showed compliance.
    Cleaning and disinfection methods as defined by SmartCardia SA.N/A (protocol defined, performance not explicitly stated).
    ECG Waveform Quality and Wearability.Verification testing performed, included in DVR-67-01 report. Results stated as satisfactory regarding morphology and ECG characteristics.
    Effects of Sensor Positioning on ECG Performance.N/A (protocol defined, performance not explicitly stated).
    Defibrillator protection.Testing performed to ensure no excessive energy shunted. Device contraindicated during defibrillation and labeled accordingly.

    2. Sample Size Used for the Test Set and Data Provenance

    The document states, "SmartCardia developed a protocol and database for evaluating the analysis algorithm" for the EC57 testing. However, it does not specify the sample size of this database (test set). It also does not mention the country of origin of the data or whether it was retrospective or prospective.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts

    This information is not provided in the document. For an algorithm evaluation, expert review is crucial for establishing ground truth, but no details are given.

    4. Adjudication Method for the Test Set

    This information is not provided in the document.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    The document does not indicate that a MRMC comparative effectiveness study was done. The testing described is primarily focused on the device's technical performance and algorithm's standalone detection capabilities, not the improvement in human reader performance with AI assistance.

    6. Standalone Performance (Algorithm Only without Human-in-the-Loop Performance)

    Yes, a standalone performance evaluation of the algorithm was conducted. The document states: "The ECG detection algorithm was tested per ANSI/AAMI EC57 standard for testing and reporting performance results of cardiac rhythm... SmartCardia developed a protocol and database for evaluating the analysis algorithm. The results show that the SmartCardia 7L Platform algorithm detection and reported results for the stated output arrhythmia were satisfactory and met industry norms."

    7. Type of Ground Truth Used

    The document mentions "SmartCardia developed a protocol and database for evaluating the analysis algorithm" per the ANSI/AAMI EC57 standard. This standard provides guidelines for performance reporting of cardiac rhythm algorithms, which typically implies comparison against known, validated arrhythmia events within the ECG recordings. The source of this ground truth (e.g., expert consensus, independent adjudication, or a pre-validated dataset) is not explicitly stated, but for EC57, it's generally based on highly accurate reference annotations.

    8. Sample Size for the Training Set

    The document does not mention any details about a training set or its sample size. The focus of this submission is on the testing and validation of the device, not its development or algorithm training.

    9. How the Ground Truth for the Training Set Was Established

    Since no training set details are provided, information on how its ground truth was established is not available in this document.

    Ask a Question

    Ask a specific question about this device

    K Number
    K231620

    Validate with FDA (Live)

    Device Name
    Nuubo Smart
    Date Cleared
    2023-08-01

    (60 days)

    Product Code
    Regulation Number
    870.1425
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K121197, Stealth System S300 K162503, MoMe Kardia Wireless Ambulatory ECG Monitoring And Detection System K160064

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Nuubo Smart is indicated for use on patients who may be asymptomatic or who may suffer from transient symptoms such as palpitations, shortness of breath, dizziness, light-headedness, pre-syncope, fatigue, or anxiety. The Nuubo Smart continuously records and stores ECG and activity data for up to 30 days at a time. The Nuubo Smart detects arrhythmias at the end of each monitoring day upon download of the ECG data. The Nuubo Smart is Rx use device.

    Device Description

    Nuubo Smart is composed of the following main components:
    Nuubo30 (wearable) - The Nuubo30 is the wearable box that contains one Nuubo30 textile unit, ECG conductive cream, patient instructions and washing bag. Each textile can be used for 30 days.
    NuuboREC (recorder). The Nuubo recorder is a small, lightweight device that records ECG continuously. The device records 2 Leads of ECG data up to 30 days. The device also records data from a 3-axis accelerometer located inside the device. The patient can activate the button while wearing the product to mark a symptom. To start and stop the recording the user will press the on/off button. The data is stored into a micro SD memory card.
    Nuubo Dock - The Nuubo Dock is the element for downloading the data from the NuuboREC and uploads that data to the Nuubo Cloud. It consists of a plastic stand with a smartphone attached to it and a microUSB port where the NuuboREC is connected for recharge and data download. The smartphone is a single-purpose device that is intended to be always connected to the dock. The dock is intended to be connected to an outlet in the patient's home with the charger provided. The dock allows to charge the NuuboREC device, and during this charging, it downloads the data from the NuuboREC device into the smartphone. The smartphone is software restricted and can only run the Nuubo Dock App that transmits and receives data from the Nuubo Cloud.
    Leonardo Smart - Is used for downloading, analysis, visualization and report of the ECG-data stored by the recorder device and for managing the recorder device. The new version Leonardo Smart allows a clinical professional previously authenticated in the platform, to download and review signals recorded by the NuuboREC device which have been uploaded using Nuubo Dock.

    AI/ML Overview

    Here's a breakdown of the acceptance criteria and study information for the Nuubo Smart device, based on the provided text:

    1. Acceptance Criteria and Reported Device Performance

    The document primarily focuses on demonstrating substantial equivalence to predicate devices and compliance with harmonized standards. Direct, quantifiable acceptance criteria for arrhythmia detection performance are not explicitly stated for the new Nuubo Smart device in a separate table, but the performance of its underlying algorithm (inherited from Nuubo System K173461) is provided:

    Acceptance Criteria CategorySpecific Criteria (from referenced standards/previous device)Reported Device Performance (Nuubo Smart, or its inherited algorithm)
    Arrhythmia Detection (QRS)QRS Sensitivity and QRS Positive Predictivity per IEC60601-2-47.Over 99% QRS Sensitivity and QRS Positive Predictivity against the MIT-BIH database. Over 97% QRS Sensitivity and QRS Positive Predictivity against the AHA database.
    SoftwareMet all requirements (Unit Testing, System Verification and Validation Testing).Passed all Unit Testing and System Verification and Validation Testing.
    BiocompatibilityCompliance with ISO10993 standards (cytotoxicity, irritation, sensitization, material characterization per ISO 10993-18), as demonstrated for Nuubo System (K173461).The Nuubo Smart uses the same textile belt technology as Nuubo System (K173461), which was previously shown to comply with these standards.
    EMI/EMC/Electrical SafetyCompliance with IEC60601 requirements.Successfully completed the EMI/EMC/Electrical safety test requirements per IEC60601.
    Bench Studies (Wearable/Recorder)Met all requirements (design input), including battery performance for up to 30 days of use.Verification and validation testing for wearable and recorder confirmed it met all requirements, including battery performance for the proposed up to 30 days of use.
    Shipping and PackagingSuccessful completion of Transport Simulation tests (ASTM D 7386 TS-4, ASTM D 4169 DC 13) and visual inspection (ASTM F 1886/F 1886M).The Transport Simulation test according to ASTM D 7386 TS-4 of Nuubo Smart box, the Transport Simulation test according to ASTM D 4169 DC 13 of 4 Nuubo Smart units and subsequent visual inspection (ASTM F 1886/F 1886M) were successfully completed.
    UsabilitySummative usability testing demonstrating patients and caregivers did not encounter difficulties associated with a risk for potential of serious harm (critical tasks).Summative usability testing was completed demonstrating that patients and caregivers did not encounter any difficulties associated with a risk for potential of serious harm (critical tasks).

    2. Sample Size Used for the Test Set and Data Provenance

    The document mentions that the Nuubo Leonardo Arrhythmia detection algorithm (same as Nuubo System K173461) was tested against standard databases:

    • MIT-BIH database: A widely recognized standard for arrhythmia analysis.
    • AHA database: Another standard for arrhythmia analysis.

    The exact sample sizes (number of recordings or patients) from these databases used for testing are not explicitly stated in this document. These databases are generally retrospective collections of ECG data. The country of origin of the data is not specified for these public databases, but they are international benchmarks.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts

    The document does not provide information on the number of experts or their qualifications used to establish the ground truth for the MIT-BIH and AHA databases. These databases typically have expert-annotated ground truth established by cardiologists or electrophysiologists as part of their creation.

    4. Adjudication Method for the Test Set

    The document does not specify the adjudication method (e.g., 2+1, 3+1) used for the ground truth in the MIT-BIH and AHA databases. This information is usually part of the detailed documentation for those databases.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    A multi-reader multi-case (MRMC) comparative effectiveness study comparing human readers with AI assistance vs. without AI assistance was not mentioned or described in the provided text. The evaluation focused on the standalone performance of the algorithm against standard ECG databases.

    6. Standalone (Algorithm Only) Performance

    Yes, a standalone (algorithm only without human-in-the-loop performance) evaluation was done for the arrhythmia detection algorithm. As stated: "The Nuubo Leonardo Arrhythmia detection algorithm (same as Nuubo System K173461) was tested per requirements of IEC60601-2-47, and showed a QRS Sensitivity and QRS Positive predictivity of over 99% against the MIT-BIH database, and over 97% against the AHA database."

    7. Type of Ground Truth Used

    The ground truth used for the standalone algorithm testing was based on expert-annotated arrhythmias within the MIT-BIH and AHA databases. These are widely used standard databases with established annotations.

    8. Sample Size for the Training Set

    The document does not provide information on the sample size used for the training set of the Nuubo Leonardo Arrhythmia detection algorithm.

    9. How the Ground Truth for the Training Set Was Established

    The document does not provide information on how the ground truth for the training set was established. It only discusses the testing of the algorithm against public databases.