    Intended Use

    Cryotop®US-flash and Cryotop®US-scoop are cryopreservation storage devices that are intended for use in vitrification procedures to contain and maintain human oocytes (MII) and embryos.

    Device Description

    This 510(k) covers two subject devices, the Cryotop®US-flash and Cryotop®US-scoop that are modified versions of the predicate device (Cryotop®US, K153027). Both devices are cryopreservation storage devices intended for embryo/oocyte vitrification. Cryotop®US-flash and Cryotop®US-scoop are provided sterile and are for single-use only.

    The Cryotop®US-flash is composed of a polypropylene straw and an acrylonitrile butadiene styrene handle with a polyethylene terephthalate fine tip where oocytes or embryos are loaded. The fine device is flat with a triangular-shaped area for oocyte/embryo loading. The Cryotop®US-scoop is composed of a polypropylene straw and a polystyrene handle and fine tip where oocytes or embryos are loaded. The fine tip of this device is U-shaped. After oocyte or embryo loading, the handle of the subject devices is inserted into the straw enclosure. A hermetic seal is created via a tapered handle with a stop location integrated into the handle. As the handle is placed into the straw enclosure it creates a closed system keeping the fine tip isolated from the liquid nitrogen. The straw component of both devices also includes a weight at its distal end to aid in maintaining correct device position during storage in liquid nitrogen.

    AI/ML Overview

    The provided text describes a 510(k) premarket notification for two new cryopreservation storage devices: Cryotop®US-flash and Cryotop®US-scoop. The submission aims to demonstrate substantial equivalence to a predicate device, Cryotop®US (K153027). The document focuses on non-clinical performance data to support this claim, rather than a clinical study comparing the devices.

    Here's an analysis of the acceptance criteria and the study that proves the device meets them, based only on the provided text:

    1. Table of Acceptance Criteria and Reported Device Performance:

    Test CategorySpecific Test / CriterionAcceptance CriteriaReported Device Performance (Cryotop®US-flash & Cryotop®US-scoop)
    PerformanceCooling Rate3,000°C/minPassed: 3,000°C/min
    Warming Rate44,000°C/minPassed: 44,000°C/min
    Physical/MechanicalDimensional TestingOuter diameter and length per specifications (specific values not provided in this extract)Passed (implied)
    Durability TestingNo burst or liquid nitrogen ingress into straw after 30-second immersionPassed
    Mechanical Tensile TestingTensile strength to withstand 5NPassed
    BiocompatibilityBacterial Endotoxins<0.5 EU/device per USP <85> and ANSI/AAMI ST72:2002/(R)2010Passed: <0.5 EU/device
    Mouse Embryo Assay (MEA)≥80% of 1-cell embryos developed to blastocysts at 96 hoursPassed: ≥80%
    EnvironmentalTransportation Simulation TestingPer ASTM D4169-09Passed (implied)
    Shelf-LifePackage Integrity Testing: Dye penetrationPer ASTM F1929-15Passed (implied)
    Package Integrity Testing: Seal strengthPer ASTM F88/F88M-15Passed (implied)
    Shelf-Life (Dimensional, Mechanical, Durability, Endotoxin, MEA)In accordance with methods & acceptance criteria mentioned above for each testPassed (implied)

    2. Sample size used for the test set and the data provenance:

    • Sample Size: Not explicitly stated for each individual test. The document mentions "non-clinical performance testing" was conducted, implying multiple tests on multiple units, but no specific numbers of devices tested are provided.
    • Data Provenance: The tests were conducted by the manufacturer, Kitazato Corporation, as "internal requirements." The text does not specify the country of origin of the data beyond "Kitazato Corporation 81 Nakajima, Fuji-city Shizuoka 416-0907 JAPAN." These are retrospective tests performed for the 510(k) submission.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

    • This information is not provided as the tests are non-clinical, laboratory-based performance tests, not clinical studies requiring expert interpretation of outcomes.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set:

    • This information is not applicable as the tests are non-clinical and do not involve human interpretation or adjudication in the context of clinical outcomes. The results are objective measurements against defined criteria.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    • No MRMC comparative effectiveness study was done. This is a 510(k) submission for a medical device (cryopreservation storage device), not an AI-powered diagnostic tool, and therefore, an MRMC study is not applicable.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

    • This is not applicable as the submission is for a medical device (cryopreservation storage device), not an algorithm or AI.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

    • For the non-clinical performance tests, the "ground truth" is established by objective physical, chemical, and biological measurements against pre-defined, quantitative standards and specifications (e.g., specific temperatures, mechanical forces, endotoxin levels, embryo development rates).

    8. The sample size for the training set:

    • This concept is not applicable to this submission, as it's for physical medical devices and the non-clinical tests described do not involve machine learning or a training set.

    9. How the ground truth for the training set was established:

    • This question is not applicable as there is no training set for the described non-clinical performance tests for this medical device.
    Ask a Question

    Ask a specific question about this device

    K Number
    K171748

    Validate with FDA (Live)

    Date Cleared
    2017-12-14

    (184 days)

    Product Code
    Regulation Number
    884.6180
    Age Range
    All
    Reference & Predicate Devices
    Why did this record match?
    Reference Devices :

    K160864, K112695, K140072, K153027

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Vitrification Kit is indicated for use in the preparation, vitrification and storage of oocytes (MI), pronuclear (PN) zygotes through day 3 cleavage stage embryos, and blastocyst stage embryos.

    The Thawing Kit is indicated for use in the preparation and thawing of vitrified oocytes (MII), pronuclear (PN) zygotes through day 3 cleavage stage embryos, and blastocyst stage embryos.

    Device Description

    The Vitrification and Thawing Kits are composed of a set of six media to vitrify and warm MII oocytes, and pronuclear (PN) zygotes through blastocyst stage embryos for Assisted Reproductive Technology (ART) procedures.

    The Vitrification Kit includes three media components, Basic Solution (BS), Equilibration Solution (ES) and Vitrification Solution (VS), containing the cryoprotectants ethylene glycol, trehalose, and dimethyl sulfoxide. During the vitrification process, embryos are first exposed to ES and then to VS. In the case of the oocytes, use BS and ES. Using this methodology, the permeating cryoprotectants can replace water in the occyte, PN through blastocyst stage embryos prior to vitrification and storage in liquid nitrogen. The Vitrification Kit comes prepackaged with one 1.5 ml vial of BS and ES, two 1.5 ml vials of VS, 4 Cryotop devices (Cryotop CL, Cryotop SC, or Cryotop US), and 2 Repro Plates.

    The Thawing Kit is composed of three media used stepwise for thawing cryoprotectants from vitrified oocytes, and PN through blastocyst stage embryos. The Thawing Kit is composed of TS (Thawing Solution), DS (Dilution Solution) and WS (Wash Solution). The Thawing Kit comes pre-packaged with two 4.0 ml vials of thawing solution, one 4.0 ml vial of dilution solution, one 4.0 ml vial of washing solution, one Repro Plate, and two 35 mm dishes.

    All the media in the Vitrification Kit contain Gentamicin. The media in these kits undergo aseptic filtration, while storage devices and plates are sterilized by radiation.

    AI/ML Overview

    The provided document describes the Vitrification Kit and Thawing Kit (K171748) and its substantial equivalence to a predicate device. Below is an attempt to extract the requested information, though it's important to note that this document is a 510(k) Summary, which focuses on demonstrating substantial equivalence rather than a full study report with detailed acceptance criteria and performance data in the format often associated with AI/software performance studies. The device is a "Reproductive Media and Supplements," which are chemical reagents, not an AI/software device, so many of the requested fields (like AI-specific performance metrics, reader studies, etc.) are not directly applicable.

    Here's the information based on the provided text:

    Acceptance Criteria and Device Performance

    Since this is a submission for a "Reproductive Media and Supplements" kit, the acceptance criteria are related to the biological outcome (survival, development, etc.) of oocytes and embryos rather than typical device performance metrics like accuracy, sensitivity, or specificity of an AI algorithm. The performance is compared to similar existing products (predicate device or other vitrification media).

    Acceptance Criteria (Bench/Literature Study)Reported Device Performance (as demonstrated by literature or similar device)
    Oocyte Survival Rate (compared to surrogate device/vitrification media with serum substitute)Comparable oocyte survival rate between a surrogate device (with similar formulation and cryoprotectants to the subject device) and vitrification media containing serum substitute supplement. Also, comparable oocyte survival rate to other methods of vitrification.
    Implantation Rate (following vitrification using a surrogate device)Comparable implantation rate between a surrogate device (with similar formulation and cryoprotectants to the subject device) and vitrification media containing serum substitute supplement.
    Clinical Pregnancy Rate (following vitrification using a surrogate device)Comparable clinical pregnancy rate between a surrogate device (with similar formulation and cryoprotectants to the subject device) and vitrification media containing serum substitute supplement.
    Live Birth Rate (following vitrification using a surrogate device)Comparable live birth rate between a surrogate device (with similar formulation and cryoprotectants to the subject device) and vitrification media containing serum substitute supplement. Birth rates following use of vitrified oocytes were shown to be comparable to the methods used in the predicate device.
    Human Blastocyst Survival Rate (compared to surrogate device/vitrification media with serum substitute)Comparable human blastocyst survival rate following vitrification between a surrogate device (with similar formulation to the predicate device) and vitrification media containing serum substitute supplement.
    Fertilization Rate of Oocytes (following vitrification using methods similar to the subject device)Fertilization rate comparable to fresh oocytes.
    Quality Blastocyst Rate (following vitrification using methods similar to the subject device)Quality blastocyst rate comparable to fresh oocytes.
    Survival rates of oocytes and embryos (general consistency with normal ART procedures)Consistent with normal ART procedures using similar IVF treatments and cryopreservation techniques.
    Endotoxin (LAL methodology for Media)< 0.25 EU/mL
    Mouse Embryo Assay (development to blastocyst at 96 hours)> 80% development to blastocyst at 96 hours
    Sterility TestingPasses
    pH Test7.20 - 7.60
    BiocompatibilityPasses
    Sterilization Validation, Packaging Validation, Performance (bench) testing (for identical device cleared under K160864, leveraged in this submission)Passed all testing.

    Study Details

    1. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

      • Sample Size: Not explicitly stated as a single "test set" number. The evidence comes from three published scientific papers.
        • Literature 1 (Coello et al, 2016): Retrospective cohort study.
        • Literature 2 (Mori et al, 2015): Not specified in the summary, but likely a study comparing different methods.
        • Literature 3 (Inoue et al, 2014): Not specified.
      • Data Provenance: Not explicitly stated for all, but Coello et al. is published in Journal of Assisted Reproduction Genetics, typically international. Mori et al. published in Reproductive BioMedicine Online. Inoue et al. in Low Temp Med. Specific countries of origin for the patient data are not detailed in this summary. The studies appear to be retrospective and prospective clinical/bench studies, but specific details for each are not fully provided in this summary.
    2. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

      • Not applicable in the context of this device (Reproductive Media Kit). The "ground truth" for the performance claims would be the observed biological outcomes (survival, fertilization, development to blastocyst, pregnancy, live birth rates) reported in the referenced scientific literature, likely assessed by trained embryologists and clinicians.
    3. Adjudication method (e.g. 2+1, 3+1, none) for the test set

      • Not applicable. This is not an AI/image analysis device requiring expert adjudication of outputs.
    4. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

      • Not applicable. This is not an AI device. The comparison is between different media formulations and vitrification methods.
    5. If a standalone (i.e. algorithm only without human-in-the loop performance) was done

      • Not applicable. This is not an AI/algorithm device.
    6. The type of ground truth used (expert concensus, pathology, outcomes data, etc)

      • The "ground truth" here is outcomes data and biological observations from clinical and laboratory studies reported in published literature, such as oocyte/embryo survival rates, fertilization rates, blastocyst development, implantation rates, clinical pregnancy rates, and live birth rates.
    7. The sample size for the training set

      • Not applicable. This is a medical device (chemical media), not an algorithm or AI model that requires a training set.
    8. How the ground truth for the training set was established

      • Not applicable. (See #7).