Search Filters

Search Results

Found 2 results

510(k) Data Aggregation

    K Number
    K243466

    Validate with FDA (Live)

    Date Cleared
    2025-01-06

    (59 days)

    Product Code
    Regulation Number
    888.3353
    Age Range
    All
    Predicate For
    N/A
    Why did this record match?
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The device is indicated for use in hip arthroplasty in skeletally mature patients with the following conditions:

    1. A severely painful and/or disabled joint from osteoarthritis, traumatic arthritis, rheumatoid arthritis, or congenital hip dysplasia.
    2. Avascular necrosis of the femoral head.
    3. Acute traumatic fracture of the femoral head or neck.
    4. Failed previous hip surgery including joint reconstruction, internal fixation, arthrodesis, hemiarthroplasty, surface replacement or total hip replacement.
    5. Certain cases of ankylosis.
      Conformity stem is for cementless use only.
    Device Description

    The subject device is an extension line of 510(K) cleared device Conformity stem, cementless (K183312, K242249), which introduces four new variations: (1) Conformity stem, #0; (2) Conformity stem, collared, #0; (3) Conformity stem, coxa vara, 125° STD, collared, #0; and (4) Conformity stem, short neck, collared #0. The indications, design rationales, materials, manufacturing process, and sterilization method of the subject devices are identical to the 510(k) cleared Conformity Stem, cementless (K183312, K242249).
    Conformity Stem can collocate with “United” metallic femoral heads (K994078, K022520, K111546, K122504, K152439, K162957, K221675) or ceramic femoral heads (K103497, K112463, K122185).

    • Conformity stem, #0
      Conformity stem, #0 is an extension in terms of sizes to 510 (k) cleared device Conformity stem, #1-11 (K183312). The material, coating thickness, neck angle (135°), and neck length (35.5mm) design are identical to 510 (k) cleared device Conformity Stem, #1, #11 (K183312)The only differences in the items are the offset specifications and stem length.
    • Conformity stem, collared, #0
    • Conformity stem, collared, #0 is an extension in terms of sizes to 510 (k) cleared device Conformity stem, collared, #1-11 (K183312). The material, coating thickness, neck angle (135°), and neck length (35.5mm) design are identical to 510 (k) cleared device Conformity stem, collared, #1, #11 (K183312).The only differences in the items are the offset specifications and stem length.
    • Conformity Stem, coxa vara, 125° STD, collared, #0
    • Conformity Stem, coxa vara, 125° STD, collared, #0 is an extension in terms of sizes to 510 (k) cleared device Conformity stem, coxa vara 125° STD, collared, #1-7 (K242249). The material, coating thickness, neck angle (125°), and neck length (32.5mm) design are identical to 510 (k) cleared device Conformity stem, 125° STD, collared, #1, #7 (K242249). The only differences in the items are the offset specifications and stem length.
    • Conformity Stem, short neck, collared #0
    • Conformity Stem, short neck, collared #0 is an extension in terms of sizes to 510 (k) cleared device Conformity Stem, short neck, collared, #1-7 (K183312 and K242249). The material, coating thickness, neck angle (135°), and neck length (28.5mm) design are identical to 510 (k) cleared device Conformity Stem, short neck, collared, #1, #7 (K183312 and K242249). The only differences in the items are the offset specifications and stem length.
    AI/ML Overview

    The provided text is a 510(k) summary for a medical device (hip stem extension line). It details the device's identity, intended use, and comparison to predicate devices, but it does not contain information about acceptance criteria or a study proving the device meets those criteria, especially not in the context of an AI/ML-driven device.

    The document primarily focuses on demonstrating substantial equivalence to existing legally marketed devices based on:

    1. Identical Indications for Use: The new device has the same indications as the predicate devices.
    2. Similar Technological Characteristics: The material, principle of operation, regulation number, product code, risk class, intended users, fixation method, surface coating, locking mechanism, and sterilization method are the same as the predicate device.
    3. Non-Clinical Performance Data: The submission includes tests like Range of Motion, Neck Fatigue Assessment, Stem Fatigue Test, Characterization of HA Plasma Spray Coating, and Usability Evaluation. These are standard engineering and material tests for orthopedic implants, not AI/ML performance metrics.

    Therefore, I cannot extract the requested information regarding:

    • A table of acceptance criteria and reported device performance (for AI/ML).
    • Sample size and data provenance for a test set (for AI/ML).
    • Number and qualifications of experts for ground truth (for AI/ML).
    • Adjudication method (for AI/ML).
    • MRMC comparative effectiveness study or human reader improvement with AI.
    • Standalone algorithm performance.
    • Type of ground truth (expert consensus, pathology, outcomes data, etc.) for AI/ML validation.
    • Sample size for the training set (for AI/ML).
    • How ground truth for the training set was established (for AI/ML).

    The document is about a physical orthopedic implant and its substantial equivalence based on mechanical and material testing, not an AI/ML diagnostic or assistive device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K242249

    Validate with FDA (Live)

    Date Cleared
    2024-08-30

    (30 days)

    Product Code
    Regulation Number
    888.3353
    Age Range
    All
    Predicate For
    Why did this record match?
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The device is indicated for use in hip arthroplasty in skeletally mature patients with the following conditions:

    1. A severely painful and/or disabled joint from osteoarthritis, traumatic arthritis, rheumatoid arthritis, or congenital hip dysplasia.
    2. Avascular necrosis of the femoral head.
    3. Acute traumatic fracture of the femoral head or neck.
    4. Failed previous hip surgery including joint reconstruction, internal fixation, arthrodesis, hemiarthroplasty, surface replacement or total hip replacement.
    5. Certain cases of ankylosis.
      Conformity stem is for cementless use only.
    Device Description

    The "United" Conformity Stem cementless type (K183312) is designed for cementless use in hip arthroplasty. The Conformity Stem cementless type is a proximal trapezoid and distal quadrangular stem with 12/14 neck taper, 135° and 125° neck angle. It is manufactured from Ti-6Al-4V alloy, which conforms to ASTM F136-13 and the distal part of each femoral stem is coated with hydroxyapatite (HA) (ASTM F1185-03) to provide biological fixation. The "United" Conformity Stem cementless is available in various sizes with collarless and collared types to accommodate various hip surgical requirements.
    For the subject device, it's an extension line of the 510(K) cleared device Conformity Stem cementless type (K183312), which introduces two new variations: (1) Conformity stem, coxa vara, 125° STD, collared, #1-7; and (2) Conformity stem, short neck, #4-7. The indications, design rationales, materials, major manufacturing process, and sterilization method of the subject devices are identical to the 510(k) cleared Conformity Stem, cementless (K183312).
    Conformity Stem can collocate with "United" metallic femoral heads (K994078, K022520, K111546, K122504, K152439, K162957, K221675) or ceramic femoral heads (K103497, K112463, K122185).

    • Conformity stem, coxa vara, 125° STD, collared
      Conformity stem, coxa vara, 125° STD, collared is a new coxa vara type variation of 510(k) cleared Conformity stem, coxa vara (1110-52XX, K183312). The same as this 510(k) cleared device, it's also made of Ti-6Al-4V alloy (ASTM F136), and the distal part is coated with hydroxyapatite(HA) (ASTM F1185). In addition, the subject device is also a collared stem with a 125° neck angle. The only difference is the offset design. The subject device is standard offset, while the 510(k) cleared coxa vara collared stem (110-52XX) is high offset
    • Conformity Stem, short neck, #4-7
      Conformity stem, short neck, #4-7 is an extension in terms of sizes to 510 (k) cleared device Conformity stem, short neck, #1-3 (K183312). The design, material, coating thickness, geometrical characteristics, neck angle (135°), and neck length (28.5mm) design are identical to 510 (k) cleared device Conformity Stem, short neck, #1-3 (K183312). The only different is the stem length sizes.
    AI/ML Overview

    This is an FDA 510(k) clearance letter for a medical device called "Conformity Stem Extension Line." This document does not describe acceptance criteria for an AI/ML device or a study proving that an AI/ML device meets those criteria. Instead, it describes mechanical analyses performed on a physical orthopedic implant.

    Therefore, I cannot extract the requested information regarding acceptance criteria and study details for an AI/ML device from this document. The document pertains to a hip joint prosthesis, which is a physical implant, not a software device.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1