    Reference Devices :

    K201617, K143221

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Camera System: The Camera System is indicated for use in general laparoscopy, ear endoscopy, ear endoscopy, sinuscopy, and plastic surgery whenever a laparoscope/ endoscope/ arthroscope is indicated for use. A few examples of the more common endoscope surgeries are Laparoscopic cholecystectomy, Laparoscopic hernia repair, Laparoscopic appendectomy, Laparoscopic pelvic lymph node detection, Laparoscopically assisted hysterectomy, Laparoscopic and thorascopic anterior spinal fusion, Anterior cruciate ligament reconstruction, Knee arthroscopy, Decompression fixation, Wedge resection, Lung biopsy, Pleural biopsy, Dorsal sympathectomy, Pleurodesis, Internal mammary artery dissection for coronary artery bypass grafting where endoscopic visualization is indicated and Examination of the evacuated cardiac chamber during performance of valve replacement. The users of the Camera System are general surgeons, gynecologists, cardiac surgeons, plastic surgeons, orthopedic surgeons, ENT surgeons and urologists.

    NIR FI Light Source: The NIR FI Light Source and NIR FI Light Guide are indicated for use to provide real-time endoscopic visible and nearinfrared fluorescence imaging. The NIR FI Light Source and NIR FI Light Guide enable surgeons to perform minimally invasive surgery using standard endoscope visual light as well as visual assessment of vessels, blood flow and related tissue perfusion, and at least one of the major extra-hepatic bile duct, common bile duct and common hepatic duct), using near-infrared imaging.

    Fluorescence imaging of biliary ducts with the NIR FI Light Source and NIR FI Light Guide is intended for use with standard-of-care white light and, when indicated, intraoperative cholangiography. The devices are not intended for standalone use for biliary duct visualization.

    Device Description

    The individual components of the subject device, SCHOELL Y's NIR FI System, form a system to provide real-time endoscopic visible imaging (wight light imaging, WLI) and near-infrared (NIR) illumination and imaging (fluorescence imaging, FI) using indocyanine green (ICG):

    • Camera System suitable for processing and recordings visible light images as well as NIR images. The Camera System consists of a Camera Control Unit (CCU) and a Camera Head for connection to a fiberoptic scope;
    • . Light Source and Light Guide for use with a fiberoptic scope for emitting light within the visible spectrum as well as in the NIR spectrum to cause fluorescence;
    • . Fiberoptic Laparoscope suitable for visible light and NIR light illumination and imaging;

    The imaging agent (ICG) is not provided by SCHOELLY as part of the subject system.

    AI/ML Overview

    The submitted information does not contain a study that proves the device meets the acceptance criteria in the format requested. The document primarily focuses on establishing substantial equivalence to a predicate device for regulatory clearance. It describes general performance testing conducted, but not in the context of specific acceptance criteria and detailed study results as typically found in clinical trials or dedicated performance studies for AI/ML devices.

    However, based on the provided text, I can extract information related to the device and the types of testing performed to support its regulatory clearance.

    Here's an attempt to structure the available information, noting where specific details (like acceptance criteria, sample sizes, ground truth establishment, or expert involvement for performance scores) are not explicitly present in the provided document:


    Device Name: Near-Infrared (NIR) Fluorescence Imaging (FI) System: Camera System (Camera Control Unit, Camera Head to be coupled to a fiberoptic scope), NIR FI Light Source

    1. Table of Acceptance Criteria and Reported Device Performance

    The document does not explicitly state quantitative acceptance criteria for device performance (e.g., specific sensitivity, specificity, accuracy targets). Instead, it relies on demonstrating compliance with recognized standards and substantial equivalence to a predicate device.

    Performance AspectAcceptance Criteria (Implicit from regulatory context)Reported Device Performance
    Reprocessing ValidationCompliance with FDA 2015 guidance, AAMI TIR12:2010, AAMI TIR30:2011(R)2016, ANSI/AAMI/ISO 17665-1:2006 (R)2013, ISO 17664:2017."These tests demonstrated that the device successfully passed cleaning, drying and sterilization validations according to the instructions in the user manual."
    Software DocumentationCompliance with FDA's 2005 Guidance for Software, IEC 62304:2006/A1:2016 (MODERATE Level of Concern)."Software documentation for a MODERATE Level of Concern device is provided in support of the proposed device... The software lifecycle, including software documentation and validation, is managed in accordance with IEC 62304:2006/A1:2016..." (Implies compliance).
    Electrical Safety TestingCompliance with IEC 60601-1:2005 + CORR. 1:2006 + CORR. 2:2007 + AM1:2012 and IEC 60601-2-18:2009."The NIR FI System was assessed for conformity with, and was found to comply with, the relevant requirements of IEC 60601-1:2005... and IEC 60601-2-18:2009..."
    Electromagnetic CompatibilityCompliance with IEC 60601-1-2:2014."The NIR FI System was assessed for conformity with, and was found to comply with, the relevant requirements of IEC 60601-1-2:2014..."
    Non-Clinical PerformanceSubstantial equivalence to predicate device (Stryker AIM System) and meeting design input requirements for endoscopic white light and NIR fluorescence imaging."Non-Clinical performance test data demonstrate that the proposed NIR FI System performs substantially equivalent to the Stryker predicate AIM System and that the design output meets the design input requirements for endoscopic white light and near-infrared fluorescence imaging." (No specific quantitative metrics for imaging performance are disclosed in this summary).

    2. Sample Size Used for the Test Set and Data Provenance

    The document does not specify a "test set" in the context of evaluating a dataset for AI performance. The performance data mentioned refers to engineering and quality system validation tests. No information is provided regarding the origin (country, retrospective/prospective) of specific data sets used for validating imaging performance beyond general statements about "non-clinical performance test data."

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Their Qualifications

    Not applicable based on the provided text. The document does not describe a study involving expert readers establishing ground truth for a test set to assess AI performance. The focus is on the device's technical specifications and safety/effectiveness in a comparative context to a predicate device.

    4. Adjudication Method for the Test Set

    Not applicable. As no human expert evaluation of a test set for AI performance is described, no adjudication method is mentioned.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done, and the Effect Size

    No MRMC study is mentioned. The document primarily focuses on demonstrating substantial equivalence to a predicate device through technical comparisons and compliance with standards, rather than a study comparing human readers with and without AI assistance.

    6. If a Standalone (Algorithm Only) Performance Study Was Done

    The device described is a medical imaging system (hardware and integrated functionality for visible and NIR fluorescence imaging), not a standalone AI algorithm. Therefore, a standalone algorithm performance study as typically understood for AI/ML software is not applicable here. The "Non-Clinical Performance Testing" refers to the system as a whole.

    7. The Type of Ground Truth Used

    For the "Non-Clinical Performance Testing," the "ground truth" implicitly refers to the expected performance characteristics based on an existing predicate device and the design input requirements for endoscopic white light and near-infrared fluorescence imaging. The document does not specify an external "ground truth" like pathology, expert consensus on images, or outcomes data.

    8. The Sample Size for the Training Set

    Not applicable. The document does not describe the development or training of an AI algorithm with a training set. The device is an imaging system, not a machine learning model.

    9. How the Ground Truth for the Training Set Was Established

    Not applicable. As there is no mention of a training set or AI algorithm training, the establishment of ground truth for such a set is not discussed.


    Summary of Non-Inclusion:

    The provided document is a 510(k) summary for a medical device (an imaging system) seeking clearance based on substantial equivalence. It is not a report on a clinical or performance study evaluating an AI/ML algorithm against specific performance metrics with independent test sets and expert ground truth. Therefore, many of the requested details, particularly those related to AI/ML study design (sample sizes for test/training sets, expert qualifications, ground truth establishment, MRMC studies), are not present in the given text. The "Performance Data" section details compliance with recognized safety, software, and reprocessing standards, and general non-clinical performance demonstrations for substantial equivalence.

    Ask a Question

    Ask a specific question about this device

    K Number
    K201151

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2020-06-22

    (54 days)

    Product Code
    Regulation Number
    876.1500
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K143221, K910132

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The O-Mec Laparoscopes 690 Series (Models, 90-331000H, 690-300500H, 690-300500H, are intended to be used by surgeons in diagnostic and therapeutic procedures. Laparoscopic minimally invasive procedures are performed in the abdominal cavity by means of small skin punctures that allow the insertion of the laparoscope and laparoscopic instruments.

    Device Description

    O-Mec laparoscopes 690 Series Models 690- 331000H, 690-331030H, 690-300500H, 690-300530H are rigid endoscopes that are used to view a patient's internal anatomy for examination, diagnosis and therapy during laparoscopic procedures. An endoscope is a slender, tubular optical instrument used as a viewing system for examining an inner part of the body. The inside of the endoscope contains a series of lenses that transmit the endoscopic image, which is illuminated by an external light source.

    O-Mec laparoscopes 690 Series Models 690- 331000H, 690-331030H, 690-300500H, 690-300530H are available in two sizes: 5mm or 10mm diameters, with either 0° or 30° directions of view. O-Mec laparoscope provides a high definition image and can correct chromatic aberration in the 400-900nm wavelength range.

    O-Mec laparoscopes 690 Series Models 690- 331000H, 690-331030H, 690-300500H, 690-300530H are delivered non-sterile and are reusable and fully autoclavable. O-Mec laparoscopes must be cleaned according to the Instructions of Use before each use.

    AI/ML Overview

    The provided text describes the O-Mec Laparoscopes 690 Series and its substantial equivalence to predicate devices, but it does not contain information related to AI/ML device performance, acceptance criteria for AI/ML, or studies explicitly designed to prove an AI/ML device meets such criteria.

    The document is a 510(k) Pre-Market Notification for a traditional medical device (laparoscopes). The "acceptance criteria" discussed are for the physical and functional performance of the laparoscope itself (e.g., optical performance, sterilization validation, electrical safety) in comparison to predicate devices, not for an AI/ML algorithm's diagnostic or predictive capabilities.

    Therefore, I cannot extract the requested information, such as:

    1. A table of acceptance criteria and reported device performance for an AI/ML device.
    2. Sample sizes used for test sets (for AI/ML), data provenance, etc.
    3. Number of experts, qualifications, and adjudication methods for AI/ML ground truth.
    4. MRMC comparative effectiveness study details (AI vs. human).
    5. Standalone performance of an AI algorithm.
    6. Type of ground truth used (for AI/ML).
    7. Sample size for the training set (for AI/ML).
    8. How ground truth for the training set was established (for AI/ML).

    The document explicitly states: "Clinical testing was not performed with this device." and the "Summary of Non-Clinical Testing" focuses on hardware performance, cleaning, and safety. There is no mention of an AI/ML component or any associated performance metrics or studies.