Search Filters

Search Results

Found 1 results

510(k) Data Aggregation

    K Number
    K201166

    Validate with FDA (Live)

    Date Cleared
    2020-08-28

    (119 days)

    Product Code
    Regulation Number
    876.1075
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K171953, K141552

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Temno Elite Biopsy System is intended for use in obtaining biopsies from soft tissues such as liver, kidney,breast,prostate, spleen,lung,lymph nodes,thyroid,and various soft tissue masses. It is NOT intended for use in bone.

    The Valved Coaxial Introducer Needle and Standard Coaxial Introducer Needles are intended for use as guiding needle in obtaining core biopsy samples from soft tissue such as liver, kidney,prostate,spleen, lung,lymph nodes,thyroid, and various soft tissue masses. It is NOT intended for use in bone.

    Device Description

    The subject device is a single use full core biopsy device. It is available in several gauge sizes and lengths. The device has printed gauge size indicator that is color coded according to the various gauge sizes (yellow= 20G, pink= 18G, purple= 16 G, green= 14G, and blue=12G. The needles have a protective sheath.

    The Temno Elite Biopsy system includes Biopsy device and has the option of including a Valved Coaxial Introducer Needle, or a Standard Coaxial Introducer Needle. The depth stop on both the Valved Coaxial Introducer Needle and the Standard Coaxial Introducer Needle is color coded to match the gauge size of the Temno Elite Biopsy system.

    The Temno Elite Biopsy System is supplies sterile and is intended for single use only.

    AI/ML Overview

    The provided text describes the Temno Elite Biopsy System, which is a medical device. The text focuses on the device's substantial equivalence to predicate devices, its indications for use, and the performance testing conducted to demonstrate its safety and efficacy.

    However, the text does not contain any information about acceptance criteria and the study that proves the device meets those acceptance criteria in the context of an AI/human-in-the-loop system, image analysis, or diagnostic accuracy study. The device described is a physical biopsy instrument used for obtaining tissue samples from various soft tissues. The performance data presented refers to bench testing, biocompatibility, and sterilization, which are standard for physical medical devices, not for AI-powered diagnostic tools.

    Therefore, I cannot fulfill the request to describe acceptance criteria and a study proving device performance using AI-specific metrics (e.g., sample size for test/training sets, ground truth establishment for AI, expert consensus, MRMC studies, standalone performance, effect size of human improvement with AI) because the provided document does not pertain to such a device or study.

    The document discusses:

    • Device: Temno Elite Biopsy System (a physical biopsy instrument)
    • Indications for Use: Obtaining biopsies from soft tissues (liver, kidney, breast, prostate, spleen, lung, lymph nodes, thyroid, and various soft tissue masses).
    • Acceptance Criteria/Performance Testing: These are related to the physical attributes and safety of the biopsy device itself, such as dimensional verification, tensile strength of joints, adjustable throw accuracy, multiple samples, device visibility, simulated use, biocompatibility (cytotoxicity, sensitization, irritation, systemic toxicity, pyrogenicity), and sterilization standards.

    In summary, the provided text does not contain the information needed to answer the prompt regarding AI/imaging-related acceptance criteria and study data.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1