Search Filters

Search Results

Found 8 results

510(k) Data Aggregation

    K Number
    K232030

    Validate with FDA (Live)

    Date Cleared
    2023-08-02

    (26 days)

    Product Code
    Regulation Number
    892.1000
    Age Range
    All
    Predicate For
    N/A
    Why did this record match?
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Philips Magnetic Resonance (MR) systems are Medical Electrical Systems indicated for use as a diagnostic device. This MR system enables trained physicians to obtain cross-sectional images, spectroscopic images and/or spectra of the internal structure of the head, body or extremities, in any orientation, representing the spatial distribution of protons or other nuclei with spin.

    Image appearance is determined by many different physical properties of the tissue and the MR scan technique applied, and presence of contrast agents. The use of contrast imaging applications should be performed consistent with the approved labeling for the contrast agent.

    The trained clinical user can adjust the MR scan parameters to customize image appearance, accelerate image acquisition, and synchronize with the patient's breathing or cardiac cycle.

    The systems can use combinations of images to produce physical parameters, and related derived images, spectra, and measurements of physical parameters, when interpreted by a trained physician, provide information that may assust diagnosis and therapy planning. The accuracy of determined physical parameters depends on system and scan parameters, and must be controlled and validated by the clinical user.

    In addition the Philips MR systems provide imaging capabilities, such as MR fluoroscopy, to guide and evaluate interventional and minimally invasive procedures in the head, body and extremities. MR Interventional procedures, performed inside or adjacent to the Philips MR system, must be performed with MR Conditional or MR Safe instrumentation as selected and evaluated by the clinical user for use with the specific MR system configuration in the hospital. The appropriateness and use of information from a Philips MR system for a specific interventional procedure and specific MR system configuration must be validated by the clinical user.

    Device Description

    This Special 510(k) submission will include modifications of the proposed Ingenia Elition R5.7.1 SP4 MR Systems as compared to Philips legally marketed predicate device Ingenia Elition of the 510(k) submission Achieva, Intera, Ingenia, Ingenia CX, Ingenia Elition and Ingenia Ambition MR Systems (K193215, 04/10/2020).

    In this 510(k) submission, Philips Medical Systems Nederland B.V. will be addressing the following minor software enhancements for the proposed Ingenia Elition R5.7.1 SP4 MR Systems:

    1. Introduction of a persistence latch which will prevent the currently available Interlock of SmokeDetector to be reset by customer, which is against the current labeling (abnormal use).
    2. The UI (User Interface) and IfU (Instructions for Use) are also updated to provide clear instructions for the user in case the currently available SmokeDetector Alarm Interlock is activated and to further clarify current instructions to prevent powercycling the system (abnormal use).
    3. SW Compatibility with the PD-Break Heat Detector

    Identical to the predicate device, the proposed Ingenia Elition R5.7.1 SP4 MR Systems is intended to be marketed with the following pulse sequences and coils that are previously cleared by FDA:

    1. mDIXON (K102344)
    2. SWIp (K131241)
    3. mDIXON-Quant (K133526)
    4. MRE (K140666)
    5. mDIXON XD (K143128)
    6. O-MAR (K143253)
    7. 3D APT (K172920)
    8. Compatible System Coils (identical to the predicate devices)
    AI/ML Overview

    The provided document, a 510(k) Summary for Philips Medical Systems Nederland B.V.'s Ingenia Elition R5.7.1 SP4 MR Systems, focuses on demonstrating substantial equivalence to a predicate device. It addresses minor software enhancements, specifically related to a persistence latch for a SmokeDetector interlock, UI/IfU updates for the SmokeDetector alarm, and SW compatibility with a PD-Break Heat Detector.

    Crucially, this document states that "The proposed Ingenia Elition R5.7.1 SP4 MR Systems did not introduce any modification to the indication for use or technological characteristics relative to the predicate devices that would require clinical testing." This implies that the device is not an AI/ML-powered medical device that would involve a study proving how AI-assistance improves human reader performance or the standalone performance of an AI algorithm.

    Therefore, the requested information regarding acceptance criteria and a study proving the device meets those criteria, specifically concerning AI/ML performance, cannot be extracted from this document, as it describes a non-AI/ML device undergoing a Special 510(k) for minor software changes. The "acceptance criteria" discussed are related to compliance with consensus standards and general safety/performance, not AI/ML specific metrics.

    However, based on the non-clinical performance data and the conclusion, we can infer the acceptance criteria for the software changes and how the device (with these changes) meets them.

    Inferred Acceptance Criteria and Device Performance (for software changes)

    Since the submission is a "Special 510(k)" for minor software enhancements, the acceptance criteria are primarily related to maintaining the safety and effectiveness of the existing, cleared device, and ensuring compliance with updated standards.

    Acceptance Criteria (inferred for software modifications)Reported Device Performance (from document)
    Safety and Effectiveness Equivalence:"Therefore, the proposed Ingenia Elition R5.7.1 SP4 MR Systems are substantially equivalent to the legally marketed predicate device Ingenia Elition of the 510(k) submission... in terms of safety and effectiveness."
    Compliance with Consensus Standards:"Identical to the predicate device, the proposed Ingenia Elition R5.7.1 SP4 MR Systems are in compliance with the following international and FDA-recognized consensus standards:" (list includes IEC60601-2-33, ANSI/AAMI ES60601-1, IEC60601-1-2, IEC60601-1-6, IEC 60601-1-8, ISO 14971, IEC 62366-1, IEC 62304). The document implies that new software hasn't caused non-compliance issues.
    Risk Mitigation:"Additionally, the risk management activities show that all risks are sufficiently mitigated; that new risks that were identified are mitigated to an acceptable level; and that the overall residual risk is acceptable."
    Functional Verification of Changes:"Non-Clinical verification tests were deemed necessary with regards to the requirement specifications and the risk management results. The verification test results demonstrate that the proposed Ingenia Elition R5.7.1 SP4 MR Systems meet the acceptance criteria and are adequate for the intended use." (Specifically for persistence latch, UI/IfU updates related to SmokeDetector, and PD-Break Heat Detector compatibility). "The validation testing performed with the predicate device remain valid for the changes introduced with the proposed device Ingenia Elition R5.7.1 SP4 MR Systems."

    Information Not Applicable/Provided for an AI/ML Device

    The following points are specifically requested for AI/ML-powered medical devices and are not applicable to this 510(k) summary, as it describes a conventional MR system with minor software updates.

    1. Sample size used for the test set and the data provenance: Not applicable. No specific test set data for AI/ML performance is presented. The testing pertains to software verification and compliance with standards.
    2. Number of experts used to establish the ground truth for the test set and the qualifications of those experts: Not applicable. No clinical ground truth establishment for AI/ML performance.
    3. Adjudication method (e.g. 2+1, 3+1, none) for the test set: Not applicable.
    4. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance: Not applicable. This device is not AI-assisted.
    5. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done: Not applicable. This is not an AI algorithm.
    6. The type of ground truth used (expert consensus, pathology, outcomes data, etc.): Not applicable.
    7. The sample size for the training set: Not applicable. This is not an AI/ML device requiring a training set in the context of machine learning.
    8. How the ground truth for the training set was established: Not applicable.

    In summary, this 510(k) document indicates that the device is a Philips MR system with minor software changes and not an AI/ML-powered device. Therefore, the detailed AI/ML-specific study information requested is not present. The acceptance criteria and performance data are related to general device safety, effectiveness, and compliance with established medical device standards for MR systems.

    Ask a Question

    Ask a specific question about this device

    K Number
    K230972

    Validate with FDA (Live)

    Date Cleared
    2023-04-28

    (23 days)

    Product Code
    Regulation Number
    892.1000
    Age Range
    All
    Predicate For
    N/A
    Why did this record match?
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Philips Magnetic Resonance (MR) systems are Medical Electrical Systems indicated for use as a diagnostic device. This MR system enables trained physicians to obtain cross-sectional images, spectroscopic images and/or spectra of the internal structure of the head, body or extremities, in any orientation, representing the spatial distribution of protons or other nuclei with spin. Image appearance is determined by many different physical properties of the tissue and the MR scan technique applied, and presence of contrast agents. The use of contrast imaging applications should be performed consistent with the approved labeling for the contrast agent. The trained clinical user can adjust the MR scan parameters to customize image appearance, accelerate image acquisition, and synchronize with the patient's breathing or cardiac cycle. The systems can use combinations of images to produce physical parameters, and related derived images, spectra, and measurements of physical parameters, when interpreted by a trained physician, provide information that may assust diagnosis and therapy planning. The accuracy of determined physical parameters depends on system and scan parameters, and must be controlled and validated by the clinical user. In addition the Philips MR systems provide imaging capabilities, such as MR fluoroscopy, to guide and evaluate interventional and minimally invasive procedures in the head, body and extremities. MR Interventional procedures, performed inside or adjacent to the Philips MR system, must be performed with MR Conditional or MR Safe instrumentation as selected and evaluated by the clinical user for use with the specific MR system configuration in the hospital. The appropriateness and use of information from a Philips MR system for a specific interventional procedure and specific MR system configuration must be validated by the clinical user.

    Device Description

    This Special 510(k) submission will include modifications of the proposed Ingenia Elition and MR 7700 MR Systems as compared to Philips legally marketed devices, primary predicate device MR 7700 R11 MR System of the 510(k) submission MR 5300 and MR 7700 R11 MR Systems (K223442, 12/23/2022) as well as the secondary predicate device being the legally marketed Ingenia Elition R11 MR System of the 510(k) submission Achieva, Ingenia, Ingenia CX, Ingenia Elition and Ingenia Ambition MR Systems R11 (K213583, 04/15/2022). In this 510(k) submission, Philips Medical Systems Nederland B.V. will be addressing the following minor hardware enhancements for the proposed Ingenia Elition and MR 7700 MR Systems since the last 510(k) submission (K223442, 12/23/2022) for each of the systems: 1. The SmokeDetector Interlock, a component used in the legally marketed Ingenia Elition and MR 7700 systems, becomes a mandatory risk control measure. 2. Minor design change to current gradient coil type WB30S Identical to the predicate devices, the proposed Ingenia Elition and MR 7700 MR Systems are intended to be marketed with the following pulse sequences and coils that are previously cleared by FDA: 1. mDIXON (K102344) 2. SWIp (K131241) 3. mDIXON-Quant (K133526) 4. MRE (K140666) 5. mDIXON XD (K143128) 6. O-MAR (K143253) 7. 3D APT (K172920) 8. Compatible System Coils (identical to the predicate devices)

    AI/ML Overview

    The provided FDA 510(k) summary for the Philips Ingenia Elition and MR 7700 MR Systems does not contain information about acceptance criteria or a study that proves the device meets specific performance criteria in the context of an AI/human-in-the-loop study. Instead, this submission is for minor hardware enhancements and focuses on demonstrating substantial equivalence to previously cleared predicate devices through compliance with recognized standards and non-clinical verification tests.

    Therefore, I cannot provide details for most of the requested information points, as they are not present in the given text. The submission explicitly states: "The proposed Ingenia Elition and MR 7700 MR Systems did not introduce any modification to the indication for use or technological characteristics relative to the predicate devices that would require clinical testing."

    However, I can extract information related to the non-clinical performance data and the general approach.

    Here's the breakdown of what can be inferred and what cannot:

    1. A table of acceptance criteria and the reported device performance

    Acceptance Criteria (Inferred)Reported Device Performance (Inferred)
    Compliance with IEC 60601-2-33 (Medical electrical equipment - Part 2-33: Particular requirements for the basic safety and essential performance of magnetic resonance equipment for medical diagnosis)Verification test results demonstrate that the proposed Ingenia Elition and MR 7700 MR Systems meet the acceptance criteria and are adequate for the intended use.
    Compliance with ANSI/AAMI ES60601-1 (Medical Electrical Equipment - Part 1: General Requirements For Basic Safety And Essential Performance)Verification test results demonstrate that the proposed Ingenia Elition and MR 7700 MR Systems meet the acceptance criteria and are adequate for the intended use.
    Compliance with IEC 60601-1-2 (Electromagnetic disturbances Requirements and tests)Verification test results demonstrate that the proposed Ingenia Elition and MR 7700 MR Systems meet the acceptance criteria and are adequate for the intended use.
    Compliance with IEC 60601-1-6 (Usability)Verification test results demonstrate that the proposed Ingenia Elition and MR 7700 MR Systems meet the acceptance criteria and are adequate for the intended use.
    Compliance with IEC 60601-1-8 (Alarm systems)Verification test results demonstrate that the proposed Ingenia Elition and MR 7700 MR Systems meet the acceptance criteria and are adequate for the intended use.
    Compliance with ISO 14971 (Application of risk management to medical devices)Risk management activities show that all risks are sufficiently mitigated; new risks identified are mitigated to an acceptable level; and overall residual risk is acceptable.
    Compliance with IEC 62366-1 (Application of usability engineering to medical devices)Verification test results demonstrate that the proposed Ingenia Elition and MR 7700 MR Systems meet the acceptance criteria and are adequate for the intended use.
    Compliance with IEC 62304 (Medical device software - Software life cycle processes)Verification test results demonstrate that the proposed Ingenia Elition and MR 7700 MR Systems meet the acceptance criteria and are adequate for the intended use.
    No significant changes to the essential performance and safety of the device compared to predicate.Non-clinical verification tests performed with regards to requirement specifications and risk management demonstrate the device meets acceptance criteria and is adequate for intended use. Validation testing performed with primary and secondary predicate devices remains valid.

    2. Sample sized used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    • Not provided. The submission focuses on non-clinical verification tests against standards for hardware modifications, not performance on a specific dataset.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    • Not applicable/provided. No clinical study involving expert ground truth is described. The assessment is based on engineering verification and compliance with standards.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    • Not applicable/provided. No clinical study is described.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • No, not done. This submission is for minor hardware enhancements to an MR system, not for an AI-powered diagnostic aid, and therefore, no MRMC study or AI assistance evaluation is mentioned.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    • No, not done. As mentioned, this is not an AI-powered device.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    • Not applicable/provided. For the purpose of this submission, the "ground truth" for the device's acceptable performance is defined by compliance with established international and FDA-recognized consensus standards for medical electrical equipment and risk management.

    8. The sample size for the training set

    • Not applicable/provided. There is no mention of a training set as this is not an AI/machine learning device submission.

    9. How the ground truth for the training set was established

    • Not applicable/provided. There is no mention of a training set.
    Ask a Question

    Ask a specific question about this device

    K Number
    K223442

    Validate with FDA (Live)

    Date Cleared
    2022-12-23

    (39 days)

    Product Code
    Regulation Number
    892.1000
    Age Range
    All
    Predicate For
    Why did this record match?
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Philips Magnetic Resonance (MR) systems are Medical Electrical Systems indicated for use as a diagnostic device. This MR system enables trained physicians to obtain cross-sectional images, spectroscopic images and/or spectra of the internal structure of the head, body or extremities, in any orientation, representing the spatial distribution of protons or other nuclei with spin.

    Image appearance is determined by many different physical properties of the tissue and the anatomy, the MR scan technique applied, and presence of contrast agents. The use of contrast agents for diagnostic imaging applications should be performed consistent with the approved labeling for the contrast agent.

    The trained clinical user can adjust the MR scan parameters to customize image appearance, accelerate image acquisition, and synchronize with the patient's breathing or cardiac cycle. The systems can use combinations of images to produce physical parameters, and related derived images. Images, spectra, and measurements of physical parameters, when interpreted by a trained physician, provide information that may assist diagnosis and therapy planning. The accuracy of determined physical parameters depends on system and scan parameters and must be controlled and validated by the clinical user.

    In addition, the Philips MR systems provide imaging capabilities, such as MR fluoroscopy, to guide and evaluate interventional and minimally invasive procedures in the head, body and extremities. MR Interventional procedures, performed inside or adjacent to the Philips MR system, must be performed with MR Conditional or MR Safe instrumentation as selected and evaluated by the clinical user for use with the specific MR system configuration in the hospital. The appropriateness and use of information from a Philips MR system for a specific interventional procedure and specific MR system configuration must be validated by the clinical user.

    Device Description

    The proposed MR 5300 and MR 7700 R11 MR Systems are 60 cm and 70 cm bore 1.5 and 3.0 Tesla (1.5T and 3.0T) Magnetic Resonance Diagnostic Devices, hereafter to be known as MR 5300 and MR 7700 MR Systems.

    This Special 510(k) submission will include modifications of the proposed MR 5300 and MR 7700 R11 MR Systems as compared to our legally marketed devices, primary predicate device Achieva, Ingenia, Ingenia CX, Ingenia Elition and Ingenia Ambition MR Systems R11 (K213583, 05/16/2022) and the secondary predicate devices Ingenia 3.0T, Ingenia 3.0T CX, Ingenia Elition, and MR 7700 with distributed Multi Nuclei (K213516, 03/03/2022) and MR 5300 (K212673, 11/19/2021).

    The proposed MR 5300 and MR 7700 MR systems will be brought up to the new baseline software R11. This R11 software is cleared on the Achieva, Ingenia, Ingenia CX, Ingenia Elition, and Ingenia Ambition MR Systems in the following primary predicate 510(k) Achieva, Ingenia, Ingenia CX, Ingenia Elition and Ingenia Ambition MR Systems R11 (K213583, 04/15/2022). Both the proposed MR 5300 and MR 7700 MR systems are already cleared with the secondary predicate devices Ingenia 3.0T, Ingenia 3.0T CX, Ingenia Elition, and MR 7700 with distributed Multi Nuclei (K213516, 03/03/2022) and MR 5300 (K212673, 11/19/2021).

    AI/ML Overview

    Here's an analysis of the acceptance criteria and study information provided in the document:

    1. Table of Acceptance Criteria and Reported Device Performance:

    The document states: "The verification and/or validation test results demonstrate that the proposed MR 5300 and MR 7700 R11 MR Systems meet the acceptance criteria and are adequate for the intended use." and "The results of these tests demonstrate that the proposed MR 5300 and MR 7700 R11 MR Systems meet the acceptance criteria and are adequate for the intended use."

    However, the provided text does not explicitly list specific acceptance criteria in a tabular format, nor does it quantify specific performance metrics for the device against such criteria. Instead, it refers to broad compliance with standards and successful completion of verification/validation tests. The device's performance is implicitly stated as "meeting the acceptance criteria" of these tests and compliance with recognized standards.

    2. Sample Size Used for the Test Set and Data Provenance:

    The document broadly mentions "Non-Clinical verification and or validation tests have been performed with regards to the intended use, the technical claims, the requirement specifications and the risk management results."

    However, the text does not provide any details about the sample size (e.g., number of cases, number of images) used for these non-clinical verification and validation tests. It also does not specify the data provenance (e.g., country of origin, retrospective or prospective nature) of any data used in these tests.

    3. Number of Experts Used to Establish Ground Truth and Qualifications:

    The document makes no mention of experts being used to establish ground truth for a test set. The validation primarily focuses on technical compliance and functional verification against internal specifications and external standards.

    4. Adjudication Method for the Test Set:

    No information is provided regarding an adjudication method. This is consistent with the lack of expert involvement in establishing ground truth for a test set described in the document.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study:

    The document explicitly states: "The proposed Ingenia MR 5300 and MR 7700 R11 MR Systems did not require a clinical study since substantial equivalence to the legally marketed predicate device was proven with the verification/validation testing."

    Therefore, no MRMC comparative effectiveness study was done, and consequently, no effect size of human readers improving with AI vs. without AI assistance is reported.

    6. Standalone (Algorithm Only Without Human-in-the-Loop Performance) Study:

    The device is an MR System, a diagnostic imaging device. The various software enhancements (e.g., SmartSpeed AI, SmartSpeed MotionFree) listed are features of the MR system. The evaluation appears to be of the integrated system's technical and safety compliance rather than a standalone algorithm with distinct performance metrics evaluated without human intervention. The provided text does not describe a standalone algorithm-only performance study.

    7. Type of Ground Truth Used:

    Given that the document describes "Non-Clinical verification and or validation tests" and mentions compliance with "technical claims, the requirement specifications and the risk management results," the "ground truth" for the tests appears to be technical specifications, functional requirements, and established industry standards rather than expert consensus on medical images, pathology results, or outcomes data. The clearance is based on substantial equivalence to predicate devices demonstrated through these non-clinical tests.

    8. Sample Size for the Training Set:

    The document does not provide any information regarding a training set sample size. This is consistent with the nature of the submission, which focuses on hardware and software enhancements to existing medical devices rather than the development and validation of a new AI model requiring a separate training dataset. The AI functions mentioned (SmartSpeed AI) are integrated into the system, and their validation is part of the overall system's non-clinical testing.

    9. How the Ground Truth for the Training Set Was Established:

    As no training set is described, no information is provided on how ground truth for a training set was established.

    Ask a Question

    Ask a specific question about this device

    K Number
    K213583

    Validate with FDA (Live)

    Date Cleared
    2022-05-16

    (185 days)

    Product Code
    Regulation Number
    892.1000
    Age Range
    All
    Predicate For
    Why did this record match?
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Philips Magnetic Resonance (MR) systems are Medical Electrical Systems indicated for use as a diagnostic device. This MR system enables trained physicians to obtain cross-sectional images and/or spectra of the internal structure of the head, body or extremities, in any orientation, representing the spatial distribution of protons or other nuclei with spin. Image appearance is determined by many different physical properties of the tissue and the anatomy, the MR scan technique applied, and presence of contrast agents for diagnostic imaging applications should be performed consistent with the approved labeling for the contrast agent. The trained clinical user can adjust the MR scan parameters to customize image appearance, accelerate image acquisition, and synchronize with the patient's breathing or cardiac cycle. The systems can use combinations of images to produce physical parameters, and related derived images, spectra, and measurements of physical parameters, when interpreted by a trained physician, provide information that may assist diagnosis and therapy planning. The accuracy of determined physical parameters depends on system and scan parameters, and must be controlled and validated by the clinical user. In addition the Philips MR systems provide imaging capabilities, such as MR fluoroscopy, to guide and evaluate interventional and minimally invasive procedures in the head, body and extremities. MR Interventional procedures, performed inside or adjacent to the Philips MR system, must be performed with MR Conditional or MR Safe instrumentation as selected and evaluated by the clinical user for use with the system configuration in the hospital. The appropriateness and use of information from a Philips MR system for a specific interventional procedure and specific MR system configuration must be validated by the clinical user.

    Device Description

    The proposed Achieva, Ingenia, Ingenia CX, Ingenia Elition and Ingenia Ambition MR Systems R11.0 are 60 cm and 70 cm bore 1.5 and 3.0 Tesla (1.5T and 3.0T) Magnetic Resonance Diagnostic Devices, hereafter to be known as Achieva, Ingenia, Ingenia CX, Ingenia Elition and Ingenia Ambition MR Systems. This bundled abbreviated 510(k) submission will include modifications of the Achieva, Ingenia, Ingenia CX, Ingenia Elition and Ingenia Ambition MR Systems as compared to our legally marketed devices Achieva, Intera, Ingenia, Ingenia CX, Ingenia Elition and Ingenia Ambition MR Systems R5.7 (K193215, 04/10/2020). In this 510(k) submission, Philips Medical Systems Nederland B.V. will be addressing the following minor software enhancements to the proposed Achieva, Ingenia, Ingenia CX, Ingenia Elition and Ingenia Ambition MR Systems when compared to the legally marketed predicate Achieva, Intera, Ingenia, Ingenia CX, Ingenia Elition and Ingenia Ambition MR Systems R5.7 (K193215, 04/10/2020): 1. SmartSpeed AI 2. SmartSpeed MotionFree 3. SmartSpeed 3D FreeBreathing 4. SmartSpeed Implant 5. SmartSpeed DWI 6. MR Workspace 7. ISP MR Packages 8. Extended functionality Options This 510(k) submission will also address the following minor hardware enhancements: 1. Introduction of a graphical processing unit in the host recon computer for image reconstruction 2. Additional monitor as part of the operating console The supporting documentation provided for the proposed Achieva, Ingenia, Ingenia CX, Ingenia Elition and Ingenia Ambition MR Systems, includes software and hardware modifications that are addressed in test reports for system level development project, Voyager. The proposed Achieva, Ingenia, Ingenia CX, Ingenia Elition and Ingenia Ambition MR Systems are intended to be marketed with the following pulse sequences and coils that are previously cleared by FDA: 1. mDIXON (K102344) 2. SWIp (K131241) 3. mDIXON-Quant (K133526) 4. MRE (K140666) 5. mDIXON XD (K143128) 6. O-MAR (K143253) 7. 3D APT (K172920) 8. Compatible System Coils

    AI/ML Overview

    The provided text describes modifications to Philips MR systems, specifically the integration of "SmartSpeed AI" which combines previously cleared Compressed-SENSE with machine learning for improved image acquisition. The document focuses on demonstrating substantial equivalence to a predicate device rather than outright proving a novel device's performance against clinical endpoints.

    Here's an analysis of the acceptance criteria and study data based on the provided text:

    1. A table of acceptance criteria and the reported device performance:

    The document doesn't explicitly present a formal "acceptance criteria table" with numerical targets. Instead, it describes the performance goals qualitatively, primarily focusing on "equivalent or better image quality" compared to images acquired without SmartSpeed AI but with longer scan times. The acceptance criteria essentially revolve around demonstrating that the new SmartSpeed AI feature does not negatively impact image quality and, ideally, improves it, especially at higher acceleration factors and lower SNR.

    Acceptance Criteria (Qualitative)Reported Device Performance
    Comparable or better results than data reconstructed without SmartSpeed AI ("fully sampled ground truth data" and "data reconstructed without SmartSpeed AI" are used as benchmarks)."SmartSpeed AI does provide comparable or better results than the data reconstructed without SmartSpeed AI." "SmartSpeed AI showed better alignment with the ground truth data for high acceleration factors and low SNR levels compared to the data reconstructed without SmartSpeed AI."
    Does not negatively impact image quality measures when acquired with reduced scan time."In vivo images were analyzed to confirm that SmartSpeed AI does not negatively impact image quality measures when acquired with reduced scan time."
    Images with equivalent or better image quality when comparing SmartSpeed AI images acquired with shorter scan times to images without SmartSpeed AI acquired with longer scan times."The combined results of the comparison described above confirmed that the SmartSpeed AI feature provides images with equivalent or better image quality."

    2. Sample size used for the test set and the data provenance (e.g., country of origin of the data, retrospective or prospective):

    • Test Set Sample Size: The document does not specify a numerical sample size for the test set (number of images or patients). It mentions "a variety of datasets from different anatomies and image contrasts, varying SNR levels and acceleration factors" for pixel-wise comparison, and "in vivo images" for image quality analysis. For the reader evaluation study, it mentions "SmartSpeed AI images acquired across a variety of pulse sequences and anatomies."
    • Data Provenance: Not explicitly stated. The phrase "in vivo images" and "a variety of datasets" implies real patient data, but the origin (e.g., country) is not mentioned, nor is whether the data was retrospective or prospectively collected for this study. Given it's a 510(k) for an upgrade, retrospective data is plausible.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g., radiologist with 10 years of experience):

    • Number of Experts: "A reader evaluation study with US board certified radiologists was performed." The exact number of radiologists is not specified, only that it was plural ("radiologists").
    • Qualifications of Experts: "US board certified radiologists." No further details on their experience level (e.g., years of experience, subspecialty) are provided.

    4. Adjudication method (e.g., 2+1, 3+1, none) for the test set:

    The document states: "Radiologists were asked to perform comparisons of SmartSpeed AI images acquired with shorter scan times and images without SmartSpeed AI acquired with longer scan times." It does not describe any specific adjudication method (e.g., consensus reading, majority vote) if there were multiple readers. It simply states "The combined results of the comparison described above confirmed..." suggesting an aggregation of individual reader opinions.

    5. If a multi-reader, multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    • MRMC Study: A reader evaluation study was performed, which is a type of MRMC study. However, this study was not designed to measure "how much human readers improve with AI vs. without AI assistance." Instead, it was designed to compare the image quality of SmartSpeed AI images (shorter scan time) against non-SmartSpeed AI images (longer scan time), with human readers providing the comparison. The goal was to show non-inferiority or superiority in image quality, not an improvement in diagnostic performance of the human reader.
    • Effect Size: No effect size regarding human reader improvement is reported because that was not the objective of the study. The study aimed to assess equivalent or better image quality of the AI-processed images.

    6. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done:

    Yes, a standalone performance assessment was done. The document states:

    • "A pixel-wise comparison was performed to confirm that SmartSpeed AI does provide comparable or better results than the data reconstructed without SmartSpeed AI."
    • "SmartSpeed AI showed better alignment with the ground truth data for high acceleration factors and low SNR levels compared to the data reconstructed without SmartSpeed AI."
    • "In vivo images were analyzed to confirm that SmartSpeed AI does not negatively impact image quality measures when acquired with reduced scan time."

    These directly assess the algorithm's output (image quality) without human interpretation in the loop as the primary endpoint for these specific analyses.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

    The ground truth for the pixel-wise comparison was "fully sampled ground truth data." This implies a reference image acquired with conventional, unaccelerated scanning techniques, which is considered the "true" or ideal image without any AI reconstruction. For the in vivo image quality assessment and reader study, the ground truth was essentially the "image quality" as perceived by "US board certified radiologists" in comparison to the non-AI enhanced, longer-scan-time images. It's a comparative ground truth based on expert perception rather than a definitive clinical diagnosis or pathology.

    8. The sample size for the training set:

    The document does not specify the sample size for the training set used for the "SmartSpeed AI" machine learning component.

    9. How the ground truth for the training set was established:

    The document mentions that SmartSpeed AI "combining the previously cleared and legally marketed feature Compressed-SENSE... with machine learning." Given the context of image reconstruction and enhancement, it's highly probable the training ground truth involved pairs of unaccelerated (or conventionally accelerated) MR images and corresponding undersampled or noisy MR data, allowing the AI to learn to reconstruct high-quality images from suboptimal inputs. However, the exact method for establishing this ground truth (e.g., specific image acquisition protocols, expert annotation for quality metrics) is not detailed in the provided text.

    Ask a Question

    Ask a specific question about this device

    K Number
    K201597

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2020-07-31

    (49 days)

    Product Code
    Regulation Number
    892.1560
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K140666

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Liver Incytes System is intended to provide estimates of tissue stiffness generated from shear wave speed measurements (40-70 Hz) and coefficient of attenuation. The device is indicated to non-invasively determine liver tissue stiffness and attenuation. These are meant to be used in conjunction with other clinical indicators in order to assist in clinical management of patients with liver disease.

    Device Description

    Liver Incytes is a non-invasive ultrasound based device for measuring tissues stiffness and ultrasound attenuation in patients with chronic liver disease. The device uses ultrasound measurements of shear wave speed in the tissues to estimate stiffness. The attenuation is measured through the ultrasound signal itself.

    The device is designed to be used at the point of care, in clinics and hospitals. The device is used by a medical profession, an employee of the clinic/hospital. The activation unit is placed under the patient, while lying supine on an exam bed. The activation unit vibrates causing shear waves within the liver of the patient. The ultrasound transducer is placed on the patient's skin, over the intercostal space, and is used to take volumetric scans of the liver while shear waves are occurring. From the scan data, the device calculates tissue stiffness and attenuation.

    AI/ML Overview

    The provided text describes the regulatory clearance of the Sonic Incytes Liver Incytes, Model 1005 device. However, it does not contain specific details about a clinical study involving human patients to prove the device meets acceptance criteria for accuracy and performance for tissue stiffness and attenuation measurements.

    The document primarily focuses on:

    • Regulatory Clearance: FDA 510(k) clearance process.
    • Device Description: What the Liver Incytes system is, how it works, and its intended use.
    • Predicate Device: Comparison to the EchoSens FibroScan® for substantial equivalence.
    • Non-Clinical Testing: Mentions electrical safety, electromagnetic interference, ultrasound, and phantom testing for accuracy and precision. It also mentions a "small cohort of healthy volunteers" for a usability study related to BMI, not for clinical performance against a ground truth.
    • Standards Compliance: Lists various recognized consensus standards the device complies with.

    Therefore, based only on the provided text, I cannot answer the questions directly related to a clinical study proving detailed performance against acceptance criteria in human subjects. The text explicitly states that only "non-clinical testing" was performed, which included phantom testing and a usability study on healthy volunteers.

    Below, I will indicate where the information would typically be found in a complete study report and what is missing from this document.


    Based on the provided text, the specific details for a clinical study with acceptance criteria and performance data are NOT available. The document focuses on non-clinical testing and substantial equivalence to a predicate device.

    However, I can extract what is mentioned regarding testing and what would be required for the requested information:

    Missing Information/Gaps from the Provided Text:

    • Clinical Study for Performance: The text explicitly mentions "non-clinical testing" and a "usability study" on healthy volunteers. It does not describe a clinical performance study using patient data with established liver disease to validate the accuracy of tissue stiffness and attenuation measurements against a clinical ground truth.
    • Specific Acceptance Criteria (for clinical performance): While general statements about accuracy and precision are made for phantom testing, no quantitative acceptance criteria for clinical performance (e.g., minimum sensitivity/specificity for liver fibrosis staging) are provided.
    • Device Performance (Clinical): No specific metrics (e.g., AUC, sensitivity, specificity, accuracy, error margins) for how the device performed on human liver tissue stiffness and attenuation measurements are reported.
    • Test Set Details: No information regarding a clinical test set (sample size, data provenance, ground truth establishment, adjudication) is provided.
    • Training Set Details: No information regarding a training set for an AI/algorithm (if applicable, though this device seems to be a physical measurement system rather than a deep learning AI) is provided.
    • MRMC Study: No mention of a multi-reader, multi-case study.
    • Standalone Performance: No specific standalone performance metrics for the device on clinical data.

    What is available in the provided document:

    1. A table of acceptance criteria and the reported device performance (for non-clinical/phantom testing):

    • Acceptance Criteria: Not explicitly stated as quantitative thresholds for clinical performance. For non-clinical tests, it states "The accuracy and precision of the device was tested and documented based on tests performed on phantoms with known elasticity and attenuation." This implies the acceptance criteria were that the device measurements on phantoms should align with the known values, but specific quantitative criteria are not given.
    • Reported Device Performance: "The accuracy and precision of the device were found to be substantially equivalent to those of the predicate device and reference device (MRI Elastography)." No numerical performance metrics (e.g., mean absolute error, correlation coefficient, limits of agreement) are provided for either phantom or human studies. The human study mentioned was a "usability study" on healthy volunteers, not a performance study for liver stiffness/attenuation.

    2. Sample size used for the test set and the data provenance:

    • Test Set Sample Size:
      • For phantom testing: Not specified, but likely refers to a set of phantoms.
      • For human usability study: "a small cohort of healthy volunteers." The exact number is not provided, but it's explicitly for "usability" and "Body Mass Index from 25 to 43 kg/m2," not for clinical performance demonstration.
    • Data Provenance: Not explicitly stated for any clinical performance data, as none are presented. The submitter is based in Vancouver, BC, Canada, but the location of any hypothetical clinical data collection is not mentioned. The usability study was on "healthy volunteers."
    • Retrospective or Prospective: Not indicated, as no clinical performance study data is described.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

    • Not applicable/Not provided because no clinical performance test set with expert-established ground truth is described. For phantom testing, the ground truth is the "known elasticity and attenuation" of the phantoms.

    4. Adjudication method for the test set:

    • Not applicable/Not provided as no clinical test set requiring human adjudication is detailed.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    • No, not mentioned. This document does not describe an AI-assisted interpretation system or a comparative effectiveness study involving human readers. The device measures physical properties (shear wave speed and attenuation).

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

    • Yes, implicitly. The device itself provides the measurements. The performance "was tested and documented based on tests performed on phantoms." This would be a standalone performance, but the metrics are not provided in the document. No specific "algorithm only" performance for diagnosis from images is described; rather, the device directly outputs physical measurements.

    7. The type of ground truth used:

    • For non-clinical testing: "phantoms with known elasticity and attenuation."
    • For a clinical performance study (which is not detailed here), common ground truths for liver stiffness could include liver biopsy (histopathology) or MRI Elastography (as referenced for substantial equivalence).

    8. The sample size for the training set:

    • Not applicable/Not provided. This document does not describe a machine learning algorithm that requires a training set for diagnostic tasks. The device measures physical properties.

    9. How the ground truth for the training set was established:

    • Not applicable/Not provided. As above, no machine learning training set is mentioned.

    In summary, the provided FDA clearance letter and summary primarily address regulatory compliance and non-clinical testing for equivalence. It does not delve into the detailed results of a clinical performance study to establish specific acceptance criteria and device performance on human subjects for its intended diagnostic use.

    Ask a Question

    Ask a specific question about this device

    K Number
    K173079

    Validate with FDA (Live)

    Date Cleared
    2018-04-04

    (187 days)

    Product Code
    Regulation Number
    892.1000
    Age Range
    All
    Predicate For
    Why did this record match?
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    This system is a Magnetic Resonance Medicated for use as a diagnostic device. The system can produce cross-sectional images spectra in any orientation of the internal structure of the head, body or extremities.

    Magnetic Resonance images represent the spatial distribution of protons or other nuclei with spin. Image appearance is determined by many different physical properties of the tissue and the MR scan technique applied. The image acquisition process can be synchronized with the patient's breathing or cardiac cycle. The systems can use combinations of images to produce physical parameters, and related derived images.

    Images, spectra, and measurements of physical parameters, when interpreted by a trained physician, provide information that may assist the diagnosis and therapy planning. The accuracy of determined physical parameters depends on system and scan parameters, and must be controlled and validated by the clinical user. The use of contrast agents for diagnostic imaging applications should be performed consistent with the approved labeling for the contrast agent.

    In addition the Philips MR systems provide imaging capabilities, such as MR fluoroscopy, to guide and evaluate interventional and minimally invasive procedures in the head, body and extremities.

    MR Interventional procedures, performed inside or adjacent to the Philips MR system, must be performed with MR Conditional or MR Safe instrumentation as selected and evaluated by the clinical user for use with the specific MR system configuration in the hospital. The appropriateness and use of information from a Philips MR system for a specific interventional procedure and specific MR system configuration must be validated by the clinical user.

    Device Description

    The proposed Ingenia 1.5T, Ingenia 1.5T S, Ingenia 1.5T CX, Ingenia 3.0T, and Ingenia 3.0T CX R5.4 with Compressed SENSE feature is applicable for the 60 cm (CX) and 70 cm magnet systems. The systems and control software are substantially equivalent to the legally marketed primary predicate device Ingenia 1.5T, Ingenia 1.5T S and Ingenia 3T R5.3 (K163116, 01/06/2017).

    The proposed Ingenia 1.5T, Ingenia 1.5T S, Ingenia 1.5T CX, Ingenia 3.0T, and Ingenia 3.0T CX R5.4 with the Compressed SENSE feature also includes minor software changes since the clearance of the legally marketed primary predicate device, Ingenia 1.5T, Ingenia 1.5T S and Ingenia 3T R5.3 (K163116, 01/06/2017).

    The following modifications are covered in this submission:

    1. Upgrade software platform to Windows 10
    2. Compressed SENSE feature allows ultra-high acceleration factors for shorter scan times and higher resolution in 2D and 3D imaging based on the principle of Compressed sensing in combination with SENSE.
    3. PerformanceBridge Protocol Manager Release 1.0 offering intended to help customers increase collaboration within a healthcare facility group. Customers will enter the Protocol Manager cloud functionality via the PerformanceBridge portal. Protocol Manager is a subscription service to a cloud based protocol repository that will allow a user to standardize protocols over the various connected MRI systems, enable editing of protocols and scan parameters and make central protocols available for use on local MRI systems.

    The proposed Ingenia 1.5T, Ingenia 1.5T S and Ingenia 3.0T, Ingenia 1.5T CX, and Ingenia 3.0T CX R5.4 with Compressed SENSE feature is intended to be marketed with the following pulse sequences and coils that were previously cleared by FDA:

    1. mDIXON K102344
    2. SWIp K131241
    3. mDIXON-Quant K133526
    4. MRE K140666
    5. mDIXON XD K143128
    6. O-MAR K143253
    7. MultiBand SENSE K143606
    8. Ingenia Coils See Appendix 004 and Appendix 007
    AI/ML Overview

    The Philips Ingenia 1.5T, Ingenia 1.5T S, Ingenia 1.5T CX, Ingenia 3.0T, and Ingenia 3.0T CX R5.4 with the Compressed SENSE feature did not involve an AI algorithm in the typical sense of machine learning for diagnosis or prediction. Instead, "Compressed SENSE" refers to an image acquisition and reconstruction technique for Magnetic Resonance Imaging (MRI) that uses compressed sensing principles to achieve faster scan times and/or higher resolution. Therefore, the device's performance acceptance criteria and study design are related to image quality and system functionality rather than AI diagnostic performance.

    Here's an analysis of the provided information based on your request, with the understanding that the "device" in question is an MRI system with an advanced imaging feature:

    Acceptance Criteria and Reported Device Performance

    The document does not explicitly present a table of numerical acceptance criteria for a "device performance" in terms of diagnostic accuracy, sensitivity, or specificity, as would be expected for an AI-powered diagnostic tool. Instead, the acceptance criteria are generally stated as compliance with regulatory standards and the demonstration of substantial equivalence to a predicate device. The performance is assessed based on a comparison of images produced by the new feature to those from the predicate device and established imaging principles.

    Acceptance Criteria CategoryReported Device Performance
    Regulatory ComplianceComplies with IEC60601-1-2 Edition 3, IEC60601-1-6 Edition 3, IEC62366 (2015), IEC60601-1-8 Edition 2, IEC60601-2-33 Edition 3, IEC 62304 (2006), ISO 14971 (2007), Device specific guidance document ("Guidance for the Submission Of Premarket Notifications for Magnetic Resonance Diagnostic Devices – November 18, 2016"), "Guidance for the Content of Premarket Submissions for Software Contained in Medical Devices" (May 11, 2005), "Applying Human Factors and Usability Engineering to Medical Devices" (February 3, 2016), and "Content of Premarket Submissions for Management of Cybersecurity in Medical Devices" (October 2, 2014).
    Functional EquivalenceThe new device with Compressed SENSE feature is substantially equivalent to the legally marketed primary predicate device Ingenia 1.5T, Ingenia 1.5T S and Ingenia 3T R5.3 (K163116, 01/06/2017) in terms of design features, fundamental scientific technology, indications for use, and safety and effectiveness.
    Intended Use AdequacyThe verification and validation test results, combined with sample clinical images, demonstrate that the proposed device: "Meets the acceptance criteria and is adequate for its intended use." This intended use is: "a Magnetic Resonance Medical Electrical System indicated for use as a diagnostic device. The system can produce cross-sectional images, spectroscopic images and/or spectra in any orientation of the internal structure of the head, body or extremities. Images, spectra, and measurements of physical parameters, when interpreted by a trained physician, provide information that may assist the diagnosis and therapy planning." Compressed SENSE enables scan time reduction or improved spatial resolution.
    Safety and EffectivenessThe device does not raise "different questions of safety and effectiveness" compared to the predicate device. Non-clinical performance (verification and validation) tests demonstrated compliance with requirements.

    Study Details:

    1. Sample size used for the test set and the data provenance:

      • The document states that "sample clinical images" were used. However, it does not specify a numerical sample size for a test set in the context of an analytical or clinical performance study.
      • Data provenance: Not explicitly stated, but given Philips' global operations, it's likely a combination of internal data or data from clinical sites where their systems are installed. The study is described as "non-clinical verification and or validation tests" combined with sample clinical images, suggesting a retrospective evaluation of existing images or images acquired during validation protocols.
    2. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

      • This information is not provided in the document, as the submission focuses on the technical equivalence and safety of the MRI system and its new imaging feature (Compressed SENSE), rather than a diagnostic performance study requiring expert ground truth establishing for a specific pathology. The "ground truth" for an MRI system's image reconstruction capability is typically evaluated against physical phantoms (known objects) and expert review of image quality (e.g., signal-to-noise ratio, spatial resolution, artifact levels, anatomical depiction) by MR physicists and radiologists.
    3. Adjudication method for the test set:

      • This information is not applicable/provided as there was no formal diagnostic performance study described that would require an adjudication method for ground truth establishment by multiple experts.
    4. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

      • No, an MRMC comparative effectiveness study was not done. The document explicitly states: "The proposed Ingenia 1.5T, Ingenia 1.5T S, Ingenia 1.5T CX, Ingenia 3.0T, and Ingenia 3.0T CX R5.4 with the Compressed SENSE feature did not require a clinical study since substantial equivalence to the legally marketed predicate device was proven with the verification/validation testing."
      • Furthermore, the "Compressed SENSE" feature is an imaging technique, not an AI diagnostic tool, so improving human readers with AI assistance is not the objective here. The goal is to produce images of comparable diagnostic quality with faster acquisition or higher resolution.
    5. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

      • Not applicable in the context of an AI diagnostic algorithm. The "Compressed SENSE" is an image reconstruction algorithm that operates intrinsically within the MRI system to produce images for interpretation by a human. Its performance is effectively its ability to produce diagnostically acceptable images.
    6. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

      • For the technical validation of Compressed SENSE, the "ground truth" would likely involve:
        • Physical phantoms: Objects with known properties used to objectively measure image quality metrics (e.g., spatial resolution, signal-to-noise ratio, uniformity).
        • Comparison to gold standard MRI sequences: Images acquired with conventional, fully sampled sequences (considered the "gold standard" for image quality, though slower) would serve as a reference for images reconstructed using Compressed SENSE.
        • Expert review of image quality: Radiologists and MR physicists would qualitatively assess the images for diagnostic acceptability, presence of artifacts, depiction of anatomical structures, and comparability to predicate device images.
      • The document mentions "sample clinical images" were part of the validation, implying expert review of these images for diagnostic acceptability.
    7. The sample size for the training set:

      • Not applicable/provided. Compressed SENSE, while employing sophisticated mathematics (compressed sensing), is primarily a signal processing and image reconstruction technique rather than a machine learning algorithm that requires a separate "training set" for diagnostic classification. The parameters for compressed sensing reconstruction are typically derived from theoretical principles and validated through experimentation, rather than trained from a large labeled dataset in the same way a deep learning model would be.
    8. How the ground truth for the training set was established:

      • Not applicable/provided as there was no distinct "training set" in the context of an AI diagnostic model. The development of Compressed SENSE relies on mathematical principles and engineering validation.
    Ask a Question

    Ask a specific question about this device

    K Number
    K173451

    Validate with FDA (Live)

    Date Cleared
    2018-03-20

    (134 days)

    Product Code
    Regulation Number
    892.1000
    Age Range
    All
    Predicate For
    N/A
    Why did this record match?
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    This system is a Magnetic Resonance Medical Electrical Systems indicated for use as a diagnostic device. The system can produce cross-sectional images, spectroscopic images and/or spectra in any orientation of the internal structure of the head, body or extremities.

    Magnetic Resonance images represent the spatial distribution of protons or other nuclei with spin. Image appearance is determined by many different physical properties of the tissue and the MR scan technique applied. The image acquisition process can be synchronized with the patient's breathing or cardiac cycle. The systems can use combinations of images to produce physical parameters, and related derived images.

    Images, spectra, and measurements of physical parameters, when interpreted by a trained physician, provide information that may assist the diagnosis and therapy planning. The accuracy of determined physical parameters depends on system and scan parameters, and must be controlled and validated by the clinical user. The use of contrast agents for diagnostic imaging applications should be performed consistent with the approved labeling for the contrast agent.

    In addition the Philips MR systems provide imaging capabilities, such as MR fluoroscopy, to guide and evaluate interventional and minimally invasive procedures in the head, body and extremities.

    MR Interventional procedures, performed inside or adjacent to the Philips MR system, must be performed with MR Conditional or MR Safe instrumentation as selected and evaluated by the clinical user for use with the system configuration in the hospital. The appropriateness and use of information from a Philips MR system for a specific interventional procedure and specific MR system configuration must be validated by the clinical user.

    Device Description

    The proposed Ingenia Elition S and Ingenia Elition X R5.4 with new gradient system/specifications are modifications of the 70 cm Ingenia 3.0T system, included in the legally marketed predicate device Ingenia 1.5T, Ingenia 1.5T S and Ingenia 3.0T R5.3 (K163116, 01/06/2017). The systems and control software are substantially equivalent to the legally marketed predicate device Ingenia 1.5T, Ingenia 1.5T S and Ingenia 3.0T R5.3 (K163116, 01/06/2017). Hereafter Ingenia Elition S and Ingenia Elition X R5.4 will be used to indicate the proposed device Ingenia Elition S and Ingenia Elition X R5.4 with new gradient system/specifications The proposed Ingenia Elition S and Ingenia Elition X R5.4 also includes minor software changes since the clearance of the legally marketed predicate device, Ingenia 1.5T, Ingenia 1.5T S and Ingenia 3.0T R5.3 (K163116, 01/06/2017). The following modifications are covered compared to legally marketed predicate device: 1. Upgrade of SW platform to Windows 10 and PSC 6.1 (to be compatible with Windows 10); 2. PerformanceBridge Protocol Manager Release 1.0; 3. Introduction of new gradient system hardware with new qradient specifications: 4. Introduction of new product name and covers. The proposed Ingenia Elition S and Ingenia Elition X R5.4 are intended to be marketed with the following pulse sequences and coils that were previously cleared by FDA: 1. mDIXON K102344 2. SWIp K131241 3. mDIXON-Quant K133526 4. MRE K140666 5. mDIXON XD K143128 6. O-MAR K143253 7. MultiBand SENSE K143606 8. Ingenia Coils See Appendix 004

    AI/ML Overview

    The provided text is a 510(k) summary for the Philips Ingenia Elition S and Ingenia Elition X R5.4 Magnetic Resonance Diagnostic Devices. This document does not describe acceptance criteria or a specific study proving the device meets acceptance criteria in the way typically expected for an AI/algorithm-based device's performance.

    Instead, this submission focuses on demonstrating substantial equivalence to a predicate device (Ingenia 1.5T, Ingenia 1.5T S and Ingenia 3.0T R5.3, K163116) through non-clinical performance data and compliance with recognized standards. The "acceptance criteria" referred to in the document are general statements about meeting regulatory and safety standards for an MRDD, rather than specific performance metrics (e.g., sensitivity, specificity, AUC) for an AI algorithm.

    Therefore, many sections of your requested output cannot be fulfilled from the provided text.

    Here's what can be extracted and inferred:

    1. Table of Acceptance Criteria and Reported Device Performance:

    Acceptance Criteria (General)Reported Device Performance
    Compliance with international and FDA-recognized consensus standards (e.g., IEC, NEMA, ISO)The device complies with the listed standards.
    Meets acceptance criteria and is adequate for its intended useNon-Clinical verification and validation tests demonstrate that the device meets acceptance criteria and is adequate for its intended use.
    Substantial equivalence to predicate device in terms of safety and effectivenessDemonstrated through non-clinical performance (verification and validation) tests.

    2. Sample Size Used for the Test Set and Data Provenance:

    • Not Applicable. The document explicitly states: "The proposed Ingenia Elition S and Ingenia Elition X R5.4 did not require a clinical study since substantial equivalence to the legally marketed predicate device was proven with the verification/validation testing."
    • The "test set" in this context refers to non-clinical verification and validation tests, not a dataset of patient images for an algorithm's performance evaluation. No information on sample size or data provenance (country of origin, retrospective/prospective) for such tests is provided.

    3. Number of Experts Used to Establish Ground Truth and Qualifications:

    • Not Applicable. As no clinical study was performed for AI algorithm performance, there's no mention of experts establishing a ground truth for a test set.

    4. Adjudication Method for the Test Set:

    • Not Applicable. No clinical study or performance evaluation with a test set requiring adjudication is described.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done:

    • No. The document explicitly states no clinical study was required. Therefore, an MRMC study was not performed.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done:

    • Not Applicable. This submission is for an MRI system, not a standalone AI algorithm. The performance evaluation focuses on the safety and effectiveness of the MRI system, not an AI component's standalone diagnostic capabilities.

    7. The Type of Ground Truth Used:

    • Not Applicable. For the non-clinical verification and validation tests, the "ground truth" would be established by engineering specifications, regulatory standards, and expected physical performance parameters of the MRI system, rather than expert consensus, pathology, or outcomes data related to an algorithm's diagnostic output. The document doesn't detail the specifics of these non-clinical ground truths.

    8. The Sample Size for the Training Set:

    • Not Applicable. This is not a submission for an AI/ML algorithm that requires a training set. The "software changes" mentioned are minor updates to the operating system and existing functionalities, not the development of a new AI model requiring training data.

    9. How the Ground Truth for the Training Set Was Established:

    • Not Applicable. No AI/ML algorithm requiring a training set is described.

    In summary:

    This 510(k) submission primarily details the device (an MRI system) modifications and demonstrates substantial equivalence to a previously cleared predicate device through compliance with various non-clinical standards and tests. It does not involve the evaluation of an AI algorithm's diagnostic performance against specific acceptance criteria using patient data, and thus, many of the requested details are not present in this type of regulatory filing.

    Ask a Question

    Ask a specific question about this device

    K Number
    K173356

    Validate with FDA (Live)

    Date Cleared
    2018-03-06

    (132 days)

    Product Code
    Regulation Number
    892.1000
    Age Range
    All
    Predicate For
    N/A
    Why did this record match?
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    This system is a Magnetic Resonance Medical Electrical Systems indicated for use as a diagnostic device. The system can produce cross-sectional images, spectroscopic images and/or spectra in any orientation of the internal structure of the head, body or extremities.

    Magnetic Resonance images represent the spatial distribution of protons or other nuclei with spin. Image appearance is determined by many different physical properties of the tissue and the anatomy, and the MR scan technique applied. The image acquisition process can be synchronized with the patient's breathing or cardiac cycle. The systems can use combinations of images to produce physical parameters, and related derived images.

    Images, spectra, and measurements of physical parameters, when interpreted by a trained physician, provide information that may assist the diagnosis and therapy planning. The accuracy of determined physical parameters depends on system and scan parameters, and must be controlled and validated by the clinical user. The use of contrast agents for diagnostic imaging applications should be performed consistent with the approved labeling for the contrast agent.

    In addition the Philips MR systems provide imaging capabilities, such as MR fluoroscopy, to guide and evaluate interventional and minimally invasive procedures in the head, body and extremities.

    MR Interventional procedures, performed inside or adjacent to the Philips MR system, must be performed with MR Conditional or MR Safe instrumentation as selected and evaluated by the clinical user for use with the specific MR system configuration in the hospital. The appropriateness and use of information from a Philips MR system for a specific interventional procedure and specific MR system configuration must be validated by the clinical user.

    Device Description

    The proposed Ingenia Elition S and Ingenia Elition X R5.4 with new gradient system/specifications are modifications of the 70 cm Ingenia 3.0T system, included in the legally marketed predicate device Ingenia 1.5T, Ingenia 1.5T S and Ingenia 3.0T R5.3 (K163116, 01/06/2017).

    The systems and control software are substantially equivalent to the legally marketed predicate device Ingenia 1.5T, Ingenia 1.5T S and Ingenia 3.0T R5.3 (K163116, 01/06/2017).

    Hereafter Ingenia Elition S and Ingenia Elition X R5.4 will be used to indicate the proposed device Ingenia Elition S and Ingenia Elition X R5.4 with new gradient system/specifications

    The proposed Ingenia Elition S and Ingenia Elition X R5.4 also includes minor software changes since the clearance of the legally marketed predicate device, Ingenia 1.5T, Ingenia 1.5T S and Ingenia 3.0T R5.3 (K163116, 01/06/2017).

    The following modifications are covered compared to legally marketed predicate device:

    1. Upgrade of SW platform to Windows 10 and PSC 6.1 (to be compatible with Windows 10);
    2. PerformanceBridge Protocol Manager Release 1.0;
    3. Introduction of new gradient system hardware with new gradient specifications;
    4. Introduction of new product name and covers.

    The proposed Ingenia Elition S and Ingenia Elition X R5.4 are intended to be marketed with the following pulse sequences and coils that were previously cleared by FDA:

    1. mDIXON K102344
    2. SWIp K131241
    3. mDIXON-Quant K133526
    4. MRE K140666
    5. mDIXON XD K143128
    6. O-MAR K143253
    7. MultiBand SENSE K143606
    AI/ML Overview

    This document describes the 510(k) summary for the Philips Ingenia Elition S and Ingenia Elition X R5.4 Magnetic Resonance Diagnostic Devices. The submission focuses on demonstrating substantial equivalence to a predicate device (Ingenia 1.5T, Ingenia 1.5T S and Ingenia 3.0T R5.3, K163116) rather than proving performance based on specific clinical outcomes for a novel application. Therefore, the details requested in the prompt, which are typically associated with performance studies for AI/CADe devices, are largely not present in this type of submission.

    Based on the provided text, here's what can be extracted:

    • Device: Ingenia Elition S and Ingenia Elition X R5.4 (Magnetic Resonance Diagnostic Device - MRDD)
    • Submission Type: 510(k) Premarket Notification, Abbreviated 510(k)
    • Purpose of Submission: To demonstrate substantial equivalence to a legally marketed predicate device due to modifications (new gradient system/specifications, software upgrades like Windows 10 compatibility and PerformanceBridge Protocol Manager, new product name/covers).

    Here's an analysis of the provided text in relation to your specific questions:

    1. A table of acceptance criteria and the reported device performance

    The document states: "The verification and/or validation test results demonstrate that the proposed Ingenia Elition S and Ingenia Elition X R5.4: • Complies with the aforementioned international and FDA recognized consensus standards and Device specific guidance document, entitled "Guidance for the Submission Of Premarket Notifications for Magnetic Resonance Diagnostic Devices - November 18, 2016" • Meets the acceptance criteria and is adequate for its intended use."

    It further concludes: "The results of these tests demonstrate that the proposed Ingenia Elition S and Ingenia Elition X R5.4 meet the acceptance criteria and is adequate for its intended use."

    However, the specific "acceptance criteria" (e.g., in terms of image quality metrics, diagnostic accuracy, or specific performance thresholds) and the "reported device performance" against those criteria are not detailed in this 510(k) summary. This type of submission relies on demonstrating compliance with recognized standards and that the modifications do not raise new questions of safety or effectiveness compared to the predicate device. The performance is implied to be equivalent to the predicate, which presumptively met certain performance standards.

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    This information is not provided in the document. The submission states, "The proposed Ingenia Elition S and Ingenia Elition X R5.4 did not require a clinical study since substantial equivalence to the legally marketed predicate device was proven with the verification/validation testing." This indicates that formal clinical studies with distinct test sets, common for AI/CADe devices, were not performed or submitted for this 510(k). The "verification/validation testing" likely refers to engineering, phantom, and perhaps limited clinical image quality checks, rather than a full-scale clinical trial.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    This information is not provided. As no clinical study needing ground truth establishment was conducted for this 510(k) submission, there's no mention of experts or their qualifications for establishing ground truth on a test set.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    This information is not provided. As no clinical study needing a test set with ground truth was conducted for this 510(k) submission, there's no mention of an adjudication method.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    No MRMC comparative effectiveness study was done as part of this submission. This device is a Magnetic Resonance Diagnostic Device (an MRI scanner itself), not an AI/CADe algorithm designed to assist human readers. The clearance is for the hardware and basic software functionality rather than an AI-driven interpretive aid.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    This question is not directly applicable. This is an MRI device, not a standalone algorithm. The "performance" relates to its ability to acquire images, not to automatically interpret them.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    This information is not provided. Given that no clinical study was performed for this 510(k) submission (as stated: "The proposed Ingenia Elition S and Ingenia Elition X R5.4 did not require a clinical study..."), the concept of ground truth for a clinical validation set is not applicable here. The "ground truth" for the performance of an MR system typically relies on physical measurements in phantoms and comparison against established image quality metrics, rather than clinical outcomes or expert consensus for diagnosis.

    8. The sample size for the training set

    This information is not provided and is not relevant for this type of device submission. This is not an AI/ML device that requires a training set. The changes are hardware (gradient system) and basic software (OS upgrade, protocol manager).

    9. How the ground truth for the training set was established

    This information is not provided and is not relevant for this type of device submission, as there's no training set mentioned for an AI/ML model.


    Summary of the Study Proving Acceptance (as implied by the document):

    The "study" proving the device meets acceptance criteria was a series of non-clinical verification and validation tests. These tests were designed to demonstrate:

    • Compliance with recognized standards: IEC 60601-1 (medical electrical equipment), IEC 60601-1-2 (EMC), IEC 62366 (usability), IEC 60601-1-8 (alarms), IEC 60601-2-33 (MR specific safety), IEC 62304 (software life cycle), NEMA MS-1, MS-4, MS-8, PS 3.1-3.20 (MR performance and DICOM standards), ISO 14971 (risk management).
    • Compliance with FDA guidance documents: Specifically, "Guidance for the Submission Of Premarket Notifications for Magnetic Resonance Diagnostic Devices – November 18, 2016" and other relevant guidances for software, human factors, cybersecurity, biocompatibility, and EMC.
    • Equivalence to the predicate device: The new gradient system and software changes were evaluated to ensure they did not negatively impact the imaging performance (image quality, safety parameters) or introduce new risks compared to the predicate device.

    The document states that these tests demonstrate the device "Meets the acceptance criteria and is adequate for its intended use." The "acceptance criteria" are intrinsically tied to meeting these regulatory standards and demonstrating that the modifications do not alter the substantial equivalence to the predicate. The document does not provide quantitative performance metrics from these tests.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1