Search Filters

Search Results

Found 1 results

510(k) Data Aggregation

    K Number
    K173025

    Validate with FDA (Live)

    Date Cleared
    2018-02-08

    (133 days)

    Product Code
    Regulation Number
    888.3080
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K170962, K153105, K140162

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The NuVasive MLX - Medial Lateral Expandable Lumbar Interbody System is indicated for intervertebral body fusion of the spine in skeletally mature patients. The System is designed for use with autogenous and/or allogeneic bone graft comprised of cancellous and/or corticocancellous bone graft to facilitate fusion and supplemental internal spinal fixation systems cleared by the FDA for use in the thoracolumbar spine. The used in patients who have had at least six months of non-operative treatment.

    The NuVasive MLX- Medial Lateral Expandable Lumbar Interded for use in interded for use in interbody fusions in the thoracic spine from T1 to T12 and at the thoracolumbar junction (T12-L1), and is intended for use in the lumbar spine, from L1 to S1, for the treatment of symptomatic disc degenerative spondylolisthesis at one or two adjacent levels, including thoracic disc herniation (with myelopathy with or without axial pain). DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The NuVasive MLX- Medial Lateral Expandable Lumbar Interbody System can be used as an adjunct to fusion in patients diagnosed with multilevel degenerative scoliosis.

    The NuVasive AP Expandable XLIF System is indicated for intervertebral body fusion of the spine in skeletally mature patients. The System is designed for use with autogenous and/or allogeneic bone graft comprised of cancellous and/or corticocancellous bone graft to facilitate fusion and supplemental internal spinal fixation systems (e.g., pedicle screw/rod systems) cleared by the FDA for use in the thoracolumbar spine. The devices are to be used in patients who have had at least six months of non-operative treatment.

    The NuVasive AP Expandable XLIF System is intended for use in interbody fusions in the thoracic spine from T1 to T12 and at the thoracolumbar junction (T12-L1), and is intended for use in the lumbar spine, from L1 to S1, for the treatment of symptomatic disc degeneration (DDD) or degenerative spondylolisthesis at one or two adjacent levels, including thoracic disc herniation (with myelopathy with or without axial pain). DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The NuVasive AP Expandable XLIF System can be used as an adjunct to fusion in patients diagnosed with multilevel degenerative scollosis.

    Device Description

    The NuVasive MLX and APX Interbody Devices are manufactured from Ti-6Al-4V ELI conforming to ASTM F136 and ISO 5832-3, Ti-6A1-4V conforming to ASTM 1472, and Nitinol SE508 conforming to ASTM F2063. The implants are available in a variety of different shapes and sizes to suit the individual pathology and anatomical conditions of the patient. This scope of this 510(k) includes expanded indications for use and minor add-to-file changes.

    AI/ML Overview

    This document is a 510(k) Premarket Notification from the FDA regarding the NuVasive MLX - Medial Lateral Expandable Lumbar Interbody System and the NuVasive AP Expandable XLIF System. It determines these devices are substantially equivalent to legally marketed predicate devices.

    Here's an analysis of the provided information concerning acceptance criteria and supporting studies:

    1. Table of Acceptance Criteria and Reported Device Performance:

      The document does not provide explicit acceptance criteria or reported device performance metrics in the format of a typical performance study. Instead, it relies on demonstrating "substantial equivalence" to predicate devices. This means that if the predicate devices meet performance requirements, and the new device is sufficiently similar, it can be marketed.

      The performance data mentioned pertains to mechanical testing and bacterial endotoxin testing.

      Acceptance Criteria Category/TypeReported Device Performance/Testing
      Mechanical Performance"Mechanical performance testing data was provided as part of the previous submissions to establish substantial equivalence for their use. The previously presented mechanical testing data are sufficient to support the subject system and does not warrant the need for additional nonclinical testing." (Referencing K153105 and K140162 for specific data)
      Biocompatibility/Bacterial Endotoxin"Bacterial endotoxin testing (BET) was conducted in accordance with ANSI/AAMI ST72:2011/(R)2016." (No specific pass/fail values or results are explicitly stated in this summary, but the implication is that it passed the standard.)
    2. Sample size used for the test set and the data provenance:

      Since no new clinical or performance study was conducted for this specific 510(k) submission (K173025) beyond referencing prior submissions, there is no new test set sample size or data provenance provided in this document. The mechanical testing data relies on previous submissions (K153105 and K140162), and the bacterial endotoxin testing would typically be performed on a representative sample of manufactured devices.
      The document does not specify country of origin for any data cited from previous submissions, nor whether it was retrospective or prospective.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

      Not applicable. No new clinical or comparative performance study with an expert-established ground truth was conducted for this submission. The ground truth for interbody fusion devices in a 510(k) context often relates to demonstrating material properties, mechanical integrity, and biocompatibility, rather than diagnostic accuracy that would require expert consensus on cases.

    4. Adjudication method for the test set:

      Not applicable. No new clinical study requiring adjudication of a test set was conducted for this submission.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

      Not applicable. This device is an intervertebral body fusion device, not a diagnostic or AI-assisted imaging device. Therefore, MRMC studies are not relevant.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

      Not applicable. This device is a physical implant, not an algorithm or AI system.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

      For the mechanical and bacterial endotoxin testing, the "ground truth" would be established by:

      • Mechanical Testing: Adherence to established engineering and biomechanical standards (e.g., ISO, ASTM) for strength, durability, and fatigue life of interbody fusion devices. The ground truth is the device's ability to withstand physiological loads and maintain structural integrity.
      • Bacterial Endotoxin Testing: Compliance with the ANSI/AAMI ST72:2011/(R)2016 standard, which sets limits for endotoxin levels to ensure the device is not pyrogenic.
    8. The sample size for the training set:

      Not applicable. This is not an AI/ML device requiring a training set.

    9. How the ground truth for the training set was established:

      Not applicable. This is not an AI/ML device requiring ground truth for a training set.

    In summary:

    This 510(k) notification for the NuVasive MLX and APX systems relies on demonstrating substantial equivalence to previously cleared devices rather than providing a new, comprehensive performance study with explicit acceptance criteria and device performance results. The core of the evidence lies in the technological characteristics, materials, and intended use being similar to existing, legally marketed devices, and referencing prior mechanical test data and current bacterial endotoxin testing to support safety and effectiveness.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1