    Reference Devices :

    K122771, K133218, K073351, K133218, K142264, K133653

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Vertu® & Vertu® Ti-Bond devices are stand-alone interbody fusion devices intended for spinal fusion procedures at one level from the C2/C3 disc space to the C7/T disc space in skeletally mature patients with degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radies) of the cervical spine. Implanted via an open, anterior approach and packed with autograft or allogenic bone graft comprised of cancellous and/or corticocancellous bone graft.

    Patients must have undergone a regimen of at least six (6) weeks non-operative treatment prior to being treated with these devices.

    The implant is designed to accommodate two screws. Two screws should be used to ensure adequate fixation of the implant.

    Crystal® & Crystal® Ti-Bond devices are intended for spinal fusion at one or two contiguous levels in skeletally mature patients with degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies) of the cervical spine. Implanted via an open, anterior approach from the C2-C3 disc space to the C7-T1 disc space and packed with autograft or allogenic bone graft comprised of cancellous and/or corticocancellous bone graft.

    The device is intended to be used with supplemental fixation systems that have been cleared for use in the cervical spine (i.e., anterior plate systems).

    Patients must have undergone a regimen of at least six (6) weeks non-operative treatment prior to being treated with these devices.

    Device Description

    The Vertu and Vertu Ti-Bond Cervical Interbody System is composed of an implant body made from titanium alloy (Ti-6Al-4V) conforming to ASTM F136 or ISO 5832-3 or polyetheretherketone (PEEK-Optima®) conforming to ASTM F2026 or PEEK-Optima® coated with commercially pure titanium per ASTM F1580 and fixation screws made from Ti-6Al-4V per ASTM F136 or ISO 5832-3 with a Nitinol clip conforming to ASTM F2063. All implant bodies have a titanium insert lining the internal surface of the screw holes conforming to ASTM F136 or ISO 5832-3. The implant body is generally boxshaped device with holes through its body for the placement of graft material. Additionally, it has teeth located on its superior and inferior external surfaces to help keep the device from migrating once placed in its desired location. Each screw hole is lined in its internal surface with a titanium ring insert. Screws pass through screw holes of the implant body and affix to bone to help prevent implant migration. When fully seated, the screw head rests on the titanium insert of the screw hole.

    The Crystal and Crystal Ti-Bond Cervical Interbody devices are generally a box-shaped device with various holes located throughout its geometry to allow for packing of bone graft material. The body of the implant is made from titanium alloy (Ti-6A1-4V) conforming to ASTM F136 or ISO 5832-3 or polyetheretherketone (PEEK-Optima®) conforming to ASTM F2026 or PEEK-Optima® coated with commercially pure titanium per ASTM F1580. Superior and inferior surfaces of the device have teeth that help keep the device from migrating once placed in its desired location.

    AI/ML Overview

    This FDA 510(k) Premarket Notification document (K153352) describes the Vertu® & Vertu® Ti-Bond and Crystal® & Crystal® Ti-Bond Cervical Interbody Systems. Per the document, "No changes were made to the existing Vertu. Vertu Ti-Bond. Crystal Ti-Bond devices nor were any new components added to the system. Therefore, no additional testing was required or performed." This implies that new acceptance criteria and a study to prove these devices meet those criteria were not established for this specific submission. Instead, the document relies on the substantial equivalence to previously cleared predicate devices.

    Therefore, the following information cannot be directly extracted from the provided text for this specific K153352 submission:

    1. A table of acceptance criteria and the reported device performance: Not explicitly stated as new criteria or performance data were generated for this submission. The device is determined to be substantially equivalent based on existing data and characteristics of predicate devices.
    2. Sample size used for the test set and the data provenance: Not applicable as a new test set was not created for this submission. The submission references previous clearances (K122771, K133218, K073351) for the predicate devices, which would have had their own testing.
    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts: Not applicable.
    4. Adjudication method for the test set: Not applicable.
    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance: Not applicable. These are interbody fusion devices, not AI-assisted diagnostic tools.
    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done: Not applicable.
    7. The type of ground truth used: Not applicable.
    8. The sample size for the training set: Not applicable.
    9. How the ground truth for the training set was established: Not applicable.

    Summary based on the provided document:

    The provided document (K153352) is a 510(k) premarket notification for expanded indications for the Vertu® & Vertu® Ti-Bond and Crystal® & Crystal® Ti-Bond Cervical Interbody Systems. The FDA determined the device is substantially equivalent to legally marketed predicate devices. The basis for this determination is that no changes were made to the existing devices, and no new components were added, thus no additional testing was required or performed for this specific submission. The substantial equivalence is argued based on a comparison of indications for use, technological characteristics, surgical technique, design features, and instrumentation to established predicate devices.

    The acceptance criteria and performance data for the original clearances of these devices and their predicates would be found in the associated 510(k) submissions (K122771, K133218, K073351, K150053, K142264, K133653), which are not included in this document.

    Ask a Question

    Ask a specific question about this device

    K Number
    K133218

    Validate with FDA (Live)

    Date Cleared
    2014-12-10

    (418 days)

    Product Code
    Regulation Number
    888.3080
    Age Range
    All
    Reference & Predicate Devices
    Why did this record match?
    Reference Devices :

    K112036, K073351, K071833, K122771

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Crystal®:
    The Crystal® device is intended for spinal fusion procedures at one level (C3-C7) in skeletally mature patients with degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies) of the cervical spine. Implanted via an open, anterior approach and packed with autogenous bone.

    The Crystal® device is intended to be used with supplemental spinal fixation systems that have been cleared for use in the cervical spine (i.e., anterior plate systems).

    Patients must have undergone a regimen of at least six (6) weeks non-operative treatment prior to being treated with these devices.

    Mosaic®:
    The Mosaic® device is an interbody fusion device intended for spinal fusion procedures at one level (C3-C7) in sketally mature patients with degenerative disc disease (defined as neck pain with degeneration of the disc confirmed by history and radiographic studies) of the cervical spine. Implants are to be implanted via an open, anterior approach and packed with autogenous bone.

    Patients must have undergone a regimen of at least six (6) weeks non-operative treatment prior to being treated with these devices.

    The implant is designed to accommodate two, three, or four screws. The maximum number of screws should be used to ensure adequate fixation of the implant.

    Vertu®:
    The Vertu® device is a stand-alone interbody fusion device intended for spinal fusion procedures at one level ( C3-C7) in skeletally mature patients with degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies) of the cervical spine. Implanted via an open, anterior approach and packed with autogenous bone.

    Patients must have undergone a regimen of at least six (6) weeks non-operative treatment prior to being treated with these devices.

    The implant is designed to accommodate two screws. Two screws should be used to ensure adequate fixation of the implant.

    Device Description

    Crystal:
    Crystal is an intervertebral body fusion device for use in cervical spinal surgery. The device is generally box-shaped with various holes throughout its geometry to allow for the placement of autograft. The exterior of the device has "teeth" or other generally sharp engagement members on the superior and inferior surfaces to help prevent the device from migrating once it is surgically positioned.

    Mosaic:
    The Mosaic Spinal Implant System is composed of a device body and fixation screws. The body is a generally box-shaped device with various holes located throughout its geometry for the placement of graft material. Additionally, it has teeth on its superior and inferior external surfaces to keep the device from migrating once placed in its desired location. The box-shaped body has projections (or flanges) that encompass screw holes. Screws pass through screw holes and affix to bone to help prevent implant migration.

    Vertu:
    The Vertu Cervical Intervertebral Body Fusion System is composed of an implant body and fixation screws. The implant body is a generally box-shaped device with holes through its body for the placement of graft material. Additionally, it has teeth located on its superior and inferior external surfaces to help keep the device from migrating once placed in its desired location. There are also screw holes located in the implant body. Screws pass through screw holes of the implant body and affix to bone to help prevent implant migration.

    AI/ML Overview

    Here's a breakdown of the acceptance criteria and study information for the Crystal®, Mosaic®, and Vertu® intervertebral body fusion devices, based on the provided FDA 510(k) summary:

    The provided document is a 510(k) summary, which focuses on demonstrating substantial equivalence to a predicate device rather than presenting a performance study with acceptance criteria in the same way a de novo or PMA application might. Therefore, the "acceptance criteria" here are essentially the performance metrics of the legally marketed predicate devices, and the "study" is the non-clinical testing performed to show equivalence.


    1. Table of Acceptance Criteria and Reported Device Performance

    Given that this is a 510(k) for substantial equivalence, the "acceptance criteria" are implied to be the performance of the predicate devices. The "reported device performance" demonstrates that the subject devices perform comparably to these predicates.

    Test TypeAcceptance Criteria (Implied by Predicate)Reported Device Performance
    Material BiocompatibilityBiocompatibility in accordance with FDA Memorandum #G95-1 and ISO 10993-1 Part 1 for PEEK (Invibio MAF 1209) and commercially pure titanium (ASTM F 1580).The PEEK material's biocompatibility is presented in Invibio device master file (MAF 1209). The titanium coating material is commercially pure titanium, in accordance with ASTM F 1580. No further testing required.
    Dynamic Torsion TestingPerformance comparable to the predicate devices (Crystal®, Mosaic®, Vertu® Systems - K073351, K071833, K122771, and Calix PC - K112036).Tested in accordance with ASTM F2077-03. Results used to support substantial equivalence.
    Gravimetric Measurement for Wear AssessmentPerformance comparable to the predicate devices.Tested in accordance with ASTM F2025-06. Results used to support substantial equivalence.
    Particle CharacterizationPerformance comparable to the predicate devices, specifically the wear debris data of predicate Calix PC (K112036).Tested in accordance with ASTM F1877-89. Wear debris data (number of particulates and size) indicates the device coating performs similarly to predicate Calix PC (K112036).
    Static ShearPerformance comparable to the predicate devices.Tested in accordance with ASTM F1044-05. Results used to support substantial equivalence.
    Static TensionPerformance comparable to the predicate devices.Tested in accordance with ASTM F1147-05. Results used to support substantial equivalence.
    Abrasion ResistancePerformance comparable to the predicate devices.Tested in accordance with ASTM F1978-00. Results used to support substantial equivalence.

    2. Sample Size Used for the Test Set and Data Provenance

    The document does not explicitly state the sample sizes (e.g., number of units tested) for each mechanical test. The data provenance is derived from non-clinical bench testing conducted to support the substantial equivalence claim. There is no mention of country of origin for this testing, but it is typically conducted by the manufacturer or a contract research organization.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts

    Not applicable. This submission relies on non-clinical bench testing and comparison to predicate device performance, not on expert-established ground truth from clinical data.

    4. Adjudication Method for the Test Set

    Not applicable for non-clinical bench testing focused on mechanical properties.

    5. If a Multi-reader Multi-case (MRMC) Comparative Effectiveness Study was done

    No, an MRMC comparative effectiveness study was not done. The submission explicitly states: "Clinical Studies No clinical studies were performed."

    6. If a Standalone (i.e. algorithm only without human-in-the-loop performance) was done

    This is not applicable as the device (intervertebral body fusion device) is a physical implant, not a software algorithm. The document explicitly states: "Software Verification and Validation Testing The device does not contain software. Therefore no software verification and validation testing were performed."

    7. The Type of Ground Truth Used

    The ground truth used is based on the established performance characteristics and safety profile of the predicate devices and recognized consensus standards (e.g., ASTM, ISO) for material and mechanical testing. For the wear debris, the ground truth for comparison was specifically the predicate Calix PC (K112036).

    8. The Sample Size for the Training Set

    Not applicable. As a physical medical device, there is no "training set" in the context of machine learning or AI.

    9. How the Ground Truth for the Training Set Was Established

    Not applicable. There is no training set.