Found 2 results

510(k) Data Aggregation

    K Number
    DEN210034

    Validate with FDA (Live)

    Device Name
    ONE Male Condom
    Date Cleared
    2022-02-23

    (181 days)

    Product Code
    Regulation Number
    884.5305
    Type
    Direct
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K081886, K122219, K141059, K150072

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The ONE Male Condom is used for contraception to help reduce the risk of pregnancy during vaginal intercourse and for prophylactic purposes to help reduce the transmission of sexually transmitted infections (STIs) during vaginal or anal intercourse. The ONE Male Condom should be used with a condom compatible lubricant when used for anal intercourse.

    Device Description

    The ONE Male Condom is a natural rubber latex sheath that completely covers the penis. The condom is straight walled with a reservoir tip and is silicone lubricated. The ONE Male Condom is available in 56 sizes and consists of three different condom types, standard, thin, and fitted.

    AI/ML Overview

    This document provides information about the acceptance criteria and supporting studies for the ONE Male Condom.

    1. Table of Acceptance Criteria and Reported Device Performance

    The acceptance criteria for the ONE Male Condom are based on various performance aspects, primarily referencing ISO 4074-15 and ASTM D3492-16. The reported device performance consistently met these criteria.

    Acceptance Criteria CategorySpecific CriteriaReported Device Performance
    BiocompatibilityCytotoxicity (MEM Elution Test per ISO 10993-5:2009)Biocompatible (leveraged from previously cleared identical condoms).
    Sensitization (Guinea Pig Maximization per ISO 10993-10:2010)Biocompatible (leveraged from previously cleared identical condoms).
    Irritation (Vaginal Irritation Test per ISO 10993-10:2010)Biocompatible (leveraged from previously cleared identical condoms).
    Acute Systemic Toxicity (ISO 10993-11:2006)Biocompatible (leveraged from previously cleared identical condoms).
    Shelf-LifeFive-year shelf-life demonstrated through accelerated aging studies (7 days at 70°C and 90 days at 50°C), with subsequent dimensional analysis, airburst testing, freedom from holes, visible defects, and package integrity (per ISO 4074-15 and ASTM D3492-16).Met acceptance criteria for all tests after accelerated aging, demonstrating acceptable package integrity and functional performance over five years.
    Bench PerformanceDimensional Analysis: Nominal width, length, and thickness consistent with specifications.Met all specifications for dimensional analysis across three lots of each proposed size.
    Water Leak Testing: Freedom from holes (per ISO 4074-15 and ASTM D3492-16) with an Acceptance Quality Limit (AQL) consistent with lot size.Met all specifications for freedom from holes across three lots of each proposed size.
    Airburst Testing (Pressure): Minimum of 1 kPa (per ISO 4074-15 and ASTM D3492-16).Met all specifications for airburst pressure across three lots of each proposed size.
    Airburst Testing (Volume): Ranged from 11-22 dm³ based on condom size (per ISO 4074-15 and ASTM D3492-16).Met all specifications for airburst volume across three lots of each proposed size.
    Visible Defects: (per ISO 4074-15 and ASTM D3492-16) with an AQL consistent with lot size.Met all specifications for visible defects across three lots of each proposed size.
    Clinical PerformanceTotal Clinical Failure Rate (Anal Intercourse - MSM): Low rate of slippage, breakage, or both. (Specific numerical acceptance criterion not explicitly stated but implied as "low" and comparable to benchmark).0.68% (16/2351) total clinical failures for anal intercourse (MSM arm) across all condom types (0.62% for fitted, 0.67% for standard, 0.76% for thin), with no significant differences by condom type.
    Total Clinical Failure Rate (Vaginal Intercourse - MSW): Low rate of slippage, breakage, or both. (Specific numerical acceptance criterion not explicitly stated but implied as "low" and comparable to benchmark).1.89% (48/2533) total clinical failures for vaginal intercourse (MSW arm) across all condom types (2.01% for fitted, 0.95% for standard, 2.72% for thin).
    Adverse Event Rate: Low rate of AEs (STI acquisition, discomfort, etc.) during clinical use.Overall AEs 1.92% for both vaginal and anal intercourse. Anal intercourse AEs: 0.34% STI, 0.34% discomfort, 0.04% partner discomfort. Vaginal intercourse AEs: 0.04% STI, 0.27% discomfort, 0.04% partner UTI. All AEs reported as "low" and "commonly found."

    2. Sample Size for Test Set and Data Provenance

    • Sample Size (Clinical Study - Test Set):
      • Enrollment: 252 MSM (men who have sex with men) and 252 MSW (men who have sex with women) were enrolled.
      • Sex Acts Analyzed: 4,884 total anal or vaginal sex acts using study condoms (2,351 anal intercourse acts, 2,533 vaginal intercourse acts).
      • Condom Samples: Each participant received 5 of each of the three condom types (standard, thin, fitted), totaling 15 condoms per participant. The "n" in the clinical failure table denotes the number of sex acts performed with each condom type.
      • Bench Testing: 125 samples of each proposed size for dimensional analysis, water leak, airburst, and freedom from holes testing.
    • Data Provenance: Retrospective, conducted in Atlanta, Georgia at two sites of the Rollins School of Public Health at Emory University. The clinical study results were published in 2019 in the E Clinical Medicine Journal.

    3. Number of Experts Used to Establish Ground Truth for Test Set and Qualifications

    The provided text does not explicitly state the number of experts used to establish ground truth for the clinical study test set or their specific qualifications (e.g., radiologist with 10 years of experience).

    • Ground Truth Establishment: The primary endpoint, total clinical failure (slippage, breakage, or both), was assessed through a self-administered electronic daily coital diary completed by the study participants. This indicates that the "ground truth" for clinical failure was largely based on participant self-reporting, not independent expert review of individual events.
    • Study Investigators: While study investigators were involved in training participants and collecting information during biweekly visits, their role in establishing the "ground truth" for each specific failure event is not detailed beyond overseeing the data collection process. Participants and investigators were blinded to condom assignment.

    4. Adjudication Method for the Test Set

    The primary outcome of clinical failure (slippage, breakage, total clinical failure) was determined by self-reported data from electronic daily coital diaries completed by the participants. There is no mention of an independent adjudication method (e.g., 2+1, 3+1) for the reported clinical failure events.

    • The study design followed ISO 29943-1:2017 Condoms - Guidance on clinical studies - Part 1: Male Condoms, clinical function studies based on self-reports.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    No. This was not a multi-reader multi-case comparative effectiveness study. It was a clinical study evaluating the performance of the condom directly, not an AI-assisted detection or diagnosis device that would involve human readers. Therefore, there is no information about the effect size of human readers improving with AI vs without AI assistance.

    6. Standalone (Algorithm Only Without Human-in-the-Loop Performance)

    Yes, a form of standalone performance was assessed through bench performance testing (dimensional analysis, water leak, airburst, freedom from holes, visible defects) where the device's physical properties were directly evaluated against specified static criteria. The clinical study, while involving human use, evaluated the device's performance directly and the "algorithm" here is the physical condom itself, without a human-in-the-loop for interpreting results.

    7. Type of Ground Truth Used

    • Clinical Study: The ground truth for clinical failure events (slippage, breakage) was established through participant self-report via an electronic daily coital diary. Adverse event rates were also self-reported.
    • Bench Studies: The ground truth for bench performance was based on objective measurements against established standards (ISO 4074-15, ASTM D3492-16) for physical properties like dimensions, airburst pressure/volume, and freedom from holes.
    • Biocompatibility: Ground truth was based on standardized in-vitro and in-vivo biological tests (e.g., MEM Elution Test, Guinea Pig Maximization, Vaginal Irritation Test, Acute Systemic Toxicity).

    8. Sample Size for the Training Set

    The concept of a "training set" as typically understood in AI/ML (machine learning) is not directly applicable here as this is a physical medical device, not a software algorithm being trained on data.

    However, if "training set" refers to data used to inform the design and manufacturing of the condom, the context mentions:

    • The device is identical in material composition and manufacturing to condoms cleared in K081886, K122219, K141059, and K150072. This implies a large historical manufacturing and testing dataset that "trained" the understanding of condom properties.
    • Biocompatibility and bench performance testing leveraged data from these previously cleared condoms.

    Therefore, while not a formal "training set" for an algorithm, the underlying knowledge base for the device's design and material properties is extensive, derived from a history of manufacturing and testing.

    9. How the Ground Truth for the Training Set Was Established

    Again, in the context of a physical medical device, not an AI/ML model, the "ground truth" for the knowledge base that underpins the ONE Male Condom's design and manufacturing (analogous to a training set) was established through:

    • Adherence to International Standards: The device conforms to ISO 4074-15 and ASTM D3492-16, which are established standards based on extensive research and consensus regarding condom safety and performance. These standards define the "ground truth" for acceptable physical properties and performance.
    • Historical Data and Prior Clearances: Leverage of data from four previously cleared condom submissions (K081886, K122219, K141059, K150072). This means that previous rigorous testing (clinical, bench, biocompatibility) on structurally and materially identical condoms established the "ground truth" for their safety and effectiveness, which is now being applied to the ONE Male Condom.
    • Manufacturing Experience: The accumulated manufacturing experience for these identical devices contributes to the understanding of consistent product quality and performance parameters.
    Ask a Question

    Ask a specific question about this device

    K Number
    K172414

    Validate with FDA (Live)

    Date Cleared
    2017-10-12

    (63 days)

    Product Code
    Regulation Number
    884.5300
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K122219

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The JUD custom fit condom is used for contraception and for prophylactic purposes (to help prevent pregnancy and the transmission of sexually transmitted diseases).

    Device Description

    The JUD custom fit condom is made of a natural rubber latex sheath, which completely covers the penis with a closely fitted membrane. The condom is shaped with a reservoir end and is flat with a cylindrical shape. JUD custom fit condoms are available in 23 sizes of different length/width combinations. There is a fitting kit and instructions included as part of safe and effective usage of the condom.

    JUD custom fit condoms are provided pre-lubricated with a silicone-based lubricant. JUD custom fit condoms are not provided with spermicide, and contain no flavors or color additives. The user must use a fitting kit to select the appropriate size of the JUD custom fit condom.

    AI/ML Overview

    The document describes the JUD custom fit condom and its clearance via a 510(k) premarket notification. The study primarily relies on nonclinical bench testing and biocompatibility testing to demonstrate substantial equivalence to predicate devices, rather than a clinical study evaluating human-AI interaction or diagnostic accuracy.

    Here's an breakdown of the requested information based on the provided text:

    1. A table of acceptance criteria and the reported device performance

    Test DescriptionAcceptance Criteria (Standard)Reported Device Performance
    DimensionalISO 4074:2015Acceptance criteria met; dimensions conform to standards.
    Lubricant QuantityISO 4074:2015Acceptance criteria met.
    Burst Volume and PressureISO 4074:2015Acceptance criteria met; conform to standards.
    Freedom from Holes and Visible DefectsISO 4074:2015Acceptance criteria met; no visible defects identified.
    Package Seal IntegrityISO 4074:2015Acceptance criteria met; no damaged package seal identified.
    Shelf LifeMaintain specifications for 5 yearsEach condom variant maintained specifications for 5 years.
    CytotoxicityISO 10993-5:2009No cytotoxic reactivity found.
    Acute Systemic ToxicityISO 10993-11:2006No mortality or evidence of systemic toxicity.
    Vaginal IrritationISO 10993-10:2010Non-irritating; no signs of vaginal irritation.
    Skin SensitizationISO 10993-10:2010Did not induce skin sensitization.

    While not explicitly called "acceptance criteria" in the text, the "Summary and Conclusion" column effectively reports that the device met the requirements of the specified ISO standards, which represent the acceptance criteria for these tests.

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    The document refers to "tested samples" for bench testing and a "single condom variant" for biocompatibility testing. Specific sample sizes are not provided in the excerpt for any of the nonclinical tests. The data provenance (country of origin, retrospective/prospective) is also not specified, though the manufacturer is located in Malaysia.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    This is not applicable as the evaluation relies on objective bench testing and biocompatibility rather than expert interpretation of a test set related to medical imaging or diagnostics.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    This is not applicable for the type of testing described (bench and biocompatibility).

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    No MRMC comparative effectiveness study was performed or described. This device is a condom, not an AI-assisted diagnostic tool for human readers.

    6. If a standalone (i.e. algorithm only without human-in-the loop performance) was done

    This is not applicable as the device is a medical device (condom) and not an algorithm or AI system. The testing performed was standalone for the device itself (e.g., burst pressure of the condom).

    7. The type of ground truth used (expert concensus, pathology, outcomes data, etc)

    The "ground truth" for the bench tests was adherence to established international standards (ISO 4074:2015 and WHO 2010) for physical properties. For biocompatibility, the ground truth was biological response in animal models or in-vitro tests as defined by ISO 10993 series standards.

    8. The sample size for the training set

    This is not applicable as the device is not an AI/ML algorithm that requires a training set.

    9. How the ground truth for the training set was established

    This is not applicable as the device is not an AI/ML algorithm that requires a training set.

    Ask a Question

    Ask a specific question about this device