510(k) Data Aggregation

    K Number
    K133904

    Validate with FDA (Live)

    Date Cleared
    2014-02-25

    (67 days)

    Product Code
    Regulation Number
    888.3070
    Age Range
    All
    Reference & Predicate Devices
    Why did this record match?
    Reference Devices :

    K121764

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The CD HORIZON® Growth Rod Conversion Set is indicated in patients with potential for additional spinal growth under 10 years of age who require surgical treatment to obtain and maintain correction of severe, progressive, life-threatening, early-onset spinal deformities associated with thoracic insufficiency, including early-onset scoliosis. The CD HORIZON® Growth Rod Conversion Set may be used with any cleared traditional CD HORIZON® Spinal System rod construct ranging in diameter from 3.5mm to 5.5mm, with the exception of PEEK Rod constructs. The CD HORIZON® Growth Rod Conversion Set may not be used with PEEK Rods. SPIRE™ Spinous Process Plates, or Shape Memory Alloy (SMA) Staples.

    Device Description

    The CD HORIZON® Growth Rod Conversion Set consists of a variety of connectors designed to convert a traditional fusion construct into a non-fusion growth enabling construct which can be surgically lengthened on a periodic basis as the patient grows. The CD HORIZON® Growth Rod Conversion Set components are manufactured from stainless steel and titanium alloy and are designed to interact with rod-based pedicle screw/hook constructs in which the rods range in diameter from 3.5mm to 5.5mm. The CD HORIZON® Growth Rod Conversion Set is specifically to be used with any traditional CD HORIZON® Spinal System (3.5mm to 5.5mm) fusion construct cleared for pediatric usage. The CD HORIZON® Growth Rod Conversion Set may not be used with PEEK Rods, SPIRE® Spinous Process Plates and/or Shape Memory Alloy (SMA) Staples. The CD HORIZON® Growth Rod Conversion Set is limited to a posterior approach.

    AI/ML Overview

    This document is a 510(k) Premarket Notification from the FDA regarding the "CD HORIZON® Growth Rod Conversion Set." It primarily addresses the substantial equivalence of the device to a predicate device, rather than providing a detailed study proving performance against acceptance criteria. Therefore, most of the requested information regarding acceptance criteria, study details, ground truth, and expert involvement is not available in the provided text.

    However, I can extract the following information based on the document's content:

    1. A table of acceptance criteria and the reported device performance

    This information is not provided in the document. The FDA 510(k) clearance process focuses on demonstrating substantial equivalence to a predicate device, not necessarily on specific performance metrics or acceptance criteria for the new device as would be found in a clinical trial report.

    Instead, the document states:

    • Technological Characteristics: "The subject CD HORIZON® Growth Rod Conversion Set Spinal System has the same fundamental scientific technology as the predicate Harrington Spinal Rod System for the treatment of spinal deformities in a nonfusion manner. Additionally, the subject CD HORIZON® Growth Rod Conversion Set connectors are substantially equivalent to similar connectors previously cleared in the CD HORIZON® Spinal System (K121764, SE 08/21/12)."
    • Conclusion: "The design features, materials used, manufacturing and sterilization methods are equivalent to the pre-amendment Harrington Spinal Rod System device used to treat early onset deformities including early-onset scoliosis in a non-fusion manner and to previously cleared connectors which are contained within the CD HORIZON® Spinal System (K121764)."

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    This information is not provided. The document mentions "non-clinical testing" and "comparisons were made to Harrington Rod System," but does not specify sample sizes, data provenance, or study design (retrospective/prospective) related to a test set for performance evaluation.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    This information is not provided. The document does not describe the establishment of ground truth by experts for a test set.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    This information is not provided. There is no mention of a test set or associated adjudication method.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    This is not applicable to this device. The device is a "Growth Rod Conversion Set" for spinal surgery, not an AI-assisted diagnostic or imaging device used by human readers. Therefore, an MRMC study with AI assistance is not relevant.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    This is not applicable to this device. The device is a surgical implant, not a standalone algorithm.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    This information is not provided. The document focuses on performance testing to support fusion applications and comparisons to a predicate device, rather than establishing a ground truth for a diagnostic or predictive algorithm.

    8. The sample size for the training set

    This information is not provided. Given that this is a surgical implant device undergoing 510(k) clearance by demonstrating substantial equivalence, there would typically not be a "training set" in the context of machine learning or AI models.

    9. How the ground truth for the training set was established

    This information is not provided and is not applicable for the reasons mentioned in point 8.