510(k) Data Aggregation

    K Number
    K210925

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2021-04-28

    (30 days)

    Product Code
    Regulation Number
    878.4810
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K100078, K110685

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Flexiva Pulse and Flexiva Pulse TracTip laser fibers are intended to be used as a device that transmits Ho: YAG laser energy from cleared laser consoles to urological anatomy. Flexiva Pulse and Flexiva Pulse TracTip laser fibers are indicated for urologic applications for which the laser systems are cleared, limited to endoscopic procedures involving vaporization, ablation, hemostasis, coagulation, excision, incision of soft tissue, and lithotripsy of urinary calculi. The fiber is designed for use with a standard SMA-905 connector and has been cleared for surgical use.

    Flexiva Pulse ID and Flexiva Pulse ID TracTip laser fibers are intended to be used as a device that transmits Ho:YAG laser energy from cleared laser consoles to urological anatomy. Flexiva Pulse ID and Flexiva Pulse ID TracTip laser fibers are indicated for urologic applications for which the laser systems are cleared, limited to endoscopic procedures involving vaporization, ablation, hemostasis, coagulation, excision, resection, incision of soft tissue, and lithotripsy of urinary calculi. The fiber is designed for use with a standard SMA-905 connector and has been cleared for surgical use.

    Device Description

    The Flexiva Pulse Laser Fiber, Flexiva Pulse TracTip Laser Fiber, Flexiva Pulse ID Laser Fiber, and Flexiva Pulse ID TracTip Laser Fiber are fiber optic laser energy delivery devices consisting of a SMA connector (Black Hole design), and an ETFE jacketed silica core fiber. The Flexiva Pulse and Flexiva Pulse ID fibers are equipped with a polished, flat output tip (242um, 365um, 550um and 910um size) and the Flexiva Pulse TracTip and Flexiva Pulse ID TracTip fibers are equipped with a polished and reinforced ball-shaped output tip (242um size).

    For the Flexiva Pulse ID and the Flexiva Pulse ID TracTip laser fibers, an RFID (radio-frequency identification) tag enables read/write data storage for compatible RFID-equipped laser systems (closed systems).

    AI/ML Overview

    The provided document is a 510(k) summary for the Flexiva Pulse Laser Fibers. It describes the device, its intended use, and how it demonstrates substantial equivalence to predicate devices. However, this document does not contain a formal study that establishes specific acceptance criteria and then proves the device meets those criteria for the performance of the device in a clinical or simulated clinical setting. Instead, it focuses on demonstrating that the new device is as safe and effective as pre-existing, legally marketed predicate devices through a comparison of technological characteristics and extensive bench testing.

    Therefore, it's not possible to populate the requested table and answer many of the specific questions about a "study that proves the device meets the acceptance criteria" in the way one might for a novel AI/software medical device or a device requiring clinical performance validation against specific endpoints.

    Here's an attempt to address the request based only on the information provided in the given text, highlighting where information is absent:


    1. A table of acceptance criteria and the reported device performance

    The document does not explicitly state acceptance criteria in a quantitative format for clinical performance or sensitivity/specificity typical of diagnostic studies. Instead, the acceptance criteria are implicitly that the new device performs at least as well as, or equivalently to, the predicate devices in various bench tests and meets biocompatibility standards.

    Acceptance Criteria (Implicit from testing)Reported Device Performance
    Biocompatibility standards (ISO 10993-1:2018) met.All patient contacting materials meet applicable biocompatibility standards as per ISO 10993-1:2018 and FDA guidance. Passing results for Cytotoxicity, Sensitization, Irritation, Acute Systemic Toxicity, and Materials Mediated Pyrogenicity.
    Connector temperature within limits for normal use (IEC 60601-1:2005).The Flexiva Pulse laser fibers conform to Section 11.1.1, Maximum temperature during Normal Use, of IEC 60601-1:2005.
    Fiber Jacket Outer Diameter, Ball Tip Fracture Resistance, Distal Tip Length,Specific quantitative performance values are not provided, but the document states, "The results of the performance testing demonstrate that the Flexiva Pulse Laser Fiber, Flexiva PulseTracTip Laser Fiber, Flexiva Pulse ID Laser Fiber, and Flexiva Pulse ID TracTip Laser Fiber are considered safe and effective for their intended use." This implies that the device met the pre-defined (but not specified) acceptance limits for these tests, demonstrating equivalence or superior performance compared to the predicate for the design changes.
    Fiber Length, Bent Transmission, Fiber Stiffness, Power Rating & Efficiency
    Fiber Connector Temperature, Fiber Aiming Beam Visualization, Laser Compatibility
    RFID Recognition (for ID versions), Scope Adaptor Compatibility,
    Tensile Strength of fiber to connector housing, Fiber Hub to Connector Housing Torque
    Pouch Seal Integrity, Pouch Seal Strength
    No Damage to Scope Liner (Ball-Tip)

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    • Sample size for test set: Not explicitly stated for each bench test. The testing involved "samples aged at T=0 and T=3 year accelerated aging," but the number of samples for each test is not provided.
    • Data provenance: Bench evaluations conducted by Boston Scientific. The country of origin and whether it's retrospective or prospective are not applicable in the context of bench testing.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    • Not applicable as this is a device clearance based on substantial equivalence through bench testing, not a study evaluating human interpretation or a diagnostic algorithm against expert-established ground truth.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    • Not applicable.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • No, an MRMC comparative effectiveness study was not done. This device is a laser fiber for surgical use, not an AI/software diagnostic device.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    • Not applicable. This is a physical medical device (laser fiber), not an algorithm.

    7. The type of ground truth used (expert concensus, pathology, outcomes data, etc)

    • The "ground truth" for this submission are the established engineering and safety standards (e.g., ISO 10993-1, IEC 60601-1) and the performance characteristics of the predicate devices. The tests were designed to confirm that the new device meets these standards and performs comparably to or better than the predicate.

    8. The sample size for the training set

    • Not applicable. This is a physical medical device, not a machine learning model requiring a training set.

    9. How the ground truth for the training set was established

    • Not applicable.

    Summary of why information is missing:

    This document is a 510(k) summary for a physical medical device (laser fiber), not a software or AI-based diagnostic device. The clearance is based on demonstrating "substantial equivalence" to legally marketed predicate devices. This typically involves:

    • Comparing the intended use and technological characteristics.
    • Conducting extensive bench testing to ensure the new device meets safety and performance standards and performs comparably to the predicate.
    • Confirming biocompatibility.

    Therefore, the study described is a series of engineering and material performance tests, not a clinical trial or a diagnostic performance study, which would involve concepts like sample size for test/training sets, experts for ground truth, MRMC studies, or standalone algorithm performance.

    Ask a Question

    Ask a specific question about this device

    K Number
    K161771

    Validate with FDA (Live)

    Date Cleared
    2016-07-28

    (30 days)

    Product Code
    Regulation Number
    878.4810
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K110685

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Dornier's Medilas H RFID Laser Fibers are intended to be used as an accessory for the Dornier Medilas H Holmium Laser ("Laser"). This laser is intended for cutting, vaporization, ablation, and coagulation of soft tissue in conjunction with endoscopic equipment (including laparoscopes, hysteroscopes, bronchoscopes, gastroscopes, and colonoscopes), or for open surgery for contact or non-contact surgery with or without a handpiece for use in incision/excision, vaporization, ablation and coagulation of soft tissue. The Laser is indicated for use in medicine and surgery, in the following medical specialties:

    • Arthroscopy,
    • Urology,
    • Lithotripsy, ●
    • Pulmonology,
    • Gastroenterology,
    • Gynecology,
    • o ENT.
    • General Surgery.
    Device Description

    The Medilas H RFID Laser Fiber is a modification to Dornier's currently cleared Dornier Medilas H RFID Laser Fibers (K152591) to include a rounded, ball tip, distal end. The fiber core and cladding for the subject device are made from silica, which is same material used in the predicate device. Additionally, the fiber is manufactured and tested in the identical fashion as the company's predicate device and functions in an equivalent manner.

    AI/ML Overview

    The medical device described in the document is the "Dornier Medilas H RFID Gentle Flex Laser Fiber," an accessory for the Dornier Medilas H Holmium Laser. This device is a modification of a previously cleared device (K152591), with the primary change being the addition of a rounded, ball-tip distal end.

    Here's an analysis based on the provided text:

    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance Criteria (What was tested)Reported Device Performance (Result)
    Emission pattern of the distal tip from the laser colored aiming beam is equivalent to the predicate device.Confirmed as equivalent to the predicate device.
    Power transmission of the laser fibers when used with a Dornier Medilas H30 Holmium Laser is equivalent to the predicate device.Confirmed as equivalent to the predicate device.
    Tip fracture resistance of the ball tip fiber is equivalent to the predicate device.Confirmed as equivalent to the predicate device.
    Ability of the ball tip laser fibers to be introduced into a deflected scope with minimal resistance.Confirmed as having minimal resistance.

    2. Sample Size Used for the Test Set and Data Provenance

    The document does not specify the exact sample sizes used for each functional performance test. The data provenance is also not explicitly stated in terms of country of origin, nor whether the studies were retrospective or prospective.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts

    This information is not provided in the document. The performance tests appear to be engineering/technical evaluations rather than clinical studies requiring expert consensus on ground truth.

    4. Adjudication Method for the Test Set

    This information is not applicable or provided, as the tests described are functional performance tests rather than assessments requiring human adjudication of clinical outcomes.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done, and the Effect Size

    No MRMC comparative effectiveness study was mentioned or performed. The studies were non-clinical functional performance tests comparing the modified device to a predicate device.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Study Was Done

    This question is not applicable as the device is a medical accessory (laser fiber) and not an AI or algorithm-based device.

    7. The Type of Ground Truth Used

    For the functional performance tests, the "ground truth" was established by comparing the performance characteristics of the modified (subject) device against the established performance characteristics of the predicate device (Dornier Medilas H RFID Laser Fiber - K1525591). These are objective measurements related to physical and optical properties.

    8. The Sample Size for the Training Set

    This question is not applicable as the device is not an AI or algorithm-based device that requires a training set.

    9. How the Ground Truth for the Training Set Was Established

    This question is not applicable as the device is not an AI or algorithm-based device.